Windows into human health through wearables data analytics
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Background: Wearable sensors (wearables) have been commonly integrated into a wide variety of commercial products and are increasingly being used to collect and process raw physiological parameters into salient digital health information. The data collected by wearables are currently being investigated across a broad set of clinical domains and patient populations. There is significant research occurring in the domain of algorithm development, with the aim of translating raw sensor data into fitness- or health-related outcomes of interest for users, patients, and health care providers. Objectives: The aim of this review is to highlight a selected group of fitness- and health-related indicators from wearables data and to describe several algorithmic approaches used to generate these higher order indicators. Methods: A systematic search of the Pubmed database was performed with the following search terms (number of records in parentheses): Fitbit algorithm (18), Apple Watch algorithm (3), Garmin algorithm (5), Microsoft Band algorithm (8), Samsung Gear algorithm (2), Xiaomi MiBand algorithm (1), Huawei Band (Watch) algorithm (2), photoplethysmography algorithm (465), accelerometry algorithm (966), ECG algorithm (8287), continuous glucose monitor algorithm (343). The search terms chosen for this review are focused on algorithms for wearable devices that dominated the commercial wearables market between 2014-2017 and that were highly represented in the biomedical literature. A second set of search terms included categories of algorithms for fitness-related and health-related indicators that are commonly used in wearable devices (e.g. accelerometry, PPG, ECG). These papers covered the following domain areas: fitness; exercise; movement; physical activity; step count; walking; running; swimming; energy expenditure; atrial fibrillation; arrhythmia; cardiovascular; autonomic nervous system; neuropathy; heart rate variability; fall detection; trauma; behavior change; diet; eating; stress detection; serum glucose monitoring; continuous glucose monitoring; diabetes mellitus type 1; diabetes mellitus type 2. All studies uncovered through this search on commercially available device algorithms and pivotal studies on sensor algorithm development were summarized, and a summary table was constructed using references generated by the literature review as described (Table 1). Conclusions: Wearable health technologies aim to collect and process raw physiological or environmental parameters into salient digital health information. Much of the current and future utility of wearables lies in the signal processing steps and algorithms used to analyze large volumes of data. Continued algorithmic development and advances in machine learning techniques will further increase analytic capabilities. In the context of these advances, our review aims to highlight a range of advances in fitness- and other health-related indicators provided by current wearable technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By contrast, data-driven methods have the potential to augment our capabilities in extracting patterns and relationships without squandering the potential of data fusion166–170.”
From End-to-end design of wearable sensors (2022) · cites this paper as [166]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Hinton, G., Deng, L., Yu, D., Dahl, G., Mohamed, A.-R., Jaitly, N., Senior, A., Vanhoucke, V., Nguyen, P., Sainath, T., et al. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2205597 · Cited by 10,260
