The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Ten questions concerning occupant health in buildings during normal operations and extreme events including the COVID-19 pandemic
Open accessAbstract
Even before the COVID-19 pandemic, people spent on average around 90% of their time indoors. Now more than ever, with work-from-home orders in place, it is crucial that we radically rethink the design and operation of buildings. Indoor Environmental Quality (IEQ) directly affects the comfort and well-being of occupants. When IEQ is compromised, occupants are at increased risk for many diseases that are exacerbated by both social and economic forces. In the U.S. alone, the annual cost attributed to sick building syndrome in commercial workplaces is estimated to be between $10 billion to $70 billion. It is imperative to understand how parameters that drive IEQ can be designed properly and how buildings can be operated to provide ideal IEQ to safeguard health. While IEQ is a fertile area of scholarship, there is a pressing need for a systematic understanding of how IEQ factors impact occupant health. During extreme events, such as a global pandemic, designers, facility managers, and occupants need pragmatic guidance on reducing health risks in buildings. This paper answers ten questions that explore the effects of buildings on the health of occupants. The study establishes a foundation for future work and provides insights for new research directions and discoveries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Proceedings of IEEE Conference on Computer Vision and Pattern Recognition
(1993) · doi:10.1109/cvpr.1993 · Cited by 17,667
Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1
van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A., Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2004973 · Cited by 9,951 · cited 1×
“The virus can also survive on a surface from a couple hours to 5 days depending on the surface material, exposing occupants to the virus [140].”
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Cold-Activated Brown Adipose Tissue in Healthy Men
van Marken Lichtenbelt, W. D., Vanhommerig, J. W., Smulders, N. M., Drossaerts, J. M. A. F. L., Kemerink, G. J., Bouvy, N. D., Schrauwen, P., & Teule, G. J. J. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0808718 · Cited by 3,452
Deep Hashing Network for Unsupervised Domain Adaptation
Venkateswara, H., Eusebio, J., Chakraborty, S., & Panchanathan, S. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.572 · Cited by 2,171
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
The Built Environment and Mental Health
Evans, G. W. (2003) · Journal of Urban Health: Bulletin of the New York Academy of Medicine · doi:10.1093/jurban/jtg063 · Cited by 1,374
The carcinogenicity of outdoor air pollution
Loomis, D., Grosse, Y., Lauby-Secretan, B., Ghissassi, F. E., Bouvard, V., Benbrahim-Tallaa, L., Guha, N., Baan, R., Mattock, H., & Straif, K. (2013) · The Lancet Oncology · doi:10.1016/s1470-2045(13)70487-x · Cited by 1,354
Trends in asthma prevalence, health care use, and mortality in the United States, 2001-2010.
Akinbami, L. J., Moorman, J. E., Bailey, C., Zahran, H. S., King, M., Johnson, C. A., & Liu, X. (2012) · PubMed · Cited by 1,188
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
Heating and cooling energy trends and drivers in buildings
Ürge-Vorsatz, D., Cabeza, L. F., Serrano, S., Barreneche, C., & Petrichenko, K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.039 · Cited by 1,089
Progress in physical activity over the Olympic quadrennium
