Computational modeling of cardiac hemodynamics: Current status and future outlook
Open accessThe DOI matches its Crossref record; 91 of the 91 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103 · cited 3×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodNumerical Recipes, The Art of Scientific Computing
Press, W. H., Flannery, B. P., Teukolsky, S. A., Vetterling, W. T., & Gould, H. (1987) · American Journal of Physics · doi:10.1119/1.14981 · Cited by 10,024
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868 · cited 2×
“The segmentation of images and generation of a 3D model can be done using available software tools such as MimicsTM [53], MIPAV (NIH, [54], ITK‐SNAP [55], Seg‐3D [56], TurtleSeg(www.”
MethodNumerical Recipes: The Art of Scientific Computing
Ziegel, E. (1987) · Technometrics · doi:10.1080/00401706.1987.10488304 · Cited by 6,702
Heart Disease and Stroke Statistics—2015 Update: A Report From the American Heart Association
Mozaffarian, D., Benjamin, E. J., Go, A. S., Arnett, D. K., Blaha, M. J., Cushman, M., de Ferranti, S., Després, J.-P., Fullerton, H. J., Howard, V. J., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000152 · Cited by 5,797
Tarver, T. (2014) · Journal of Consumer Health On the Internet · doi:10.1080/15398285.2014.902284 · Cited by 5,605
Aronszajn, N. (1950) · Transactions of the American Mathematical Society · doi:10.1090/s0002-9947-1950-0051437-7 · Cited by 5,380 · cited 6×
“The vector velocity field belongs to a reproducing kernel Hilbert space (RKHS) [83] denoted by .”
BackgroundMethodInfluentialPrincipal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Efficient variants of the ICP algorithm
Rusinkiewicz, S., & Levoy, M. (2002) · Proceedings Third International Conference on 3-D Digital Imaging and Modeling · doi:10.1109/im.2001.924423 · Cited by 3,945 · cited 1×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodMittal, R., & Iaccarino, G. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.061903.175743 · Cited by 3,472 · cited 6×
“The other popular method in the simulation of cardiac flows is the immersed boundary method (IBM) [106].”
MethodInfluentialSelf-citationNumerical Recipes 3rd Edition: The Art of Scientific Computing
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (2007) · Cambridge University Press eBooks · Cited by 3,328
Numerical analysis of blood flow in the heart
Peskin, C. S. (1977) · Journal of Computational Physics · doi:10.1016/0021-9991(77)90100-0 · Cited by 3,084 · cited 1×
“With the IBM approach, which are originally developed by Peskin for the very purpose of modeling cardiac hemodynamics [38, 39, 40, 41], the dynamic 3D lumen of the model can simply be immersed into a Cartesian volume domain to perform the hemodynamic simulation on a structured Cartesian grid.”
MethodFlow patterns around heart valves: A numerical method
Peskin, C. S. (1972) · Journal of Computational Physics · doi:10.1016/0021-9991(72)90065-4 · Cited by 3,047 · cited 1×
“With the IBM approach, which are originally developed by Peskin for the very purpose of modeling cardiac hemodynamics [38, 39, 40, 41], the dynamic 3D lumen of the model can simply be immersed into a Cartesian volume domain to perform the hemodynamic simulation on a structured Cartesian grid.”
MethodMoore's law: past, present and future
Schaller, R. R. (1997) · IEEE Spectrum · doi:10.1109/6.591665 · Cited by 1,914 · cited 1×
“One way to tip the scales in our favor is to counteract these unfavorable trends with ones that are favorable, and one trend that is significantly in our favor is the Moore’s Law [3], which refers to the trend in computing, enabled by increases in clock‐speed, concurrency, memory and memory bandwidth, that has continu…”
BackgroundComputing Large Deformation Metric Mappings via Geodesic Flows of Diffeomorphisms
Beg, M. F., Miller, M. I., Trouvé, A., & Younes, L. (2005) · International Journal of Computer Vision · doi:10.1023/b:visi.0000043755.93987.aa · Cited by 1,719 · cited 14×
“The cardiac lumen surfaces of interest here undergo large deformations, and here we employ a diffeomorphic registration algorithm known as Large Deformation Diffeomorphic Metric Mapping (LDDMM) [81, 82].”