The Physical Activity Guidelines for Americans
Piercy, K. L., Troiano, R. P., Ballard, R. M., Carlson, S. A., Fulton, J. E., Galuska, D. A., George, S. M., & Olson, R. D. (2018) · JAMA · doi:10.1001/jama.2018.14854 · Cited by 9,755
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
Artificial intelligence in healthcare: past, present and future
Jiang, F., Jiang, Y., Zhi, H., Dong, Y., Li, H., Ma, S., Wang, Y., Dong, Q., Shen, H., & Wang, Y. (2017) · Stroke and Vascular Neurology · doi:10.1136/svn-2017-000101 · Cited by 4,837
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Economic Costs of Diabetes in the U.S. in 2002
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.3.917 · Cited by 4,147
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Research works printed but not linked: 93
- Eapen, 2016, Defining a mobile health roadmap for cardiovascular health and disease, J Am Heart Assoc, 5
- Wolff-Hughes, 2014, Population-referenced percentiles for waist-worn accelerometer-derived total activity counts in U.S. youth: 2003 - 2006 NHANES, PLoS One, 9, e115915, 10.1371/journal.pone.0115915 · DOI · Paper page
- Maxmen, 2017, Google spin-off deploys wearable electronics for huge health study, Nature, 547, 13, 10.1038/547013a · doi:10.1038/547013a
- Roh, 2014, Wearable depression monitoring system with heart-rate variability, Conf Proc IEEE Eng Med Biol Soc, 2014, 562
- Carreiro, 2015, Real-time mobile detection of drug use with wearable biosensors: a pilot study, J Med Toxicol, 11, 73, 10.1007/s13181-014-0439-7 · DOI
- Celka, 2005, Wearable biosensing: signal processing and communication architectures issues, Journal of Telecommunications and Information Technology, 15
- Luo, 2016, Big data application in biomedical research and health care: a literature review, Biomed Inform Insights, 8, 1, 10.4137/BII.S31559 · DOI · Paper page
- Xiong, 2015, RNA splicing. The human splicing code reveals new insights into the genetic determinants of disease, Science, 347, 1254806, 10.1126/science.1254806 · DOI · Paper page
- Tompson, 2014, Joint training of a convolutional network and a graphical model for human pose estimation, Proc Adv Neural Inform Proc Syst, 27, 1799
- Mikolov, 2011, Strategies for training large scale neural network language models, Proc Automat Speech Recogn Understand, 196
- Aziz, 2017, Validation of accuracy of SVM-based fall detection system using real- world fall and non-fall datasets, PLoS One, 12, e0180318, 10.1371/journal.pone.0180318 · DOI · Paper page
- Dinh, 2009, A fall and near-fall assessment and evaluation system, Open Biomed Eng J, 3, 1, 10.2174/1874120700903010001 · DOI
- Nukala, 2016, Real-time classification of patients with balance disorders vs. Normal subjects using a low-cost small wireless wearable gait sensor, Biosensors (Basel), 6
- Mirmahboub, 2013, Automatic monocular system for human fall detection based on variations in silhouette area, IEEE Trans Biomed Eng, 60, 427, 10.1109/TBME.2012.2228262 · DOI
- Xi, 2017, Evaluation of feature extraction and recognition for activity monitoring and fall detection based on wearable sEMG sensors, Sensors (Basel), 17, 10.3390/s17061229 · DOI · Paper page
- Ozdemir, 2014, Detecting falls with wearable sensors using machine learning techniques, Sensors (Basel), 14, 10691, 10.3390/s140610691 · DOI · Paper page
- Gilani, 2016, Automated detection of atrial fibrillation episode using novel heart rate variability features, Conf Proc IEEE Eng Med Biol Soc, 2016, 3461
- Smisek, 2018, Multi-stage SVM approach for cardiac arrhythmias detection in short single-lead ECG recorded by a wearable device, Physiol Meas, 39, 094003, 10.1088/1361-6579/aad9e7 · DOI
