The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Outcomes 2 Years After Transcatheter Aortic Valve Replacement in Patients at Low Surgical Risk
Open accessAbstract
BACKGROUND In low surgical risk patients with symptomatic severe aortic stenosis, the PARTNER 3 (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis) trial demonstrated superiority of transcatheter aortic valve replacement (TAVR) versus surgery for the primary endpoint of death, stroke, or re-hospitalization at 1 year. OBJECTIVES This study determined both clinical and echocardiographic outcomes between 1 and 2 years in the PARTNER 3 trial. METHODS This study randomly assigned 1,000 patients (1:1) to transfemoral TAVR with the SAPIEN 3 valve versus surgery (mean Society of Thoracic Surgeons score: 1.9%; mean age: 73 years) with clinical and echocardiography follow-up at 30 days and at 1 and 2 years. This study assessed 2-year rates of the primary endpoint and several secondary endpoints (clinical, echocardiography, and quality-of-life measures) in this as-treated analysis. RESULTS Primary endpoint follow-up at 2 years was available in 96.5% of patients. The 2-year primary endpoint was significantly reduced after TAVR versus surgery (11.5% vs. 17.4%; hazard ratio: 0.63; 95% confidence interval: 0.45 to 0.88; p = 0.007). Differences in death and stroke favoring TAVR at 1 year were not statistically significant at 2 years (death: TAVR 2.4% vs. surgery 3.2%; p = 0.47; stroke: TAVR 2.4% vs. surgery 3.6%; p = 0.28). Valve thrombosis at 2 years was increased after TAVR (2.6%; 13 events) compared with surgery (0.7%; 3 events; p = 0.02). Disease-specific health status continued to be better after TAVR versus surgery through 2 years. Echocardiographic findings, including hemodynamic valve deterioration and bioprosthetic valve failure, were similar for TAVR and surgery at 2 years. CONCLUSIONS At 2 years, the primary endpoint remained significantly lower with TAVR versus surgery, but initial differences in death and stroke favoring TAVR were diminished and patients who underwent TAVR had increased valve thrombosis. (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [PARTNER 3]; NCT02675114).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTranscatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationTranscatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationSurgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients
Reardon, M. J., Van Mieghem, N. M., Popma, J. J., Kleiman, N. S., Søndergaard, L., Mumtaz, M., Adams, D. H., Deeb, G. M., Maini, B., Gada, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1700456 · Cited by 3,009
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Self-citationUpdated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationGénéreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., Blackstone, E. H., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.02.038 · Cited by 1,313
Self-citationPossible Subclinical Leaflet Thrombosis in Bioprosthetic Aortic Valves
Makkar, R. R., Fontana, G., Jilaihawi, H., Chakravarty, T., Kofoed, K. F., De Backer, O., Asch, F. M., Ruiz, C. E., Olsen, N. T., Trento, A., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1509233 · Cited by 1,051
Self-citationVARC-3 WRITING COMMITTEE, Généreux, P., Piazza, N., Alu, M. C., Nazif, T., Hahn, R. T., Pibarot, P., Bax, J. J., Leipsic, J. A., Blanke, P., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa799 · Cited by 915
Self-citationChakravarty, T., Søndergaard, L., Friedman, J., De Backer, O., Berman, D., Kofoed, K. F., Jilaihawi, H., Shiota, T., Abramowitz, Y., Jørgensen, T. H., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30757-2 · Cited by 909
Self-citationKapadia, S. R., Leon, M. B., Makkar, R. R., Tuzcu, E. M., Svensson, L. G., Kodali, S., Webb, J. G., Mack, M. J., Douglas, P. S., Thourani, V. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60290-2 · Cited by 867
Self-citationFive-Year Outcomes of Transcatheter or Surgical Aortic-Valve Replacement
Makkar, R. R., Thourani, V. H., Mack, M. J., Kodali, S. K., Kapadia, S., Webb, J. G., Yoon, S.-H., Trento, A., Svensson, L. G., Herrmann, H. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa1910555 · Cited by 832
Self-citationCapodanno, D., Petronio, A. S., Prendergast, B., Eltchaninoff, H., Vahanian, A., Modine, T., Lancellotti, P., Sondergaard, L., Ludman, P. F., Tamburino, C., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx303 · Cited by 535
Dvir, D., Bourguignon, T., Otto, C. M., Hahn, R. T., Rosenhek, R., Webb, J. G., Treede, H., Sarano, M. E., Feldman, T., Wijeysundera, H. C., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030729 · Cited by 479
Self-citationGleason, T. G., Reardon, M. J., Popma, J. J., Deeb, G. M., Yakubov, S. J., Lee, J. S., Kleiman, N. S., Chetcuti, S., Hermiller, J. B., Heiser, J., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.2146 · Cited by 434
