The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Cochlear implants: A remarkable past and a brilliant future
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Derivation of auditory filter shapes from notched-noise data
Glasberg, B. R., & Moore, B. C. J. (1990) · Hearing Research · doi:10.1016/0378-5955(90)90170-t · Cited by 2,423
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Self-citationFriesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1381538 · Cited by 1,049
Cross-modal plasticity: where and how?
Bavelier, D., & Neville, H. J. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn848 · Cited by 1,040
Rf, G. (1985) · Cited by 949
Chimaeric sounds reveal dichotomies in auditory perception
Smith, Z. M., Delgutte, B., & Oxenham, A. J. (2002) · Nature · doi:10.1038/416087a · Cited by 873
Electrical Stimulation of the Auditory Nerve in Man
SIMMONS, F. B. (1966) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1966.00760030004003 · Cited by 613
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Cross-modal plasticity and cochlear implants
Lee, D. S., Lee, J. S., Oh, S. H., Kim, S.-K., Kim, J.-W., Chung, J.-K., Lee, M. C., & Kim, C. S. (2001) · Nature · doi:10.1038/35051653 · Cited by 480
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Self-citationSpeech recognition with amplitude and frequency modulations
Zeng, F.-G., Nie, K., Stickney, G. S., Kong, Y.-Y., Vongphoe, M., Bhargave, A., Wei, C., & Cao, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406460102 · Cited by 383
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Kral, A., & Eggermont, J. J. (2007) · Brain Research Reviews · doi:10.1016/j.brainresrev.2007.07.021 · Cited by 338
Temporal pitch in electric hearing
Zeng, F.-G. (2002) · Hearing Research · doi:10.1016/s0378-5955(02)00644-5 · Cited by 314
Pitch perception by cochlear implant subjects
Townshend, B., Cotter, N., Van Compernolle, D., & White, R. L. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395554 · Cited by 306
Histopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., et al. (2001) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Hearing preservation in cochlear implantation for electric acoustic stimulation
Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480410016432 · Cited by 277
Skinner, M. W., Clark, G. M., Whitford, L. A., Seligman, P., Staller, S. J., Shipp, D. B., Shallop, J. K., Everingham, C., Menapace, C., & Arndt, P. L. (1994) · PubMed · Cited by 276
Dorman, M. F., Gifford, R. H., Spahr, A. J., & McKarns, S. A. (2008) · Audiology and Neurotology · doi:10.1159/000111782 · Cited by 275
Self-citationRapid development of cortical auditory evoked potentials after early cochlear implantation
Sharma, A., Dorman, M. F., & Spahr, A. J. (2002) · Neuroreport · doi:10.1097/00001756-200207190-00030 · Cited by 260
Self-citationMED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
Multichannel auditory brainstem implant: update on performance in 61 patients
Otto, S. R., Brackmann, D. E., Hitselberger, W. E., Shannon, R. V., & Kuchta, J. (2002) · Journal of neurosurgery · doi:10.3171/jns.2002.96.6.1063 · Cited by 253
Eggermont, J. J., & Ponton, C. W. (2003) · Acta Oto-Laryngologica · doi:10.1080/0036554021000028098 · Cited by 246
Correct tonotopic representation is necessary for complex pitch perception
Oxenham, A. J., Bernstein, J. G. W., & Penagos, H. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0306958101 · Cited by 238
Ponton, C. W., & Eggermont, J. J. (2001) · Audiology and Neurotology · doi:10.1159/000046846 · Cited by 231
Multichannel Cochlear Implants: Relation of Histopathology to Performance
Fayad, J. N., & Linthicum, F. H. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227176.09500.28 · Cited by 222
Cochlear Implants in Adults and Children
Gates, G. A. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530240065043 · Cited by 211
Encoding Frequency Modulation to Improve Cochlear Implant Performance in Noise
