From low-cost sensors to high-quality data: A summary of challenges and best practices for effectively calibrating low-cost particulate matter mass sensors
Open accessThe DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Low-cost sensors for particulate matter mass (PM) enable spatially dense, high temporal resolution measurements of air quality that traditional reference monitoring cannot. Low-cost PM sensors are especially beneficial in low and middle-income countries where few, if any, reference grade measurements exist and in areas where the concentration fields of air pollutants have significant spatial gradients. Unfortunately, low-cost PM sensors also come with a number of challenges that must be addressed if their data products are to be used for anything more than a qualitative characterization of air quality. The various PM sensors used in low-cost monitors are all subject to biases and calibration dependencies, corrections for which range from relatively straightforward (e.g. meteorology, age of sensor) to complex (e.g. aerosol source, composition, refractive index). The methods for correcting and calibrating these biases and dependencies that have been used in the literature likewise range from simple linear and quadratic models to complex machine learning algorithms. Here we review the needs and challenges when trying to get high-quality data from low-cost sensors. We also present a set of best practices to follow to obtain high-quality data from these low-cost sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Elements of Statistical Learning
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7 · Cited by 25,970
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
The Elements of Statistical Learning: Data Mining, Inference, and Prediction
John Lu, Z. Q. (2010) · Journal of the Royal Statistical Society Series A: Statistics in Society · doi:10.1111/j.1467-985x.2010.00646_6.x · Cited by 12,390
Introduction to Machine Learning
Yu, F. R., & He, Y. (2019) · SpringerBriefs in Electrical and Computer Engineering · doi:10.1007/978-3-030-10546-4_1 · Cited by 1,594
Castell, N., Dauge, F. R., Schneider, P., Vogt, M., Lerner, U., Fishbain, B., Broday, D., & Bartonova, A. (2017) · Environment International · doi:10.1016/j.envint.2016.12.007 · Cited by 1,039
Morawska, L., Thai, P. K., Liu, X., Asumadu-Sakyi, A., Ayoko, G., Bartonova, A., Bedini, A., Chai, F., Christensen, B., Dunbabin, M., et al. (2018) · Environment International · doi:10.1016/j.envint.2018.04.018 · Cited by 864
An Introduction to Machine Learning
Badillo, S., Banfai, B., Birzele, F., Davydov, I. I., Hutchinson, L., Kam‐Thong, T., Siebourg‐Polster, J., Steiert, B., & Zhang, J. D. (2020) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1796 · Cited by 799
Beware of R2: Simple, Unambiguous Assessment of the Prediction Accuracy of QSAR and QSPR Models
Alexander, D. L. J., Tropsha, A., & Winkler, D. A. (2015) · Journal of Chemical Information and Modeling · doi:10.1021/acs.jcim.5b00206 · Cited by 745
A note on the validity of cross-validation for evaluating autoregressive time series prediction
Bergmeir, C., Hyndman, R. J., & Koo, B. (2018) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2017.11.003 · Cited by 743
Zimmerman, N., Presto, A. A., Kumar, S. P. N., Gu, J., Hauryliuk, A., Robinson, E. S., Robinson, A. L., & Subramanian, R. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-291-2018 · Cited by 566
Self-citationAmbient and laboratory evaluation of a low-cost particulate matter sensor
Kelly, K. E., Whitaker, J., Petty, A., Widmer, C., Dybwad, A., Sleeth, D., Martin, R., & Butterfield, A. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2016.12.039 · Cited by 498
Jiao, W., Hagler, G., Williams, R., Sharpe, R., Brown, R., Garver, D., Judge, R., Caudill, M., Rickard, J., Davis, M., et al. (2016) · Atmospheric Measurement Techniques · doi:10.5194/amt-9-5281-2016 · Cited by 484
Wang, Y., Li, J., Jing, H., Zhang, Q., Jiang, J., & Biswas, P. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1100710 · Cited by 471
Jayaratne, R. E., Liu, X., Thai, P. K., Dunbabin, M. D., & Morawska, L. (2018) · Atmospheric measurement techniques · doi:10.5194/amt-11-4883-2018 · Cited by 426
Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E. (2018) · Atmospheric Measurement Techniques · doi:10.5194/amt-11-4823-2018 · Cited by 418
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
Gao, M., Cao, J., & Seto, E. (2015) · Environmental Pollution · doi:10.1016/j.envpol.2015.01.013 · Cited by 345
Malings, C., Tanzer, R., Hauryliuk, A., Saha, P. K., Robinson, A. L., Presto, A. A., & Subramanian, R. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1623863 · Cited by 343
Self-citationPersonal exposure monitoring of PM 2.5 in indoor and outdoor microenvironments
Steinle, S., Reis, S., Sabel, C. E., Semple, S., Twigg, M. M., Braban, C. F., Leeson, S. R., Heal, M. R., Harrison, D., Lin, C., et al. (2015) · Science of The Total Environment · doi:10.1016/j.scitotenv.2014.12.003 · Cited by 337