MethodInfluentialSelf-citationMedical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Taylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208 · cited 6×
“An excellent example in this regard is the CFD‐based protocol for the assessment of the functional significance of coronary artery stenoses developed by HeartFlow [7], which recently been approved by FDA for clinical use.”
BackgroundMethodInfluentialMittal, R., Dong, H., Bozkurttas, M., Najjar, F. M., Vargas, A., & von Loebbecke, A. (2008) · Journal of Computational Physics · doi:10.1016/j.jcp.2008.01.028 · Cited by 1,186 · cited 9×
“10A), and the flow simulation is performed by solving the incompressible Navier‐Stokes equation using the immersed boundary method (IBM) [107].”
MethodInfluentialSelf-citationDiagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography
Min, J. K., Leipsic, J., Pencina, M. J., Berman, D. S., Koo, B.-K., van Mieghem, C., Erglis, A., Lin, F. Y., Dunning, A. M., Apruzzese, P., et al. (2012) · JAMA · doi:10.1001/2012.jama.11274 · Cited by 1,162
Multiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106 · cited 1×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodOn the relationships between local vortex identification schemes
CHAKRABORTY, P., BALACHANDAR, S., & ADRIAN, R. J. (2005) · Journal of Fluid Mechanics · doi:10.1017/s0022112005004726 · Cited by 923 · cited 2×
“Vortex structures are visualized using the λci‐criterion [110, 111] and colored by the magnitude of velocity.”
MethodSmith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898 · cited 1×
“Although the level of radiation exposure and the associated hazards are still debatable [47, 48, 49], this technology has a promising future with the development of fifth generation designs incorporating advanced technologies such as wide area detectors, myocardial perfusion imaging, dual energy and spectral imaging t…”
BackgroundOn the convergence of discrete approximations to the Navier-Stokes equations
Chorin, A. J. (1969) · Mathematics of Computation · doi:10.1090/s0025-5718-1969-0242393-5 · Cited by 787
A review of recent range image registration methods with accuracy evaluation
Salvi, J., Matabosch, C., Fofi, D., & Forest, J. (2007) · Image and Vision Computing · doi:10.1016/j.imavis.2006.05.012 · Cited by 597 · cited 1×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodAchenbach, S., Marwan, M., Ropers, D., Schepis, T., Pflederer, T., Anders, K., Kuettner, A., Daniel, W. G., Uder, M., & Lell, M. M. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp470 · Cited by 585 · cited 1×
“Several systems are now capable of whole heart isotemporal acquisitions over portions of a single heartbeat [44, 45, 46].”
BackgroundMedical Image Processing, Analysis and Visualization in clinical research
McAuliffe, M. J., Lalonde, F. M., McGarry, D., Gandler, W., Csaky, K., & Trus, B. L. (2002) · Proceedings 14th IEEE Symposium on Computer-Based Medical Systems. CBMS 2001 · doi:10.1109/cbms.2001.941749 · Cited by 512
Peskin, C. S., & McQueen, D. M. (1989) · Journal of Computational Physics · doi:10.1016/0021-9991(89)90213-1 · Cited by 485
Smith-Bindman, R. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1002530 · Cited by 443 · cited 1×
“Although the level of radiation exposure and the associated hazards are still debatable [47, 48, 49], this technology has a promising future with the development of fifth generation designs incorporating advanced technologies such as wide area detectors, myocardial perfusion imaging, dual energy and spectral imaging t…”
BackgroundOn the Metrics and Euler-Lagrange Equations of Computational Anatomy
Miller, M. I., Trouvé, A., & Younes, L. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.092101.125733 · Cited by 438 · cited 14×
“The cardiac lumen surfaces of interest here undergo large deformations, and here we employ a diffeomorphic registration algorithm known as Large Deformation Diffeomorphic Metric Mapping (LDDMM) [81, 82].”
