Generalized framework for stimulus artifact removal.
Abstract
Stimulation is extensively used in neuroscience research in diverse fields ranging from cognitive to clinical. Studying the effect of electrical and magnetic stimulation on neuronal activity is complicated by large stimulation-derived artifacts on the recording electrodes, which mask the spiking activity. Multiple studies have suggested a variety of solutions for the removal of artifacts and were typically directed at specific stimulation setups. In this study we introduce a generalized framework for stimulus artifacts removal, the Stimulus Artifact Removal Graphical Environment (SARGE). The framework provides an encapsulated environment for a multi-stage removal process, starting from the stimulus pulse detection, through estimation of the artifacts and their removal, and finally to signal reconstruction and the assessment of removal quality. The framework provides the user with subjective graphical and objective quantitative tools for assessing the resulting signal, and the ability to adjust the process to optimize the results. This extendable publicly available framework supports different types of stimulation, stimulation patterns and shapes, and a variety of artifact estimation methods. We exemplify the removal of artifacts generated by electrical micro- and macro-stimulation and magnetic stimulation and different stimulation protocols. The use of different estimation methods, such as averaging and function fitting is demonstrated, and the differences between them are discussed. Finally, the quality of removal is assessed and validated using quantitative measures and combined experimental-simulation studies. The framework marks a shift from "algorithm" and "data" centric approach to a "workflow" centric approach, thus introducing an innovative concept to the artifact removal process.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The blanking technique and digital signal processing have been used to cancel the artifact.
“The blanking technique and digital signal processing (Erez et al., 2010) have been used to cancel the artifact (Olsson et al., 2005; Venkatraman et al., 2009; Kent and Grill, 2011; Myers et al., 2011; Zoladz et al., 2012; Wei-Ming et al., 2013; Yi et al., 2013; Bozorgzadeh et al., 2014; Elyahoodayan et al., 2019).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Erez et al., 2010
Cites
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024 · see citing works
Stimulation of the Subthalamic Nucleus Changes the Firing Pattern of Pallidal Neurons
Hashimoto, T., Elder, C. M., Okun, M., Patrick, S. K., & Vitek, J. (2003) · Journal of Neuroscience · doi:10.1523/jneurosci.23-05-01916.2003 · Cited by 925 · see citing works
Acute and Long-Term Effects of Subthalamic Nucleus Stimulation in Parkinson's Disease
Benabid, A., Pollak, P., Gross, C. E., Hoffmann, D., Benazzouz, A., Gao, D. M., Laurent, A., Gentil, M., & Perret, J. E. (1995) · Stereotactic and Functional Neurosurgery · doi:10.1159/000098600 · Cited by 531 · see citing works
Microstimulation-Induced Inhibition of Neuronal Firing in Human Globus Pallidus
Dostrovsky, J. O., Levy, R., Wu, J. P., Hutchison, W. D., Tasker, R. R., & Lozano, A. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.570 · Cited by 470 · see citing works
Controlling Bursting in Cortical Cultures with Closed-Loop Multi-Electrode Stimulation
Wagenaar, D. A., Madhavan, R., Pine, J., & Potter, S. M. (2005) · Journal of Neuroscience · doi:10.1523/jneurosci.4209-04.2005 · Cited by 454 · see citing works
Deep Brain Stimulation for Neurologic and Neuropsychiatric Disorders
Wichmann, T., & DeLong, M. R. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.022 · Cited by 331 · see citing works
Effect of transcranial magnetic stimulation on single‐unit activity in the cat primary visual cortex
Moliadze, V., Zhao, Y., Eysel, U. T., & Funke, K. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.050153 · Cited by 248 · see citing works
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 224 · see citing works
A template subtraction method for stimulus artifact removal in high-frequency deep brain stimulation
Hashimoto, T., Elder, C. M., & Vitek, J. L. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00491-5 · Cited by 195 · see citing works
Bar‐Gad, I., Elias, S., Vaadia, E., & Bergman, H. (2004) · Journal of Neuroscience · doi:10.1523/jneurosci.1691-04.2004 · Cited by 160 · see citing works
Self-citationA novel stimulus artifact removal technique for high-rate electrical stimulation
Heffer, L. F., & Fallon, J. B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.01.023 · Cited by 121 · see citing works
Strafella, A. P., van der Werf, Y. D., & Sadikot, A. F. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03669.x · Cited by 96 · see citing works
Stimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95 · see citing works
Stimulus artifact removal using a software-based two-stage peak detection algorithm
O'Keeffe, D. T., Lyons, G. M., Donnelly, A., & Byrne, C. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00407-1 · Cited by 90 · see citing works
Deep Brain Stimulation Does Not Silence Neurons in Subthalamic Nucleus in Parkinson's Patients
Carlson, J. D., Cleary, D. R., Cetas, J. S., Heinricher, M. M., & Burchiel, K. J. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00363.2009 · Cited by 82 · see citing works
A digital averaging method for removal of stimulus artifacts in neurophysiologic experiments
Wichmann, T. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00190-4 · Cited by 78 · see citing works
Moran, A., & Bar‐Gad, I. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.10.024 · Cited by 60 · see citing works
Self-citationMontgomery, E. B., Gale, J. T., & He, H. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.017 · Cited by 48 · see citing works
Erez, Y., Czitron, H., McCairn, K. W., et al. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.0401-09.2009 · Cited by 47 · see citing works
Self-citationHarding, G. W. (1991) · Computers and Biomedical Research · doi:10.1016/0010-4809(91)90029-v · Cited by 28 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Thalamus Modulates Consciousness via Layer-Specific Control of Cortex
Redinbaugh, M. J., Phillips, J. M., Kambi, N. A., Mohanta, S., Andryk, S., Dooley, G. L., Afrasiabi, M., Raz, A., & Saalmann, Y. B. (2020) · Neuron · doi:10.1016/j.neuron.2020.01.005 · Cited by 391 · see citing works
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125 · see citing works
Qiu, S., Feng, J., Xu, R., Xu, J., Wang, K., He, F., Qi, H., Zhao, X., Zhou, P., Zhang, L., et al. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2407834 · Cited by 39 · see citing works
Advances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21 · see citing works
- Authors
- Erez, Y., Tischler, H., Moran, A., & Bar-Gad, I.
- Affiliations
- Bar-Ilan University (IL)
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 191
- Issue
- 1
- Pages
- 45-59
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2036906125
- Cited by
- 79
- References
- 21
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 9 · 2023: 7 · 2022: 2 · 2021: 8 · 2020: 7 · 2019: 2 · 2018: 5 · 2017: 3 · 2016: 5 · 2015: 3 · 2014: 3 · 2013: 2 · 2012: 9
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Israel Science Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- electrical stimulation, magnetic stimulation, signal reconstruction, signal quality assessment, averaging, function fitting, neural recording
- MeSH terms
- Animals, Computer Simulation, Electric Stimulation, Electrophysiology, Macaca fascicularis, Male, Models, Neurological, Signal Processing, Computer-Assisted, Software, Artifacts, Transcranial Magnetic Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review