- Nemati, 2016, Monitoring and detecting atrial fibrillation using wearable technology, Conf Proc IEEE Eng Med Biol Soc, 2016, 3394
- Ireland, 2016, Classification of movement of people with Parkinsons disease using wearable inertial movement units and machine learning, Stud Health Technol Inform, 227, 61
- Rovini, 2018, Comparative motor pre-clinical assessment in Parkinson's disease using supervised machine learning approaches, Ann Biomed Eng, 46, 2057, 10.1007/s10439-018-2104-9 · DOI
- Woodbridge, 2012, Aggregated indexing of biomedical time series data, Proc IEEE Int Conf Healthc Inform Imag Syst Biol, 2012, 23
- Barnett, 2018, Beyond smartphones and sensors: choosing appropriate statistical methods for the analysis of longitudinal data, J Am Med Inform Assoc, 10.1093/jamia/ocy121 · DOI · Paper page
- Warburton, 2006, Prescribing exercise as preventive therapy, CMAJ, 174, 961, 10.1503/cmaj.1040750 · DOI · Paper page
- Ahola, 2010, Pedometer for running activity using accelerometer sensors on the wrist, Med Equip Insights, 3
- Storm, 2015, Step detection and activity recognition accuracy of seven physical activity monitors, PLoS One, 10, e0118723, 10.1371/journal.pone.0118723 · DOI · Paper page
- Beevi, 2016, An evaluation of commercial pedometers for monitoring slow walking speed populations, Telemed J e Health, 22, 441, 10.1089/tmj.2015.0120 · DOI · Paper page
- Madigan, 2017, Fitness band accuracy in older community dwelling adults, Health Informatics J
- Chandrasekar, 2018, Preliminary concurrent validity of the Fitbit-Zip and ActiGraph activity monitors for measuring steps in people with polymyalgia rheumatica, Gait Posture, 61, 339, 10.1016/j.gaitpost.2018.01.035 · DOI
- Gaglani, 2015, Using commercial activity monitors to measure gait in patients with suspected iNPH: implications for ambulatory monitoring, Cureus, 7
- Winfree, 2018, Modeling clinically validated physical activity assessments using commodity hardware, IEEE J Biomed Health Inform, 22, 335, 10.1109/JBHI.2017.2787461 · DOI
- Schneider, 2016, Validation of the Fitbit Zip for monitoring physical activity among free-living adolescents, BMC Res Notes, 9, 448, 10.1186/s13104-016-2253-6 · DOI · Paper page
- Mooney, 2017, Evaluation of the Finis Swimsense(R) and the Garmin Swim activity monitors for swimming performance and stroke kinematics analysis, PLoS One, 12, e0170902, 10.1371/journal.pone.0170902 · DOI
- Cunningham, 1980, Calculation of the average energy absorbed in photon interactions, Med Phys, 7, 51, 10.1118/1.594658 · doi:10.1118/1.594658
- Jette, 1990, Metabolic equivalents (METS) in exercise testing, exercise prescription, and evaluation of functional capacity, Clin Cardiol, 13, 555, 10.1002/clc.4960130809 · DOI · Paper page
- Ceesay, 1989, The use of heart rate monitoring in the estimation of energy expenditure: a validation study using indirect whole-body calorimetry, Br J Nutr, 61, 175, 10.1079/BJN19890107 · DOI · Paper page
- Schutz, 2001, Assessment of free-living physical activity in humans: an overview of currently available and proposed new measures, Obes Res, 9, 368, 10.1038/oby.2001.48 · DOI · Paper page
- Pande, 2015, Using smartphone sensors for improving energy expenditure estimation, IEEE J Transl Eng Health Med, 3, 2700212, 10.1109/JTEHM.2015.2480082 · DOI
- Roos, 2017, Validity of sports watches when estimating energy expenditure during running, BMC Sports Sci Med Rehabil, 9, 22, 10.1186/s13102-017-0089-6 · DOI
- Ashman, 2017, Characteristics of office-based physician visits, 2014, NCHS Data Brief, 1