MethodInfluentialSelf-citationThe Living Heart Project: A robust and integrative simulator for human heart function
Baillargeon, B., Rebelo, N., Fox, D. D., Taylor, R. L., & Kuhl, E. (2014) · European Journal of Mechanics - A/Solids · doi:10.1016/j.euromechsol.2014.04.001 · Cited by 370 · cited 2×
“Although in the initial model [32], the flow component is simplified with a lumped element type model, it is possible to perform fully coupled electromechanics and hemodynamic simulations.”
MethodLeft ventricular thrombus formation after acute myocardial infarction
Delewi, R., Zijlstra, F., & Piek, J. J. (2012) · Heart · doi:10.1136/heartjnl-2012-301962 · Cited by 364 · cited 4×
“While there are a number of groups that have employed different variants of the immersed boundary method to model cardiac flows [15, 26, 27, 28, 29, 58, 59, 80, 83, 84, 85, 86, 87, 88] we describe the solver and the particular approach that is used by our group.”
BackgroundMethodInfluentialMcInerney, T., & Terzopoulos, D. (1995) · Computerized Medical Imaging and Graphics · doi:10.1016/0895-6111(94)00040-9 · Cited by 358 · cited 2×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodMorphology of the Human Mitral Valve: II. The Valve Leaflets
RANGANATHAN, N., LAM, J. H. C., WIGLE, E. D., & SILVER, M. D. (1970) · Circulation · doi:10.1161/01.cir.41.3.459 · Cited by 351
Younes, L. (2010) · Applied Mathematical Sciences · doi:10.1007/978-3-642-12055-8 · Cited by 338 · cited 1×
“The algorithm used to minimize this cost function is described in detail in [84].”
MethodSelf-citationObstruction of mechanical heart valve prostheses: Clinical aspects and surgical management
Deviri, E., Sareli, P., Wisenbaugh, T., & Cronje, S. L. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80178-0 · Cited by 333 · cited 1×
“In addition to HOCM, cardiac hemodynamic models could assist with the surgical planning of heart transplants, ventricular assist devices (VAD) [13], implantation of prosthetic valves [14], valve repair (e.”
BackgroundImmersed finite element method and its applications to biological systems
Liu, W. K., Liu, Y., Farrell, D., Zhang, L., Wang, X. S., Fukui, Y., Patankar, N., Zhang, Y., Bajaj, C., Lee, J., et al. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.05.049 · Cited by 309
Hsu, M.-C., Kamensky, D., Bazilevs, Y., Sacks, M. S., & Hughes, T. J. R. (2014) · Computational Mechanics · doi:10.1007/s00466-014-1059-4 · Cited by 304 · cited 1×
“[95] on the FEM FSI analysis of bio‐ prosthetic valve is also notable.”
MethodSymposium on geometry processing
(2006) · Computers & Graphics · doi:10.1016/j.cag.2006.01.014 · Cited by 264
Seo, J.-H., & Mittal, R. (2010) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.10.017 · Cited by 262 · cited 1×
“generation and propagation of blood flow‐induced sounds using a hybrid approach that employs the incompressible Navier‐Stokes and the linearized perturbed compressible equations (LPCE) [118, 119].”
MethodSelf-citationPlatelet thrombin receptor antagonism and atherothrombosis
Angiolillo, D. J., Capodanno, D., & Goto, S. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp504 · Cited by 251 · cited 1×
“Thrombus formation is the result of a complex biochemical process that involves both the infarcted myocardium and the blood flow [113].”
BackgroundYounes, L. (2019) · Applied Mathematical Sciences · doi:10.1007/978-3-662-58496-5 · Cited by 242
Self-citationWatanabe, H., Sugiura, S., Kafuku, H., & Hisada, T. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.035840 · Cited by 226 · cited 3×
“The conventional approach to CFD modeling of flow in complex geometries employs finite‐volume [21, 68, 99, 100, 101] or finite‐element method (FEM) [7, 8, 9, 10, 102, 103, 104] with unstructured, body‐conformal grids and these methods have been successfully applied to vascular flow simulations.”
