The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement
Open accessAbstract
Transcatheter aortic valve replacement (TAVR) is a safe and feasible alternative to surgery in patients with symptomatic severe aortic stenosis regardless of the surgical risk. Conduction abnormalities requiring permanent pacemaker (PPM) implantation remain a common finding after TAVR due to the close proximity of the atrioventricular conduction system to the aortic root. High-grade atrioventricular block and new onset left bundle branch block (LBBB) are the most commonly reported conduction abnormalities after TAVR. The overall rate of PPM implantation after TAVR varies and is related to pre-procedural and intraprocedural factors. The available literature regarding the impact of conduction abnormalities and PPM requirement on morbidity and mortality is still conflicting. Pre-procedural conduction abnormalities such as right bundle branch block and LBBB have been linked with increased PPM implantation and mortality after TAVR. When screening patients for TAVR, heart teams should be aware of various anatomical and pathophysiological conditions that make patients more susceptible to increased risk of conduction abnormalities and PPM requirement after the procedure. This is particularly important as TAVR has been recently approved for patients with low surgical risk. The purpose of this review is to discuss the incidence, predictors, impact, and management of the various conduction abnormalities requiring PPM implantation in patients undergoing TAVR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Siontis, G. C. M., Jüni, P., Pilgrim, T., Stortecky, S., Büllesfeld, L., Meier, B., Wenaweser, P., & Windecker, S. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.033 · Cited by 647
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Self-citationPercutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
Reddy, V. Y., Exner, D. V., Cantillon, D. J., Doshi, R., Bunch, T. J., Tomassoni, G. F., Friedman, P. A., Estes, N. A. M., Ip, J., Niazi, I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1507192 · Cited by 539
Nazif, T. M., Dizon, J. M., Hahn, R. T., Xu, K., Babaliaros, V., Douglas, P. S., El-Chami, M. F., Herrmann, H. C., Mack, M., Makkar, R. R., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.07.022 · Cited by 532
Management of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement
Rodés-Cabau, J., Ellenbogen, K. A., Krahn, A. D., Latib, A., Mack, M., Mittal, S., Muntané-Carol, G., Nazif, T. M., Sondergaard, L., Urena, M., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.07.014 · Cited by 344
Fadahunsi, O. O., Olowoyeye, A., Ukaigwe, A., Li, Z., Vora, A. N., Vemulapalli, S., Elgin, E., & Donato, A. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.026 · Cited by 335
Urena, M., Webb, J. G., Tamburino, C., Muñoz-García, A. J., Cheema, A., Dager, A. E., Serra, V., Amat-Santos, I. J., Barbanti, M., Immè, S., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005479 · Cited by 304
Cited by
Springhetti, P., Abdoun, K., & Clavel, M.-A. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13144237 · Cited by 24
Metadata
- Authors
- Sammour, Y., Krishnaswamy, A., Kumar, A., Puri, R., Tarakji, K. G., Bazarbashi, N., Harb, S., Griffin, B., Svensson, L., Wazni, O., & Kapadia, S. R.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 14
- Issue
- 2
- Pages
- 115-134
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W3121851336
- Cited by
- 255
- References
- 65
- FWCI
- 24.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement. https://app.cochat.ai/papers/10.1016/j.jcin.2020.09.063
- The paper
- Sammour, Y., Krishnaswamy, A., Kumar, A., Puri, R., Tarakji, K. G., Bazarbashi, N., Harb, S., Griffin, B., Svensson, L., Wazni, O., & Kapadia, S. R. (2021). Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2020.09.063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.