Deep brain stimulation and electromagnetic interference
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Deep brain stimulation (DBS) has evolved into an approved and efficacious treatment for movement, obsessive-compulsive, and epilepsy disorders that are refractory to medical therapy, with current investigation into other disease conditions. However, there are unintentional and intentional sources of external electromagnetic interference (EMI) that can lead to either malfunctioning or damaged DBS devices, as well as injury to human tissue. Comprehensive studies and guidelines on such topics in the medical literature are scarce. Herein, we review the principles behind EMI, as well as the various potential sources of interference, both unintentional (e.g. stray EMI fields) and intentional (e.g. MRI scans, "brainjacking"). Additionally, we employ the Manufacturer and User Device Facility Experience (MAUDE) database to assess real-world instances of EMI (e.g., airport body scanners, magnetic resonance imaging (MRI), and electrosurgery) affecting DBS devices commonly implanted in the United States (US).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, RF systems for charging may induce voltages in nearby data circuits, causing data loss or errors, while power harvesting in battery-less systems might disrupt high-frequency data signals (Bazaka and Jacob, 2012; Rahimpour et al., 2021; Won et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Rahimpour et al., 2021
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, RF systems for charging may induce voltages in nearby data circuits, causing data loss or errors, while power harvesting in battery-less systems might disrupt high-frequency data signals (Bazaka and Jacob, 2012; Rahimpour et al., 2021; Won et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Rahimpour et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
A Randomized Trial of Deep-Brain Stimulation for Parkinson's Disease
Deuschl, G., Schade-Brittinger, C., Krack, P., Volkmann, J., Schäfer, H., Bötzel, K., Daniels, C., Deutschländer, A., Dillmann, U., Eisner, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060281 · Cited by 2,944
Bilateral Deep-Brain Stimulation of the Globus Pallidus in Primary Generalized Dystonia
Vidailhet, M., Vercueil, L., Houeto, J.-L., Krystkowiak, P., Benabid, A.-L., Cornu, P., Lagrange, C., Tézenas du Montcel, S., Dormont, D., Grand, S., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042187 · Cited by 1,094
Chronic Anterior Thalamus Stimulation for Intractable Epilepsy
Hodaie, M., Wennberg, R. A., Dostrovsky, J. O., & Lozano, A. M. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.26001.x · Cited by 605
MR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Electrotherapy Explained: Principles and Practice
Robertson, V. J., Ward, A., Low, J. N., & Reed, A. M. (1991) · Cited by 334
Directional deep brain stimulation: an intraoperative double-blind pilot study
Pollo, C., Kaelin-Lang, A., Oertel, M. F., Stieglitz, L., Taub, E., Fuhr, P., Lozano, A. M., Raabe, A., & Schüpbach, M. (2014) · Brain · doi:10.1093/brain/awu102 · Cited by 327 · cited 1×
“Besides two cylindrical electrodes, the 8CH has two central contacts consisting of three segments each, which can be activated independently to concentrate stimulation in one direction, thereby theoretically reducing current needed to produce meaningful therapeutic effects by up to 43 % [11].”
BackgroundHenderson, J. M., Tkach, J., Phillips, M., Baker, K., Shellock, F. G., & Rezai, A. R. (2005) · Neurosurgery · doi:10.1227/01.neu.0000180810.16964.3e · Cited by 314 · cited 1×
“Examples of reported consequences of EMI include: (1) development of unexpected thalamic lesions, secondary to cardioversion [19]; (2) aphasia, dysarthria, and hemiparesis, resulting from a radiofrequency lesion produced by heating of a DBS electrode during MRI of the lumbar spine [20]; and even (3) persistent vegetat…”
BackgroundSecurity and privacy issues in implantable medical devices: A comprehensive survey
Camara, C., Peris-Lopez, P., & Tapiador, J. E. (2015) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.04.007 · Cited by 293
Interference with Cardiac Pacemakers by Cellular Telephones
Hayes, D. L., Wang, P. J., Reynolds, D. W., Estes, N. A. M., Griffith, J. L., Steffens, R. A., Carlo, G. L., Findlay, G. K., & Johnson, C. M. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705223362101 · Cited by 282 · cited 1×
“These devices are known to be potential sources of interference with pacemakers and defibrillators; however, very little is known regarding interference with DBS [29,30].”
