The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
The use of computational fluid dynamics in the development of ventricular assist devices
Open accessAbstract
Progress in the field of prosthetic cardiovascular devices has significantly contributed to the rapid advancements in cardiac therapy during the last four decades. The concept of mechanical circulatory assistance was established with the first successful clinical use of heart-lung machines for cardiopulmonary bypass. Since then a variety of devices have been developed to replace or assist diseased components of the cardiovascular system. Ventricular assist devices (VADs) are basically mechanical pumps designed to augment or replace the function of one or more chambers of the failing heart. Computational Fluid Dynamics (CFD) is an attractive tool in the development process of VADs, allowing numerous different designs to be characterized for their functional performance virtually, for a wide range of operating conditions, without the physical device being fabricated. However, VADs operate in a flow regime which is traditionally difficult to simulate; the transitional region at the boundary of laminar and turbulent flow. Hence different methods have been used and the best approach is debatable. In addition to these fundamental fluid dynamic issues, blood consists of biological cells. Device-induced biological complications are a serious consequence of VAD use. The complications include blood damage (haemolysis, blood cell activation), thrombosis and emboli. Patients are required to take anticoagulation medication constantly which may cause bleeding. Despite many efforts blood damage models have still not been implemented satisfactorily into numerical analysis of VADs, which severely undermines the full potential of CFD. This paper reviews the current state of the art CFD for analysis of blood pumps, including a practical critical review of the studies to date, which should help device designers choose the most appropriate methods; a summary of blood damage models and the difficulties in implementing them into CFD; and current gaps in knowledge and areas for future work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wilcox, D. C. (1993) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 7,475
LATTICE BOLTZMANN METHOD FOR FLUID FLOWS
Chen, S., & Doolen, G. D. (1998) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.30.1.329 · Cited by 7,314
Heart Disease and Stroke Statistics—2010 Update: A Report From the American Heart Association
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., Dai, S., De Simone, G., Ferguson, T. B., Ford, E., Furie, K., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192667 · Cited by 5,700
Smoothed Particle Hydrodynamics
Monaghan, J. J. (1992) · Annual Review of Astronomy and Astrophysics · doi:10.1146/annurev.aa.30.090192.002551 · Cited by 4,957
Perspective: A Method for Uniform Reporting of Grid Refinement Studies
Roache, P. J. (1994) · Journal of Fluids Engineering · doi:10.1115/1.2910291 · Cited by 3,135
Proceedings of the 2004 American Control Conference
(2004) · Proceedings of the 2004 American Control Conference · doi:10.23919/acc.2004.1383555 · Cited by 2,605
QUANTIFICATION OF UNCERTAINTY IN COMPUTATIONAL FLUID DYNAMICS
Roache, P. J. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.123 · Cited by 2,319
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-499_7 · Cited by 1,564
1987 american control conference
(1987) · IEEE Control Systems Magazine · doi:10.1109/mcs.1987.1105260 · Cited by 1,402
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Proceedings of the 1993 American Control Conference
(1993) · 1993 American Control Conference · doi:10.23919/acc.1993.4792783 · Cited by 1,310
2007 American Control Conference
(2007) · 2007 American Control Conference · doi:10.1109/acc.2007.4283169 · Cited by 713
Red Blood Cell Damage by Shear Stress
Leverett, L. B., Hellums, J. D., Alfrey, C. P., & Lynch, E. C. (1972) · Biophysical Journal · doi:10.1016/s0006-3495(72)86085-5 · Cited by 682
Walters, D. K., & Čokljat, D. (2008) · Journal of Fluids Engineering · doi:10.1115/1.2979230 · Cited by 628