MethodProceedings of the 2004 IEEE Computer Society Conference on Computer Vision and Pattern Recognition
(2004) · Proceedings of the 2004 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 2004. CVPR 2004. · doi:10.1109/cvpr.2004.1314997 · Cited by 210
GRIFFITH, B. E., LUO, X., McQUEEN, D. M., & PESKIN, C. S. (2009) · International Journal of Applied Mechanics · doi:10.1142/s1758825109000113 · Cited by 194 · cited 3×
“While there are a number of groups that have employed different variants of the immersed boundary method to model cardiac flows [15, 26, 27, 28, 29, 58, 59, 80, 83, 84, 85, 86, 87, 88] we describe the solver and the particular approach that is used by our group.”
BackgroundMethodImage-based large-eddy simulation in a realistic left heart
Chnafa, C., Mendez, S., & Nicoud, F. (2014) · Computers & Fluids · doi:10.1016/j.compfluid.2014.01.030 · Cited by 193 · cited 1×
“Thus, there is a clear need to create an efficient and automated pipeline for generating CFD‐ready models from cardiac imaging and a number of groups are working on this using a variety of methods [62, 63, 64, 65, 66, 67, 68, 69, 70].”
MethodA modular numerical method for implicit 0D/3D coupling in cardiovascular finite element simulations
Esmaily Moghadam, M., Vignon-Clementel, I. E., Figliola, R., & Marsden, A. L. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.07.035 · Cited by 190
Patient-specific models of cardiac biomechanics
Krishnamurthy, A., Villongco, C. T., Chuang, J., Frank, L. R., Nigam, V., Belezzuoli, E., Stark, P., Krummen, D. E., Narayan, S., Omens, J. H., et al. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.09.015 · Cited by 181
Surgical management of hypertrophic obstructive cardiomyopathy
Heric, B., Lytle, B. W., Miller, D. P., Rosenkranz, E. R., Level, H. M., & Cosgrove, D. M. (1995) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(05)80026-1 · Cited by 180 · cited 6×
“Take for example the surgical management of hypertrophic obstructive cardiomyopathy (HOCM) [11], a leading cause of sudden cardiac death in otherwise healthy individuals, and a condition that causes significant morbidity in patients with advanced forms of the disease.”
BackgroundInfluentialSchenkel, T., Malve, M., Reik, M., Markl, M., Jung, B., & Oertel, H. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9627-4 · Cited by 168 · cited 1×
“conventional approach to CFD modeling of flow in complex geometries employs finite‐volume [21, 68, 99, 100, 101] or finite‐element method (FEM) [7, 8, 9, 10, 102, 103, 104] with unstructured, body‐conformal grids and these”
MethodGlaunes, J., Trouve, A., & Younes, L. (2004) · Proceedings of the 2004 IEEE Computer Society Conference on Computer Vision and Pattern Recognition, 2004. CVPR 2004. · doi:10.1109/cvpr.2004.1315234 · Cited by 165
Self-citationChen, M. Y., Shanbhag, S. M., & Arai, A. E. (2013) · Radiology · doi:10.1148/radiol.13122621 · Cited by 164 · cited 1×
“Acquisition times are rapid, varying from 5‐10 seconds for 64 detector systems to as little as 275 msec for 320 detector systems, and CT images can be acquired with effective radiation doses often less than background radiation from environmental sources [43].”