- Turakhia, 2015, Feasibility of extended ambulatory electrocardiogram monitoring to identify silent atrial fibrillation in high-risk patients: the Screening Study for Undiagnosed Atrial Fibrillation (STUDY-AF), Clin Cardiol, 38, 285, 10.1002/clc.22387 · DOI · Paper page
- Aboy, 2005, An automatic beat detection algorithm for pressure signals, IEEE Trans Biomed Eng, 52, 1662, 10.1109/TBME.2005.855725 · DOI · Paper page
- Lewis, 2011, Screening for atrial fibrillation: sensitivity and specificity of a new methodology, Br J Gen Pract, 61, 38, 10.3399/bjgp11X548956 · DOI · Paper page
- Bonomi, 2018, Atrial fibrillation detection using a novel cardiac ambulatory monitor based on photo-plethysmography at the wrist, J Am Heart Assoc, 7, e009351, 10.1161/JAHA.118.009351 · DOI · Paper page
- Lee J, 2012, Atrial fibrillation detection using a smart phone, Conf Proc IEEE Eng Med Biol Soc, 2012, 1177
- Corino, 2017, Detection of atrial fibrillation episodes using a wristband device, Physiol Meas, 38, 787, 10.1088/1361-6579/aa5dd7 · DOI · Paper page
- January, 2014, 2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American college of cardiology/American heart association task force on practice guidelines and the heart rhythm society, Circulation, 130, e199
- Asgari, 2015, Automatic detection of atrial fibrillation using stationary wavelet transform and support vector machine, Comput Biol Med, 60, 132, 10.1016/j.compbiomed.2015.03.005 · DOI · Paper page
- Xu, 2018, Atrial fibrillation beat identification using the combination of modified frequency slice wavelet transform and convolutional neural networks, J Healthc Eng, 2018, 2102918
- Fan, 2018, Multiscaled fusion of deep convolutional neural networks for screening atrial fibrillation from single lead short ECG recordings, IEEE J Biomed Health Inform, 22, 1744, 10.1109/JBHI.2018.2858789 · DOI · Paper page
- He, 2018, Automatic detection of atrial fibrillation based on continuous wavelet transform and 2D convolutional neural networks, Front Physiol, 9, 1206, 10.3389/fphys.2018.01206 · DOI
- Vandenberk, 2017, Clinical validation of heart rate apps: mixed-methods evaluation study, JMIR Mhealth Uhealth, 5, e129, 10.2196/mhealth.7254 · DOI · Paper page
- Hernandez-Silveira, 2015, Preliminary assessment of the SensiumVitals(R): a low- cost wireless solution for patient surveillance in the general wards, Conf Proc IEEE Eng Med Biol Soc, 2015, 4931
- Torfs, 2014, Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring, J Electrocardiol, 47, 881, 10.1016/j.jelectrocard.2014.08.012 · DOI
- De Meersman, 1993, Heart rate variability and aerobic fitness, Am Heart J, 125, 726, 10.1016/0002-8703(93)90164-5 · DOI · Paper page
- Molgaard, 1991, Circadian variation and influence of risk factors on heart rate variability in healthy subjects, Am J Cardiol, 68, 777, 10.1016/0002-9149(91)90653-3 · DOI
- Mani, 2009, Decreased heart rate variability in patients with cirrhosis relates to the presence and degree of hepatic encephalopathy, Am J Physiol Gastrointest Liver Physiol, 296, G330, 10.1152/ajpgi.90488.2008 · DOI · Paper page
- Griffin, 2001, Toward the early diagnosis of neonatal sepsis and sepsis-like illness using novel heart rate analysis, Pediatrics, 107, 97, 10.1542/peds.107.1.97 · DOI · Paper page
- Lucini, 2017, Heart rate variability to monitor performance in elite athletes: criticalities and avoidable pitfalls, Int J Cardiol, 240, 307, 10.1016/j.ijcard.2017.05.001 · DOI
- Cichosz, 2017, Are changes in heart rate variability during hypoglycemia confounded by the presence of cardiovascular autonomic neuropathy in patients with diabetes?, Diabetes Technol Ther, 19, 91, 10.1089/dia.2016.0342 · DOI
- Nocua, 2009, Evaluation of the autonomic nervous system for fall detection, Conf Proc IEEE Eng Med Biol Soc, 2009, 3225