Giersiepen, M., Wurzinger, L. J., Opitz, R., & Reul, H. (1990) · The International Journal of Artificial Organs · doi:10.1177/039139889001300507 · Cited by 594
Cell Adhesion Mechanisms in Platelets
Varga-Szabo, D., Pleines, I., & Nieswandt, B. (2008) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.150474 · Cited by 588
Bazilevs, Y., Gohean, J. R., Hughes, T. J. R., Moser, R. D., & Zhang, Y. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.04.015 · Cited by 386
Mechanical Properties of the Red Cell Membrane
Rand, R. P. (1964) · Biophysical Journal · doi:10.1016/s0006-3495(64)86784-9 · Cited by 355
Fluid Drop-Like Transition of Erythrocytes under Shear
Schmid-Schönbein, H., & Wells, R. (1969) · Science · doi:10.1126/science.165.3890.288 · Cited by 319
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
The Rheology of Blood Flow in a Branched Arterial System
Shibeshi, S. S., & Collins, W. E. (2005) · Applied Rheology · doi:10.1515/arh-2005-0020 · Cited by 243
Arts, T., Bovendeerd, P. H., Prinzen, F. W., & Reneman, R. S. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82201-9 · Cited by 229
Intra-Aortic Balloon Counterpulsation
Trost, J. C., & Hillis, L. D. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.070 · Cited by 208
A multiscale model of thrombus development
Xu, Z., Chen, N., Kamocka, M. M., Rosen, E. D., & Alber, M. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2007.1202 · Cited by 192
Stassen, J., Arnout, J., & Deckmyn, H. (2004) · Current Medicinal Chemistry · doi:10.2174/0929867043364603 · Cited by 181
Ventricular assist device-related infections
Gordon, R. J., Quagliarello, B., & Lowy, F. D. (2006) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(06)70522-9 · Cited by 175
Oxford Textbook of Medicine , 4th Edn
Hunter, J. M. (2003) · British Journal of Anaesthesia · doi:10.1093/bja/aeg576 · Cited by 164
The flow of blood in tubes: theory and experiment
Yeleswarapu, K. K., Kameneva, M. V., Rajagopal, K. R., & Antaki, J. F. (1998) · Mechanics Research Communications · doi:10.1016/s0093-6413(98)00036-6 · Cited by 159
Immersed-boundary-type models of intravascular platelet aggregation
Fogelson, A. L., & Guy, R. D. (2007) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2007.06.030 · Cited by 152
Assessment of Upper Respiratory Tract and Ocular Irritative Effects of Volatile Chemicals in Humans
Doty, R. L., Cometto‐Muñiz, J. E., Jalowayski, A. A., Dalton, P., Kendal-Reed, M., & Hodgson, M. J. (2004) · Critical Reviews in Toxicology · doi:10.1080/10408440490269586 · Cited by 151
Computational Fluid Dynamics Prediction of Blood Damage in a Centrifugal Pump
Song, X., Throckmorton, A. L., Wood, H. G., et al. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.00026.x · Cited by 143
Continuum Models of Platelet Aggregation: Formulation and Mechanical Properties
Fogelson, A. L. (1992) · SIAM Journal on Applied Mathematics · doi:10.1137/0152064 · Cited by 138
Platelet Dysfunction in Outpatients With Left Ventricular Assist Devices
Steinlechner, B., Dworschak, M., Birkenberg, B., Duris, M., Zeidler, P., Fischer, H., Milošević, L., Wieselthaler, G. M., Wolner, E., Quehenberger, P., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.10.027 · Cited by 134
Computational Fluid Dynamics as a Development Tool for Rotary Blood Pumps
Burgreen, G. W., Antaki, J. F., Wu, Z. J., & Holmes, A. J. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025005336.x · Cited by 131
Self-citationFogelson, A. L., & Tania, N. (2005) · Pathophysiology of Haemostasis and Thrombosis · doi:10.1159/000089930 · Cited by 128
Tank-Tread Frequency of the Red Cell Membrane: Dependence on the Viscosity of the Suspending Medium
Fischer, T. M. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104505 · Cited by 121
Lung Transplantation in the United States, 1998–2007
McCurry, K. R., Shearon, T. H., Edwards, L. B., Chan, K. M., Sweet, S. C., Valapour, M., Yusen, R., & Murray, S. (2009) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2009.02569.x · Cited by 113
Extracorporeal membrane oxygenation
Mielck, F., & Quintel, M. (2005) · Current Opinion in Critical Care · doi:10.1097/00075198-200502000-00014 · Cited by 112
A Validated Computational Fluid Dynamics Model to Estimate Hemolysis in a Rotary Blood Pump
