Cited by 118Mangiferin and Mango ExtractsAnalytical Methods in PharmaceuticalsTraditional Chinese Medicine Analysis

Determination of mangiferin in rat plasma by liquid-liquid extraction with UPLC-MS/MS

Han, Dandan, Chen, Chengjun, Zhang, Cong, Zhang, Yu, Tang, Xing·2010·Journal of Pharmaceutical and Biomedical Analysis

Abstract

An ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method employing electrospray ionization (ESI) has been developed for the determination of mangiferin in rat plasma using diphenhydramine as the internal standard (IS). Liquid-liquid extraction (LLE) was used for sample preparation and the analysis was achieved with gradient elution on C(18) reversed phase column. The method was validated over the concentration range 0.02-5.0 microg/mL for oral administration and 0.4-100 microg/mL for intravenous administration. The intra-day and inter-day precision of mangiferin expressed as RSD<15% and the accuracy (RE) did not exceed 15%. This validated method is a novel technique for sample preparation and quantitation, which was successfully applied to estimate the bioavailability of mangiferin.

Integrity signals

Registry

Crossref · 10.1016/j.jpba.2009.07.021

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Han, D., Chen, C., Zhang, C., Zhang, Y., & Tang, X.
Affiliations
Shenyang Pharmaceutical University (CN)
Corresponding author
Tang, Xing
Venue
Journal of Pharmaceutical and Biomedical Analysis
Publisher
Elsevier BV
Published
2010-01
Volume
51
Issue
1
Pages
260-263
ISSN
0731-7085 (ISSN-L)
OpenAlex
W2040331070
Cited by
118
References
11
Citations by year
2026: 5 · 2025: 13 · 2024: 2 · 2023: 14 · 2022: 8 · 2021: 7 · 2020: 9 · 2019: 12 · 2018: 6 · 2017: 1 · 2016: 11 · 2015: 5 · 2014: 3 · 2013: 5 · 2012: 4
FWCI
12.57
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Pharmaceutical and Biomedical Analysis (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Complementary and alternative medicine › Mangiferin and Mango Extracts
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Health Sciences › Medicine › Complementary and alternative medicine › Traditional Chinese Medicine Analysis
Keywords
mangiferin, rat plasma, bioavailability, liquid-liquid extraction, UPLC-MS/MS, sample preparation, method validation, pharmacokinetics
MeSH terms
Administration, Oral, Animals, Biological Availability, Chromatography, High Pressure Liquid, Diphenhydramine, Dose-Response Relationship, Drug, Injections, Intravenous, Male, Rats, Wistar, Spectrometry, Mass, Electrospray Ionization, Xanthones, Rats, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review