The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Ambient and laboratory evaluation of a low-cost particulate matter sensor
Open accessAbstract
Low-cost, light-scattering-based particulate matter (PM) sensors are becoming more widely available and are being increasingly deployed in ambient and indoor environments because of their low cost and ability to provide high spatial and temporal resolution PM information. Researchers have begun to evaluate some of these sensors under laboratory and environmental conditions. In this study, a low-cost, particulate matter sensor (Plantower PMS 1003/3003) used by a community air-quality network is evaluated in a controlled wind-tunnel environment and in the ambient environment during several winter-time, cold-pool events that are associated with high ambient levels of PM. In the wind-tunnel, the PMS sensor performance is compared to two research-grade, light-scattering instruments, and in the ambient tests, the sensor performance is compared to two federal equivalent (one tapered element oscillating microbalance and one beta attenuation monitor) and gravimetric federal reference methods (FEMs/FRMs) as well as one research-grade instrument (GRIMM). The PMS sensor response correlates well with research-grade instruments in the wind-tunnel tests, and its response is linear over the concentration range tested (200–850 μg/m3). In the ambient tests, this PM sensor correlates better with gravimetric methods than previous studies with correlation coefficients of 0.88. However additional measurements under a variety of ambient conditions are needed. Although the PMS sensor correlated as well as the research-grade instrument to the FRM/FEMs in ambient conditions, its response varies with particle properties to a much greater degree than the research-grade instrument. In addition, the PMS sensors overestimate ambient PM concentrations and begin to exhibit a non-linear response when PM2.5 concentrations exceed 40 μg/m3. These results have important implications for communicating results from low-cost sensor networks, and they highlight the importance of using an appropriate correction factor for the target environmental conditions if the user wants to compare the results to FEM/FRMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution
Pope III, C. A. (2002) · JAMA · doi:10.1001/jama.287.9.1132 · Cited by 8,447
Brook, R. D., Rajagopalan, S., Pope, C. A., Brook, J. R., Bhatnagar, A., Diez-Roux, A. V., Holguin, F., Hong, Y., Luepker, R. V., Mittleman, M. A., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181dbece1 · Cited by 6,548
Aerosol Measurement: Principles, Techniques, and Applications
(2011) · Wiley eBooks · doi:10.1002/9781118001684 · Cited by 1,352
Schubert, E. F., Gessmann, T., & Kim, J. K. (2005) · Kirk-Othmer Encyclopedia of Chemical Technology · doi:10.1002/0471238961.1209070811091908.a01.pub2 · Cited by 1,244
Lepeule, J., Laden, F., Dockery, D., & Schwartz, J. (2012) · Environmental Health Perspectives · doi:10.1289/ehp.1104660 · Cited by 983
Fine particulate matter (PM2.5) in China at a city level
Zhang, Y.-L., & Cao, F. (2015) · Scientific Reports · doi:10.1038/srep14884 · Cited by 921
Aerosol measurement: Principles, techniques, and applications
Gutfinger, C. (1996) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(96)00006-7 · Cited by 887
Pope, C. A., Burnett, R. T., Turner, M. C., Cohen, A., Krewski, D., Jerrett, M., Gapstur, S. M., & Thun, M. J. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1103639 · Cited by 743
Air pollution and incidence of cardiac arrhythmia
Peters, A., Liu, E., Verrier, R. L., Schwartz, J., Gold, D. R., Mittleman, M., Baliff, J., Oh, J. A., Allen, G., Monahan, K., et al. (2000) · Epidemiology · doi:10.1097/00001648-200001000-00005 · Cited by 651
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Cited by
End-user perspective of low-cost sensors for outdoor air pollution monitoring
Rai, A. C., Kumar, P., Pilla, F., Skouloudis, A. N., Di Sabatino, S., Ratti, C., Yasar, A., & Rickerby, D. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.06.266 · Cited by 550
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-4823-2018 · Cited by 418
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1623863 · Cited by 343
Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Feenstra, B., Papapostolou, V., Hasheminassab, S., Zhang, H., Boghossian, B. D., Cocker, D., & Polidori, A. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2019.116946 · Cited by 265
Cesler‐Maloney, M., Simpson, W. R., Miles, T., Mao, J., Law, K. S., & Roberts, T. J. (2022) · Journal of Geophysical Research: Atmospheres · doi:10.1029/2021jd036215 · Cited by 36
Assessment of air quality sensor system performance after relocation
Zauli-Sajani, S., Marchesi, S., Pironi, C., Barbieri, C., Poluzzi, V., & Colacci, A. (2021) · Atmospheric Pollution Research · doi:10.1016/j.apr.2020.11.010 · Cited by 30
Metadata
- Authors
- Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A.
- Venue
- Environmental Pollution
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 221
- Pages
- 491-500
- ISSN
- 0269-7491 (ISSN-L)
- OpenAlex
- W2566824844
- Cited by
- 498
- References
- 22
- FWCI
- 14.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.