Comprehensive survey of computational ECG analysis: Databases, methods and applications
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
Electrocardiogram (ECG) recordings are indicative for the state of the human heart. Automatic analysis of these recordings can be performed using various computational methods from the areas of signal processing and machine learning. In addition to the 12-lead ECG devices and the Holter monitor, as currently the most widely used ECG screening methods in clinical practice, ECG recordings are recently often acquired with small novel wireless ECG body sensors. These novel types of body sensors allow for ECG monitoring and analysis to be used for a much broader array of applications than only diagnosing cardiovascular disorders. The new types of ECG measuring devices, as well as their broader and more frequent use, pose new challenges in the processing and analysis of ECG, and furthermore, raise the need for automatic, low-cost, real-time, and efficient ECG monitoring that can be used at home or under ambulatory settings alike. This paper provides a comprehensive survey on the variety of both ECG data and computational methods in various applications: morphological and rhythmic arrhythmia detection, signal quality assessment, biometric identification, respiration estimation, fetal ECG extraction, and physical and emotional monitoring. It includes an extensive overview of 45 diverse ECG public databases and their analysis with state-of-the-art computational ECG methods. We highlight the most notable achievements in each of these ECG application areas in the recent years, and, furthermore, identify future trends in computational ECG analysis, especially analysis of ECG from mobile devices. The general conclusion is that ECG for medical diagnosis is successfully analyzed with the existing methods, while different applications during daily ECG monitoring are still open fields. Given how deep learning has been able to successfully address a lot of the most significant computational ECG problems, like arrhythmia classification, in future, it is expected for deep learning methods to be comprehensively tested in areas where they have not been yet applied, such as respiration estimation and fetal ECG extraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
A deep convolutional neural network model to classify heartbeats
Acharya, U. R., Oh, S. L., Hagiwara, Y., Tan, J. H., Adam, M., Gertych, A., & Tan, R. S. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.022 · Cited by 1,421
PTB-XL, a large publicly available electrocardiography dataset
Wagner, P., Strodthoff, N., Bousseljot, R.-D., Kreiseler, D., Lunze, F. I., Samek, W., & Schaeffter, T. (2020) · Scientific Data · doi:10.1038/s41597-020-0495-6 · Cited by 1,315
Ganong's Review of Medical Physiology
Barrett, K. E. (2009) · Repository of the University of Ljubljana (University of Ljubljana) · Cited by 1,153
Quantitative Investigation of QRS Detection Rules Using the MIT/BIH Arrhythmia Database
Hamilton, P. S., & Tompkins, W. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325695 · Cited by 1,142
Deep learning for healthcare applications based on physiological signals: A review
Faust, O., Hagiwara, Y., Hong, T. J., Lih, O. S., & Acharya, U. R. (2018) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2018.04.005 · Cited by 1,026
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894
ECG-based heartbeat classification for arrhythmia detection: A survey
Luz, E. J. D. S., Schwartz, W. R., Cámara-Chávez, G., & Menotti, D. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.12.008 · Cited by 878
Ribeiro, A. H., Ribeiro, M. H., Paixao, G. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · RePEc: Research Papers in Economics · doi:10.5281/zenodo.3625006 · Cited by 715
Age-related alterations in the fractal scaling of cardiac interbeat interval dynamics
Iyengar, N., Peng, C. K., Morin, R., Goldberger, A. L., & Lipsitz, L. A. (1996) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1996.271.4.r1078 · Cited by 702