BackgroundFluid-Structure Coupled CFD Simulation of the Left Ventricular Flow During Filling Phase
Cheng, Y., Oertel, H., & Schenkel, T. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-4388-9 · Cited by 153 · cited 1×
“conventional approach to CFD modeling of flow in complex geometries employs finite‐volume [21, 68, 99, 100, 101] or finite‐element method (FEM) [7, 8, 9, 10, 102, 103, 104] with unstructured, body‐conformal grids and these”
MethodActive Learning for Interactive 3D Image Segmentation
Top, A., Hamarneh, G., & Rafeef Abugharbieh, A. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23626-6_74 · Cited by 151 · cited 1×
“org) [57, 58], 3D‐Doctor [59], MITK [60] and GIMIAS [61], many of which are open‐ source tools.”
BackgroundFluid Mechanics of Heart Valves and Their Replacements
Sotiropoulos, F., Le, T. B., & Gilmanov, A. (2015) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122414-034314 · Cited by 147 · cited 1×
“The current efforts on the patient‐specific simulation of cardiac valves by various research groups are summarized in two recent review articles [96] and [97].”
BackgroundDirect numerical simulation of the pulsatile flow through an aortic bileaflet mechanical heart valve
Tullio, M. D. D., Cristallo, A., Balaras, E., et al. (2009) · Journal of Fluid Mechanics · doi:10.1017/s0022112008005156 · Cited by 145 · cited 2×
“(A) Comparison of total stress exerted on the blood cells for through a natural (left) and bileaflet mechanical (right) aortic valve obtained by FSI modeling [91, 92] (Image provided by Dr.”
BackgroundMethodToward patient-specific simulations of cardiac valves: State-of-the-art and future directions
Votta, E., Le, T. B., Stevanella, M., Fusini, L., Caiani, E. G., Redaelli, A. C. L., & Sotiropoulos, F. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.10.026 · Cited by 145 · cited 1×
“The current efforts on the patient‐specific simulation of cardiac valves by various research groups are summarized in two recent review articles [96] and [97].”
BackgroundNeeves, K. B., Illing, D. A. R., & Diamond, S. L. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2009.12.4275 · Cited by 134 · cited 1×
“16 In our recent study [114], we performed the simulation of LVT formation in the canonical model of infarcted LVs by solving the incompressible Navier‐Stokes equation and a total of 21 coupled CDR equations describing the coagulation cascade [115], the conversion of fibrinogen into fibrin [116], platelet activation a…”
MethodFox, M., Mealing, S., Anderson, R., Dean, J. W., Stein, K., Price, A., & Taylor, R. S. (2007) · Health Technology Assessment · doi:10.3310/hta11470 · Cited by 134 · cited 1×
“For example, cardiac resynchronization therapy with biventricular pacemakers aimed at improving cardiovascular hemodynamics, is a costly therapy that results in approximately 11‐46% of the recipients deriving no benefit [2].”
BackgroundSaber, N. R., Wood, N. B., Gosman, A. D., Merrifield, R. D., Yang, G., Charrier, C. L., Gatehouse, P. D., & Firmin, D. N. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1533073 · Cited by 133 · cited 2×
“Cardiac hemodynamic models that incorporate X‐ ray computed tomography (CT), CMR or Echo information could provide information regarding flow patterns, blood residence time and flow stasis [17, 18, 19, 20, 21, 22, 23, 24, 25] that far exceed what is available from structural imaging alone, and in doing so, enhance the…”
BackgroundMethodWeininger, M., Schoepf, U. J., Ramachandra, A., Fink, C., Rowe, G. W., Costello, P., & Henzler, T. (2010) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.11.022 · Cited by 130 · cited 1×
“Although the level of radiation exposure and the associated hazards are still debatable [47, 48, 49], this technology has a promising future with the development of fifth generation designs incorporating advanced technologies such as wide area detectors, myocardial perfusion imaging, dual energy and spectral imaging t…”
BackgroundMihalef, V., Ionasec, R. I., Sharma, P. K., Georgescu, B., Voigt, I., Suehling, M., & Comaniciu, D. (2011) · Interface Focus · doi:10.1098/rsfs.2010.0036 · Cited by 123
A three-dimensional computational method for blood flow in the heart. II. contractile fibers
McQueen, D. M., & Peskin, C. S. (1989) · Journal of Computational Physics · doi:10.1016/0021-9991(89)90050-8 · Cited by 121
Effect of the mitral valve on diastolic flow patterns
Seo, J.-H., Vedula, V., Abraham, T. P., Lardo, A. C., Dawoud, F., Luo, H., & Mittal, R. (2014) · Physics of Fluids · doi:10.1063/1.4904094 · Cited by 117 · cited 5×
“For instance, our recent study [87] has shown that the presence of the mitral valve (MV) significantly affects the flow and its propagation into the left ventricle.”