Nie, K., Stickney, G., & Zeng, F.-G. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839799 · Cited by 209
Current focusing and steering: Modeling, physiology, and psychophysics
Bonham, B. H., & Litvak, L. M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.03.006 · Cited by 197
Deafness-Induced Changes in the Auditory Pathway: Implications for Cochlear Implants
Shepherd, R. K., & Hardie, N. A. (2001) · Audiology and Neurotology · doi:10.1159/000046843 · Cited by 189
Berenstein, C. K., Mens, L. H. M., Mulder, J. J. S., & Vanpoucke, F. J. (2008) · Ear & Hearing · doi:10.1097/aud.0b013e3181645336 · Cited by 178
Cochlear implants: cortical plasticity in congenital deprivation
Kral, A., Tillein, J., Heid, S., Klinke, R., & Hartmann, R. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)57018-9 · Cited by 171
Gantz, B. J., Turner, C., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
Maximizing cochlear implant patients’ performance with advanced speech training procedures
Fu, Q.-J., & Galvin, J. J. (2008) · Hearing Research · doi:10.1016/j.heares.2007.11.010 · Cited by 162
Cochlear Implants: Some Likely Next Steps
Wilson, B. S., Lawson, D. T., Müller, J. M., Tyler, R. S., & Kiefer, J. (2003) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.5.040202.121645 · Cited by 160
Self-citationAuditory Prosthesis with a Penetrating Nerve Array
Middlebrooks, J. C., & Snyder, R. L. (2007) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-007-0070-2 · Cited by 158
Incremental training increases the plasticity of the auditory space map in adult barn owls
Linkenhoker, B. A., & Knudsen, E. I. (2002) · Nature · doi:10.1038/nature01002 · Cited by 153
Burns, E. M., & Viemeister, N. F. (1976) · The Journal of the Acoustical Society of America · doi:10.1121/1.381166 · Cited by 153
Cochlear implants and brain plasticity
Fallon, J. B., Irvine, D. R. F., & Shepherd, R. K. (2007) · Hearing Research · doi:10.1016/j.heares.2007.08.004 · Cited by 152
HISTOPATHOLOGY OF PROFOUND SENSORINEURAL DEAFNESSa
Hinojosa, R., & Marion, M. S. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31662.x · Cited by 148
Research Plan for Evaluating Subjects Presently Fitted with Implanted Auditory Prostheses
Bilger, R. C., Black, F. O., & Hopkinson, N. T. (1977) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894770860s303 · Cited by 142
Place-pitch discrimination of single- versus dual-electrode stimuli by cochlear implant users
Donaldson, G. S., Kreft, H. A., & Litvak, L. M. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1937362 · Cited by 140
Temporal representations with cochlear implants.
Wilson, B. S., Finley, C. C., Lawson, D. T., & Zerbi, M. (1997) · PubMed · Cited by 130
Self-citationCochlear implants and ex vivo BDNF gene therapy protect spiral ganglion neurons
Rejali, D., Lee, V. A., Abrashkin, K. A., Humayun, N., Swiderski, D. L., & Raphael, Y. (2007) · Hearing Research · doi:10.1016/j.heares.2007.02.010 · Cited by 129
Speech and music perception with the new fine structure speech coding strategy: preliminary results
Arnoldner, C., Riss, D., Brunner, M., Ďurišin, M., Baumgartner, W., & Hamzavi, J. (2007) · Acta Oto-Laryngologica · doi:10.1080/00016480701275261 · Cited by 125
Optical stimulation of auditory neurons: Effects of acute and chronic deafening
Richter, C., Bayon, R., Izzo, A. D., Otting, M., Suh, E., Goyal, S., Hotaling, J. M., & Walsh, J. T. (2008) · Hearing Research · doi:10.1016/j.heares.2008.01.011 · Cited by 125
Improved Music Perception with Explicit Pitch Coding in Cochlear Implants
Laneau, J., Wouters, J. M., & Moonen, M. (2005) · Audiology and Neurotology · doi:10.1159/000088853 · Cited by 124
Mandarin tone recognition in cochlear-implant subjects
Wei, C., Cao, K., & Zeng, F. (2004) · Hearing Research · doi:10.1016/j.heares.2004.06.002 · Cited by 118
Strategies to preserve or regenerate spiral ganglion neurons
Roehm, P. C., & Hansen, M. R. (2005) · Current Opinion in Otolaryngology & Head & Neck Surgery · doi:10.1097/01.moo.0000180919.68812.b9 · Cited by 118