Background
Research works printed but not linked: 3
- Arle J, Shils JL (Eds.), Essential Neuromodulation, Academic Press, 2011, pp. 325– 348. Apr 14. Chapter 15.
- SJM, Lead and Extension Kits for Deep Brain Stimulation Systems – Clinician’s Manual, 2017, pp. 1– 50 (null).
- Kainz W, Alesch F, Chan DD, Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-III, Biomed. Eng. Online 2 (2003) 11. 12773204 PMC156641 · DOI · Paper page
Cited by
A review on electromagnetic shielding magnesium alloys
Liu, L., Chen, X., & Pan, F. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.10.001 · Cited by 193
Zhang, T., Pan, N., Wang, Y., Liu, C., & Hu, S. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.749162 · Cited by 177
Advancements in 3D-printed architectures for electromagnetic interference shields
Zhang, G., Wang, H., Xie, W., Zhou, S., Nie, Z., Niwamanya, G., Zhao, Z., & Duan, H. (2024) · Journal of Materials Chemistry A · doi:10.1039/d3ta07181b · Cited by 61
Excitatory‐inhibitory modulation of transcranial focus ultrasound stimulation on human motor cortex
Zhang, T., Guo, B., Zuo, Z., Long, X., Hu, S., Li, S., Su, X., Wang, Y., & Liu, C. (2023) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.14303 · Cited by 60
Li, J., Zhong, L., Wang, J., Feng, Z., Qu, Y. D., & Xu, R. (2024) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2024.03.013 · Cited by 44
Ultrathin Multilayer Textile Structure with Enhanced EMI Shielding and Air-Permeable Properties
Hu, S. S., Wang, D., Periyasamy, A. P., Křemenáková, D., Militký, J., & Tunák, M. (2021) · Polymers · doi:10.3390/polym13234176 · Cited by 35
“The influence of electromagnetic waves on human health is contentious, but to date, scientific consensus has been that excessive electromagnetic radiation impacts human health [1,2].”
BackgroundBroderick, L., Tuohy, G., Solymos, O., Lakhani, S., Staunton, B., Ennis, P., Clark, N., Moppett, I. K., Chalissery, A. J., Kilbride, R. D., et al. (2023) · Anaesthesia · doi:10.1111/anae.16012 · Cited by 27
“Temporary suppression of generator output and/or reprogramming can also occur [49].”
BackgroundSarica, C., Yamamoto, K., Loh, A., Elias, G. J. B., Boutet, A., Madhavan, R., Germann, J., Zemmar, A., Gwun, D., Tasserie, J., et al. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2021.108153 · Cited by 23
Sowder, T., Sayed, D., Concannon, T. A., Pew, S., Strand, N. H., Abd-Elsayed, A. A., Wie, C. S., Ramos, D. E. G., Raslan, A. M. T., & Deer, T. R. (2023) · Journal of Pain Research · doi:10.2147/jpr.s419594 · Cited by 22
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
“For example, RF systems for charging may induce voltages in nearby data circuits, causing data loss or errors, while power harvesting in battery-less systems might disrupt high-frequency data signals (Bazaka and Jacob, 2012; Rahimpour et al., 2021; Won et al., 2021).”
BackgroundSharma, G. K., Joseph, S. L., & James, N. R. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202301203 · Cited by 19
Wang, S., Xiu, H., Yin, D., Li, J., Liu, G., Qin, Y., Hua, F., Meng, Q., Min-zhe, W., & Shen, M. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c18237 · Cited by 10
Recent Advances in Electromagnetic Wave Absorbers Fabricated Via Additive Manufacturing
Noh, D., Lim, H., Lee, J., Jang, H., Hong, M., Ji, S., Kang, T., Kang, B., Kim, J., Lee, J., et al. (2025) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-025-00764-7 · Cited by 11
“As the EM environment grows increas - ingly diverse and complex, EMI escalates correspondingly a growing concern because EMI negatively impacts human health and the operation of precision electronic devices, posing significant safety risks to medical apparatus and avionics systems [ 8– 12].”