Liu, F., Liu, C., Zhao, L., Zhang, X., Wu, X., Xu, X., Liu, Y., Ma, C., Wei, S., He, Z., et al. (2018) · Journal of Medical Imaging and Health Informatics · doi:10.1166/jmihi.2018.2442 · Cited by 620
A Nonlinear Bayesian Filtering Framework for ECG Denoising
Sameni, R., Shamsollahi, M. B., Jutten, C., & Clifford, G. D. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897817 · Cited by 502
Deep Learning for ECG Analysis: Benchmarks and Insights from PTB-XL
Strodthoff, N., Wagner, P., Schaeffter, T., & Samek, W. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3022989 · Cited by 491
A 12-lead electrocardiogram database for arrhythmia research covering more than 10,000 patients
Zheng, J., Zhang, J., Danioko, S., Yao, H., Guo, H., & Rakovski, C. (2020) · Scientific Data · doi:10.1038/s41597-020-0386-x · Cited by 487
Yao, Q., Wang, R., Fan, X., Liu, J., & Li, Y. (2020) · Information Fusion · doi:10.1016/j.inffus.2019.06.024 · Cited by 469
Analysis of First-Derivative Based QRS Detection Algorithms
Arzeno, N. M., Deng, Z.-D., & Poon, C.-S. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.912658 · Cited by 413
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Deep-ECG: Convolutional Neural Networks for ECG biometric recognition
Donida Labati, R., Muñoz, E., Piuri, V., Sassi, R., & Scotti, F. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2018.03.028 · Cited by 349
Wearable sensors for monitoring the internal and external workload of the athlete
Seshadri, D. R., Li, R. T., Voos, J. E., Rowbottom, J. R., Alfes, C. M., Zorman, C. A., & Drummond, C. K. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0149-2 · Cited by 330
Survival of patients with severe congestive heart failure treated with oral milrinone
Baim, D. S., Colucci, W. S., Monrad, E. S., Smith, H. S., Wright, R. F., Lanoue, A., Gauthier, D. F., Ransil, B. J., Grossman, W., & Braunwald, E. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80478-8 · Cited by 303
Testing and reporting performance results of cardiac rhythm and ST segment measurement algorithms
(2013) · ANSI/AAMI EC57:2012/(R)2020; Testing and reporting performance results of cardiac rhythm and ST segment measurement algorithms · doi:10.2345/9781570204784.ch1 · Cited by 276
Fast QRS Detection with an Optimized Knowledge-Based Method: Evaluation on 11 Standard ECG Databases
Elgendi, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073557 · Cited by 264
Diagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
Sayadi, O., & Shamsollahi, M. B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921150 · Cited by 254
Nonlocal Means Denoising of ECG Signals
Tracey, B. H., & Miller, E. L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208964 · Cited by 248
Secondary Analysis of Electronic Health Records
Data, M. C. (2016) · OAPEN (The OAPEN Foundation) · doi:10.1007/978-3-319-43742-2 · Cited by 246
A dataset of continuous affect annotations and physiological signals for emotion analysis
Sharma, K., Castellini, C., van den Broek, E. L., Albu-Schaeffer, A., & Schwenker, F. (2019) · Scientific Data · doi:10.1038/s41597-019-0209-0 · Cited by 242
2021 Computing in Cardiology (CinC)
(2021) · doi:10.23919/cinc53138.2021 · Cited by 236
A robust deep convolutional neural network with batch-weighted loss for heartbeat classification
Sellami, A., & Hwang, H. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.12.037 · Cited by 229
Lyon, A., Mincholé, A., Martínez, J. P., Laguna, P., & Rodriguez, B. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0821 · Cited by 228
Elgendi, M., Eskofier, B., Dokos, S., & Abbott, D. (2014) · PLoS ONE · doi:10.1371/journal.pone.0084018 · Cited by 222
Petrutiu, S., Sahakian, A. V., & Swiryn, S. (2007) · EP Europace · doi:10.1093/europace/eum096 · Cited by 221
Genetic algorithm for the optimization of features and neural networks in ECG signals classification
Li, H., Yuan, D., Ma, X., Cui, D., & Cao, L. (2017) · Scientific Reports · doi:10.1038/srep41011 · Cited by 196
Chen, T.-M., Huang, C.-H., Shih, E. S. C., Hu, Y.-F., & Hwang, M.-J. (2020) · iScience · doi:10.1016/j.isci.2020.100886 · Cited by 191
