Dimensionless correlations of frost properties on a cold cylinder surface
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The proposed correlation held good for Reynolds numbers of 700-3000, air temperatures of 3-9 °C, and cylinder surface temperatures of -32 to -20 °C.
“However, the proposed correlation held good for Reynolds numbers of 700-3000, air temperatures of 3-9 ° C and cylinder surface temperatures of 32 to 20 ° C.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Kim et al. [31]
Kim et al.'s proposed dimensionless correlations for cylindrical surface had a maximum error of 15% compared with experimental data.
“proposed dimensionless correlations for cylindrical surface with maximum error of 15% when compared with experimental data.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Kim et al. [31]
Frost thickness, frost surface temperature, and frost density were more uniformly distributed at high compared to low air velocities.
“The authors found that the frost thickness, frost surface temperature and frost density were more uniformly distributed at high compared to low air velocities.”
From Heat transfer characteristics of the heat exchangers for refrigeration, air conditioning and heat pump systems under frosting, defrosting and dry/wet conditions—A review (2017) · cites this paper as Kim et al. [31]
Only Kim et al. [31] presented frost density correlations of a cold cylinder, which were a function of Reynolds and Fourier numbers, air moisture content, cold surface temperature, and air temperature.
“only Kim et al. [31] presented frost density correlations of a cold cylinder, which were a function of Rey nolds and Fourier numbers, air moisture content, cold surface temper ature, and air temperature.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as Kim et al. [31]
Schneider's and Kim et al.'s average frost thickness correlations for cold cylinders are both functions of frosting duration, cold surface temperature, air temperature, and air moisture content or partial water vapor pressure.
“The similarity between Schneider ' s and Kim et al. ' s correlations was that both of them were the functions of frosting duration, cold surface tem perature, air temperature and air moisture content or partial water”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [31]
Only Schneider and Kim et al. presented average frost thickness correlations for cold cylinders.
“As can be seen from Table 2, only Schneider [30] and Kim et al. [31] presented average frost thickness correlations for cold cylinders.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [31]
Both frost thickness and density distributions along angular position on a cylinder become more uniform at a higher air velocity.
“It can be concluded that both the frost thickness and density distributions along angular position became more uniform at a higher air velocity.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [31]
On a cylinder, frost density at all angular positions and frost thickness at angular positions from 75° to 165° increase significantly at a higher air velocity, while frost thickness at other angular positions varies slightly.
“Besides, the frost density at all angular positions and frost thickness at those from 75 ◦ to 165 ◦ was increased significantly at a higher air velocity, while the frost thickness at other angular positions varied slightly.”
From Frosting mechanism and behaviors on surfaces with simple geometries: A state-of-the-art literature review (2022) · cites this paper as [31]
Cites
Dimensionless correlations of frost properties on a cold plate
Yang, D.-K., & Lee, K.-S. (2004) · International Journal of Refrigeration · doi:10.1016/s0140-7007(03)00118-x · Cited by 134 · see citing works
Self-citationAn experimental study of frost formation on a horizontal cylinder under cross flow
Lee, Y. B., & Ro, S. T. (2001) · International Journal of Refrigeration · doi:10.1016/s0140-7007(00)00073-6 · Cited by 95 · see citing works
Measurement and Correlation of Water Frost Thermal Conductivity and Density
Biguria, G., & Wenzel, L. A. (1970) · Industrial & Engineering Chemistry Fundamentals · doi:10.1021/i160033a021 · Cited by 75 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Frosting model for predicting macroscopic and local frost behaviors on a cold plate
Kim, D., Kim, C., & Lee, K.-S. (2015) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2014.11.048 · Cited by 103 · see citing works
Self-citationPatil, M. S., Seo, J.-H., & Lee, M.-Y. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.11.107 · Cited by 86 · see citing works
Zhang, L., Song, M., Deng, S., Shen, J., & Dang, C. (2022) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.118984 · Cited by 83 · see citing works
Experimental study of frost formation on cold surfaces with various fin layouts
Wu, X., Hu, S., & Chu, F. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.11.045 · Cited by 72 · see citing works
The behavior of frost layer growth under conditions favorable for desublimation
Lee, J., & Lee, K.-S. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.12.039 · Cited by 68 · see citing works
Self-citationKim, K., Kim, M.-H., Kim, D. R., & Lee, K.-S. (2014) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.12.060 · Cited by 64 · see citing works
Self-citationKim, K., Kim, D. R., & Lee, K.-S. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.05.027 · Cited by 46 · see citing works
Self-citationBenítez, T., & Sherif, S. A. (2017) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2017.01.026 · Cited by 27 · see citing works
Characteristics of frost formation on two-dimensional fins and its empirical correlations
Kim, K., Kim, J.-S., & Lee, K.-S. (2010) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2010.02.043 · Cited by 25 · see citing works
Self-citationLocal frost behaviors of a scaled-up louvered fin heat exchanger
Park, J.-S., Kim, D. R., & Lee, K.-S. (2015) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2015.06.025 · Cited by 24 · see citing works
Self-citation
- Authors
- Kim, J.-S., Yang, D.-K., & Lee, K.-S.
- Affiliations
- Hanyang University (KR)
- Corresponding author
- Lee, Kwan-Soo
- Venue
- International Journal of Heat and Mass Transfer
- Publisher
- Elsevier BV
- Published
- 2008-07
- Volume
- 51
- Issue
- 15-16
- Pages
- 3946-3952
- ISSN
- 0017-9310 (ISSN-L)
- OpenAlex
- W2158004512
- Cited by
- 57
- References
- 3
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 4 · 2022: 5 · 2021: 5 · 2020: 2 · 2019: 4 · 2017: 3 · 2016: 2 · 2015: 7 · 2014: 7 · 2013: 4 · 2012: 2
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Heat and Mass Transfer (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- frost layer, dimensionless correlation, frost thickness, frost density, heat transfer coefficient, air velocity, absolute humidity, Reynolds number, Fourier number, frost growth
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review