BackgroundMethodResultInfluentialSelf-citationCardiac resynchronization therapy (CRT): Clinical trials, guidelines, and target populations
Linde, C. M., Ellenbogen, K. A., & McAlister, F. A. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.04.026 · Cited by 116 · cited 3×
“In addition to HOCM, cardiac hemodynamic models could assist with the surgical planning of heart transplants, ventricular assist devices (VAD) [13], implantation of prosthetic valves [14], valve repair (e.g. mitral clip surgery) [15] and cardiac‐resynchronization therapy (CRT) [16].”
BackgroundLe, T. B., & Sotiropoulos, F. (2012) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.08.036 · Cited by 106 · cited 1×
“Le and Sotiropoulos performed a FSI simulation of prosthetic aortic valve in the realistic aorta coupled with LV hemodynamics [94].”
MethodKung, E. O., Baretta, A., Baker, C., Arbia, G., Biglino, G., Corsini, C. A., Schievano, S., Vignon-Clementel, I. E., Dubini, G., Pennati, G., et al. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.10.023 · Cited by 96
Effect of diastolic flow patterns on the function of the left ventricle
Seo, J.-H., & Mittal, R. (2013) · Physics of Fluids · doi:10.1063/1.4819067 · Cited by 93 · cited 2×
“Cardiac hemodynamic models that incorporate X‐ ray computed tomography (CT), CMR or Echo information could provide information regarding flow patterns, blood residence time and flow stasis [17, 18, 19, 20, 21, 22, 23, 24, 25] that far exceed what is available from structural imaging alone, and in doing so, enhance the…”
BackgroundMethodSelf-citationA comparative study of state-of-the-art evolutionary image registration methods for 3D modeling
Santamaría, J., Cordón, Ó., & Damas, S. (2011) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2011.05.006 · Cited by 92 · cited 1×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodProceedings Third International Conference on 3-D Digital Imaging and Modeling
(2001) · International Conference on 3-D Digital Imaging and Modeling (3DIM) · doi:10.1109/im.2001.924375 · Cited by 89
Comparative numerical study on left ventricular fluid dynamics after dilated cardiomyopathy
Mangual, J. O., Kraigher‐Krainer, E., Luca, A. D., Toncelli, L., Shah, A. M., Solomon, S. D., Galanti, G., Domenichini, F., & Pedrizzetti, G. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.04.012 · Cited by 88 · cited 1×
“Cardiac hemodynamic models that incorporate X‐ ray computed tomography (CT), CMR or Echo information could provide information regarding flow patterns, blood residence time and flow stasis [17, 18, 19, 20, 21, 22, 23, 24, 25] that far exceed what is available from structural imaging alone, and in doing so, enhance the…”
BackgroundAn Image Processing Approach to Surface Matching
Nathan Litke, B., Droske, M., Rumpf, M., & Schröder, P. (2005) · CaltechAUTHORS (California Institute of Technology) · doi:10.2312/sgp/sgp05/207-216 · Cited by 68
Matching of 3D surfaces and their intensities
Akça, D. (2006) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2006.06.001 · Cited by 66 · cited 1×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodTang, D., Yang, C., Geva, T., & del Nido, P. J. (2010) · Progress in Pediatric Cardiology · doi:10.1016/j.ppedcard.2010.09.007 · Cited by 61
Multi-feature matching algorithm for free-form 3D surface registration
Schütz, C., Jost, T., & Hügli, H. (2002) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr.1998.711852 · Cited by 57 · cited 1×
“The mapping can in‐principle be accomplished by a variety of surface matching algorithms [62, 72, 73, 74, 75, 76, 77] but methods such as Iterative Closest Point (ICP) [78] and elastic deformation algorithms [79, 80] are not diffeomorphic and are only suitable for”
