The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Image quality in CT: From physical measurements to model observers
Open accessAbstract
Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
(1966) · Medical Entomology and Zoology · Cited by 10,293
(1932) · Medical Entomology and Zoology · Cited by 9,568
Signal detection theory and psychophysics
Ingleby, J. D. (1967) · Journal of Sound and Vibration · doi:10.1016/0022-460x(67)90197-6 · Cited by 8,509
Detection Theory: A User's Guide
Macmillan, N. A., & Creelman, C. D. (1991) · Cited by 5,415
Likert scales, levels of measurement, and the “laws” of statistics
Norman, G. (2010) · Advances in Health Sciences Education · doi:10.1007/s10459-010-9222-y · Cited by 4,850
Detection theory: A user's guide
Lories, G. (1993) · Behavioural Processes · doi:10.1016/0376-6357(93)90083-4 · Cited by 2,835
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065 · cited 1×
“A Bland–Altman plot is often used to compare results between model observers and human observers [113].”
MethodThe Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
Björck, Å., Dahlquist, G. G., & Anderson, N. (1974) · Cited by 1,719
Likert scales: how to (ab)use them
Jamieson, S. (2004) · Medical Education · doi:10.1111/j.1365-2929.2004.02012.x · Cited by 1,602
Organ printing: computer-aided jet-based 3D tissue engineering
Mironov, V., Boland, T., Trusk, T., Forgacs, G., & Markwald, R. R. (2003) · Trends in Biotechnology · doi:10.1016/s0167-7799(03)00033-7 · Cited by 1,276
Barrett, H. H., Myers, K. J., & Rathee, S. (2004) · Medical Physics · doi:10.1118/1.1677252 · Cited by 1,065
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Computed tomography : fundamentals, system technology, image quality, applications
Kalender, W. A. (2000) · Cited by 692
Model observers for assessment of image quality.
Barrett, H. H., Yao, J., Rolland, J. P., & Myers, K. J. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.21.9758 · Cited by 531
Signal detection and recognition by human observers : contemporary readings
Swets, J. A. (1964) · Wiley eBooks · Cited by 446
Richard, S., Husarik, D. B., Yadava, G., Murphy, S. N., & Samei, E. (2012) · Medical Physics · doi:10.1118/1.4725171 · Cited by 419
Assessment of display performance for medical imaging systems: Executive summary of AAPM TG18 report
Samei, E., Badano, A., Chakraborty, D., Compton, K., Cornelius, C., Corrigan, K., Flynn, M. J., Hemminger, B., Hangiandreou, N., Johnson, J., et al. (2005) · Medical Physics · doi:10.1118/1.1861159 · Cited by 410
Addition of a channel mechanism to the ideal-observer model
Myers, K. J., & Barrett, H. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.002447 · Cited by 400
Rose, A., & Biberman, L. (1975) · Physics Today · doi:10.1063/1.3069240 · Cited by 378
Abbey, C. K., & Barrett, H. H. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.000473 · Cited by 324
Effect of random background inhomogeneity on observer detection performance
Rolland, J. P., & Barrett, H. H. (1992) · Journal of the Optical Society of America A · doi:10.1364/josaa.9.000649 · Cited by 272
Computed Tomography: Physical Principles, Clinical Applications, and Quality Control
Seeram, E. (2015) · Cited by 262
Boone, J. M. (2012) · Medical Physics · doi:10.1118/1.4725757 · Cited by 247
A revised table of d’ for M-alternative forced choice
Hacker, M. J., & Ratcliff, R. (1979) · Perception & Psychophysics · doi:10.3758/bf03208311 · Cited by 243
SNR and DQE analysis of broad spectrum X-ray imaging
Tapiovaara, M. J., & Wagner, R. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/6/002 · Cited by 228
Self-citationStatistically defined backgrounds:performance of a modified nonprewhitening observer model
Burgess, A. E. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001237 · Cited by 187