Cochlear Implants and Brain Plasticity
Fallon, J. B., Irvine, D. R. F., & Shepherd, R. K. (2002) · KARGER eBooks · doi:10.1159/isbn.978-3-318-00824-1 · Cited by 118
Performance of Patients Using Different Cochlear Implant Systems: Effects of Input Dynamic Range
Spahr, A. J., Dorman, M. F., & Loiselle, L. H. (2007) · Ear and Hearing · doi:10.1097/aud.0b013e3180312607 · Cited by 113
Self-citationA Psychoacoustic "NofM"-Type Speech Coding Strategy for Cochlear Implants
Nogueira, W., Büchner, A., Lenarz, T., & Edler, B. (2005) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/asp.2005.3044 · Cited by 111
Pitch ranking with nonsimultaneous dual-electrode electrical stimulation of the cochlea
McDermott, H. J., & McKay, C. M. (1994) · The Journal of the Acoustical Society of America · doi:10.1121/1.410475 · Cited by 107
Thirty years of theBritish Journal of Audiology: Guest editorial: The future of cochlear implants
Wilson, B. S. (1997) · British Journal of Audiology · doi:10.3109/03005369709076795 · Cited by 106
Self-citationCochlear nucleus auditory prostheses
McCreery, D. B. (2008) · Hearing Research · doi:10.1016/j.heares.2007.11.014 · Cited by 93
Koch, D. B., Osberger, M. J., Segel, P., & Kessler, D. K. (2004) · Audiology and Neurotology · doi:10.1159/000078391 · Cited by 93
Direct Stimulation of Auditory Nerve Fibers
LAWRENCE, M. (1964) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1964.00750040379002 · Cited by 93
Green, T., Faulkner, A., Rosen, S., & Macherey, O. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1925827 · Cited by 92
Pettingill, L. N., Richardson, R. T., Wise, A. K., O’Leary, S. J., & Shepherd, R. K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895375 · Cited by 87
Combined Electroacoustic Stimulation in Conventional Candidates for Cochlear Implantation
James, C. J., Fraysse, B., Déguine, O., Lenarz, T., Mawman, D. J., Ramos, Á., Ramsden, R. T., & Sterkers, O. (2006) · Audiology and Neurotology · doi:10.1159/000095615 · Cited by 86
Two New Directions in Speech Processor Design for Cochlear Implants
Wilson, B. S., Schatzer, R., Lopez‐Poveda, E. A., Sun, X., Lawson, D. T., & Wolford, R. D. (2005) · Ear and Hearing · doi:10.1097/00003446-200508001-00009 · Cited by 79
Self-citationComparative studies of speech processing strategies for cochlear implants
Wilson, B. S., Finley, C. C., Weber, B. A., White, M. W., Farmer, J. C., Wolford, R. D., Merzenich, M. M., Lawson, D. T., Kenan, P. D., & Schindler, R. A. (1988) · The Laryngoscope · doi:10.1288/00005537-198810000-00009 · Cited by 74
Self-citationLocalized cell and drug delivery for auditory prostheses
Hendricks, J. L., Chikar, J. A., Crumling, M. A., Raphael, Y., & Martin, D. C. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.003 · Cited by 74
Zwolan, T. A., Kileny, P. R., Ashbaugh, C., & Telian, S. A. (1996) · PubMed · Cited by 73
The perception of temporal modulations by cochlear implant patients
Busby, P. A., Tong, Y. C., & Clark, G. M. (1993) · The Journal of the Acoustical Society of America · doi:10.1121/1.408212 · Cited by 72
Pfingst, B. E., Franck, K. H., Xu, L., Bauer, E., & Zwolan, T. A. (2001) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620010065 · Cited by 72
The Surprising Performance of Present-Day Cochlear Implants
Wilson, B. S., & Dorman, M. F. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893505 · Cited by 72
Self-citationLim, H. H., Lenarz, T., Joseph, G., Battmer, R., Samii, A., Samii, M., Patrick, J. F., & Lenarz, M. (2007) · Journal of Neuroscience · doi:10.1523/jneurosci.3123-07.2007 · Cited by 71
Pfingst, B. E., & Xu, L. (2004) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-003-3051-0 · Cited by 70
Kiefer, J., Ilberg, C. V., Hubner-Egner, J., Rupprecht, V., & Knecht, R. (2000) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940010901105 · Cited by 69
Are spiral ganglion cell numbers important for speech perception with a cochlear implant?
