Deep brain stimulation and electromagnetic interference
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Deep brain stimulation (DBS) has evolved into an approved and efficacious treatment for movement, obsessive-compulsive, and epilepsy disorders that are refractory to medical therapy, with current investigation into other disease conditions. However, there are unintentional and intentional sources of external electromagnetic interference (EMI) that can lead to either malfunctioning or damaged DBS devices, as well as injury to human tissue. Comprehensive studies and guidelines on such topics in the medical literature are scarce. Herein, we review the principles behind EMI, as well as the various potential sources of interference, both unintentional (e.g. stray EMI fields) and intentional (e.g. MRI scans, "brainjacking"). Additionally, we employ the Manufacturer and User Device Facility Experience (MAUDE) database to assess real-world instances of EMI (e.g., airport body scanners, magnetic resonance imaging (MRI), and electrosurgery) affecting DBS devices commonly implanted in the United States (US).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, RF systems for charging may induce voltages in nearby data circuits, causing data loss or errors, while power harvesting in battery-less systems might disrupt high-frequency data signals (Bazaka and Jacob, 2012; Rahimpour et al., 2021; Won et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Rahimpour et al., 2021
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, RF systems for charging may induce voltages in nearby data circuits, causing data loss or errors, while power harvesting in battery-less systems might disrupt high-frequency data signals (Bazaka and Jacob, 2012; Rahimpour et al., 2021; Won et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Rahimpour et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
A Randomized Trial of Deep-Brain Stimulation for Parkinson's Disease
Deuschl, G., Schade-Brittinger, C., Krack, P., Volkmann, J., Schäfer, H., Bötzel, K., Daniels, C., Deutschländer, A., Dillmann, U., Eisner, W., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060281 · Cited by 2,944
Bilateral Deep-Brain Stimulation of the Globus Pallidus in Primary Generalized Dystonia
Vidailhet, M., Vercueil, L., Houeto, J.-L., Krystkowiak, P., Benabid, A.-L., Cornu, P., Lagrange, C., Tézenas du Montcel, S., Dormont, D., Grand, S., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa042187 · Cited by 1,094
Chronic Anterior Thalamus Stimulation for Intractable Epilepsy
Hodaie, M., Wennberg, R. A., Dostrovsky, J. O., & Lozano, A. M. (2002) · Epilepsia · doi:10.1046/j.1528-1157.2002.26001.x · Cited by 605
MR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Electrotherapy Explained: Principles and Practice
Robertson, V. J., Ward, A., Low, J. N., & Reed, A. M. (1991) · Cited by 334
Directional deep brain stimulation: an intraoperative double-blind pilot study
Pollo, C., Kaelin-Lang, A., Oertel, M. F., Stieglitz, L., Taub, E., Fuhr, P., Lozano, A. M., Raabe, A., & Schüpbach, M. (2014) · Brain · doi:10.1093/brain/awu102 · Cited by 327 · cited 1×
“Besides two cylindrical electrodes, the 8CH has two central contacts consisting of three segments each, which can be activated independently to concentrate stimulation in one direction, thereby theoretically reducing current needed to produce meaningful therapeutic effects by up to 43 % [11].”
BackgroundHenderson, J. M., Tkach, J., Phillips, M., Baker, K., Shellock, F. G., & Rezai, A. R. (2005) · Neurosurgery · doi:10.1227/01.neu.0000180810.16964.3e · Cited by 314 · cited 1×
“Examples of reported consequences of EMI include: (1) development of unexpected thalamic lesions, secondary to cardioversion [19]; (2) aphasia, dysarthria, and hemiparesis, resulting from a radiofrequency lesion produced by heating of a DBS electrode during MRI of the lumbar spine [20]; and even (3) persistent vegetat…”
BackgroundSecurity and privacy issues in implantable medical devices: A comprehensive survey
Camara, C., Peris-Lopez, P., & Tapiador, J. E. (2015) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.04.007 · Cited by 293
Interference with Cardiac Pacemakers by Cellular Telephones
Hayes, D. L., Wang, P. J., Reynolds, D. W., Estes, N. A. M., Griffith, J. L., Steffens, R. A., Carlo, G. L., Findlay, G. K., & Johnson, C. M. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705223362101 · Cited by 282 · cited 1×
“These devices are known to be potential sources of interference with pacemakers and defibrillators; however, very little is known regarding interference with DBS [29,30].”
Background
Research works printed but not linked: 3
- Arle J, Shils JL (Eds.), Essential Neuromodulation, Academic Press, 2011, pp. 325– 348. Apr 14. Chapter 15.
- SJM, Lead and Extension Kits for Deep Brain Stimulation Systems – Clinician’s Manual, 2017, pp. 1– 50 (null).
- Kainz W, Alesch F, Chan DD, Electromagnetic interference of GSM mobile phones with the implantable deep brain stimulator, ITREL-III, Biomed. Eng. Online 2 (2003) 11. 12773204 PMC156641 · DOI · Paper page
Cited by
A review on electromagnetic shielding magnesium alloys
Liu, L., Chen, X., & Pan, F. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.10.001 · Cited by 193
Zhang, T., Pan, N., Wang, Y., Liu, C., & Hu, S. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.749162 · Cited by 177
Advancements in 3D-printed architectures for electromagnetic interference shields
Zhang, G., Wang, H., Xie, W., Zhou, S., Nie, Z., Niwamanya, G., Zhao, Z., & Duan, H. (2024) · Journal of Materials Chemistry A · doi:10.1039/d3ta07181b · Cited by 61
Excitatory‐inhibitory modulation of transcranial focus ultrasound stimulation on human motor cortex
Zhang, T., Guo, B., Zuo, Z., Long, X., Hu, S., Li, S., Su, X., Wang, Y., & Liu, C. (2023) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.14303 · Cited by 60
Li, J., Zhong, L., Wang, J., Feng, Z., Qu, Y. D., & Xu, R. (2024) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2024.03.013 · Cited by 44
Metadata
- Authors
- Rahimpour, S., Kiyani, M., Hodges, S. E., & Turner, D. A.
- Affiliations
- Duke University (US)
- Duke Medical Center (US)
- Corresponding author
- Rahimpour, Shervin
- Venue
- Clinical Neurology and Neurosurgery
- Publisher
- Elsevier BV
- Published
- 2021-04
- Volume
- 203
- Pages
- 106577
- ISSN
- 0303-8467 (ISSN-L)
- PMC
- PMC8081063
- OpenAlex
- W3131287423
- Semantic Scholar
- 50105d3884837932227e00d3bd8119f6b7e48cc3
- Cited by
- 63
- References
- 61
- Citations by year
- 2026: 11 · 2025: 12 · 2024: 13 · 2023: 17 · 2022: 4 · 2021: 5
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
- Locations
- Clinical Neurology and Neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (UH3NS103468, UH3NS129898)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Life Sciences › Neuroscience › Neurology › Transcranial Magnetic Stimulation Studies
- Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
- Keywords
- deep brain stimulation, electromagnetic interference, MRI safety, electrosurgery, MAUDE database, movement disorders, epilepsy, obsessive-compulsive disorder
- MeSH terms
- Electromagnetic Fields, Electronics, Humans, Deep Brain Stimulation, Implantable Neurostimulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.