Field calibrations of a low-cost aerosol sensor at a regulatory monitoring site in California
Holstius, D. M., Pillarisetti, A., Smith, K. R., & Seto, E. (2014) · Atmospheric Measurement Techniques · doi:10.5194/amt-7-1121-2014 · Cited by 312
Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Feenstra, B., Papapostolou, V., Hasheminassab, S., Zhang, H., Boghossian, B. D., Cocker, D., & Polidori, A. (2019) · Atmospheric Environment · doi:10.1016/j.atmosenv.2019.116946 · Cited by 265
Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor
Levy Zamora, M., Xiong, F., Gentner, D., Kerkez, B., Kohrman-Glaser, J., & Koehler, K. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b05174 · Cited by 244
Bulot, F. M. J., Johnston, S. J., Basford, P. J., Easton, N. H. C., Apetroaie-Cristea, M., Foster, G. L., Morris, A. K. R., Cox, S. J., & Loxham, M. (2019) · Scientific Reports · doi:10.1038/s41598-019-43716-3 · Cited by 241
Assessing the accuracy of low-cost optical particle sensors using a physics-based approach
Hagan, D. H., & Kroll, J. H. (2020) · Atmospheric Measurement Techniques · doi:10.5194/amt-13-6343-2020 · Cited by 231
Inter-comparison of low-cost sensors for measuring the mass concentration of occupational aerosols
Sousan, S., Koehler, K., Thomas, G., Park, J. H., Hillman, M., Halterman, A., & Peters, T. M. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1162901 · Cited by 220
Malings, C., Tanzer, R., Hauryliuk, A., Kumar, S. P. N., Zimmerman, N., Kara, L. B., Presto, A. A., & Subramanian, R. (2019) · Atmospheric Measurement Techniques · doi:10.5194/amt-12-903-2019 · Cited by 204
Self-citationMagi, B. I., Cupini, C., Francis, J., Green, M., & Hauser, C. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1619915 · Cited by 192
Stavroulas, I., Grivas, G., Michalopoulos, P., Liakakou, E., Bougiatioti, A., Kalkavouras, P., Fameli, K., Hatzianastassiou, N., Mihalopoulos, N., & Gerasopoulos, E. (2020) · Atmosphere · doi:10.3390/atmos11090926 · Cited by 183
Developing a Relative Humidity Correction for Low-Cost Sensors Measuring Ambient Particulate Matter
Di Antonio, A., Popoola, O. A. M., Ouyang, B., Saffell, J., & Jones, R. L. (2018) · Sensors · doi:10.3390/s18092790 · Cited by 180
Measurements of PM 2.5 with PurpleAir under atmospheric conditions
Ardon‐Dryer, K., Dryer, Y., Williams, J. N., & Moghimi, N. (2020) · Atmospheric measurement techniques · doi:10.5194/amt-13-5441-2020 · Cited by 174
Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor
Austin, E., Novosselov, I., Seto, E., & Yost, M. G. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137789 · Cited by 167
Evaluation of Nine Low-cost-sensor-based Particulate Matter Monitors
Li, J., Mattewal, S. K., Patel, S., & Biswas, P. (2020) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.12.0485 · Cited by 167
Zusman, M., Schumacher, C. S., Gassett, A. J., Spalt, E. W., Austin, E., Larson, T. V., Carvlin, G., Seto, E., Kaufman, J. D., & Sheppard, L. (2020) · Environment International · doi:10.1016/j.envint.2019.105329 · Cited by 162
Effects of aerosol type and simulated aging on performance of low-cost PM sensors
Tryner, J., Mehaffy, J., Miller-Lionberg, D., & Volckens, J. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105654 · Cited by 159
Field Evaluation of Low-Cost Particulate Matter Sensors for Measuring Wildfire Smoke
Holder, A. L., Mebust, A. K., Maghran, L. A., McGown, M. R., Stewart, K. E., Vallano, D. M., Elleman, R. A., & Baker, K. R. (2020) · Sensors · doi:10.3390/s20174796 · Cited by 148
Calibration of low-cost PurpleAir outdoor monitors using an improved method of calculating PM
Wallace, L. A., Bi, J., Ott, W. R., Sarnat, J. A., & Liu, Y. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118432 · Cited by 142
Airborne particulate matter monitoring in Kenya using calibrated low-cost sensors
Pope, F. D., Gatari, M. J., Ng’ang’a, D., Poynter, A., & Blake, R. (2018) · Atmospheric chemistry and physics · doi:10.5194/acp-18-15403-2018 · Cited by 131
Li, J., Li, H., Ma, Y., Wang, Y., Abokifa, A. A., Lu, C., & Biswas, P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.11.001 · Cited by 115
Bulot, F. M. J., Russell, H. S., Rezaei, M., Johnson, M. S., Ossont, S. J., Morris, A. K. R., Basford, P. J., Easton, N. H. C., Foster, G. L., Loxham, M., et al. (2020) · Sensors · doi:10.3390/s20082219 · Cited by 105
Performance characteristics of the low-cost Plantower PMS optical sensor
He, M., Kuerbanjiang, N., & Dhaniyala, S. (2019) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1696015 · Cited by 104
McFarlane, C., Isevulambire, P. K., Lumbuenamo, R. S., Ndinga, A. M. E., Dhammapala, R. S., Jin, X., McNeill, V. F., Malings, C., Subramanian, R., & Westervelt, D. M. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200619 · Cited by 97
Self-citationAir Quality Sensors and Data Adjustment Algorithms: When Is It No Longer a Measurement?
