The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
A Multisensor Algorithm Predicts Heart Failure Events in Patients With Implanted Devices
Open accessAbstract
OBJECTIVES: The aim of this study was to develop and validate a device-based diagnostic algorithm to predict heart failure (HF) events. BACKGROUND: HF involves costly hospitalizations with adverse impact on patient outcomes. The authors hypothesized that an algorithm combining a diverse set of implanted device-based sensors chosen to target HF pathophysiology could detect worsening HF. METHODS: The MultiSENSE (Multisensor Chronic Evaluation in Ambulatory Heart Failure Patients) study enrolled patients with investigational chronic ambulatory data collection via implanted cardiac resynchronization therapy defibrillators. HF events (HFEs), defined as HF admissions or unscheduled visits with intravenous treatment, were independently adjudicated. The development cohort of patients was used to construct a composite index and alert algorithm (HeartLogic) combining heart sounds, respiration, thoracic impedance, heart rate, and activity; the test cohort was sequestered for independent validation. The 2 coprimary endpoints were sensitivity to detect HFE >40% and unexplained alert rate <2 alerts per patient-year. RESULTS: Overall, 900 patients (development cohort, n = 500; test cohort, n = 400) were followed for up to 1 year. Coprimary endpoints were evaluated using 320 patient-years of follow-up data and 50 HFEs in the test cohort (72% men; mean age 66.8 ± 10.3 years; New York Heart Association functional class at enrollment: 69% in class II, 25% in class III; mean left ventricular ejection fraction 30.0 ± 11.4%). Both endpoints were significantly exceeded, with sensitivity of 70% (95% confidence interval [CI]: 55.4% to 82.1%) and an unexplained alert rate of 1.47 per patient-year (95% CI: 1.32 to 1.65). The median lead time before HFE was 34.0 days (interquartile range: 19.0 to 66.3 days). CONCLUSIONS: The HeartLogic multisensor index and alert algorithm provides a sensitive and timely predictor of impending HF decompensation. (Evaluation of Multisensor Data in Heart Failure Patients With Implanted Devices [MultiSENSE]; NCT01128166).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., Das, S. R., de Ferranti, S., Després, J.-P., Fullerton, H. J., et al. (2016) · Circulation · doi:10.1161/cir.0000000000000350 · Cited by 6,596
Abraham, W. T., Adamson, P. B., Bourge, R. C., Aaron, M. F., Costanzo, M. R., Stevenson, L. W., Strickland, W., Neelagaru, S., Raval, N., Krueger, S., et al. (2011) · The Lancet · doi:10.1016/s0140-6736(11)60101-3 · Cited by 1,744
Telemonitoring in patients with heart failure
Chaudhry, S. I., Mattera, J. A., Curtis, J. P., Spertus, J. A., Herrin, J., Lin, Z., Phillips, C. O., Hodshon, B. V., Cooper, L. S., & Krumholz, H. M. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1010029 · Cited by 1,232
Hindricks, G., Taborsky, M., Glikson, M., Heinrich, U., Schumacher, B., Katz, A., Brachmann, J., Lewalter, T., Goette, A., Block, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61176-4 · Cited by 740
Yu, C.-M., Wang, L., Chau, E., Chan, R. H.-W., Kong, S.-L., Tang, M.-O., Christensen, J., Stadler, R. W., & Lau, C.-P. (2005) · Circulation · doi:10.1161/circulationaha.104.492207 · Cited by 711
Abraham, W. T., Stevenson, L. W., Bourge, R. C., Lindenfeld, J. A., Bauman, J. G., & Adamson, P. B. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00723-0 · Cited by 612
van Veldhuisen, D. J., Braunschweig, F., Conraads, V., Ford, I., Cowie, M. R., Jondeau, G., Kautzner, J., Muñoz Aguilera, R., Lunati, M., Yu, C. M., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.043042 · Cited by 444
Whellan, D. J., Ousdigian, K. T., Al-Khatib, S. M., Pu, W., Sarkar, S., Porter, C. B., Pavri, B. B., & O'Connor, C. M. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.089 · Cited by 374
Conraads, V. M., Tavazzi, L., Santini, M., Oliva, F., Gerritse, B., Yu, C.-M., & Cowie, M. R. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr050 · Cited by 298
Fluid status telemedicine alerts for heart failure: a randomized controlled trial
Böhm, M., Drexler, H., Oswald, H., Rybak, K., Bosch, R., Butter, C., Klein, G., Gerritse, B., Monteiro, J., Israel, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw099 · Cited by 256
Abraham, W. T., Compton, S., Haas, G., Foreman, B., Canby, R. C., Fishel, R., McRae, S., Toledo, G. B., Sarkar, S., Hettrick, D. A., et al. (2011) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2011.00220.x · Cited by 224
Cowie, M. R., Sarkar, S., Koehler, J., Whellan, D. J., Crossley, G. H., Tang, W. H. W., Abraham, W. T., Sharma, V., & Santini, M. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht083 · Cited by 164
Loh, J. P.-Y., Barbash, I. M., & Waksman, R. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.1035 · Cited by 57
Heist, E. K., Herre, J. M., Binkley, P. F., Bakel, A. B. V., Porterfield, J. G., Porterfield, L. M., Qu, F., Turkel, M., & Pavri, B. B. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.07.048 · Cited by 57
Auricchio, A., Gold, M. R., Brugada, J., Nölker, G., Arunasalam, S., Leclercq, C., Defaye, P., Calò, L., Baumann, O., & Leyva, F. (2014) · European Journal of Heart Failure · doi:10.1002/ejhf.79 · Cited by 31
Device monitoring strategies in acute heart failure syndromes
Samara, M. A., & Tang, W. H. W. (2011) · Heart Failure Reviews · doi:10.1007/s10741-011-9236-4 · Cited by 16
Cited by
Heart Failure After Myocardial Infarction: Incidence and Predictors
Jenča, D., Melenovský, V., Stehlik, J., Staněk, V., Kettner, J., Kautzner, J., Adámková, V., & Wohlfahrt, P. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13144 · Cited by 605
Stehlik, J., Schmalfuss, C., Bozkurt, B., Nativi-Nicolau, J., Wohlfahrt, P., Wegerich, S., Rose, K., Ray, R., Schofield, R., Deswal, A., et al. (2020) · Circulation Heart Failure · doi:10.1161/circheartfailure.119.006513 · Cited by 333
Rossignol, P., Hernandez, A. F., Solomon, S. D., & Zannad, F. (2019) · The Lancet · doi:10.1016/s0140-6736(18)31808-7 · Cited by 316
Machine learning in clinical decision making
Adlung, L., Cohen, Y., Mor, U., & Elinav, E. (2021) · Med · doi:10.1016/j.medj.2021.04.006 · Cited by 282
The role of wearables in heart failure
Singhal, A., & Cowie, M. R. (2020) · Current Heart Failure Reports · doi:10.1007/s11897-020-00467-x · Cited by 85
Metadata
- Authors
- Boehmer, J. P., Hariharan, R., Devecchi, F. G., Smith, A. L., Molon, G., Capucci, A., An, Q., Averina, V., Stolen, C. M., Thakur, P. H., Thompson, J. A., Wariar, R., Zhang, Y., & Singh, J. P.
- Venue
- JACC: Heart Failure
- Publisher
- Elsevier BV
- Published
- 2017-03
- Volume
- 5
- Issue
- 3
- Pages
- 216-225
- ISSN
- 2213-1779 (ISSN-L)
- OpenAlex
- W2593822183
- Cited by
- 393
- References
- 17
- FWCI
- 17.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.