The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement
Open accessAbstract
Transcatheter aortic valve replacement (TAVR) is a safe and feasible alternative to surgery in patients with symptomatic severe aortic stenosis regardless of the surgical risk. Conduction abnormalities requiring permanent pacemaker (PPM) implantation remain a common finding after TAVR due to the close proximity of the atrioventricular conduction system to the aortic root. High-grade atrioventricular block and new onset left bundle branch block (LBBB) are the most commonly reported conduction abnormalities after TAVR. The overall rate of PPM implantation after TAVR varies and is related to pre-procedural and intraprocedural factors. The available literature regarding the impact of conduction abnormalities and PPM requirement on morbidity and mortality is still conflicting. Pre-procedural conduction abnormalities such as right bundle branch block and LBBB have been linked with increased PPM implantation and mortality after TAVR. When screening patients for TAVR, heart teams should be aware of various anatomical and pathophysiological conditions that make patients more susceptible to increased risk of conduction abnormalities and PPM requirement after the procedure. This is particularly important as TAVR has been recently approved for patients with low surgical risk. The purpose of this review is to discuss the incidence, predictors, impact, and management of the various conduction abnormalities requiring PPM implantation in patients undergoing TAVR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht150 · Cited by 2,809
Siontis, G. C. M., Jüni, P., Pilgrim, T., Stortecky, S., Büllesfeld, L., Meier, B., Wenaweser, P., & Windecker, S. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.033 · Cited by 647
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017) · Circulation · doi:10.1161/circulationaha.117.028352 · Cited by 550
Self-citationPercutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
Reddy, V. Y., Exner, D. V., Cantillon, D. J., Doshi, R., Bunch, T. J., Tomassoni, G. F., Friedman, P. A., Estes, N. A. M., Ip, J., Niazi, I., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1507192 · Cited by 539
Nazif, T. M., Dizon, J. M., Hahn, R. T., Xu, K., Babaliaros, V., Douglas, P. S., El-Chami, M. F., Herrmann, H. C., Mack, M., Makkar, R. R., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.07.022 · Cited by 532
Management of Conduction Disturbances Associated With Transcatheter Aortic Valve Replacement
Rodés-Cabau, J., Ellenbogen, K. A., Krahn, A. D., Latib, A., Mack, M., Mittal, S., Muntané-Carol, G., Nazif, T. M., Sondergaard, L., Urena, M., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.07.014 · Cited by 344
Fadahunsi, O. O., Olowoyeye, A., Ukaigwe, A., Li, Z., Vora, A. N., Vemulapalli, S., Elgin, E., & Donato, A. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.07.026 · Cited by 335
Urena, M., Webb, J. G., Tamburino, C., Muñoz-García, A. J., Cheema, A., Dager, A. E., Serra, V., Amat-Santos, I. J., Barbanti, M., Immè, S., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005479 · Cited by 304
van Rosendael, P. J., Delgado, V., & Bax, J. J. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx785 · Cited by 292
Regueiro, A., Abdul-Jawad Altisent, O., Del Trigo, M., Campelo-Parada, F., Puri, R., Urena, M., Philippon, F., & Rodés-Cabau, J. (2016) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.115.003635 · Cited by 287
Self-citationLeft Bundle-Branch Block Induced by Transcatheter Aortic Valve Implantation Increases Risk of Death
Houthuizen, P., Van Garsse, L. A. F. M., Poels, T. T., de Jaegere, P., van der Boon, R. M. A., Swinkels, B. M., ten Berg, J. M., van der Kley, F., Schalij, M. J., Baan, J., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.101055 · Cited by 278