Sallis, J. F., Bull, F., Guthold, R., Heath, G. W., Inoue, S., Kelly, P., Oyeyemi, A. L., Perez, L. G., Richards, J., & Hallal, P. C. (2016) · The Lancet · doi:10.1016/s0140-6736(16)30581-5 · Cited by 935
AIRBORNE SPREAD OF MEASLES IN A SUBURBAN ELEMENTARY SCHOOL
RILEY, E. C., MURPHY, G., & RILEY, R. L. (1978) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a112560 · Cited by 932
The American Community Survey: Summary of a Workshop
(2001) · National Academies Press eBooks · doi:10.17226/10051 · Cited by 859
Constitution of the World Health Organization
(1982) · International Organization and Integration Annotated Basic Documents and Descriptive Directory of International Organization and Arrangements · doi:10.1163/9789004634121_013 · Cited by 797
Shaw, M. (2004) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.25.101802.123036 · Cited by 791
Workspace satisfaction: The privacy-communication trade-off in open-plan offices
Kim, J., & de Dear, R. (2013) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2013.06.007 · Cited by 673
Childhood Incident Asthma and Traffic-Related Air Pollution at Home and School
McConnell, R., Islam, T., Shankardass, K., Jerrett, M., Lurmann, F., Gilliland, F., Gauderman, J., Avol, E., Künzli, N., Yao, L., et al. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.0901232 · Cited by 575
Spengler, J. D., McCarthy, J. F., & Samet, J. M. (2000) · Cited by 574
Cunha, B. A., Burillo, A., & Bouza, E. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60078-2 · Cited by 551
Housing as a determinant of health equity: A conceptual model
Swope, C. B., & Hernández, D. (2019) · Social Science & Medicine · doi:10.1016/j.socscimed.2019.112571 · Cited by 545
2019 Novel Coronavirus (COVID-19) Pandemic: Built Environment Considerations To Reduce Transmission
Dietz, L., Horve, P. F., Coil, D. A., Fretz, M., Eisen, J. A., & Van Den Wymelenberg, K. (2020) · mSystems · doi:10.1128/msystems.00245-20 · Cited by 491
Literature Review of the Effects of Natural Light on Building Occupants
Edwards, L., & Torcellini, P. (2002) · doi:10.2172/15000841 · Cited by 460
Noise levels in Johns Hopkins Hospital
Busch-Vishniac, I. J., West, J. E., Barnhill, C., Hunter, T., Orellana, D., & Chivukula, R. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.2118327 · Cited by 416
The psychological benefits of indoor plants: A critical review of the experimental literature
Bringslimark, T., Hartig, T., & Patil, G. G. (2009) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2009.05.001 · Cited by 405
(2013) · Designing Zero Carbon Buildings Using Dynamic Simulation Methods · doi:10.4324/9780203135754-30 · Cited by 404
A review of fault detection and diagnostics methods for building systems
Kim, W., & Katipamula, S. (2018) · Science and Technology for the Built Environment · doi:10.1080/23744731.2017.1318008 · Cited by 384
Sze To, G. N., & Chao, C. Y. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00621.x · Cited by 383
Income Segregation Between Schools and School Districts
Owens, A., Reardon, S. F., & Jencks, C. (2016) · American Educational Research Journal · doi:10.3102/0002831216652722 · Cited by 379
MILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
Natural Ventilation for Infection Control in Health-care Settings
Atkinson, J., Chartier, Y., Pessoa-Silva, C. L., Jensen, P. A., Li, Y., & Seto, W. (2010) · Virtual Defense Library (Ministerio de Defensa) · Cited by 345
Development of high efficiency nanofilters made of nanofibers
Ahn, Y.-C., Park, S., Kim, G., Hwang, Y. J., Lee, C. G., Shin, H., & Lee, J. K. (2005) · Current Applied Physics · doi:10.1016/j.cap.2005.07.013 · Cited by 341
‘Choosing’ to work when sick: workplace presenteeism