Hagler, G. S. W., Williams, R. W., Papapostolou, V., & Polidori, A. (2018) · Environmental Science & Technology · doi:10.1021/acs.est.8b01826 · Cited by 94
Williams, R. W., Duvall, R. M., Kilaru, V., Hagler, G. S. W., Hassinger, L., Benedict, K., Rice, J., Kaufman, A., Judge, R., Pierce, G., et al. (2019) · Atmospheric Environment X · doi:10.1016/j.aeaoa.2019.100031 · Cited by 94
Self-citationFederal Reference and Equivalent Methods for Measuring Fine Particulate Matter
Noble, C., Vanderpool, R. W., Peters, T. M., et al. (2001) · Aerosol Science and Technology · doi:10.1080/02786820121582 · Cited by 89
Barkjohn, K. K., Bergin, M., Norris, C. L., Schauer, J. J., Zhang, Y., Black, M., Hu, M., & Zhang, J. J. (2019) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.11.0394 · Cited by 79
Impacts of Modifiable Factors on Ambient Air Pollution: A Case Study of COVID-19 Shutdowns
Tanzer, R., Li, J., Eilenberg, S. R., Robinson, A. L., & Presto, A. A. (2020) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.0c00365 · Cited by 77
Self-citationSubramanian, R. (2020) · Clean Air Journal · doi:10.17159/caj/2020/30/2.8023 · Cited by 62
Self-citationBarkjohn, K. K., Norris, C. L., Cui, X., Fang, L., Zheng, T., Schauer, J. J., Li, Z., Zhang, Y., Black, M., Zhang, J. J., et al. (2020) · Indoor Air · doi:10.1111/ina.12716 · Cited by 61
Walser, A., Sauer, D. N., Spanu, A., Gasteiger, J., & Weinzierl, B. (2017) · Atmospheric measurement techniques · doi:10.5194/amt-10-4341-2017 · Cited by 58
Community-Based Measurements Reveal Unseen Differences during Air Pollution Episodes
Kelly, K. E., Xing, W. W., Sayahi, T., Mitchell, L. E., Becnel, T., Gaillardon, P., Meyer, M., & Whitaker, R. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c02341 · Cited by 58
Aerosol Chamber Characterization for Commercial Particulate Matter (PM) Sensor Evaluation
Hapidin, D. A., Saputra, C., Maulana, D. S., Munir, M. M., & Khairurrijal, K. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2017.12.0611 · Cited by 48
Mallia, D. V., Kochanski, A. K., Kelly, K. E., Whitaker, R., Xing, W. W., Mitchell, L. E., Jacques, A. A., Farguell, A., Mandel, J., Gaillardon, P., et al. (2020) · Journal of Geophysical Research Atmospheres · doi:10.1029/2020jd032712 · Cited by 47
Evaluation of low-cost optical particle counters for monitoring individual indoor aerosol sources
Salimifard, P., Rim, D., & Freihaut, J. D. (2019) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1697423 · Cited by 30
Wendt, E. A., Quinn, C. W., Miller-Lionberg, D., Tryner, J., L’Orange, C., Ford, B., Yalin, A. P., Pierce, J. R., Jathar, S. H., & Volckens, J. (2019) · Atmospheric measurement techniques · doi:10.5194/amt-12-5431-2019 · Cited by 29
Eilenberg, S. R., Subramanian, R., Malings, C., Hauryliuk, A., Presto, A. A., & Robinson, A. L. (2020) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-0255-x · Cited by 27
Self-citation
Metadata
- Authors
- Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R.
- Venue
- Journal of Aerosol Science
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 158
- Pages
- 105833
- ISSN
- 0021-8502 (ISSN-L)
- OpenAlex
- W3177891837
- Cited by
- 426
- References
- 55
- FWCI
- 21.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.