Automatic QRS complex detection using two-level convolutional neural network
Xiang, Y., Lin, Z., & Meng, J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0441-4 · Cited by 169
LUDB: A New Open-Access Validation Tool for Electrocardiogram Delineation Algorithms
Kalyakulina, A., Yusipov, I., Moskalenko, V. A., Nikolskiy, A. V., Алексеевич, К. К., Osipov, G. V., Zolotykh, N. Y., & Ivanchenko, M. (2020) · IEEE Access · doi:10.1109/access.2020.3029211 · Cited by 164
A Comparative Study of ECG-derived Respiration in Ambulatory Monitoring using the Single-lead ECG
Varon, C., Morales, J., Lázaro, J. M., Orini, M., Deviaene, M., Kontaxis, S., Testelmans, D., Buyse, B., Borzée, P., Sörnmo, L., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-62624-5 · Cited by 159
Yıldırım, Ö., Talo, M., Ciaccio, E. J., Tan, R., & Acharya, U. R. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105740 · Cited by 158
Toward improving ECG biometric identification using cascaded convolutional neural networks
Li, Y., Pang, Y., Wang, K., & Li, X. (2020) · Neurocomputing · doi:10.1016/j.neucom.2020.01.019 · Cited by 126
Personalized Monitoring and Advance Warning System for Cardiac Arrhythmias
Kiranyaz, S., Ince, T., & Gabbouj, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-09544-z · Cited by 125
The development and analysis of a ventricular fibrillation detector
Greenwald, S. D. (1986) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 112
Qin, Q., Li, J., Zhang, L., Yue, Y., & Liu, C. (2017) · Scientific Reports · doi:10.1038/s41598-017-06596-z · Cited by 111
Clinically accurate fetal ECG parameters acquired from maternal abdominal sensors
Clifford, G. D., Sameni, R., Ward, J., Robinson, J. N., & Wolfberg, A. (2011) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2011.02.066 · Cited by 109
Robust fetal ECG extraction and detection from abdominal leads
Andreotti, F., Riedl, M., Himmelsbach, T., Wedekind, D., Wessel, N., Stepan, H., Schmieder, C., Jank, A., Malberg, H., & Zaunseder, S. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/8/1551 · Cited by 109
Separation and Analysis of Fetal-ECG Signals From Compressed Sensed Abdominal ECG Recordings
Poian, G. D., Bernardini, R., & Rinaldo, R. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2493726 · Cited by 109
Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations
Matonia, A., Jeżewski, J., Kupka, T., Jeżewski, M., Horoba, K., Wróbel, J., Czabański, R., & Kahankova, R. V. (2020) · Scientific Data · doi:10.1038/s41597-020-0538-z · Cited by 109
Smith, S. W., Walsh, B., Grauer, K., Wang, K., Rapin, J., Li, J., Fennell, W., & Taboulet, P. (2019) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.11.013 · Cited by 106
Satija, U., Ramkumar, B., & Manikandan, M. S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877055 · Cited by 102
CorrNet: Fine-Grained Emotion Recognition for Video Watching Using Wearable Physiological Sensors
Zhang, T., Ali, A. E., Wang, C., Hanjalić, A., & Cesar, P. S. (2020) · Sensors · doi:10.3390/s21010052 · Cited by 89
An, X., & Stylios, G. K. (2020) · Sensors · doi:10.3390/s20051468 · Cited by 86
Predicting Bradycardia in Preterm Infants Using Point Process Analysis of Heart Rate
Gee, A. H., Barbieri, R., Paydarfar, D., & Indic, P. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2632746 · Cited by 85
Semi-supervised learning for ECG classification without patient-specific labeled data
Zhai, X., Zhou, Z., & Tin, C. (2020) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.113411 · Cited by 83
QRS Detection and Heart Rate Variability Analysis: A Survey
Oweis, R. J., & Al-Tabbaa, B. O. (2014) · Biomedical Science and Engineering · doi:10.12691/bse-2-1-3 · Cited by 80
Intelligent hybrid approaches for human ECG signals identification
Bassiouni, M. M., El‐Dahshan, E. A., Khalefa, W., & Salem, A.-B. M. (2018) · Signal Image and Video Processing · doi:10.1007/s11760-018-1237-5 · Cited by 74
Automatic Atrial Fibrillation Detection Based on Heart Rate Variability and Spectral Features