Dew, K., Keefe, V., & Small, K. (2005) · Social Science & Medicine · doi:10.1016/j.socscimed.2004.10.022 · Cited by 331
Public health and economic impact of dampness and mold
Mudarri, D., & Fisk, W. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00474.x · Cited by 319
Natural Ventilation for Infection Control in Health-Care Settings
Perino, M. (2009) · PORTO@Iris · Cited by 315
The impact of the ‘open’ workspace on human collaboration
Bernstein, E. S., & Turban, S. (2018) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2017.0239 · Cited by 305
Casey, J. A., Morello-Frosch, R., Mennitt, D. J., Fristrup, K., Ogburn, E. L., & James, P. (2017) · Environmental Health Perspectives · doi:10.1289/ehp898 · Cited by 286
Ten questions concerning green buildings and indoor air quality
Steinemann, A., Wargocki, P., & Rismanchi, B. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.010 · Cited by 268
The impact of heat waves on children’s health: a systematic review
Xu, Z., Sheffield, P. E., Su, H., Wang, X., Bi, Y., & Tong, S. (2014) · International Journal of Biometeorology · doi:10.1007/s00484-013-0655-x · Cited by 263
Investigation of human body skin temperatures as a bio-signal to indicate overall thermal sensations
Choi, J.-H., & Loftness, V. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.07.003 · Cited by 260
Houston, D., Wu, J., Ong, P., & Winer, A. (2004) · Journal of Urban Affairs · doi:10.1111/j.0735-2166.2004.00215.x · Cited by 235
Discomfort glare assessment and prevention for daylight applications in office environments
Osterhaus, W. (2005) · Solar Energy · doi:10.1016/j.solener.2004.11.011 · Cited by 234
Adamkiewicz, G., Zota, A. R., Fabian, M. P., Chahine, T., Julien, R., Spengler, J. D., & Levy, J. I. (2011) · American Journal of Public Health · doi:10.2105/ajph.2011.300119 · Cited by 234
Post-occupancy evaluation of 20 office buildings as basis for future IEQ standards and guidelines
Choi, J.-H., Loftness, V., & Aziz, A. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.08.009 · Cited by 231
Guo, M., Xu, P., Xiao, T., He, R., Dai, M., & Miller, S. L. (2021) · Building and Environment · doi:10.1016/j.buildenv.2020.107368 · Cited by 231
Mendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
Hoe, V. C., Urquhart, D. M., Kelsall, H. L., Zamri, E. N., & Sim, M. R. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008570.pub3 · Cited by 225
Sofuoglu, S. C., Aslan, G., Inal, F., & Sofuoglu, A. (2011) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2010.08.008 · Cited by 222
Nagata, T., Mori, K., Ohtani, M., Nagata, M., Kajiki, S., Fujino, Y., Matsuda, S., & Loeppke, R. (2018) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000001291 · Cited by 217
Association between ventilation rates in 390 Swedish homes and allergic symptoms in children
Bornehag, C. G., Sundell, J., Hagerhed-Engman, L., & Sigsgaard, T. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00372.x · Cited by 199
Energy savings, emission reductions, and health co-benefits of the green building movement
P., M., X., C., J., B., J., C.-L., J., S., A., B., & J., A. (2018) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-017-0014-9 · Cited by 190
Dannemiller, K. C., Mendell, M. J., Macher, J. M., Kumagai, K., Bradman, A., Holland, N., Harley, K., Eskenazi, B., & Peccia, J. (2014) · Indoor Air · doi:10.1111/ina.12072 · Cited by 183
Indoor moulds, Sick Building Syndrome and building related illness
Crook, B., & Burton, N. C. (2010) · Fungal Biology Reviews · doi:10.1016/j.fbr.2010.05.001 · Cited by 176
Heavy is the House: Rent Burden among the American Urban Poor
Desmond, M. (2018) · International Journal of Urban and Regional Research · doi:10.1111/1468-2427.12529 · Cited by 167