Straw, I., Ashworth, C., & Radford, N. (2022) · BMJ Case Reports · doi:10.1136/bcr-2022-252305 · Cited by 10
Brain‐implanted conductors amplify radiofrequency fields in rodents: Advantages and risks
Vöröslakos, M., Yaghmazadeh, O., Alon, L., Sodickson, D. K., & Buzsáki, G. (2023) · Bioelectromagnetics · doi:10.1002/bem.22489 · Cited by 9
“To monitor brain temperature changes, we used a metal ‐ free optical temperature measurement system to avoid interference of RF energy with electronic components (Rahimpour et al., 2021; Yaghmazadeh et al., 2022).”
MethodLi, X., Feng, Y., Gong, Y., & Chen, Y. (2024) · Journal of Patient Safety · doi:10.1097/pts.0000000000001220 · Cited by 12
Lencar, C., Ramakrishnan, S., & Sundararaj, U. (2022) · Nanomaterials · doi:10.3390/nano12213772 · Cited by 8
“Furthermore, there are health implications due to high exposure to EM waves, and serious chronic health issues may arise in humans [5,6].”
BackgroundIn vitro electrical stimulation devices: practical framework for design, fabrication, and operation
Kulkarni, G., Garcia, J. M., Isasi-Campillo, M., González, M. U., & Mobini, S. (2026) · Journal of Biological Engineering · doi:10.1186/s13036-026-00664-7 · Cited by 7
Le, D. T. A., Nguyen, H. Q., & Jang, Y. M. (2024) · Applied Sciences · doi:10.3390/app14031003 · Cited by 7
Feasibility study of magnetic sensing for detecting single-neuron action potentials
Tonini, D., Kai, W., Saha, R., & Wang, J. (2022) · Annals of Biomedical Science and Engineering · doi:10.29328/journal.abse.1001018 · Cited by 7
Interaction of positive airway pressure mask magnets with cardiac implantable electronic devices
Ruoff, C. M., Tashman, Y., Cheema, K. P. K., Miller, B. W., Houser, R. F., Lizak, M., Haley, C. C., Petersen, A. M., Goswami, U., Lyng, P. J., et al. (2023) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10478 · Cited by 6
Saha, N., Millward, J. M., Herrmann, C. J. J., Rahimi, F., Han, H., Lacour, P., Blaschke, F., & Niendorf, T. (2023) · Sensors · doi:10.3390/s23031209 · Cited by 6
“EMI with other AIMDs such as deep brain stimulators (DBS), and neurostimulators for spine and cochlear implants remains uninvestigated [21].”
BackgroundSomarajan, A., Paul, R., & Joseph, K. (2024) · Journal of Polymer Science · doi:10.1002/pol.20240350 · Cited by 4
Systematic Literature Review of EM-SCA Attacks on EncryptionPreprint
Zunaidi, M. R., Scanlon, M., & Sayakkara, A. (2024) · doi:10.36227/techrxiv.170831690.06196196/v1 · Cited by 8
Medical Data over Sound—CardiaWhisper Concept
Stojanovic, R. D., Đurković, J., Vukmirović, M., Babić, B., Miranović, V., & Škraba, A. (2025) · Sensors · doi:10.3390/s25154573 · Cited by 3
“Despite the widespread use of wireless technologies such as Bluetooth, Wi-Fi, and ZigBee in wearable healthcare systems, these protocols face critical limitations in medical environments, including electro-magnetic interference (EMI) with sensitive equipment and high power consumption [7,8].”
Costin, H. P., Brehar, F.-M., Corlatescu, A.-D., & Pruna, V. M. (2025) · Biomedicines · doi:10.3390/biomedicines13112691 · Cited by 4
“…scanners, generating unintended currents that can temporarily stop the IPG and reset the parameters, or in some extreme cases, focal radiofrequency heating can occur at the electrode tip, with reported thalamic lesions, dysarthria, hemiparesis, or other irreversible neurological deficits [87].”