- Reinertsen, 2018, Multiscale network dynamics between heart rate and locomotor activity are altered in schizophrenia, Physiol Meas, 39, 115001, 10.1088/1361-6579/aae1ed · DOI
- Axer, 2010, Falls and gait disorders in geriatric neurology, Clin Neurol Neurosurg, 112, 265, 10.1016/j.clineuro.2009.12.015 · DOI
- Gurley, 1996, Persons found in their homes helpless or dead, N Engl J Med, 334, 1710, 10.1056/NEJM199606273342606 · DOI · Paper page
- Khan, 2017, Review of fall detection techniques: a data availability perspective, Med Eng Phys, 39, 12, 10.1016/j.medengphy.2016.10.014 · DOI · Paper page
- Gao, 2014, Evaluation of accelerometer based multi-sensor versus single-sensor activity recognition systems, Med Eng Phys, 36, 779, 10.1016/j.medengphy.2014.02.012 · DOI · Paper page
- Nait Aicha, 2018, Deep learning to predict falls in older adults based on daily-life trunk accelerometry, Sensors (Basel), 18, 10.3390/s18051654 · DOI · Paper page
- Ozdemir, 2016, An analysis on sensor locations of the human body for wearable fall detection devices: principles and practice, Sensors (Basel), 16, 10.3390/s16081161 · DOI · Paper page
- Attal, 2015, Physical human activity recognition using wearable sensors, Sensors (Basel), 15, 31314, 10.3390/s151229858 · DOI · Paper page
- Cates, 2018, A novel detection model and its optimal features to classify falls from low- and high-acceleration activities of daily life using an insole sensor system, Sensors (Basel), 18, 10.3390/s18041227 · DOI
- Chaudhuri, 2015, Real-world accuracy and use of a wearable fall detection device by older adults, J Am Geriatr Soc, 63, 2415, 10.1111/jgs.13804 · DOI
- Tri Vu, 2017, Nabil Alshurafa, Wenyao Xu, wearable food intake monitoring technologies: a comprehensive review, Computers, 6, 1
- Amft, 2010, A wearable earpad sensor for chewing monitoring, Sensors
- Sazonov, 2010, Automatic detection of swallowing events by acoustical means for applications of monitoring of ingestive behavior, IEEE Trans Biomed Eng, 57, 626, 10.1109/TBME.2009.2033037 · DOI · Paper page
- Paavilainen, 2005, Circadian activity rhythm in demented and non-demented nursing- home residents measured by telemetric actigraphy, J Sleep Res, 14, 61, 10.1111/j.1365-2869.2004.00433.x · DOI · Paper page
- Wang, 2018, A low-power fall detector balancing sensitivity and false alarm rate, IEEE J Biomed Health Inform, 22, 1929, 10.1109/JBHI.2017.2778271 · DOI
- Dawadi, 2016, Modeling patterns of activities using activity curves, Pervasive Mob Comput, 28, 51, 10.1016/j.pmcj.2015.09.007 · DOI
- Liu, 2013, Change-point detection in time-series data by relative density-ratio estimation, Neural Netw, 43, 72, 10.1016/j.neunet.2013.01.012 · DOI · Paper page
- Korinek, 2018, Adaptive step goals and rewards: a longitudinal growth model of daily steps for a smartphone-based walking intervention, J Behav Med, 41, 74, 10.1007/s10865-017-9878-3 · DOI
- Merilahti, 2016, Wearable monitoring of physical functioning and disability changes, circadian rhythms and sleep patterns in nursing home residents, IEEE J Biomed Health Inform, 20, 856, 10.1109/JBHI.2015.2420680 · DOI
- Gjoreski, 2017, Monitoring stress with a wrist device using context, J Biomed Inform, 73, 159, 10.1016/j.jbi.2017.08.006 · DOI · Paper page
- Boostani, 2017, A comparative review on sleep stage classification methods in patients and healthy individuals, Comput Methods Programs Biomed, 140, 77, 10.1016/j.cmpb.2016.12.004 · DOI · Paper page
- Fraiwan, 2012, Automated sleep stage identification system based on time-frequency analysis of a single EEG channel and random forest classifier, Comput Methods Programs Biomed, 108, 10, 10.1016/j.cmpb.2011.11.005 · DOI · Paper page