Kodali, S., Thourani, V. H., White, J., Malaisrie, S. C., Lim, S., Greason, K. L., Williams, M., Guerrero, M., Eisenhauer, A. C., Kapadia, S., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw112 · Cited by 352
Self-citationThyregod, H. G. H., Ihlemann, N., Jørgensen, T. H., Nissen, H., Kjeldsen, B. J., Petursson, P., Chang, Y., Franzen, O. W., Engstrøm, T., Clemmensen, P., et al. (2019) · Circulation · doi:10.1161/circulationaha.118.036606 · Cited by 337
Thourani, V. H., Suri, R. M., Gunter, R. L., Sheng, S., O’Brien, S. M., Ailawadi, G., Szeto, W. Y., Dewey, T. M., Guyton, R. A., Bavaria, J. E., et al. (2015) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2014.06.050 · Cited by 297
Self-citationEarly hypo-attenuated leaflet thickening in balloon-expandable transcatheter aortic heart valves
Pache, G., Schoechlin, S., Blanke, P., Dorfs, S., Jander, N., Arepalli, C. D., Gick, M., Buettner, H.-J., Leipsic, J., Langer, M., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv526 · Cited by 292
Self-citationAssessment of Paravalvular Regurgitation Following TAVR
Pibarot, P., Hahn, R. T., Weissman, N. J., & Monaghan, M. J. (2015) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.01.008 · Cited by 277
Self-citationPibarot, P., Ternacle, J., Jaber, W. A., Salaun, E., Dahou, A., Asch, F. M., Weissman, N. J., Rodriguez, L., Xu, K., Annabi, M.-S., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.049 · Cited by 217
Self-citationSystematic CT Methodology for the Evaluation of Subclinical Leaflet Thrombosis
Jilaihawi, H., Asch, F. M., Manasse, E., Ruiz, C. E., Jelnin, V., Kashif, M., Kawamori, H., Maeno, Y., Kazuno, Y., Takahashi, N., et al. (2017) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.02.005 · Cited by 201
Self-citationPîbarot, P., Salaün, E., Dahou, A., Avenatti, E., Guzzetti, E., Annabi, M., Toubal, O., Bernier, M., Beaudoin, J., Ong, G., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.044574 · Cited by 146
Self-citationBaron, S. J., Magnuson, E. A., Lu, M., Wang, K., Chinnakondepalli, K., Mack, M. J., Thourani, V. H., Kodali, S., Makkar, R., Herrmann, H. C., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.09.007 · Cited by 105
Self-citationThe sutureless aortic valve at 1 year: A large multicenter cohort study
Fischlein, T. J. M., Meuris, B., Hakim‐Meibodi, K., Misfeld, M., Carrel, T. P., Zembala, M., Gaggianesi, S., Madonna, F., Laborde, F., Asch, F. M., et al. (2016) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2015.12.064 · Cited by 100
Williams, M. L., Flynn, C. D., Mamo, A., Tian, D. H., Kappert, U., Wilbring, M., Folliguet, T. A., Fiore, A., Miceli, A., D’Onofrio, A., et al. (2020) · Annals of Cardiothoracic Surgery · doi:10.21037/acs-2020-surd-25 · Cited by 40
Self-citationTang, G. H. L., Verma, S., & Bhatt, D. L. (2019) · Circulation · doi:10.1161/circulationaha.119.041111 · Cited by 30
Uncertainty and Possible Subclinical Valve Leaflet Thrombosis
Holmes, D. R., & Mack, M. J. (2015) · New England Journal of Medicine · doi:10.1056/nejme1511683 · Cited by 23
Self-citationTranscatheter Aortic-Valve Replacement in Low-Risk Patients
Baldetti, L., Beneduce, A., & Gallone, G. (2019) · New England Journal of Medicine · doi:10.1056/nejmc1908500 · Cited by 17
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years
Mack, M. J., Leon, M. B., Thourani, V. H., Pibarot, P., Hahn, R. T., Genereux, P., Kodali, S. K., Kapadia, S. R., Cohen, D. J., Pocock, S. J., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307447 · Cited by 635
Self-citation2021 ESC/EACTS Guidelines for the management of valvular heart disease
Beyersdorf, F., Vahanian, A., Milojevic, M., Praz, F., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab389 · Cited by 622
Self-citationTranscatheter or surgical aortic valve implantation: 10-year outcomes of the NOTION trial
Thyregod, H. G. H., Jørgensen, T. H., Ihlemann, N., Steinbrüchel, D. A., Nissen, H., Kjeldsen, B. J., Petursson, P., De Backer, O., Olsen, P. S., & Søndergaard, L. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae043 · Cited by 383
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · EuroIntervention · doi:10.4244/eij-e-21-00009 · Cited by 372
Metadata
- Authors
- Leon, M. B., Mack, M. J., Hahn, R. T., Thourani, V. H., Makkar, R., Kodali, S. K., Alu, M. C., Madhavan, M. V., Chau, K. H., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Blanke, P., Leipsic, J. A., Williams, M. R., McCabe, J. M., Brown, D. L., Babaliaros, V., Goldman, S., Herrmann, H. C., Szeto, W. Y., Genereux, P., Pershad, A., Lu, M., Webb, J. G., Smith, C. R., & Pibarot, P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 77
- Issue
- 9
- Pages
- 1149-1161
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W3133691259
- Cited by
- 325
- References
- 33
- FWCI
- 39.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.