Whelton, A. J., McMillan, L., Connell, M., Kelley, K. M., Gill, J. P., White, K. D., Gupta, R., Dey, R., & Novy, C. (2015) · Environmental Science & Technology · doi:10.1021/es5040969 · Cited by 166
McArthur, J. J., & Powell, C. (2020) · Building and Environment · doi:10.1016/j.buildenv.2019.106635 · Cited by 164
Emeruwa, U. N., Ona, S., Shaman, J. L., Turitz, A., Wright, J. D., Gyamfi-Bannerman, C., & Melamed, A. (2020) · JAMA · doi:10.1001/jama.2020.11370 · Cited by 164
Sánchez, J. A., Ikaga, T., & Sánchez, S. V. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.07.065 · Cited by 160
Volatile emissions from common consumer products
Steinemann, A. (2015) · Air Quality, Atmosphere & Health · doi:10.1007/s11869-015-0327-6 · Cited by 156
Role of mechanical ventilation in the airborne transmission of infectious agents in buildings
Luongo, J. C., Fennelly, K. P., Keen, J., Zhai, Z. J., Jones, B., & Miller, S. L. (2015) · Indoor Air · doi:10.1111/ina.12267 · Cited by 148
Kraay, A. N. M., Hayashi, M. A. L., Hernández-Cerón, N., Spicknall, I. H., Eisenberg, M. C., Meza, R., & Eisenberg, J. N. S. (2018) · BMC Infectious Diseases · doi:10.1186/s12879-018-3425-x · Cited by 147
A review of fault detection and diagnosis methods for residential air conditioning systems
Rogers, A. P., Guo, F., & Rasmussen, B. P. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106236 · Cited by 143
Chew, G. L., Wilson, J., Rabito, F. A., Grimsley, F., Iqbal, S., Reponen, T., Muilenberg, M. L., Thorne, P. S., Dearborn, D. G., & Morley, R. L. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9258 · Cited by 140
Poor housing quality: Prevalence and health effects
Baker, E., Lester, L. H., Bentley, R., & Beer, A. (2016) · Journal of Prevention & Intervention in the Community · doi:10.1080/10852352.2016.1197714 · Cited by 140
Hamedani, Z., Solgi, E., Skates, H., Hine, T. J., Fernando, R., Lyons, J., & Dupré, K. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.02.035 · Cited by 132
Is a green building really better for building occupants? A longitudinal evaluation
Thatcher, A., & Milner, K. K. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.08.036 · Cited by 128
Battle for the thermostat: Gender and the effect of temperature on cognitive performance
Chang, T., & Kajackaite, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216362 · Cited by 125
Chirico, F., Sacco, A., Bragazzi, N. L., & Magnavita, N. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176052 · Cited by 123
Knibbs, L. D., Morawska, L., Bell, S. C., & Grzybowski, P. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.02.014 · Cited by 121
Schootman, M., Andresen, E. M., Wolinsky, F. D., Malmstrom, T. K., Miller, J. P., Yan, Y., & Miller, D. K. (2007) · American Journal of Epidemiology · doi:10.1093/aje/kwm190 · Cited by 121
Brody, J. G., Morello-Frosch, R. A., Zota, A. R., Brown, P., Pérez, C., & Rudel, R. A. (2009) · American Journal of Public Health · doi:10.2105/ajph.2008.149088 · Cited by 114
Circadian and Metabolic Effects of Light: Implications in Weight Homeostasis and Health
Plano, S. A., Casiraghi, L. P., Moro, P. G., Paladino, N., Golombek, D. A., & Chiesa, J. J. (2017) · Frontiers in Neurology · doi:10.3389/fneur.2017.00558 · Cited by 109
Ten questions concerning future buildings beyond zero energy and carbon neutrality
Wang, N., Phelan, P. E., González, J. E., Harris, C., Henze, G. P., Hutchinson, R., Langevin, J., Lazarus, M. A., Nelson, B., Pyke, C., et al. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.04.006 · Cited by 104
Osman, M. M., & Sevinç, H. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101429 · Cited by 104
