Top-down analysis of immunoglobulin G isotypes 1 and 2 with electron transfer dissociation on a high-field Orbitrap mass spectrometer
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The increasing importance of immunoglobulins G (IgGs) as biotherapeutics calls for improved structural characterization methods designed for these large (~150 kDa) macromolecules. Analysis workflows have to be rapid, robust, and require minimal sample preparation. In a previous work we showed the potential of Orbitrap Fourier transform mass spectrometry (FTMS) combined with electron transfer dissociation (ETD) for the top-down investigation of an intact IgG1, resulting in ~30% sequence coverage. Here, we describe a top-down analysis of two IgGs1 (adalimumab and trastuzumab) and one IgG2 (panitumumab) performed with ETD on a mass spectrometer equipped with a high-field Orbitrap mass analyzer. For the IgGs1, sequence coverage comparable to the previous results was achieved in a two-fold reduced number of summed transients, which corresponds, taken together with the significantly increased spectra acquisition rate, to ~six-fold improvement in analysis time. Furthermore, we studied the influence of ion-ion interaction times on ETD product ions for IgGs1, and the differences in fragmentation behavior between IgGs1 and IgG2, which present structural differences. Overall, these results reinforce the hypothesis that gas phase dissociation using both energy threshold-based and radical-driven ion activations is directed to specific regions of the polypeptide chains mostly by the location of disulfide bonds. Significance of the study Compared with our previous report, the results presented herein demonstrate the power of technological advances of the next generation Orbitrap™ platform, including the use of a high-field compact (i.e., D20) Orbitrap mass analyzer, and a dedicated manipulation strategy for large protein ions (via their trapping in the HCD collision cell along with reduction of the pressure in the cell). Notably, these important developments became recently commercially available in the top-end Orbitrap platforms under the name of “Protein Mode”. Furthermore, we continued exploring the advantages offered by the summation (averaging) of transients (time-domain data) for improving the signal-to-noise ratio of top-down mass spectra. Finally, for the first time we report the application of the hybrid ion activation technique that combines electron transfer dissociation and higher energy collisional dissociation, known as EThcD, on intact monoclonal antibodies. Under these specific instrumental parameters, EThcD produces a partially complementary fragmentation pattern compared to ETD, increasing the overall sequence coverage especially at the protein termini.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
IgG Subclasses and Allotypes: From Structure to Effector Functions
Vidarsson, G., Dekkers, G., & Rispens, T. (2014) · Frontiers in Immunology · doi:10.3389/fimmu.2014.00520 · Cited by 2,667
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370 · cited 1×
“[17] Electron capture dissociation (ECD)[18, 19] and electron transfer dissociation (ETD)[20] of whole proteins usually generate larger sequence coverage than slow-heating activation methods (such as collision-induced dissociation, CID).”
Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic Process
Zubarev, R. A., Kelleher, N. L., & McLafferty, F. W. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973478k · Cited by 1,881
Biopharmaceutical benchmarks 2014
Walsh, G. (2014) · Nature Biotechnology · doi:10.1038/nbt.3040 · Cited by 1,008
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Self-citationMichalski, A., Damoc, E., Lange, O., Denisov, E., Nolting, D., Müller, M., Viner, R., Schwartz, J., Remes, P., Belford, M., et al. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.013698 · Cited by 373 · cited 3×
“Here we investigated the potential of ETD implemented on a high-field compact Orbitrap FTMS, namely the Orbitrap Elite,[35] for faster top-down characterization of three therapeutic mAbs: adalimumab and trastuzumab (both of the IgG1 subclass), and the IgG2 panitumumab.”
Self-citationComplete Protein Characterization Using Top-Down Mass Spectrometry and Ultraviolet Photodissociation
Shaw, J. B., Li, W., Holden, D. D., Zhang, Y., Griep-Raming, J., Fellers, R. T., Early, B. P., Thomas, P. M., Kelleher, N. L., & Brodbelt, J. S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4029654 · Cited by 371 · cited 1×
“, ultraviolet photodissociation.[51] Furthermore, improved sequence coverage is achievable by combining ETD experimental data acquired with high HCD gas pressure (i.”