Urena, M., Mok, M., Serra, V., Dumont, E., Nombela-Franco, L., DeLarochellière, R., Doyle, D., Igual, A., Larose, E., Amat-Santos, I., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.035 · Cited by 266
Atrioventricular Synchronous Pacing Using a Leadless Ventricular Pacemaker
Steinwender, C., Khelae, S. K., Garweg, C., Chan, J. Y. S., Ritter, P., Johansen, J. B., Sagi, V., Epstein, L. M., Piccini, J. P., Pascual, M., et al. (2020) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2019.10.017 · Cited by 257
Late Cardiac Death in Patients Undergoing Transcatheter Aortic Valve Replacement
Urena, M., Webb, J. G., Eltchaninoff, H., Muñoz-García, A. J., Bouleti, C., Tamburino, C., Nombela-Franco, L., Nietlispach, F., Moris, C., Ruel, M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.11.027 · Cited by 235
Nazif, T. M., Williams, M. R., Hahn, R. T., Kapadia, S., Babaliaros, V., Rodés-Cabau, J., Szeto, W. Y., Jilaihawi, H., Fearon, W. F., Dvir, D., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/eht376 · Cited by 230
Self-citationBuellesfeld, L., Stortecky, S., Heg, D., Hausen, S., Mueller, R., Wenaweser, P., Pilgrim, T., Gloekler, S., Khattab, A. A., Huber, C., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.054 · Cited by 212
Chamandi, C., Barbanti, M., Munoz-Garcia, A., Latib, A., Nombela-Franco, L., Gutiérrez-Ibanez, E., Veiga-Fernandez, G., Cheema, A. N., Cruz-Gonzalez, I., Serra, V., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.10.032 · Cited by 174
Urena, M., Webb, J. G., Cheema, A., Serra, V., Toggweiler, S., Barbanti, M., Cheung, A., Ye, J., Dumont, E., DeLarochellière, R., et al. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2013.08.015 · Cited by 171
Testa, L., Latib, A., De Marco, F., De Carlo, M., Agnifili, M., Latini, R. A., Petronio, A. S., Ettori, F., Poli, A., De Servi, S., et al. (2013) · Circulation · doi:10.1161/circulationaha.112.001099 · Cited by 162
Visualizing anatomical evidences on atrioventricular conduction system for TAVI
Kawashima, T., & Sato, F. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.04.003 · Cited by 161
Toggweiler, S., Stortecky, S., Holy, E. W., Zuk, K., Cuculi, F., Nietlispach, F., Sabti, Z., Suciu, R., Maier, W., Jamshidi, P., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.03.024 · Cited by 150
Nazif, T. M., Chen, S., George, I., Dizon, J. M., Hahn, R. T., Crowley, A., Alu, M. C., Babaliaros, V. C., Thourani, V. H., Herrmann, H. C., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz227 · Cited by 145
Self-citationPalmisano, P., Accogli, M., Zaccaria, M., Luzzi, G., Nacci, F., Anaclerio, M., & Favale, S. (2013) · EP Europace · doi:10.1093/europace/eus337 · Cited by 141
Arnold, S. V., Zhang, Y., Baron, S. J., McAndrew, T., Alu, M. C., Kodali, S., Kapadia, S. R., Thourani, V. H., Miller, D. C., Mack, M. J., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.11.008 · Cited by 137
Self-citationChronic pacing and adverse outcomes after transcatheter aortic valve implantation
Dizon, J. M., Nazif, T. M., Hess, P. L., BIVIANO, A. B., Garan, H., Douglas, P. S., Kapadia, S. R., Babaliaros, V. C., Herrmann, H. C., Szeto, W. Y., et al. (2015) · Heart · doi:10.1136/heartjnl-2015-307666 · Cited by 131
Self-citationCarlo, M. D., Giannini, C., Bedogni, F., Klugmann, S., Brambilla, N., MARCO, F. D., Zucchelli, G., Testa, L., Oreglia, J., & Petronio, A. S. (2012) · American Heart Journal · doi:10.1016/j.ahj.2011.12.009 · Cited by 122
Auffret, V., Webb, J. G., Eltchaninoff, H., Muñoz-García, A. J., Himbert, D., Tamburino, C., y, L. N.-F., Nietlispach, F., Morı́s, C., Ruel, M., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.05.030 · Cited by 121
Self-citationSchymik, G., Tzamalis, P., Bramlage, P., et al. (2014) · Clinical Research in Cardiology · doi:10.1007/s00392-014-0791-2 · Cited by 115
Long-Term Outcomes in Patients With New-Onset Persistent Left Bundle Branch Block Following TAVR
