CoChat

Demagnetization diagnosis in permanent magnet synchronous motors under non-stationary speed conditions

Open access
Ruiz, Jordi-Roger Riba, Garcia Espinosa, Antonio, Romeral, Luís, Cusidó, Jordi · 2010 · Electric Power Systems Research
Cited by 51

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Permanent magnet synchronous motors (PMSMs) are applied in high performance positioning and variable speed applications because of their enhanced features with respect to other AC motor types. Fault detection and diagnosis of electrical motors for critical applications is an active field of research. However, much research remains to be done in the field of PMSM demagnetization faults, especially when running under non-stationary conditions. This paper presents a time–frequency method specifically focused to detect and diagnose demagnetization faults in PMSMs running under non-stationary speed conditions, based on the Hilbert Huang transform. The effectiveness of the proposed method is proven by means of experimental results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.epsr.2010.04.010

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 24

  1. Dai, 2005, Fault analysis of a PM brushless DC motor using finite element method, IEEE Trans. Energy Conv., 20, 1, 10.1109/TEC.2004.841516 · DOI · Paper page
  2. Razika, 2009, An induction machine model including interbar currents for studying, Electr. Power Syst. Res., 79, 181, 10.1016/j.epsr.2008.05.015 · doi:10.1016/j.epsr.2008.05.015
  3. Calıs, 2007, Rotor bar fault diagnosis in three phase induction motors by monitoring fluctuations of motor current zero crossing instants performances during transients and steady state, Electr. Power Syst. Res., 77, 385, 10.1016/j.epsr.2006.03.017 · doi:10.1016/j.epsr.2006.03.017
  4. Ye, 2006, Mechanical fault diagnostics for induction motor with variable speed drives using Adaptive Neuro-fuzzy Inference System, Electr. Power Syst. Res., 76, 742, 10.1016/j.epsr.2005.10.011 · doi:10.1016/j.epsr.2005.10.011
  5. Bacha, 2008, Induction machine fault detection using stray flux EMF measurement and neural network-based decision, Electr. Power Syst. Res., 78, 1247, 10.1016/j.epsr.2007.10.006 · doi:10.1016/j.epsr.2007.10.006
  6. Samsi, 2009, Early detection of stator voltage imbalance in three-phase induction motors, Electr. Power Syst. Res., 79, 239, 10.1016/j.epsr.2008.06.004 · doi:10.1016/j.epsr.2008.06.004
  7. Morel, 2008, A predictive current control applied to a permanent magnet synchronous machine, comparison with a classical direct torque control, Electr. Power Syst. Res., 78, 1437, 10.1016/j.epsr.2008.01.004 · doi:10.1016/j.epsr.2008.01.004
  8. Ait-gougam, 2008, Inverse modelling and pulsating torque minimization of salient pole sinusoidal synchronous machines, Electr. Power Syst. Res., 78, 88, 10.1016/j.epsr.2007.01.003 · doi:10.1016/j.epsr.2007.01.003
  9. Jan, 2008, Robust PID control design for permanent magnet synchronous motor: a genetic approach, Electr. Power Syst. Res., 78, 1161, 10.1016/j.epsr.2007.09.011 · doi:10.1016/j.epsr.2007.09.011
  10. le Roux, 2007, Detecting rotor faults in low power permanent magnet synchronous machines, IEEE Trans Power Electron, 22, 322, 10.1109/TPEL.2006.886620 · DOI · Paper page
  11. S. Rajagopalan, Detection of rotor and load faults in brushless dc motors operating under stationary and nonstationary conditions, PhD Thesis, Georgia Institute of Technology, August 2006. · DOI · Paper page
  12. le Roux, 2007, Detecting rotor faults in low power permanent magnet synchronous machines, IEEE Trans. Power Electron., 22, 322, 10.1109/TPEL.2006.886620 · DOI · Paper page
  13. Roy, 2008, Signal feature extraction from microbarograph observations using the Hilbert-Huang transform, IEEE Trans. Geosci. Remote Sens., 46, 1442, 10.1109/TGRS.2007.909916 · doi:10.1109/tgrs.2007.909916
  14. Antonino-Daviu, 2006, Application and optimization of the discrete wavelet transform for the detection of broken rotor bars in induction machines, Appl. Comput. Harmon. Anal., 21, 268, 10.1016/j.acha.2005.12.003 · doi:10.1016/j.acha.2005.12.003
  15. Huang, 1998, The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis, Proc. R. Soc. Lond. A, 454, 903, 10.1098/rspa.1998.0193 · DOI · Paper page
  16. Kerschen, 2008, Toward a fundamental understanding of the Hilbert-Huang transform in nonlinear structural dynamics, J. Vib. Control, 14, 77, 10.1177/1077546307079381 · DOI
  17. Veltcheva, 2007, Analysis of abnormal wave records by the Hilbert-Huang transform method, J. Atmos. Ocean Technol., 24, 1678, 10.1175/JTECH2067.1 · doi:10.1175/jtech2067.1
  18. Li, 2008, Analysis of depth of anesthesia with Hilbert-Huang spectral entropy, Clin. Neurophysiol., 119, 2465, 10.1016/j.clinph.2008.08.006 · DOI
  19. Yu, 2007, Application of time–frequency entropy method based on Hilbert-Huang transform to gear fault diagnosis, Measurement, 40, 823, 10.1016/j.measurement.2007.03.004 · DOI
  20. Andrade, 2004, Identification of instantaneous attributes of torsional shaft signals using the Hilbert transform, IEEE Trans. Power Syst., 19, 1422, 10.1109/TPWRS.2004.829664 · doi:10.1109/tpwrs.2004.829664
  21. Senroy, 2008, Generator coherency using the Hilbert-Huang transform, IEEE Trans. Power Syst., 23, 1701, 10.1109/TPWRS.2008.2004736 · doi:10.1109/tpwrs.2008.2004736
  22. Lu, 2005, Structural integrity monitoring of steam generator tubing using transient acoustic signal analysis, IEEE Trans. Nuclear Sci., 52, 484, 10.1109/TNS.2004.843121 · doi:10.1109/tns.2004.843121
  23. Yan, 2007, A tour of the tour of the Hilbert-Huang transform: an empirical tool for signal analysis, IEEE Instrum. Meas. Mag., 10, 40, 10.1109/MIM.2007.4343566 · DOI
  24. Yan, 2006, Hilbert-Huang transform-based vibration signal analysis for machine health monitoring, IEEE Trans. Instrum. Meas., 55, 2320, 10.1109/TIM.2006.887042 · DOI · Paper page

Cited by

Metadata

Authors
Ruiz, J.-R. R., Garcia Espinosa, A., Romeral, L., & Cusidó, J.
Venue
Electric Power Systems Research
Publisher
Elsevier BV
Published
2010-10
Volume
80
Issue
10
Pages
1277-1285
ISSN
0378-7796 (ISSN-L)
OpenAlex
W2055489457
Cited by
51
References
2
FWCI
6.90
Type
journal article
Language
en
Open access
green
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.