- Lajnef, 2015, Learning machines and sleeping brains: automatic sleep stage classification using decision-tree multi-class support vector machines, J Neurosci Methods, 250, 94, 10.1016/j.jneumeth.2015.01.022 · DOI · Paper page
- Castner, 2018, Validation of fitness tracker for sleep measures in women with asthma, J Asthma, 1
- Baroni, 2016, Fitbit Flex: an unreliable device for longitudinal sleep measures in a non-clinical population, Sleep Breath, 20, 853, 10.1007/s11325-015-1271-2 · DOI
- Chen, 2017, Current and emerging technology for continuous glucose monitoring, Sensors (Basel), 17
- Kropff, 2017, Accuracy and longevity of an implantable continuous glucose sensor in the PRECISE study: a 180-day, prospective, multicenter, pivotal trial, Diabetes Care, 40, 63, 10.2337/dc16-1525 · DOI · Paper page
- Knobbe, 2005, The extended Kalman filter for continuous glucose monitoring, Diabetes Technol Ther, 7, 15, 10.1089/dia.2005.7.15 · DOI · Paper page
- Bequette, 2010, Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms, J Diabetes Sci Technol, 4, 404, 10.1177/193229681000400222 · DOI · Paper page
- Hamdi, 2018, Accurate prediction of continuous blood glucose based on support vector regression and differential evolution algorithm, Biocybernetics Biomed Engineering, 38, 362, 10.1016/j.bbe.2018.02.005 · DOI
- Mhaskar, 2017, A deep learning approach to diabetic blood glucose prediction, Front. Appl. Math. Stat., 3, 10.3389/fams.2017.00014 · DOI · Paper page
- Sprint, 2016, Unsupervised detection and analysis of changes in everyday physical activity data, J Biomed Inform, 63, 54, 10.1016/j.jbi.2016.07.020 · DOI
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673
Self-citationGoldsack, J. C., Coravos, A., Bakker, J. P., Bent, B., Dowling, A. V., Fitzer-Attas, C., Godfrey, A., Godino, J. G., Gujar, N., Izmailova, E., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0260-4 · Cited by 557
Self-citationA Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Pre-symptomatic detection of COVID-19 from smartwatch data
Mishra, T., Wang, M., Metwally, A. A., Bogu, G. K., Brooks, A. W., Bahmani, A., Alavi, A., Celli, A., Higgs, E., Dagan-Rosenfeld, O., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00640-6 · Cited by 463
Self-citationHybrid multimodal wearable sensors for comprehensive health monitoring
Mahato, K., Saha, T., Ding, S., Sandhu, S. S., Chang, A.-Y., & Wang, J. (2024) · Nature Electronics · doi:10.1038/s41928-024-01247-4 · Cited by 404
Data Integration Challenges for Machine Learning in Precision Medicine
Martínez-García, M., & Hernández-Lemus, E. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2021.784455 · Cited by 185
Biosensing in dermal interstitial fluid using microneedle based electrochemical devices
Madden, J., O'Mahony, C., Thompson, M., O'Riordan, A., & Galvin, P. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100348 · Cited by 161
A review of sampling, energy supply and intelligent monitoring for long-term sweat sensors
Yang, P., Wei, G., Liu, A., Huo, F., & Zhang, Z. (2022) · npj Flexible Electronics · doi:10.1038/s41528-022-00165-9 · Cited by 77
Metadata
- Authors
- Witt, D. R., Kellogg, R. A., Snyder, M. P., & Dunn, J.
- ORCID
- Kellogg, Ryan A.
- Venue
- Current Opinion in Biomedical Engineering
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 9
- Pages
- 28-46
- ISSN
- 2468-4511
- Cited by
- 157
- References
- 49
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- www.elsevier.com/open-access/userlicense/1.0/ (am, 365 d)
- Funders
- NIH (U54DK10255603, R01DK11018602)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.