Chamandi, C., Barbanti, M., Muñoz-García, A. J., Latib, A., y, L. N.-F., Gutiérrez, E., Fernández, G. V., Cheema, A. N., Cruz‐González, I., Serra, V., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.03.025 · Cited by 112
Self-citationCosta, G., Zappulla, P., Barbanti, M., et al. (2019) · EuroIntervention · doi:10.4244/eij-d-18-01060 · Cited by 109
Mangieri, A., Lanzillo, G., Bertoldi, L. F., Jabbour, R. J., Regazzoli, D., Ancona, M., Tanaka, A., Mitomo, S., Garducci, S., Montalto, C., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.06.014 · Cited by 103
Tricuspid Regurgitation and Implantable Devices
Al‐Bawardy, R., Krishnaswamy, A., Rajeswaran, J., Bhargava, M., Wazni, O. M., Wilkoff, B. L., Tuzcu, E. M., Martin, D. O., Thomas, J. D., Blackstone, E. H., et al. (2014) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12530 · Cited by 98
Self-citationWatanabe, Y., Kozuma, K., Hioki, H., et al. (2016) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2016.08.035 · Cited by 97
Kiani, S., Kamioka, N., Black, G. B., Lu, M. L. R. Y., Lisko, J. C., Rao, B., Mengistu, A., Gleason, P. T., Stewart, P., Caughron, H., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2019.07.015 · Cited by 97
TAVI and Post Procedural Cardiac Conduction Abnormalities
Mangieri, A., Montalto, C., Pagnesi, M., Lanzillo, G., Demir, O. M., Testa, L., Colombo, A., & Latib, A. (2018) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2018.00085 · Cited by 87
Jørgensen, T. H., Backer, O. D., Gerds, T. A., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.04.011 · Cited by 81
Fujita, B., Schmidt, T., Bleiziffer, S., Bauer, T., Beckmann, A., Bekeredjian, R., Möllmann, H., Walther, T., Landwehr, S., Hamm, C. W., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz168 · Cited by 77
Permanent His-bundle pacing in patients with prosthetic cardiac valves
Sharma, P. S., Subzposh, F. A., Ellenbogen, K. A., & Vijayaraman, P. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.09.016 · Cited by 67
Mouillet, G., Lellouche, N., Yamamoto, M., Oguri, A., Dubois‐Randé, J., BELLE, E. V., Gilard, M., Laskar, M., & Teíger, E. (2015) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.25818 · Cited by 64
Biner, S., Michowitz, Y., Leshem‐Rubinow, E., Topilsky, Y., Ben–Assa, E., Shimiaie, J., Banai, S., Keren, G., Steinvil, A., & Finkelstein, A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.09.030 · Cited by 63
Aljabbary, T. F., Qiu, F., Masih, S. P., Fang, J., Elbaz‐Greener, G., Austin, P. C., Rodés‐Cabau, J., Ko, D. T., Singh, S. M., & Wijeysundera, H. C. (2018) · JAMA Network Open · doi:10.1001/jamanetworkopen.2018.0088 · Cited by 61
Mohananey, D., Jobanputra, Y. B., Kumar, A., Krishnaswamy, A., Mick, S., White, J., & Kapadia, S. R. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005046 · Cited by 60
Self-citationGiustino, G., van der Boon, R. M. A., de Nicolás, J. M.-M., et al. (2016) · EuroIntervention · doi:10.4244/eijv12i9a192 · Cited by 55
Cause of death after transcatheter aortic valve implantation
Mieghem, N. M. V., van der Boon, R. M., Nuis, R.-J. M., Schultz, C. J., van Geuns, R., Serruys, P. W. J. C., Kappetein, A. P., van Domburg, R. T., & de Jaegere, P. P. T. (2012) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.24597 · Cited by 52
New-Onset Left Bundle Branch Block Induced by Transcutaneous Aortic Valve Implantation
Massoullié, G., Bordachar, P., Ellenbogen, K. A., Souteyrand, G., Jean, F., Combaret, N., Vorilhon, C., Clerfond, G., Farhat, M., Ritter, P., et al. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.12.009 · Cited by 51
Impact of Preexisting Left Bundle Branch Block in Transcatheter Aortic Valve Replacement Recipients
Fischer, Q., Himbert, D., Webb, J. G., Eltchaninoff, H., Muñoz-García, A. J., Tamburino, C., y, L. N.-F., Nietlispach, F., Morís, C., Ruel, M., et al. (2018) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.006927 · Cited by 48
Rogers, T., Devraj, M., Thomaides, A. X., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.02.015 · Cited by 46