Oh, M., Kim, E., Choi, S.-H., Lee, J., Lee, S., Lee, J., Lee, J., Lee, J., Kwak, M., & Park, J. (2025) · ACS Nano · doi:10.1021/acsnano.5c15409 · Cited by 4
Electrosurgery and energised dissection
Adepoju, O., & Monaghan, E. (2023) · Surgery (Oxford) · doi:10.1016/j.mpsur.2022.12.003 · Cited by 3
Experimental Investigation of Focused Ultrasound Transmission through Rat Skulls
Hussain, S., Heo, H., Zeng, Y., Zhou, Q., & Jing, Y. (2025) · Advanced Devices & Instrumentation · doi:10.34133/adi.0122 · Cited by 3
Analysis of Adverse Event Reports in FDA’s MAUDE Database
Zisimopoulos, S., & Pallikarakis, N. E. (2023) · Global Clinical Engineering Journal · doi:10.31354/globalce.v6i1.157 · Cited by 3
Morano, J. M., Uejima, J. L., Tung, A., & Rosenow, J. M. (2023) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000001296 · Cited by 2
Hao, D., Yeung, G., Lee, H., Chen, Z., Laplante, B., Kitei, P. M., Ehsanian, R., Levi, D., Hao, D., Lee, H., et al. (2025) · Interventional Pain Medicine · doi:10.1016/j.inpm.2025.100650 · Cited by 2
Banik, R. K., Peng, S., Kohan, L. R., Rana, P. H., Darrow, D., & Hagedorn, J. M. (2022) · Pain Medicine · doi:10.1093/pm/pnac179 · Cited by 2
Baskovski, E., Atan, Ş., & Ersoy, İ. (2023) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2023.01.004 · Cited by 2
Telemedicine and implanted brain stimulation devices: a review of legal issues
Oliviero, E., Schmitz‐Luhn, B., Mestre, T., & Chandler, J. A. (2024) · Health and Technology · doi:10.1007/s12553-024-00821-2 · Cited by 2
“Concerns have also been raised about intentional exploitation of vulnerabilities in DBS systems (“brain-jack-ing”) [26] as well as inadvertent harm and disruption (e.g., impact of electro-magnetic interference on DBS devices) [27].”
Perioperative Management of Implantable Devices
Kalra, S. K., Singh, S., Grawe, E. S., Keshock, M. C., Bentov, N., & Richman, D. C. (2025) · International Anesthesiology Clinics · doi:10.1097/aia.0000000000000475 · Cited by 2
“20 Short-wave diathermy, also known as radio-wave diathermy or high-frequency diathermy, is a physical therapy treatment that uses electromagnetic waves to create heat in muscle or joint tissues.”
Qu, Y. D., Wang, J., Xu, R., Feng, Z., & Li, Z. (2025) · Materials Today Communications · doi:10.1016/j.mtcomm.2025.112794 · Cited by 2
Al-Husinat, L., Al-Bataineh, M., Hayajneh, R., Haneyah, D., Alrawabdeh, Q., Melhem, R. B., Sharei, A. A., Ismail, M. I. A., Azzam, S., Sharie, S. A., et al. (2025) · Frontiers in Medicine · doi:10.3389/fmed.2025.1683991 · Cited by 2
“The majority of the adjustments are performed on an outpatient basis without surgery, whereas surgical revision is only required in cases of hardware malfunction or battery depletion (33, 34).”
InfluentialMovement disorder Deep brain stimulation Hybridization: Patient and caregiver outcomes
Esplin, N. E., Kusyk, D. M., Jeong, S. W., Elhamdani, S., Aziz, K., Webb, A., Angle, C., Whiting, D. M., & Tomycz, N. D. (2024) · Clinical Parkinsonism & Related Disorders · doi:10.1016/j.prdoa.2024.100234 · Cited by 1
“The major manufacturers maintain strict policies of MRI conditionality for their respective systems, with limitations on field strength and other parameters of scanning [5,32,37,38].”
BackgroundInfluentialQadir, M. B., Shahzad, A., Ali, Z., Khaliq, Z., Irfan, M., Afzal, A., Ahmed, A., & Jumah, A. B. (2025) · Journal of Engineered Fibers and Fabrics · doi:10.1177/15589250251346269 · Cited by 1
“7,8 Different methods have been developed to mitigate the effects of EMI for the safety of electronic and biological systems.”