Blamey, P. J. (1997) · PubMed · Cited by 67
PERCEPTS FROM THE VIENNA COCHLEAR PROSTHESISa
Hochmair-Desoyer, I. J., Hochmair, E. S., Burian, K., & Stiglbrunner, H. K. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31642.x · Cited by 64
Alternative pulse shapes in electrical hearing
Wieringen, A. V., Macherey, O., Carlyon, R. P., Deeks, J. M., & Wouters, J. M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.03.005 · Cited by 63
Intraneural stimulation for auditory prosthesis: Modiolar trunk and intracranial stimulation sites
Middlebrooks, J. C., & Snyder, R. L. (2008) · Hearing Research · doi:10.1016/j.heares.2008.04.001 · Cited by 55
Cochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array
Hillman, T. A., Badi, A. N., Normann, R. A., Kertesz, T., & Shelton, C. (2003) · Otology & Neurotology · doi:10.1097/00129492-200309000-00013 · Cited by 54
The auditory midbrain implant: Effects of electrode location
Lim, H. H., Lenarz, T., Anderson, D. J., & Lenarz, M. (2008) · Hearing Research · doi:10.1016/j.heares.2008.02.003 · Cited by 52
High-density cochlear implants with position sensing and control
Wise, K. D., Bhatti, P. T., Wang, J., & Friedrich, C. R. (2008) · Hearing Research · doi:10.1016/j.heares.2008.04.002 · Cited by 50
On Hearing by Electrical Stimulation
Stevens, S. S. (1937) · The Journal of the Acoustical Society of America · doi:10.1121/1.1902000 · Cited by 45
Current Steering and Results From Novel Speech Coding Strategies
Buechner, A., Brendel, M., Krüeger, B., Frohne-Büchner, C., Nogueira, W., Edler, B., & Lenarz, T. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318163746 · Cited by 44
Wilson, B. S., & Dorman, M. F. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2007.912917 · Cited by 44
Self-citationThe Design and Function of Cochlear Implants
Dorman, M. F., & Wilson, B. S. (2004) · American Scientist · doi:10.1511/2004.49.942 · Cited by 44
Self-citationOn Hearing by Electrical Stimulation
Stevens, S. S. (1937) · The Journal of the Acoustical Society of America · doi:10.1121/1.1915894 · Cited by 41
Channel interactions in patients using the Ineraid multichannel cochlear implant
Favre, E., & Pelizzone, M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90136-o · Cited by 39
Development of a Novel Eighth‐Nerve Intraneural Auditory Neuroprosthesis
Badi, A. N., Kertesz, T. R., Gurgel, R. K., Shelton, C., & Normann, R. A. (2003) · The Laryngoscope · doi:10.1097/00005537-200305000-00012 · Cited by 38
Cochlear Electrode Arrays: Past, Present and Future
Spelman, F. A. (2006) · Audiology and Neurotology · doi:10.1159/000090680 · Cited by 36
Postoperative Dysphagia versus Neurogenic Dysphagia: Scintigraphic Assessment
Valenza, V., Gajate, A. M. S., Galli, J., D’Alatri, L., Girolamo, S. D., Reale, F., & Paludetti, G. (2003) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940311200106 · Cited by 30
Hüttenbrink, K., Zahnert, T., Jolly, C., et al. (2002) · Otology & Neurotology · doi:10.1097/00129492-200203000-00014 · Cited by 27
Anatomical Considerations and Long-Term Effects of Electrical Stimulation
Leake, P. A., & Rebscher, S. J. (2004) · Springer handbook of auditory research · doi:10.1007/978-0-387-22585-2_4 · Cited by 26
Prosthetic Stimulation of the Auditory System with Intraneural Electrodes
Arts, H. A., Jones, D. A., & Anderson, D. J. (2003) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894031120s905 · Cited by 22
Penetrating multichannel stimulation and recording electrodes in auditory prosthesis research
Anderson, D. J. (2008) · Hearing Research · doi:10.1016/j.heares.2008.01.010 · Cited by 20
Electrode Independence in Intraneural Cochlear Nerve Stimulation
Badi, A. N., Owa, A. O., Shelton, C., et al. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000244368.70190.38 · Cited by 16
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Cunningham, L. L., & Tucci, D. L. (2017) · New England Journal of Medicine · doi:10.1056/nejmra1616601 · Cited by 599
The Science of Neural Interface Systems
Hatsopoulos, N. G., & Donoghue, J. P. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135241 · Cited by 377
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
Metadata
- Authors
- Wilson, B. S., & Dorman, M. F.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 242
- Issue
- 1-2
- Pages
- 3-21
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W2023969516
- Cited by
- 868
- References
- 95
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.