Gensas, C. S., Caixeta, A. M., Siqueira, D., Carvalho, L. A. F., Sarmento‐Leite, R., Mangione, J. A., Lemos, P. A., Colafranceschi, A. S., Caramori, P., Ferreira, M. C. M., et al. (2014) · International Journal of Cardiology · doi:10.1016/j.ijcard.2014.05.020 · Cited by 45
Nadeem, F., Tsushima, T., Ladas, T. P., Thomas, R., Patel, S. M., Saric, P., Patel, T. R., Lipinski, J., Li, J., Costa, M. A., et al. (2018) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2018.07.046 · Cited by 42
Pooter, J. D., Gauthey, A., Calle, S., Noël, A., Kefer, J., Marchandise, S., Coeman, M., Philipsen, T. E., Kayaert, P., Gheeraert, P. J., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14371 · Cited by 41
Conduction recovery and avoidance of permanent pacing after transcatheter aortic valve implantation
Marzahn, C., Koban, C., Seifert, M., Isotani, A., Neuß, M., Hölschermann, F., & Butter, C. (2017) · Journal of Cardiology · doi:10.1016/j.jjcc.2017.06.007 · Cited by 39
Reul, R. M., Ramchandani, M. K., & Reardon, M. J. (2017) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-13-3-132 · Cited by 36
Dumonteil, N., Meredith, I. T., Blackman, D. J., Tchétché, D., Hildick‐Smith, D., Spence, M., Walters, D., Harnek, J., Worthley, S. G., Rioufol, G., et al. (2017) · EuroIntervention · doi:10.4244/eij-d-16-01025 · Cited by 31
Egger, F., Nürnberg, M., Rohla, M., Weiss, T. W., Unger, G., Smetana, P., Geppert, A., Gruber, S. C., Bambazek, A., Falkensammer, J., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.014 · Cited by 30
Massoullié, G., Bordachar, P., Irles, D., Caussin, C., Costa, A. D., Defaye, P., Jean, F., Mechulan, A., Mondoly, P., Souteyrand, G., et al. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010485 · Cited by 24
Bhardwaj, A., Ramanan, T., Sawant, A. C., Sinibaldi, E., Pham, M., Khan, S., Qureshi, R., Agrawal, N., Khalil, C., Hansen, R., et al. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12065 · Cited by 22
Alasti, M., Rashid, H. N. Z., Rangasamy, K., Kotschet, E., Adam, D. C., Alison, J., Gooley, R., & Zaman, S. J. (2018) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.27463 · Cited by 21
Effect of permanent pacemaker on mortality after transcatheter aortic valve replacement
Engborg, J., Riechel-Sarup, C., Gerke, O., Mickley, H., Sandgaard, N. C. F., Nissen, H., & Diederichsen, A. C. P. (2016) · Scandinavian Cardiovascular Journal · doi:10.1080/14017431.2016.1236982 · Cited by 19
Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Cost Analysis
Ahmad, M., Patel, J. N., Loc, B. L., Vipparthy, S. C., Divecha, C., Barzallo, P. X., Kim, M. C., Baman, T. S., Barzallo, M. A., & Mungee, S. (2019) · Cureus · doi:10.7759/cureus.5005 · Cited by 19
Kawaguchi, A. T., D'Allessandro, C., Collet, J., Cluzel, P., Makri, R., & Leprince, P. N. (2015) · Artificial Organs · doi:10.1111/aor.12393 · Cited by 17
Gonska, B., Keßler, M., Wöhrle, J., Rottbauer, W., & Seeger, J. (2018) · Netherlands Heart Journal · doi:10.1007/s12471-018-1194-1 · Cited by 17
Shivamurthy, P., Vejpongsa, P., Gurung, S., Jacob, R., Zhao, Y., Anderson, H. V., Balan, P., Nguyen, T. C., Estrera, A. L., DOUGHERTY, A. H., et al. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13910 · Cited by 16
Disarming the Ticking Time Bomb
Nazif, T. M., Chen, S., & Kodali, S. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.07.003 · Cited by 5
Cited by
Springhetti, P., Abdoun, K., & Clavel, M.-A. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13144237 · Cited by 24
Metadata
- Authors
- Sammour, Y., Krishnaswamy, A., Kumar, A., Puri, R., Tarakji, K. G., Bazarbashi, N., Harb, S., Griffin, B., Svensson, L., Wazni, O., & Kapadia, S. R.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 14
- Issue
- 2
- Pages
- 115-134
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W3121851336
- Cited by
- 255
- References
- 65
- FWCI
- 24.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.