MethodComputational modeling and analysis of intracardiac flows in simple models of the left ventricle
Zheng, X., Seo, J. H., Vedula, V., Abraham, T. P., & Mittal, R. (2012) · European Journal of Mechanics - B/Fluids · doi:10.1016/j.euromechflu.2012.03.002 · Cited by 57 · cited 2×
“Cardiac hemodynamic models that incorporate X‐ ray computed tomography (CT), CMR or Echo information could provide information regarding flow patterns, blood residence time and flow stasis [17, 18, 19, 20, 21, 22, 23, 24, 25] that far exceed what is available from structural imaging alone, and in doing so, enhance the…”
BackgroundMethodSelf-citationTop, A., Hamarneh, G., & Abugharbieh, R. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-18421-5_20 · Cited by 57 · cited 3×
“While there are a number of groups that have employed different variants of the immersed boundary method to model cardiac flows [15, 26, 27, 28, 29, 58, 59, 80, 83, 84, 85, 86, 87, 88] we describe the solver and the particular approach that is used by our group.”
BackgroundMethodEstimating myocardial motion by 4D image warping
Sundar, H., Litt, H. I., & Shen, D. G. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2009.04.022 · Cited by 54 · cited 1×
“Thus, there is a clear need to create an efficient and automated pipeline for generating CFD‐ready models from cardiac imaging and a number of groups are working on this using a variety of methods [62, 63, 64, 65, 66, 67, 68, 69, 70].”
MethodLau, K. D., & Figueroa, C. A. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-014-0645-x · Cited by 53 · cited 1×
“The simulations of blood flow in these larger vessels are becoming more reliable by coupling with lumped elements models [4, 5] of the circulatory system and the smaller vessels.”
Method2012 IEEE International Conference on Cluster Computing
(2012) · doi:10.1109/cluster20797.2012 · Cited by 52
Temporal Enhancement of 3D Echocardiography by Frame Reordering
Perrin, D. P., Vasilyev, N. V., Marx, G. R., & del Nido, P. J. (2012) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2011.10.006 · Cited by 46 · cited 1×
“While 2D echocardiography provides higher temporal resolution (30‐100 fps), current 3D volumetric ultrasound sequences are limited to about 20 volumes per second although newer methods to increase this frame rate are being devised [42].”
Registration of 4D Time-Series of Cardiac Images with Multichannel Diffeomorphic Demons
Peyrat, J., Delingette, H., Maxime Sermesant, B., Xavier Pennec, B., Xu, C., & Ayache, N. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85990-1_117 · Cited by 42 · cited 1×
“Thus, there is a clear need to create an efficient and automated pipeline for generating CFD‐ready models from cardiac imaging and a number of groups are working on this using a variety of methods [62, 63, 64, 65, 66, 67, 68, 69, 70].”
MethodDefontaine, A., Hernandez, A. I., & Carrault, G. (2005) · Lecture notes in computer science · doi:10.1007/b136980 · Cited by 42
RV functional imaging: 3-D echo-derived dynamic geometry and flow field simulations
Pasipoularides, A. D., Shu, M., Womack, M. S., Shah, A. S., von Ramm, O. T., & Glower, D. D. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00577.2002 · Cited by 41 · cited 3×
“The conventional approach to CFD modeling of flow in complex geometries employs finite‐volume [21, 68, 99, 100, 101] or finite‐element method (FEM) [7, 8, 9, 10, 102, 103, 104] with unstructured, body‐conformal grids and these methods have been successfully applied to vascular flow simulations.”