Mei, Z., Gu, X., Chen, H., & Chen, W. (2018) · IEEE Access · doi:10.1109/access.2018.2871220 · Cited by 67
Medical-Grade ECG Sensor for Long-Term Monitoring
Rashkovska, A., Depolli, M., Tomašić, I., Avbelj, V., & Trobec, R. (2020) · Sensors · doi:10.3390/s20061695 · Cited by 65
Self-citationAtrial fibrillation detection using heart rate variability and atrial activity: A hybrid approach
Hirsch, G., Jensen, S. H., Poulsen, E. S., & Puthusserypady, S. K. (2020) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.114452 · Cited by 65
Iqbal, T., Elahi, A., Redón, P., Vazquez, P., Wijns, W. C., & Shahzad, A. (2021) · Diagnostics · doi:10.3390/diagnostics11030556 · Cited by 63
Wearable Electronics Sensors: For Safe and Healthy Living
Mukhopadhyay, S. C. (2015) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-18191-2 · Cited by 60
Modification of ACC/ESC criteria for acute myocardial infarction
Macfarlane, P. W., Browne, D., Devine, B., Clark, E., Miller, E., Seyal, J., & Hampton, D. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.032 · Cited by 58
Marsili, I. A., Biasiolli, L., Masè, M., Adami, A., Andrighetti, A. O., Ravelli, F., & Nollo, G. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103540 · Cited by 57
Efficacy of diagnostic tools for detecting cardiac arrhythmias: systematic literature search
Hoefman, E., Bindels, P., & van Weert, H. C. P. M. (2010) · Netherlands Heart Journal · doi:10.1007/s12471-010-0831-0 · Cited by 56
A Personalized Arrhythmia Monitoring Platform
Raj, S., & Ray, K. C. (2018) · Scientific Reports · doi:10.1038/s41598-018-29690-2 · Cited by 45
Fotiadou, E., Konopczyński, T., Hesser, J., & Vullings, R. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab69b9 · Cited by 44
Smith, S. W., Rapin, J., Li, J., Fleureau, Y., Fennell, W. H., Walsh, B. M., Rosier, A., Fiorina, L., & Gardella, C. (2019) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100423 · Cited by 40
Altini, M., Polito, S., Penders, J., Kim, H., Van Helleputte, N., Kim, S., & Yazicioglu, F. (2011) · Proceedings of the 2nd Conference on Wireless Health · doi:10.1145/2077546.2077564 · Cited by 36
Body Sensors and Electrocardiography
Trobec, R., Tomašić, I., Rashkovska, A., Depolli, M., & Avbelj, V. (2017) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-59340-1 · Cited by 35
Self-citationHuang, H., Hu, S., & Sun, Y. (2019) · Sensors · doi:10.3390/s19071617 · Cited by 32
A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems
Sohn, K., Merchant, F. M., Sayadi, O., Puppala, D., Doddamani, R., Sahani, A. K., Singh, J. P., Heist, E. K., Isselbacher, E. M., & Armoundas, A. A. (2017) · Scientific Reports · doi:10.1038/srep44946 · Cited by 31
Pirhonen, M., & Vehkaoja, A. T. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101887 · Cited by 17
PCARD Platform for mHealth Monitoring
Depolli, M. (2016) · Informatica · Cited by 16
Proceedings of the 2nd Conference on Wireless Health
Jacobs, I. M., Soon‐Shiong, P., Topol, E. J., & Toumazou, C. (2011) · doi:10.1145/2077546 · Cited by 14
Certainty in QRS detection with artificial neural networks
Chromik, J., Pirl, L., Beilharz, J., Bert Arnrich, A., & Polze, A. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102628 · Cited by 13
Demidova, M. M., Carlson, J., Erlinge, D., & Platonov, P. G. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.11.011 · Cited by 11
Quality of One-channel Telemetric ECG Sensor Signal in Maximum Exercise Stress Tests
Siraiy, B., Trobec, R., & Ilić, V. (2019) · Measurement Science Review · doi:10.2478/msr-2019-0013 · Cited by 10
Cited by
Akkaş, T., Reshadsedghi, M., Şen, M., Kılıç, V., & Horzum, N. (2025) · Advanced Materials · doi:10.1002/adma.202504796 · Cited by 174
Metadata
- Authors
- Merdjanovska, E., & Rashkovska, A.
- Venue
- Expert Systems with Applications
- Publisher
- Elsevier BV
- Published
- 2022-10
- Volume
- 203
- Pages
- 117206
- ISSN
- 0957-4174 (ISSN-L)
- OpenAlex
- W4224993403
- Cited by
- 158
- References
- 89
- FWCI
- 21.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.