Deep Hashing Network for Unsupervised Domain Adaptation
Ramakrishnan, R., Nagabandi, B., Eusébio, J., Chakraborty, S., Venkateswara, H., & Panchanathan, S. (2020) · Springer eBooks · doi:10.1007/978-3-030-45529-3_4 · Cited by 102
Thatcher, A., & Milner, K. K. (2014) · Work · doi:10.3233/wor-141876 · Cited by 100
Social and Built Environmental Correlates of Predicted Blood Lead Levels in the Flint Water Crisis
Sadler, R. C., LaChance, J., & Hanna‐Attisha, M. (2017) · American Journal of Public Health · doi:10.2105/ajph.2017.303692 · Cited by 100
Zhu, X., Yoshikawa, A., Qiu, L., Lu, Z., Lee, C., & Ory, M. G. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106455 · Cited by 97
Sleep quality and noise: comparisons between hospital and home settings
Bevan, R. T., Grantham-Hill, S., Bowen, R., Clayton, E., Grice, H., Venditti, H. C., Stickland, A., & Hill, C. M. (2018) · Archives of Disease in Childhood · doi:10.1136/archdischild-2018-315168 · Cited by 93
Topf, M., & Thompson, S. (2001) · Heart & Lung · doi:10.1067/mhl.2001.116592 · Cited by 92
Pellow, J., Solomon, E. M., & Barnard, C. N. (2011) · PubMed · Cited by 92
Modelling changes in VOC emission in response to climate change in the continental United States
Constable, J. V. H., Guenther, A., SCHIMEL, D. S., & Monson, R. K. (1999) · Global Change Biology · doi:10.1046/j.1365-2486.1999.00273.x · Cited by 90
Stress recovery in forest or handicraft environments – An intervention study
Dolling, A., Nilsson, H., & Lundell, Y. (2017) · Urban forestry & urban greening · doi:10.1016/j.ufug.2017.07.006 · Cited by 86
Mold and Human Health: a Reality Check
Borchers, A. T., Chang, C. C.-C., & Gershwin, M. E. (2017) · Clinical Reviews in Allergy & Immunology · doi:10.1007/s12016-017-8601-z · Cited by 83
Mental Health and The Built Environment
Halpern, D. (2014) · Routledge eBooks · doi:10.4324/9781315041131 · Cited by 82
Shah, S. N., Fossa, A. J., Steiner, A. S., Kane, J., Levy, J. I., Adamkiewicz, G., Bennett-Fripp, W. M., & Reid, M. (2018) · Journal of Urban Health · doi:10.1007/s11524-018-0298-7 · Cited by 82
Gilani, S. I. U.-H., Khan, M. H., & Ali, M. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.08.050 · Cited by 78
Heat-related morbidity and mortality in New England: Evidence for local policy
Wellenius, G. A., Eliot, M., Bush, K. F., Holt, D., Lincoln, R. A., Smith, A. E., & Gold, J. (2017) · Environmental Research · doi:10.1016/j.envres.2017.02.005 · Cited by 78
Report of an outbreak: nursing home architecture and influenza-A attack rates
Drinka, P. J., Krause, P., Schilling, M., Miller, B. A., Shult, P., & Gravenstein, S. (1996) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1996.tb01859.x · Cited by 77
Occupier perceptions of green workplace environment: the Australian experience
Kato, H., Too, L., & Rask, A. (2009) · Journal of Corporate Real Estate · doi:10.1108/14630010910985931 · Cited by 72
Ni, M. Y., Yao, X. I., Cheung, F., Wu, J. T. K., Schooling, C. M., Pang, H., & Leung, G. M. (2019) · International Journal of Epidemiology · doi:10.1093/ije/dyz238 · Cited by 70
Healthy Homes and CommunitiesPutting the Pieces Together
Miller, W. D., Pollack, C. E., & Williams, D. R. (2010) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.09.024 · Cited by 69
Sadick, A.-M., & Issa, M. H. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.03.045 · Cited by 65
Effects of Temperature and Humidification in the Office Environment
Reinikainen, L. M., & Jaakkola, J. J. K. (2001) · Archives of Environmental Health An International Journal · doi:10.1080/00039890109604469 · Cited by 62
Does the utilization of coal fly ash in concrete construction present a radiation hazard?