Handbook of Medical Imaging, Volume 1. Physics and Psychophysics
(2000) · SPIE eBooks · doi:10.1117/3.832716 · Cited by 175
Recent Advances in CT Image Reconstruction
Hsieh, J., Nett, B. E., Zhou, Y., Sauer, K. D., Thibault, J., & Bouman, C. A. (2013) · Current Radiology Reports · doi:10.1007/s40134-012-0003-7 · Cited by 153
Visual signal detection II Signal-location identification
Burgess, A. E., & Ghandeharian, H. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000906 · Cited by 148
Objective assessment of image quality and dose reduction in CT iterative reconstruction
Vaishnav, J. Y., Jung, W.-G., Popescu, L. M., Zeng, R., & Myers, K. J. (2014) · Medical Physics · doi:10.1118/1.4881148 · Cited by 128
Loo, L. N. D., Doi, K., & Metz, C. E. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/7/007 · Cited by 100
Li, F., Aoyama, M., Shiraishi, J., Abé, H., Li, Q., Suzuki, K., Engelmann, R. M., Sone, S., MacMahon, H., & Doi, K. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.5.1831209 · Cited by 96
A Brief History of Free-Response Receiver Operating Characteristic Paradigm Data Analysis
Chakraborty, D. P. (2013) · Academic Radiology · doi:10.1016/j.acra.2013.03.001 · Cited by 76
Visual signal detectionIIIOn Bayesian use of prior knowledge and cross correlation
Burgess, A. E. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001498 · Cited by 75
Evaluation of internal noise methods for Hotelling observer models
Zhang, Y., Pham, B. T., & Eckstein, M. P. (2007) · Medical Physics · doi:10.1118/1.2756603 · Cited by 70
Human visual perception and ROC methodology in medical imaging
Chesters, M. S. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/001 · Cited by 63
Bochud, F. O., Abbey, C. K., & Eckstein, M. P. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000193 · Cited by 62
Self-citationAutomated assessment of low contrast sensitivity for CT systems using a model observer
Giron, I. H., Geleijns, J., Calzado, A., et al. (2011) · Medical Physics · doi:10.1118/1.3577757 · Cited by 54
Self-citationComputer-Aided Diagnosis of Lung Nodules on CT Scans:
Way, T. W., Chan, H., Hadjiiski, L. M., Sahiner, B., Chughtai, A. R., Song, T. K., Poopat, C., Stojanovska, J., Frank, L., Attili, A. K., et al. (2010) · Academic Radiology · doi:10.1016/j.acra.2009.10.016 · Cited by 47
Nonparametric signal detectability evaluation using an exponential transformation of the FROC curve
Popescu, L. M. (2011) · Medical Physics · doi:10.1118/1.3633938 · Cited by 31
A table ofd′ forM-alternative odd-man-out forced-choice procedures
Craven, B. (1992) · Perception & Psychophysics · doi:10.3758/bf03211631 · Cited by 19
Wunderlich, A., & Abbey, C. K. (2013) · Medical Physics · doi:10.1118/1.4823755 · Cited by 12
Cited by
Greffier, J., Hamard, A., Pereira, F., Barrau, C., Pasquier, H., Beregi, J. P., & Frandon, J. (2020) · European Radiology · doi:10.1007/s00330-020-06724-w · Cited by 328
Optimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
154, I. P. (2023) · Annals of the ICRP · doi:10.1177/01466453231210646 · Cited by 37
Simplified size adjusted dose reference levels for adult CT examinations: A regional study
Moghadam, N., Lecomte, R., Mercure, S., Rehani, M. M., & Nassiri, M. A. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109861 · Cited by 16
Metadata
- Authors
- Verdun, F. R., Racine, D., Ott, J. G., Tapiovaara, M. J., Toroi, P., Bochud, F. O., Veldkamp, W. J. H., Schegerer, A., Bouwman, R. W., Giron, I. H., Marshall, N. W., & Edyvean, S.
- Venue
- Physica Medica
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 31
- Issue
- 8
- Pages
- 823-843
- ISSN
- 1120-1797 (ISSN-L)
- OpenAlex
- W2195096812
- Cited by
- 300
- References
- 44
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.