The clinical utility of professional continuous glucose monitoring by pharmacists for patients with type 2 diabetes
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
BACKGROUND There are limited data regarding the use of diabetes technologies, such as professional continuous glucose monitoring (CGM), as part of a pharmacist-managed diabetes service. OBJECTIVE To assess how professional CGM affected treatment decisions and glucose control as part of a pharmacist-managed service for patients with type 2 diabetes. PRACTICE DESCRIPTION Clinical Pharmacy Specialists (CPS's) within an outpatient diabetes management service provide comprehensive diabetes care under a scope of practice that includes prescriptive privileges. PRACTICE INNOVATION Insight into glucose patterns is paramount for pharmacists to use their medication expertise to its fullest capacity. CGM technology can provide detailed data on glucose trends, including percentage of time spent in a target range. Pharmacists involved in the provision of diabetes care have the opportunity to integrate professional CGM into their practice to acquire data for targeted therapeutic adjustments. EVALUATION METHODS A retrospective analysis was conducted of patients with type 2 diabetes who had professional CGM used as part of their routine diabetes care with the CPS from 2017-2019. The primary outcome was the percentage of patients meeting their individualized A1c goal at baseline versus 6 months post placement of the professional CGM. A McNemar's test was used to compare the percentage of patients achieving A1c goal pre and postintervention. A P value of <0.05 denoted the presence of a statistically significant difference. RESULTS Patients who implemented professional CGM had an average duration of diabetes of 15.6 years and an average A1c of 9.1%. The majority (76.7%) were not meeting their individualized A1c goal. Hypoglycemia was identified in 57% of the patients; almost half of patients evaluated had periods of nocturnal hypoglycemia. Hyperglycemia was present on the vast majority of reports (83%) with postprandial elevations being the most common trend identified overall. Mean A1c decreased from 9.11% ± 1.4 at baseline to 8.64% ± 1.3 at 3 months and 8.19% ± 0.8 at 6 months. Compared with baseline, more than 2 times the number of patients were within their A1c goal range at 3 and 6 months (23.3%, 53.6% and 69.6% respectively.) This represented a statistically significant difference at both time points (P = 0.008 at 3 months and P = 0.006 at 6 months.) CONCLUSION: The use of CGM technology may overcome treatment barriers, such as insufficient self-monitoring of blood glucose and lack of discernment of glucose trends with traditional A1c testing. Pharmacists employing professional CGM as part of a diabetes management service were able to achieve targets for significantly more patients with type 2 diabetes on a wide range of treatment regimens at 6 months compared with baseline. Widespread use of professional CGM in pharmacist-managed diabetes services may provide valuable care and improve outcomes more broadly. Larger randomized trials are warranted to examine ideal patient selection and optimal frequency of use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250
Fonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
Sierra, J. A., Shah, M., Gill, M. S., Flores, Z., Chawla, H., Kaufman, F. R., & Vigersky, R. (2018) · Journal of Medical Economics · doi:10.1080/13696998.2017.1390474 · Cited by 38
Testing times! Choosing Wisely when it comes to monitoring type 2 diabetes
Speight, J., Browne, J. L., & Furler, J. S. (2015) · Medical Journal of Australia · doi:10.5694/mja15.00639 · Cited by 12
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Nemlekar, P. M., Hannah, K. L., & Norman, G. J. (2023) · Clinical Diabetes · doi:10.2337/cd22-0080 · Cited by 10
Metadata
- Authors
- Ulrich, H., & Bowen, M.
- Venue
- Journal of the American Pharmacists Association
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 61
- Issue
- 6
- Pages
- e76-e82
- ISSN
- 1544-3191 (ISSN-L)
- OpenAlex
- W3170747376
- Cited by
- 27
- References
- 9
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.