Cited by 65Per- and polyfluoroalkyl substances researchAnalytical chemistry methods developmentMass Spectrometry Techniques and Applications

Trace level determination of perfluorinated compounds in water by direct injection

Furdui, Vasile I., Crozier, Patrick W., Reiner, Eric J., Mabury, Scott A.·2008·Chemosphere

Abstract

A new, fast LC-MS/MS method for the determination of perfluorinated surfactants in water samples by direct injection without pre-concentration is reported. The current method requires only 4 min to analyze nine perfluoroalkyl compounds in a single analytical run. Standard addition and internal standard quantification were used to determine the level of some perfluorinated carboxylic and sulfonic acids, including perfluorooctanoic sulfonate (PFOS) and perfluorooctanoic acid (PFOA), in Great Lakes water samples. Statistically significant differences were observed between the results obtained using different quantification methods. A relatively small difference between the PFOS values obtained with the standard addition method, with and without peak area normalization, clearly indicates that standard addition is the best quantification method when mass-labeled standards are not available. Based on the paired t-test statistical analysis, the concentrations calculated using external standardization were the least accurate, with the highest mean difference from the standard addition calculated values. Both PFOS and PFOA were present at less than 10 ng l(-1) in all Great Lake samples. Higher levels were detected in tributaries of Lake Ontario and effluents from sewage treatment plants.

Integrity signals

Registry

Crossref · 10.1016/j.chemosphere.2007.07.085

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Furdui, V. I., Crozier, P. W., Reiner, E. J., & Mabury, S. A.
Affiliations
University of Toronto (CA)
Corresponding author
Mabury, Scott A.
Venue
Chemosphere
Publisher
Elsevier BV
Published
2008-08
Volume
73
Issue
1
Pages
S24-S30
ISSN
0045-6535 (ISSN-L)
OpenAlex
W2037279962
Cited by
65
References
23
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 1 · 2022: 1 · 2021: 4 · 2020: 4 · 2019: 4 · 2018: 2 · 2017: 3 · 2015: 2 · 2013: 10 · 2012: 8
FWCI
4.86
Type
journal article
Language
en
Open access
closed
Locations
  • Chemosphere (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
perfluorinated compounds, perfluorooctanoic acid, perfluorinated carboxylic acids, perfluorinated sulfonic acids, perfluorinated surfactants, water pollution, Great Lakes, sewage treatment plant effluent, internal standard quantification, external standardization
MeSH terms
Environmental Pollutants, Fluorocarbons, Injections, Reference Standards, Sewage, Surface-Active Agents, Water, Rivers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review