The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Determination of adsorbable organic fluorine from aqueous environmental samples by adsorption to polystyrene-divinylbenzene based activated carbon and combustion ion chromatography
Abstract
A new method for the determination of trace levels of adsorbable organic fluorine (AOF) in water is presented. Even if the individual contributing target compounds are widely unknown, this surrogate parameter is suited to identify typical organofluorine contaminations, such as with polyfluorinated chemicals (PFCs), and represents a lower boundary of the organofluorine concentration in water bodies. It consists of the adsorption of organofluorine chemicals on a commercially available synthetic polystyrene-divinylbenzene based activated carbon (AC) followed by analysis of the loaded AC by hydropyrolysis combustion ion chromatography (CIC). Inorganic fluorine is displaced by excess nitrate during the extraction step and by washing the loaded activated carbon with an acidic sodium nitrate solution. Due to its high purity the synthetic AC had a very low and reproducible fluorine blank (0.3 μg/g) compared to natural ACs (up to approximately 9 μg/g). Using this AC, fluoride and the internal standard phosphate could be detected free of chromatographic interferences. With a sample volume of 100 mL and 2× 100 mg of AC packed into two extraction columns combined in series, a limit of quantification (LOQ), derived according to the German standard method DIN 32645, of 0.3 μg/L was achieved. The recoveries of six model PFCs were determined from tap water and a municipal wastewater treatment plant (WWTP) effluent. Except for the extremely polar perfluoroacetic acid (recovery of approximately 10%) the model substances showed fairly good (50% for perfluorobutanoic acid (PFBA)) to very good fluorine recoveries (100±20% for perfluorooctanoic acid (PFOA), perfluorobutanesulfonate (PFBS), 6:2 fluorotelomersulfonate (6:2 FTS)), both from tap water and wastewater matrix. This new analytical protocol was exemplarily applied to several surface water and groundwater samples. The obtained AOF values were compared to the fluorine content of 19 target PFCs analyzed by high performance liquid chromatography-electrospray tandem mass spectrometry (HPLC-(-)ESI-MS/MS). In groundwater contaminated by PFC-containing aqueous film-forming foams (AFFFs) up to 50% of the AOF could be attributed to PFC target chemicals, while in diffuse contaminated samples only <5% of the AOF could be identified by PFC analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Early applications of CIC and PIGE in reghting foams, biota and textiles have revealed that only a small fraction of the organic uorine content can be accounted for by known PFASs.31,33,37”
Citations
Cites
Greenwood, N. N., & Earnshaw, A. (1984) · Cited by 5,489
Perfluoroalkyl Acids: A Review of Monitoring and Toxicological Findings
Lau, C., Anitole, K., Hodes, C., Lai, D., Pfahles-Hutchens, A., & Seed, J. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfm128 · Cited by 2,620
Polyfluorinated Compounds: Past, Present, and Future
Lindstrom, A. B., Strynar, M. J., & Libelo, E. L. (2011) · Environmental Science & Technology · doi:10.1021/es2011622 · Cited by 1,628
Monitoring of Perfluorinated Compounds in Aquatic Biota: An Updated Review: PFCs in Aquatic Biota
Houde, M., De Silva, A. O., Muir, D. C. G., & Letcher, R. J. (2011) · Environmental Science & Technology · doi:10.1021/es104326w · Cited by 847
Appendix Four The Stockholm Convention on Persistent Organic Pollutants
(2003) · McGill-Queen's University Press eBooks · doi:10.1515/9780773570672-020 · Cited by 621
Fluoride toxicity to aquatic organisms: a review
Camargo, J. A. (2003) · Chemosphere · doi:10.1016/s0045-6535(02)00498-8 · Cited by 407
Quantitative determination of fluorotelomer sulfonates in groundwater by LC MS/MS
Schultz, M. M., Barofsky, D. F., & Field, J. A. (2004) · Environmental Science & Technology · doi:10.1021/es035031j · Cited by 373
Miyake, Y., Yamashita, N., Rostkowski, P., So, M. K., Taniyasu, S., Lam, P. K. S., & Kannan, K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.12.071 · Cited by 243
Transformation of the X-ray Contrast Medium Iopromide In Soil and Biological Wastewater Treatment
Schulz, M., Löffler, D., Wagner, M., & Ternes, T. A. (2008) · Environmental Science & Technology · doi:10.1021/es800789r · Cited by 161
Polyfluorinated Chemicals and Transformation Products
(2012) · The Handbook of Environmental Chemistry · doi:10.1007/978-3-642-21872-9 · Cited by 142
Self-citation
Flagged first, then by citations
1 of the 20 references couldn’t be matched to a known paper.
Research works printed but not linked: 6
- Stockholm Convention on persistent organic pollutants, Official Journal of the European Union, L 209/3, 31.07.06.
- Twiehaus, 2003, Ökotox, 15, 60.09
- Rollinger, 1996, J. Anal. Chem., 354, 892
- Laschka, 1996, Vom Wasser, 87, 89
- Schnitzler, 1989, Vom Wasser, 73, 43
- Schnitzler, 1983, Vom Wasser, 61, 263
Cited by
Sorted by citations
Items 101–107 of 107
Trier, X., Taxvig, C., Rosenmai, A. K., & Pedersen, G. A. (2018) · TemaNord · doi:10.6027/fedb3330-en
Mai, J., Dolatabad, A. A., Sun, R., Cao, J., Zhang, X., Paramban, S., Mohammadtabar, C., Frommelt, B., Jenkins, A., Yazdani, H., et al. (2025) · Journal of Hazardous Materials Organics · doi:10.1016/j.hazmo.2025.100008
Fredriksson, F., Eriksson, U., Kärrman, A., & Yeung, L. W. Y. (2026) · Environmental Science & Technology · doi:10.1021/acs.est.6c03578
Lünne, F., Zorn, T. A., Köhrer, A., Schünemann, P., Kampf, S., Meermann, B., & Schaffert, D. (2026) · Angewandte Chemie · doi:10.1002/ange.2517884
Lünne, F., Zorn, T. A., Köhrer, A., Schünemann, P., Kampf, S., Meermann, B., & Schaffert, D. (2026) · Angewandte Chemie International Edition · doi:10.1002/anie.2517884
Metadata
- Authors
- Wagner, A., Raue, B., Brauch, H.-J., Worch, E., & Lange, F. T.
- Affiliations
- DVGW - Technologiezentrum Wasser (DE)
- Technische Universität Dresden (DE)
- Corresponding author
- Lange, Frank T.
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2013-06
- Volume
- 1295
- Pages
- 82-89
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W1974916973
- Cited by
- 107
- References
- 20
- Citations by year
- 2026: 6 · 2025: 9 · 2024: 12 · 2023: 13 · 2022: 10 · 2021: 14 · 2020: 8 · 2019: 12 · 2018: 9 · 2017: 3 · 2016: 7 · 2015: 4
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Environmental Science › Water Science and Technology › Fluoride Effects and Removal
- Keywords
- activated carbon adsorption, combustion ion chromatography, hydropyrolysis, perfluorooctanoic acid, perfluorobutanoic acid, perfluorobutanesulfonate, groundwater contamination, wastewater treatment plant effluent, tap water
- MeSH terms
- Adsorption, Charcoal, Chromatography, Ion Exchange, Fluorine, Polystyrenes, Water Pollutants, Chemical, Solid Phase Extraction, Groundwater, Wastewater
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review