Arvand, A., Hormes, M., & Reul, H. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29089.x · Cited by 108
Computational model of whole blood exhibiting lateral platelet motion induced by red blood cells
Crowl, L. M., & Fogelson, A. L. (2009) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.1274 · Cited by 106
Fogelson, A. L. (2004) · Mathematical Medicine and Biology A Journal of the IMA · doi:10.1093/imammb/21.4.293 · Cited by 105
Analysis and design of micro-climate around the human body with respiration by CFD
Murakami, S. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00283.x · Cited by 104
Haemolysis in patients with ventricular assist devices: major differences between systems☆
Heilmann, C., Geisen, U., Benk, C., Berchtold‐Herz, M., Trummer, G., Schlensak, C., Zieger, B., & Beyersdorf, F. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.04.015 · Cited by 101
Taskin, M. E., Fraser, K., Zhang, T., Gellman, B. N., Fleischli, A., Dasse, K. A., Griffith, B. P., & Wu, Z. J. (2010) · Artificial Organs · doi:10.1111/j.1525-1594.2010.01017.x · Cited by 97
Self-citationA Mathematical Model to Evaluate Control Strategies for Mechanical Circulatory Support
Cox, L. G. E., Loerakker, S., Rutten, M. C. M., de Mol, B. A. J. M., & van de Vosse, F. N. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2009.00755.x · Cited by 84
Human Factors Issues in Ventricular Assist Device Recipients and Their Family Caregivers
Dew, M. A., Kormos, R. L., Winowich, S., Stanford, E., Carozza, L., Borovetz, H. S., & Griffith, B. P. (2000) · ASAIO Journal · doi:10.1097/00002480-200005000-00025 · Cited by 75
Self-citationHochareon, P., Manning, K. B., Fontaine, A. A., et al. (2004) · ASAIO Journal · doi:10.1097/01.mat.0000145694.40637.a0 · Cited by 72
“Shear induced platelet activation” - A critical reappraisal
Wurzinger, L. J., Opitz, R., Wolf, M., & Schmid-Schönbein, H. (1985) · Biorheology · doi:10.3233/bir-1985-22504 · Cited by 66
Computational Flow Optimization of Rotary Blood Pump Components
Antaki, J. F., Ghattas, O. N., Burgreen, G. W., et al. (1995) · Artificial Organs · doi:10.1111/j.1525-1594.1995.tb02389.x · Cited by 62
Characterization of an Abdominal Aortic Velocity Waveform in Patients with Abdominal Aortic Aneurysm
Fraser, K., Meagher, S., Blake, J. R., Easson, W. J., & Hoskins, P. R. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.06.015 · Cited by 54
Self-citationComput. Methods Appl. Mech. Engrg.
Wan, X. (2010) · Cited by 51
Sankaran, S., Audet, C., & Marsden, A. L. (2010) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.03.005 · Cited by 50
Mathematical Modeling of Cardiovascular System Dynamics Using a Lumped Parameter Method
Shim, E. B., Sah, J.-Y., & Youn, C. H. (2004) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.54.545 · Cited by 42
Triep, M., Brücker, C., Schröder, W., et al. (2006) · Artificial Organs · doi:10.1111/j.1525-1594.2006.00230.x · Cited by 36
Okamoto, E., Hashimoto, T., Inoue, T., & Mitamura, Y. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07183.x · Cited by 33
What Price Support? Ventricular Assist Device Induced Systemic Response
Thompson, L. O., Loebe, M. M., & Noon, G. P. (2003) · ASAIO Journal · doi:10.1097/01.mat.0000085672.42122.49 · Cited by 31
Fluid—structure interaction in axially symmetric models of abdominal aortic aneurysms
Fraser, K., Li, M.-X., Lee, W. T., et al. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim443 · Cited by 23
Self-citationA Novel Integrated Rotor of Axial Blood Flow Pump Designed With Computational Fluid Dynamics
Zhang, Y., Xue, S., Gui, X., et al. (2007) · Artificial Organs · doi:10.1111/j.1525-1594.2007.00425.x · Cited by 21
Cited by
Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4007092 · Cited by 384
Self-citationMorrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M. (2019) · ASAIO Journal · doi:10.1097/mat.0000000000000996 · Cited by 68
Metadata
- Authors
- Fraser, K. H., Taskin, M. E., Griffith, B. P., & Wu, Z. J.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2010-11-13
- Volume
- 33
- Issue
- 3
- Pages
- 263-280
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1983406676
- Cited by
- 278
- References
- 58
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.