Arakawa, R., Kang, K., Sterner, I., Seemiller, J., Currens, L., Khamishon, R., Salimpour, Y., Mills, K., & Pantelyat, A. Y. (2026) · PLoS ONE · doi:10.1371/journal.pone.0344290 · Cited by 1
Beyond Innovation: The Burdens and Harms of Maintenance in Deep Brain Stimulation
Pateraki, M., & Gilbert, F. (2026) · Science and Engineering Ethics · doi:10.1007/s11948-026-00628-6 · Cited by 1
Brain-Computer Interface: Attack Surface Analysis
Triche, A., & Momin, M. A. A. (2021) · Advances in web technologies and engineering book series · doi:10.4018/978-1-7998-7323-5.ch010 · Cited by 1
Technological developments in electric-based DBS
Tönge, M. (2023) · Deep Brain Stimulation · doi:10.1016/j.jdbs.2023.12.001 · Cited by 1
Neuro-WiFi: Will It Be an Icebreaking Target for Neurological Diseases?
Pinto, J. B. (2023) · Science Insights · doi:10.15354/si.23.co157 · Cited by 1
Rimmer, M. (2012) · QUT ePrints (Queensland University of Technology) · Cited by 1
Sasaki, M., Higuchi, Y., Takada, M., Ikeda, J., Yamamoto, T., Hirano, S., & Iwadate, Y. (2022) · Japanese Journal of Neurosurgery · doi:10.7887/jcns.31.725
Anesthesia management in patients with neurostimulators
Rathore, A., Dinsmore, M., & Venkatraghavan, L. (2023) · International Anesthesiology Clinics · doi:10.1097/aia.0000000000000407
“Some of these devices can damage the IPG directly by transferring inductive, conductive, or radiated energy.(25) As a result, stimulation can be suppressed or increased or output can be completely stopped.”
BackgroundAn unusual case of myoclonic convulsions after surgical intervention for essential tremor
Douglas-Vail, M. B., Parmar, H. R., & Migneault, D. (2023) · Canadian Journal of Emergency Medicine · doi:10.1007/s43678-023-00560-9
“There are case reports of DBS units being deactivated or malfunctioning when in proximity to magnets, although this depends on the manufacturer of the DBS unit [4].”
BackgroundA Look into the Vulnerable Future of Medical Devices Through Assessment of a tDCS Gaming Device
Drabkin, A., & Pelletier, J. (2023) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah57547.2023.10253781
“Security concerns arise from the unsupervised modification of the patient’s treatment plan, indirectly through electromagnetic interference, or directly through an attacker having access to the device [4].”
Care of Patients with Parkinson's Disease after Deep Brain Stimulation: The Role of Nursing Staff
Raissova, K., Uakkazy, G., Shashkin, C., Akhmadeeva, G. N., & Alaidarova, M. (2023) · Journal of Health Development · doi:10.32921/2225-9929-2023-3-52-11-17
Deep Brain Stimulation - Efficacy and Safety for Neurological Treatments
Pei, Z. (2024) · E3S Web of Conferences · doi:10.1051/e3sconf/202455305013
DBS in the treatment of Parkinson’s disease
Szeidl, O., Szydziak, J., Hrapkowicz, A., Janowska, K., Rehan, D., Wołoszczak, J., Mioskowska, A., & Dąbkowska, D. (2024) · Quality in Sport · doi:10.12775/qs.2024.31.55864
“The distal cable is made of a nickel-cobalt alloy, embedded in ethylene-tetrafluoroethylene, and covered with polycarbonate polyurethane [12].”
Weise, F., Schaumann, K., Volpert, S., Slotty, P. J., Vesper, J., & Klenzner, T. (2024) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2024.10.001
Music Medicine for Neurological Disorders
Chauhan, N. B., Kale, M., Gujar-Kale, P., Desai, M., Jain, D. K., & Iyer, A. (2024) · Integrated science · doi:10.1007/978-3-031-73061-0_26
Perioperative Management of Noncardiac Implanted Medical Devices
Coleman, J. R., Lindenbaum, L., Hastad, N., & Hanson, N. A. (2025) · Advances in Anesthesia · doi:10.1016/j.aan.2025.07.004
Saputri, D. D., Saraswati, T. E., & Raharjo, W. W. (2025) · ALCHEMY Jurnal Penelitian Kimia · doi:10.20961/alchemy.21.2.97322.224-240
“…could lead to severe damage to communication systems (Solkin, 2021), disruption of aircraft control systems (Leuchter et al ., 2021), automotive safety systems (Mitilineos et al ., 2021), medical devices (Chan et al ., 2020; Rahimpour et al ., 2021), and electronic devices (Shan et al ., 2022).”