ProSight Lite: Graphical software to analyze top‐down mass spectrometry data
Fellers, R. T., Greer, J. B., Early, B. P., Yu, X., LeDuc, R. D., Kelleher, N. L., & Thomas, P. M. (2015) · PROTEOMICS · doi:10.1002/pmic.201400313 · Cited by 247 · cited 1×
“The graphical fragmentation maps reported herein were realized using either ProSightPC or ProSight Lite software.[47]”
Deconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170 · cited 1×
“14 developed at University of California San Diego, CA, USA).[46] A comparison between the results produced by MS-Deconv/MS-Align+ and by Xtract/ProSight PC is presented in Figure S2, Supporting Information.”
ResultSelf-citationGe, Y., Rybakova, I. N., Xu, Q., & Moss, R. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813369106 · Cited by 154 · cited 1×
“[22, 23] Fourier transform ion cyclotron resonance (FT-ICR) MS provides the highest resolution and can be hyphenated with ECD, making it the technique of choice for earlier TD MS experiments.[24-26] Notably, Mao et al.”
Evaluation of the Compact High-Field Orbitrap for Top-Down Proteomics of Human Cells
Ahlf, D. R., Compton, P. D., Tran, J. C., Early, B. P., Thomas, P. M., & Kelleher, N. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3004216 · Cited by 89 · cited 1×
“7 reversed phase liquid chromatography (LC) prior to electrospray ionization (ESI) became possible routinely.[32, 33] We have previously described the use of ETD with a high-resolution qTOF MS reporting the overall sequence coverage of 21% for mouse IgG1 and 15% for human IgG1 which provided structural information on…”
Zheng, Y., Fornelli, L., Compton, P. D., Sharma, S., Canterbury, J., Mullen, C., Zabrouskov, V., Fellers, R. T., Thomas, P. M., Licht, J. D., et al. (2016) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m115.053819 · Cited by 73 · cited 4×
“Finally, IgG TD MS was performed under the optimized conditions with a two-stage ion activation method, a combination of ETD and higher-energy collision dissociation (HCD)[40] termed EThcD,[41] which has been recently applied to TD MS experiments, demonstrating sequence complementarity with ETD.[42, 43]”
InfluentialSelf-citationValeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Cited by
Recent advances in mass spectrometry based clinical proteomics: applications to cancer research
Macklin, A., Khan, S., & Kislinger, T. (2020) · Clinical Proteomics · doi:10.1186/s12014-020-09283-w · Cited by 317
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Fornelli, L., Srzentić, K., Huguet, R., Mullen, C., Sharma, S., Zabrouskov, V., Fellers, R. T., Durbin, K. R., Compton, P. D., & Kelleher, N. L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00984 · Cited by 150
Self-citationProton Transfer Charge Reduction Enables High-Throughput Top-Down Analysis of Large Proteoforms
Huguet, R., Mullen, C., Srzentić, K., Greer, J. B., Fellers, R. T., Zabrouskov, V., Syka, J. E. P., Kelleher, N. L., & Fornelli, L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03925 · Cited by 94
Self-citationA comprehensive pipeline for translational top-down proteomics from a single blood draw
Toby, T. K., Fornelli, L., Srzentić, K., DeHart, C. J., Levitsky, J., Friedewald, J., & Kelleher, N. L. (2019) · Nature Protocols · doi:10.1038/s41596-018-0085-7 · Cited by 86
Self-citation
Metadata
- Authors
- Fornelli, L., Ayoub, D., Aizikov, K., Liu, X., Damoc, E., Pevzner, P. A., Makarov, A., Beck, A., & Tsybin, Y. O.
- Venue
- Journal of Proteomics
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 159
- Pages
- 67-76
- ISSN
- 1874-3919 (ISSN-L)
- OpenAlex
- W2591798791
- Cited by
- 70
- References
- 13
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.