CoChat

Diagnostic accuracy of the CAM-ICU and ICDSC in detecting intensive care unit delirium: A bivariate meta-analysis

Chen, Ting-Jhen, Chung, Yi-Wei, Chang, Hui-Chen (Rita), Chen, Pin-Yuan, Wu, Chia-Rung, Hsieh, Shu-Hua, Chiu, Hsiao-Yean · 2021 · International Journal of Nursing Studies
Cited by 164

The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.

Abstract

BACKGROUND Delirium is a critical and highly prevalent problem among critically ill patients. The Confusion Assessment Method for the Intensive Care Unit (CAM-ICU) and the Intensive Care Delirium Screening Checklist (ICDSC) are the most recommended assessment tools for detecting intensive care unit (ICU) delirium. OBJECTIVES To synthesize the current evidence and compared the diagnostic accuracy of the two tools in the detection of delirium in adults in ICUs. DESIGN Systematic review and meta-analysis. DATA SOURCE A comprehensive search of the following electronic databases was performed using PubMed, Embase, CINAHL and ProQuest Dissertations and Theses A&I. The date range searched was from database inception to April 26, 2019. REVIEW METHODS Two researchers independently identified articles, systematically abstracted data and evaluated the sensitivity and specificity of the CAM-ICU or the ICDSC against standard references. Bivariate diagnostic statistical analysis with a random-effects model was performed to summarize the pooled sensitivity and specificity of the two tools. RESULTS In total, 29 CAM-ICU and 12 ICDSC studies were identified. The pooled sensitivity was 0.84 and 0.83 and pooled specificity was 0.95 and 0.87 for the CAM-ICU and the ICDSC, respectively. The CAM-ICU had higher summary specificity than the ICDSC did (p = 0.04). The percentage of hypoactive delirium, ICU type, use of mechanical ventilation, number of participants, and female percentage moderated the accuracy of the tools. Most of the domains of patient selection, index test, reference standards, and flow and timing were rated as having a low or unclear risk of bias. CONCLUSIONS Although both the CAM-ICU and the ICDSC are accurate assessment tools for screening delirium in critically ill patients, the CAM-ICU is superior in ruling out patients without ICU delirium and detecting delirium in patients in the medical ICU and those receiving mechanical ventilation. Further investigations are warranted to validate our findings. The study protocol is registered at PROSPERO (CRD42020133544).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ijnurstu.2020.103782

Cites

66 of 66 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Chen, T.-J., Chung, Y.-W., Chang, H.-C. (., Chen, P.-Y., Wu, C.-R., Hsieh, S.-H., & Chiu, H.-Y.
Venue
International Journal of Nursing Studies
Publisher
Elsevier BV
Published
2021-01
Volume
113
Pages
103782
ISSN
0020-7489 (ISSN-L)
OpenAlex
W3089535413
Cited by
164
References
66
FWCI
8.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.