The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Ambient and laboratory evaluation of a low-cost particulate matter sensor
Open accessAbstract
Low-cost, light-scattering-based particulate matter (PM) sensors are becoming more widely available and are being increasingly deployed in ambient and indoor environments because of their low cost and ability to provide high spatial and temporal resolution PM information. Researchers have begun to evaluate some of these sensors under laboratory and environmental conditions. In this study, a low-cost, particulate matter sensor (Plantower PMS 1003/3003) used by a community air-quality network is evaluated in a controlled wind-tunnel environment and in the ambient environment during several winter-time, cold-pool events that are associated with high ambient levels of PM. In the wind-tunnel, the PMS sensor performance is compared to two research-grade, light-scattering instruments, and in the ambient tests, the sensor performance is compared to two federal equivalent (one tapered element oscillating microbalance and one beta attenuation monitor) and gravimetric federal reference methods (FEMs/FRMs) as well as one research-grade instrument (GRIMM). The PMS sensor response correlates well with research-grade instruments in the wind-tunnel tests, and its response is linear over the concentration range tested (200–850 μg/m3). In the ambient tests, this PM sensor correlates better with gravimetric methods than previous studies with correlation coefficients of 0.88. However additional measurements under a variety of ambient conditions are needed. Although the PMS sensor correlated as well as the research-grade instrument to the FRM/FEMs in ambient conditions, its response varies with particle properties to a much greater degree than the research-grade instrument. In addition, the PMS sensors overestimate ambient PM concentrations and begin to exhibit a non-linear response when PM2.5 concentrations exceed 40 μg/m3. These results have important implications for communicating results from low-cost sensor networks, and they highlight the importance of using an appropriate correction factor for the target environmental conditions if the user wants to compare the results to FEM/FRMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution
Pope III, C. A. (2002) · JAMA · doi:10.1001/jama.287.9.1132 · Cited by 8,447
Brook, R. D., Rajagopalan, S., Pope, C. A., Brook, J. R., Bhatnagar, A., Diez-Roux, A. V., Holguin, F., Hong, Y., Luepker, R. V., Mittleman, M. A., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181dbece1 · Cited by 6,548
Aerosol Measurement: Principles, Techniques, and Applications
(2011) · Wiley eBooks · doi:10.1002/9781118001684 · Cited by 1,352
Schubert, E. F., Gessmann, T., & Kim, J. K. (2005) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1209070811091908.a01.pub2 · Cited by 1,244
Lepeule, J., Laden, F., Dockery, D., & Schwartz, J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104660 · Cited by 983
Fine particulate matter (PM2.5) in China at a city level
Zhang, Y.-L., & Cao, F. (2015) · Scientific Reports · doi:10.1038/srep14884 · Cited by 921
Aerosol measurement: Principles, techniques, and applications
Gutfinger, C. (1996) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(96)00006-7 · Cited by 887
Pope, C. A., Burnett, R. T., Turner, M. C., Cohen, A., Krewski, D., Jerrett, M., Gapstur, S. M., & Thun, M. J. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1103639 · Cited by 743
Air pollution and incidence of cardiac arrhythmia
Peters, A., Liu, E., Verrier, R. L., Schwartz, J., Gold, D. R., Mittleman, M., Baliff, J., Oh, J. A., Allen, G., Monahan, K., et al. (2000) · Epidemiology · doi:10.1097/00001648-200001000-00005 · Cited by 651
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Steinle, S., Reis, S., & Sabel, C. E. (2013) · Science of The Total Environment · doi:10.1016/j.scitotenv.2012.10.098 · Cited by 430
Bewertung und Vergleich von Analysenverfahren
Kaiser, H., & Specker, H. (1956) · Fresenius' Zeitschrift für analytische Chemie · doi:10.1007/bf00454145 · Cited by 356
Gao, M., Cao, J., & Seto, E. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.01.013 · Cited by 345
Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312
The next generation of low-cost personal air quality sensors for quantitative exposure monitoring
Piedrahita, R., Xiang, Y., Masson, N., Ortega, J., Collier, A., Jiang, Y., Li, K., Dick, R. P., Lv, Q., Hannigan, M., et al. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-3325-2014 · Cited by 283
Air quality in North America's most populous city – overview of the MCMA-2003 campaign
Molina, L. T., Kolb, C. E., de Foy, B., Lamb, B. K., Brune, W. H., Jimenez, J. L., Ramos-Villegas, R., Sarmiento, J., Paramo-Figueroa, V. H., Cardenas, B., et al. (2007) · Atmospheric Chemistry and Physics · doi:10.5194/acp-7-2447-2007 · Cited by 263
Whiteman, C. D., Hoch, S. W., Horel, J. D., & Charland, A. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.06.012 · Cited by 223
Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor
Austin, E., Novosselov, I., Seto, E., & Yost, M. G. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137789 · Cited by 167
Beard, J. D., Beck, C., Graham, R., Packham, S. C., Traphagan, M., Giles, R. T., & Morgan, J. G. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104349 · Cited by 107
Particle density inferred from simultaneous optical and aerodynamic diameters sorted by composition
Murphy, D. M., Cziczo, D. J., Hudson, P. K., Schein, M., & Thomson, D. S. (2003) · Journal of Aerosol Science · doi:10.1016/s0021-8502(03)00386-0 · Cited by 55
Kelly, K. E., Kotchenruther, R. A., Kuprov, R. Y., & Silcox, G. D. (2013) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2013.774819 · Cited by 54
Self-citationJuvenile idiopathic arthritis and exposure to fine particulate air pollution.
Zeft, A., Prahalad, S., LeFevre, S., Clifford, B., McNally, B., Bohnsack, J. F., & Pope, C. A. (2009) · PubMed · Cited by 49
Cited by
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-4823-2018 · Cited by 418
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1623863 · Cited by 343
Metadata
- Authors
- Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A.
- Venue
- Environmental Pollution
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 221
- Pages
- 491-500
- ISSN
- 0269-7491 (ISSN-L)
- OpenAlex
- W2566824844
- Cited by
- 498
- References
- 22
- FWCI
- 14.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.