The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method
Abstract
Abstract Background and objective Blood pressure (BP) is one of the four vital signals that provides valuable medical information about the cardiovascular activity. In recent years, extensive studies have been conducted on non-invasive and cuff-less BP estimation using photoplethysmography (PPG) signals. PPG is a non-invasive optical method for measuring blood volume changes per pulse. In other words, the PPG waveform represents the mechanical activity of the heart. Methods In this paper, a new method for estimating the Mean Arterial Pressure (MAP), Diastolic Blood Pressure (DBP) and Systolic Blood Pressure (SBP) is proposed using only the PPG signal regardless of its shape (appropriate or inappropriate). Our proposed algorithm called whole-based, uses raw values of the PPG signal at a given time interval for estimating the BP. In other algorithms called parameter-based, use features which are extracted from PPG signals in time or frequency domain. These features related to precise spotting in the form of the PPG signal. In fact, compared to parameter-based methods, our algorithm is independent of the form of the PPG signal. Results Using the proposed algorithm, our results are completely met by the Association for the Advancement of Medical Instrumentation (AAMI) standard for both MAP and DBP estimations. The results are also very close to the standard boundary with an average error close to zero for SBP estimation. Also, according to the British Hypertension Society (BHS) standard, the proposed algorithm for DBP estimation got grade A, whereas it got grade B for estimation of MAP and got approximately grade C for SBP estimation. Conclusion The results demonstrate the applicability of the proposed algorithm in estimating BP noninvasively, cuff-less, calibration-free, and only by using the appropriate or inappropriate PPG signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621
Pulse Transit Time as an Indicator of Arterial Blood Pressure
Geddes, L. A., Voelz, M. H., Babbs, C. F., Bourland, J. D., & Tacker, W. A. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01545.x · Cited by 293
Peter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Cited by
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
PPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms
Ibtehaz, N., Mahmud, S., Chowdhury, M. E. H., Khandakar, A., Salman Khan, M., Ayari, M. A., Tahir, A. M., & Rahman, M. S. (2022) · Bioengineering · doi:10.3390/bioengineering9110692 · Cited by 133
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Photoplethysmography signal analysis to assess obesity, age group and hypertension
Ferdinando, H., Huotari, M., & Myllyla, T. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857570 · Cited by 9
Metadata
- Authors
- Mousavi, S. S., Firouzmand, M., Charmi, M., Hemmati, M., Moghadam, M., & Ghorbani, Y.
- Venue
- Biomedical Signal Processing and Control
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 47
- Pages
- 196-206
- ISSN
- 1746-8094 (ISSN-L)
- OpenAlex
- W2888894984
- Cited by
- 233
- References
- 7
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.