Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Permanent magnet synchronous motors (PMSMs) are applied in high performance positioning and variable speed applications because of their enhanced features with respect to other AC motor types. Fault detection and diagnosis of electrical motors for critical applications is an active field of research. However, much research remains to be done in the field of PMSM demagnetization faults, especially when running under non-stationary conditions. This paper presents a time–frequency method specifically focused to detect and diagnose demagnetization faults in PMSMs running under non-stationary speed conditions, based on the Hilbert Huang transform. The effectiveness of the proposed method is proven by means of experimental results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Detecting faults in rotors of PM drives
Roux, W., Harley, R., & Habetler, T. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.915789 · Cited by 48
Research works printed but not linked: 24
- Dai, 2005, Fault analysis of a PM brushless DC motor using finite element method, IEEE Trans. Energy Conv., 20, 1, 10.1109/TEC.2004.841516 · DOI · Paper page
- Razika, 2009, An induction machine model including interbar currents for studying, Electr. Power Syst. Res., 79, 181, 10.1016/j.epsr.2008.05.015 · doi:10.1016/j.epsr.2008.05.015
- Calıs, 2007, Rotor bar fault diagnosis in three phase induction motors by monitoring fluctuations of motor current zero crossing instants performances during transients and steady state, Electr. Power Syst. Res., 77, 385, 10.1016/j.epsr.2006.03.017 · doi:10.1016/j.epsr.2006.03.017
- Ye, 2006, Mechanical fault diagnostics for induction motor with variable speed drives using Adaptive Neuro-fuzzy Inference System, Electr. Power Syst. Res., 76, 742, 10.1016/j.epsr.2005.10.011 · doi:10.1016/j.epsr.2005.10.011
- Bacha, 2008, Induction machine fault detection using stray flux EMF measurement and neural network-based decision, Electr. Power Syst. Res., 78, 1247, 10.1016/j.epsr.2007.10.006 · doi:10.1016/j.epsr.2007.10.006
- Samsi, 2009, Early detection of stator voltage imbalance in three-phase induction motors, Electr. Power Syst. Res., 79, 239, 10.1016/j.epsr.2008.06.004 · doi:10.1016/j.epsr.2008.06.004
- Morel, 2008, A predictive current control applied to a permanent magnet synchronous machine, comparison with a classical direct torque control, Electr. Power Syst. Res., 78, 1437, 10.1016/j.epsr.2008.01.004 · doi:10.1016/j.epsr.2008.01.004
- Ait-gougam, 2008, Inverse modelling and pulsating torque minimization of salient pole sinusoidal synchronous machines, Electr. Power Syst. Res., 78, 88, 10.1016/j.epsr.2007.01.003 · doi:10.1016/j.epsr.2007.01.003
- Jan, 2008, Robust PID control design for permanent magnet synchronous motor: a genetic approach, Electr. Power Syst. Res., 78, 1161, 10.1016/j.epsr.2007.09.011 · doi:10.1016/j.epsr.2007.09.011
- le Roux, 2007, Detecting rotor faults in low power permanent magnet synchronous machines, IEEE Trans Power Electron, 22, 322, 10.1109/TPEL.2006.886620 · DOI · Paper page
- S. Rajagopalan, Detection of rotor and load faults in brushless dc motors operating under stationary and nonstationary conditions, PhD Thesis, Georgia Institute of Technology, August 2006. · DOI · Paper page
- le Roux, 2007, Detecting rotor faults in low power permanent magnet synchronous machines, IEEE Trans. Power Electron., 22, 322, 10.1109/TPEL.2006.886620 · DOI · Paper page
- Roy, 2008, Signal feature extraction from microbarograph observations using the Hilbert-Huang transform, IEEE Trans. Geosci. Remote Sens., 46, 1442, 10.1109/TGRS.2007.909916 · doi:10.1109/tgrs.2007.909916
- Antonino-Daviu, 2006, Application and optimization of the discrete wavelet transform for the detection of broken rotor bars in induction machines, Appl. Comput. Harmon. Anal., 21, 268, 10.1016/j.acha.2005.12.003 · doi:10.1016/j.acha.2005.12.003
- Huang, 1998, The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis, Proc. R. Soc. Lond. A, 454, 903, 10.1098/rspa.1998.0193 · DOI · Paper page
- Kerschen, 2008, Toward a fundamental understanding of the Hilbert-Huang transform in nonlinear structural dynamics, J. Vib. Control, 14, 77, 10.1177/1077546307079381 · DOI
- Veltcheva, 2007, Analysis of abnormal wave records by the Hilbert-Huang transform method, J. Atmos. Ocean Technol., 24, 1678, 10.1175/JTECH2067.1 · doi:10.1175/jtech2067.1
- Li, 2008, Analysis of depth of anesthesia with Hilbert-Huang spectral entropy, Clin. Neurophysiol., 119, 2465, 10.1016/j.clinph.2008.08.006 · DOI
- Yu, 2007, Application of time–frequency entropy method based on Hilbert-Huang transform to gear fault diagnosis, Measurement, 40, 823, 10.1016/j.measurement.2007.03.004 · DOI
- Andrade, 2004, Identification of instantaneous attributes of torsional shaft signals using the Hilbert transform, IEEE Trans. Power Syst., 19, 1422, 10.1109/TPWRS.2004.829664 · doi:10.1109/tpwrs.2004.829664
- Senroy, 2008, Generator coherency using the Hilbert-Huang transform, IEEE Trans. Power Syst., 23, 1701, 10.1109/TPWRS.2008.2004736 · doi:10.1109/tpwrs.2008.2004736
- Lu, 2005, Structural integrity monitoring of steam generator tubing using transient acoustic signal analysis, IEEE Trans. Nuclear Sci., 52, 484, 10.1109/TNS.2004.843121 · doi:10.1109/tns.2004.843121
- Yan, 2007, A tour of the tour of the Hilbert-Huang transform: an empirical tool for signal analysis, IEEE Instrum. Meas. Mag., 10, 40, 10.1109/MIM.2007.4343566 · DOI
- Yan, 2006, Hilbert-Huang transform-based vibration signal analysis for machine health monitoring, IEEE Trans. Instrum. Meas., 55, 2320, 10.1109/TIM.2006.887042 · DOI · Paper page
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In conference papers [109], [110] and following articles [111], [112] the HHT was applied to stator current signal obtained from FEM simulation model of the PMSM with DF under different speed and load torque values.”
MethodInfluentialRare-earth-free propulsion motors for electric vehicles: A technology review
Riba, J.-R., López-Torres, C., Romeral, L., & Garcia, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.121 · Cited by 265
Self-citationFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
“Main appealing features of PMSMs comprise high power to weight ratio, high torque to current ratio, simple construction, high efficiency, and precise torque control even at low speed [2], [3].”
BackgroundSelf-citationA Back-emf Based Method to Detect Magnet Failures in PMSMs
Urresty, J.-C., Riba, J.-R., & Romeral, L. (2013) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2207731 · Cited by 151
“This is because they offer highly attractive features, including high efficiency, precise torque control, high power density and high torque to current ratio among others [2], [3].”
BackgroundSelf-citation
Metadata
- Authors
- Ruiz, J.-R. R., Garcia Espinosa, A., Romeral, L., & Cusidó, J.
- Venue
- Electric Power Systems Research
- Publisher
- Elsevier BV
- Published
- 2010-10
- Volume
- 80
- Issue
- 10
- Pages
- 1277-1285
- ISSN
- 0378-7796 (ISSN-L)
- OpenAlex
- W2055489457
- Cited by
- 51
- References
- 2
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.