Kovler, K. (2011) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2011.10.023 · Cited by 57
Respiratory and general health complaints in subjects exposed to sandstorm at Riyadh, Saudi Arabia
Meo, S. A., Al-Kheraiji, M. F. A., AlFaraj, Z. F., Alwehaibi, N. A., & Aldereihim, A. A. (2013) · Pakistan Journal of Medical Sciences · doi:10.12669/pjms.292.3065 · Cited by 57
Cunliffe, D., Bartram, J., Briand, E., Chartier, Y., Colbourne, J., Drury, D. D., Lee, J., Schaefer, B., & Surman-Lee, S. (2011) · Cited by 57
Allen, J. G., & Macomber, J. D. (2020) · Harvard University Press eBooks · doi:10.4159/9780674246102 · Cited by 57
Identification of SARS‐CoV‐2 RNA in healthcare heating, ventilation, and air conditioning units
Horve, P. F., Dietz, L. G., Fretz, M., Constant, D. A., Wilkes, A., Townes, J. M., Martindale, R. G., Messer, W. B., & Wymelenberg, K. G. V. D. (2021) · Indoor Air · doi:10.1111/ina.12898 · Cited by 54
Non-Wearable UWB Sensor for Human Identification in Smart Home
Mokhtari, G., Zhang, Q., Hargrave, C. O., & Ralston, J. C. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2694555 · Cited by 50
HEAT - Human Embodied Autonomous Thermostat
Li, D., Menassa, C. C., Kamat, V. R., & Byon, E. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106879 · Cited by 46
Financial implications of modifications to building filtration systems
Montgomery, J. F., Reynolds, C. C. O., Rogak, S. N., & Green, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.11.005 · Cited by 42
Indoor versus Outdoor Air Quality during Wildfires
Messier, K. P., Tidwell, L. G., Ghetu, C. C., Rohlman, D., Scott, R. P., Bramer, L., Dixon, H. M., Waters, K. M., & Anderson, K. A. (2019) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.9b00599 · Cited by 41
Sensing Occupant Comfort Using Wearable Technologies
Abdallah, M., Clevenger, C. M., Vu, T. N., & Nguyen, A. D. (2016) · ASCE Construction Research Congress (CRC) · doi:10.1061/9780784479827.095 · Cited by 40
An estimation of airborne SARS-CoV-2 infection transmission risk in New York City nail salons
Harrichandra, A., Ierardi, A. M., & Pavilonis, B. (2020) · Toxicology and Industrial Health · doi:10.1177/0748233720964650 · Cited by 40
Sofuoǧlu, S. C. (2007) · Building and Environment · doi:10.1016/j.buildenv.2007.03.003 · Cited by 39
Sensor Fusion for Fault Detection and Classification in Distributed Physical Processes
Sarkar, S., Sarkar, S., Virani, N., Ray, A., & Yasar, M. (2014) · Frontiers in Robotics and AI · doi:10.3389/frobt.2014.00016 · Cited by 38
Ben-David, T., Rackes, A., Lo, L. J., Wen, J., & Waring, M. S. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106314 · Cited by 37
Self-citationPodrekar, N., Kozinc, Ž., & Šarabon, N. (2020) · Work · doi:10.3233/wor-203108 · Cited by 29
Gargano, L. M., Locke, S., Jordan, H. T., & Brackbill, R. M. (2018) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2017.140 · Cited by 25
Ergonomic assessment of working postures for the design of university computer workstations
Chowdhury, N., Aghazadeh, F., & Amini, M. (2018) · Occupational Ergonomics · doi:10.3233/oer-170252 · Cited by 19
Semi-Supervised Prediction-Constrained Topic Models
Hughes, M. C., Hope, G., Weiner, L., McCoy, T. H., Perlis, R. H., Sudderth, E. B., & Doshi‐Velez, F. (2018) · International Conference on Artificial Intelligence and Statistics · Cited by 17
No Home for Justice: How Eviction Perpetuates Health Inequity among Low-Income and Minority Tenants
Gold, A. E. (2016) · eYLS (Yale Law School) · Cited by 13
Indoor Air Quality and Office Property Value
Addae‐Dapaah, K., Tham, K. W., Dollah, M. J. B., & Foo, Y. (2010) · Journal of Sustainable Real Estate · doi:10.1080/10835547.2010.12091799 · Cited by 9
Cited by
Nundy, S., Ghosh, A., Mesloub, A., Albaqawy, G. A., & Alnaim, M. M. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.127705 · Cited by 301
Wang, C., Su, K., Hu, L., Wu, S., Zhan, Y., Yang, C., & Xiang, J. (2024) · Indoor Environments · doi:10.1016/j.indenv.2024.100015 · Cited by 2
Metadata
- Authors
- Awada, M., Becerik-Gerber, B., Hoque, S., O'Neill, Z., Pedrielli, G., Wen, J., & Wu, T.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 188
- Pages
- 107480
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W3109080021
- Cited by
- 262
- References
- 114
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.