DBS-hoidon opas liikehäiriösairautta sairastavalle
Luoma, W., & Nivala, R. (2025) · Theseus (Ammattikorkeakoulujen)
Qiao, F., Guo, Y., Dong, Y., Song, K., Yan, B., & Zhou, J. (2026) · Journal of Central Nervous System Disease · doi:10.1177/11795735261415705
“27 To mitigate these shortcomings, Non-Invasive Brain Stimulation (NIBS) has emerged: it modulates brain and neuronal activity through physical (electrical, magnetic, optical, ultrasonic) or chemical methods targeting speci fi c brain regions-without the need for tissue incision.”
Pawliczak, E. E., Prisaznuk, J. M., & Chiarot, P. R. (2026) · Journal of Electronic Packaging · doi:10.1115/1.4071218
Saini, A., & Doshi, P. P. (2026) · Indian Journal of Pain · doi:10.4103/ijpn.ijpn_139_24
Freund, B. E., Vijayanarasimhan, V., Safa, A., Ekert, J. O., Colella, F. E., Block, C. K., Sabsevitz, D. S., Perez‐Vega, C., Middlebrooks, E. H., Mirsattari, S. M., et al. (2026) · Journal of Neurosurgery Case Lessons · doi:10.3171/case26376
“32,33 45 They may also generate radiofrequency-induced magnetic fields that could trigger spontane - ous reactivation of the stimulator.”
Gamma Knife radiosurgery in patients with indwelling deep brain stimulator systems
Qiang, Z., Bragg, C., & Yianni, J. (2026) · British Journal of Neurosurgery · doi:10.1080/02688697.2026.2727102
McIntosh, M. K., Potvin, C. D., Flynn, P. A., Klassen, A. B., & Weise, L. M. (2026) · Interdisciplinary Neurosurgery · doi:10.1016/j.inat.2026.102360
Skandalakis, G. P., Koutsarnakis, C., Evans, L. T., Hong, J., Simmons, N. E., Lozano, A. M., & Kalyvas, A. (2026) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2026.1982557
Thapa, N., Rabadi, M. J., Jabour, C. G., Goodlett, E. A., Lieberman, R. B., & Wasoff, A. L. (2026) · doi:10.5348/100023z18nt2026cr
Wiśniewski, J., Marcinkowska, A. B., Liczbik, O., Winklewski, P. J., & Wasilewski, W. (2026) · Research Square · doi:10.21203/rs.3.rs-11020975/v1
Safety and Considerations of Electroconvulsive Therapy in Patients With Implantable Devices
Robles, C. R. F., Tanella, A., & Fernandez-Robles, C. G. (2026) · International Anesthesiology Clinics · doi:10.1097/aia.0000000000000543
Metadata
- Authors
- Rahimpour, S., Kiyani, M., Hodges, S. E., & Turner, D. A.
- Affiliations
- Duke University (US)
- Duke Medical Center (US)
- Corresponding author
- Rahimpour, Shervin
- Venue
- Clinical Neurology and Neurosurgery
- Publisher
- Elsevier BV
- Published
- 2021-04
- Volume
- 203
- Pages
- 106577
- ISSN
- 0303-8467 (ISSN-L)
- PMC
- PMC8081063
- OpenAlex
- W3131287423
- Semantic Scholar
- 50105d3884837932227e00d3bd8119f6b7e48cc3
- Cited by
- 63
- References
- 61
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 13 · 2023: 17 · 2022: 4 · 2021: 5
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- Clinical Neurology and Neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (UH3NS103468, UH3NS129898)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Neurology › Transcranial Magnetic Stimulation Studies
- Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
- Keywords
- deep brain stimulation, electromagnetic interference, MRI safety, electrosurgery, MAUDE database, movement disorders, epilepsy, obsessive-compulsive disorder
- MeSH terms
- Electromagnetic Fields, Electronics, Humans, Deep Brain Stimulation, Implantable Neurostimulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.