BACKGROUND/AIM Three-dimensional kinematic measures of gait are routinely used in clinical gait analysis and provide a key outcome measure for gait research and clinical practice. This systematic review identifies and evaluates current evidence for the inter-session and inter-assessor reliability of three-dimensional kinematic gait analysis (3DGA) data. METHOD A targeted search strategy identified reports that fulfilled the search criteria. The quality of full-text reports were tabulated and evaluated for quality using a customised critical appraisal tool. RESULTS Fifteen full manuscripts and eight abstracts were included. Studies addressed both within-assessor and between-assessor reliability, with most examining healthy adults. Four full-text reports evaluated reliability in people with gait pathologies. The highest reliability indices occurred in the hip and knee in the sagittal plane, with lowest errors in pelvic rotation and obliquity and hip abduction. Lowest reliability and highest error frequently occurred in the hip and knee transverse plane. Methodological quality varied, with key limitations in sample descriptions and strategies for statistical analysis. Reported reliability indices and error magnitudes varied across gait variables and studies. Most studies providing estimates of data error reported values (S.D. or S.E.) of less than 5 degrees , with the exception of hip and knee rotation. CONCLUSION This review provides evidence that clinically acceptable errors are possible in gait analysis. Variability between studies, however, suggests that they are not always achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Quality criteria were proposed for measurement properties of health status questionnaires
Terwee, C. B., Bot, S. D. M., de Boer, M. R., van der Windt, D. A. W. M., Knol, D. L., Dekker, J., Bouter, L. M., & de Vet, H. C. W. (2007) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2006.03.012 · Cited by 10,764
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Palisano, R., Rosenbaum, P., Walter, S., Russell, D., Wood, E., & Galuppi, B. (1997) · Developmental Medicine & Child Neurology · doi:10.1111/j.1469-8749.1997.tb07414.x · Cited by 6,721
Charbonneau, D. H. (2005) · Europe PMC (PubMed Central) · Cited by 2,041
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476
Foundations of Clinical Research
Portney, L. G., & Watkins, M. P. (1993) · Cited by 979
Conducting systematic reviews of diagnostic studies: didactic guidelines
Devillé, W. L., Buntinx, F., Bouter, L. M., Montori, V. M., de Vet, H. C., van der Windt, D. A., & Bezemer, P. D. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-9 · Cited by 960
Interpreting Change Scores of Tests and Measures Used in Physical Therapy
Haley, S. M., & Fragala-Pinkham, M. A. (2006) · Physical Therapy · doi:10.1093/ptj/86.5.735 · Cited by 937
Cited by
Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
Pfister, A., West, A. M., Bronner, S., & Noah, J. A. (2014) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2014.909540 · Cited by 552
Pataky, T. C., Vanrenterghem, J., & Robinson, M. A. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.02.051 · Cited by 385
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review
Peters, A., Galna, B., Sangeux, M., Morris, M., & Baker, R. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.09.004 · Cited by 367
Self-citationReliability and minimal detectible change values for gait kinematics and kinetics in healthy adults
Wilken, J. M., Rodriguez, K. M., Brawner, M., & Darter, B. J. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.09.105 · Cited by 337
Two-dimensional video-based analysis of human gait using pose estimation
Stenum, J., Rossi, C., & Roemmich, R. T. (2021) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1008935 · Cited by 321
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318
Changing Sidestep Cutting Technique Reduces Knee Valgus Loading
Dempsey, A. R., Lloyd, D. G., Elliott, B. C., Steele, J. R., & Munro, B. J. (2009) · The American Journal of Sports Medicine · doi:10.1177/0363546509334373 · Cited by 270
Fernández-González, P., Koutsou, A., Cuesta-Gómez, A., Carratalá-Tejada, M., Miangolarra-Page, J. C., & Molina-Rueda, F. (2020) · Sensors · doi:10.3390/s20113154 · Cited by 185
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123
Bauer, C. M., Rast, F. M., Ernst, M. J., Kool, J., Oetiker, S., Rissanen, S. M., Suni, J. H., & Kankaanpää, M. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2015.06.001 · Cited by 97
“Optoelectronic measurement systems are accepted as gold-standards for non-invasive analysis of trunk movement within research settings (Cuesta-Vargas et al., 2010, McGinley et al., 2009).”
MethodWerling, K., Bianco, N. A., Raitor, M., Stingel, J., Hicks, J. L., Collins, S. H., Delp, S. L., & Liu, C. K. (2023) · PLOS ONE · doi:10.1371/journal.pone.0295152 · Cited by 65
Lebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65
“for acceptability of kinematics measurement [43].”
Reliability and precision of 3D wireless measurement of scapular kinematics
van den Noort, J. C., Wiertsema, S. H., Hekman, K. M. C., Schönhuth, C. P., Dekker, J., & Harlaar, J. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1186-2 · Cited by 60
Yeo, S. S., & Park, G. Y. (2020) · Sensors · doi:10.3390/s20051343 · Cited by 56
“sampling rate of the Qualisys system used in the present study was 100 Hz [20,25].”
MethodBuganè, F., Benedetti, M., D’Angeli, V., & Leardini, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-146 · Cited by 54
“Nonetheless, pelvic kinematics is still the most reliable measure in clinical standard gait analysis with the lowest errors in pelvic rotation and obliquity [18].”
BackgroundNikolajsen, H., Larsen, P. K., Simonsen, E. B., Alkjær, T., Falkerslev, S., Kristensen, J. H., Jensen, B. R., Remvig, L., & Juul-Kristensen, B. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-341 · Cited by 28
Kinematics and kinetics of people who are hypermobile. A systematic review
Bates, A. V., & Alexander, C. M. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.01.009 · Cited by 26
“[31] recognised that assessor characteristics were rarely mentioned in the studies of reliability of 3D movement analysis.”
BackgroundBauer, C. M., Kankaanpää, M. J., Meichtry, A., Rissanen, S. M., & Suni, J. H. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.06.008 · Cited by 24
Evaluation of atraumatic hip instability measured by triaxial accelerometry during walking
Neira, A., Amenabar, T., Cristi-Sánchez, I., Rafols, C., Monckeberg, J. E., Belemmi, M., Neira, M., Soldan, M., & Silvestre, R. (2019) · Journal of Hip Preservation Surgery · doi:10.1093/jhps/hnz018 · Cited by 4
Metadata
- Authors
- McGinley, J. L., Baker, R., Wolfe, R., & Morris, M. E.
- Venue
- Gait & Posture
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 29
- Issue
- 3
- Pages
- 360-369
- ISSN
- 0966-6362 (ISSN-L)
- OpenAlex
- W2108499234
- Cited by
- 1,144
- References
- 53
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.