MethodCámara, Ó., Young, A. A., Maxime Sermesant, B., Rhode, K., Pop, M., & Konukoğlu, E. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-28326-0 · Cited by 37
Computational prediction of mechanical hemolysis in aortic valved prostheses
de Tullio, M. D., Nam, J., Pascazio, G., Balaras, E., & Verzicco, R. (2012) · European Journal of Mechanics - B/Fluids · doi:10.1016/j.euromechflu.2012.01.009 · Cited by 37 · cited 2×
“(A) Comparison of total stress exerted on the blood cells for through a natural (left) and bileaflet mechanical (right) aortic valve obtained by FSI modeling [91, 92] (Image provided by Dr.”
BackgroundMethodComputational Cardiology: The Heart of the Matter
Trayanova, N. A. (2012) · ISRN Cardiology · doi:10.5402/2012/269680 · Cited by 36 · cited 1×
“The other approach is to employ heart function models that incorporate biophysical modeling of cardiac electromechanics [30, 31].”
MethodEffect of ventricle motion on the dynamic behaviour of chorded mitral valves
Watton, P. N., Luo, X., Yin, M., Bernacca, G. M., & Wheatley, D. J. (2007) · Journal of Fluids and Structures · doi:10.1016/j.jfluidstructs.2007.06.004 · Cited by 34
From medical images to flow computations without user‐generated meshes
Dillard, S., Mousel, J., Shrestha, L., Raghavan, M. L., & Vigmostad, S. C. (2014) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2644 · Cited by 32
Doppler Ultrasound Simulation Model for Pulsatile Flow with Nonaxial Components
Oung, H., & Forsberg, F. (1996) · Ultrasonic Imaging · doi:10.1177/016173469601800301 · Cited by 25 · cited 1×
“This is done by the Lagrangian particle tracking of virtual red blood cell (RBC) and applying sound wave scattering theory [120].”
MethodChoi, Y. J., Constantino, J. L., Vedula, V., Trayanova, N. A., & Mittal, R. (2015) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2015.00140 · Cited by 24 · cited 3×
“Another recent example of a one‐way coupled model is that of Choi et al. (2015) [35] which coupled a detailed multiscale model for cardiac electromechanics with a Navier‐Stokes model for the hemodynamics, and used it to examine the effect of heart failure and dyssynchony on LV hemodynamics.”
BackgroundMethodSelf-citationPatient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Vadakkumpadan, F., Arevalo, H., & Trayanova, N. A. (2013) · Journal of Visualized Experiments · doi:10.3791/50125 · Cited by 14 · cited 6×
“Recent advances in the multi‐scale electro‐mechanical modeling [33] of myocardial tissues and advanced medical imaging such as a diffusion tensor MRI [34] which captures the fiber orientations, would enable such fully coupled simulation of cardiac motion and hemodynamics [35].”
BackgroundInfluential
Cited by
Kadem, M., Garber, L., Abdelkhalek, M., Al-Khazraji, B. K., & Keshavarz-Motamed, Z. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2022.3142058 · Cited by 89
Nguyen, T. D., Kadri, O. E., & Voronov, R. S. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.529365 · Cited by 19
“…and processing (Weese et al., 2013; Lamata et al., 2014; Wang et al., 2015; Watson et al., 2018), hemodynamic flow simulations (Tang et al., 2010; Mittal et al., 2016; Quarteroni et al., 2017; Zhong et al., 2018); electrical conduction and stimulation modeling (Trayanova, 2011, 2012; Tobon-Gomez…”
BackgroundMethod
Metadata
- Authors
- Mittal, R., Seo, J. H., Vedula, V., Choi, Y. J., Liu, H., Huang, H. H., Jain, S., Younes, L., Abraham, T., & George, R. T.
- Venue
- Journal of Computational Physics
- Publisher
- Elsevier BV
- Published
- 2016-01
- Volume
- 305
- Pages
- 1065-1082
- ISSN
- 0021-9991 (ISSN-L)
- OpenAlex
- W2180795105
- Cited by
- 194
- References
- 91
- FWCI
- 11.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.