Comparison of acceleration signals of simulated and real-world backward falls
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Most of the knowledge on falls of older persons has been obtained from oral reports that might be biased in many ways. Fall simulations are widely used to gain insight into circumstances of falls, but the results, at least concerning fall detection, are not convincing. Variation of acceleration and maximum jerk of 5 real-world backward falls of 4 older persons (mean age 68.8 years) were compared to the corresponding signals of simulated backward falls by 18 healthy students. Students were instructed to "fall to the back as if you were a frail old person" during experiment 1. In experiment 2, students were instructed not to fall, if possible, when released from a backward lean. Data acquisition was performed using a tri-axial acceleration sensor. In experiment 1, there was significantly more variation within the acceleration signals and maximum jerk was higher in the real-world falls, compared to the fall simulation. Conversely, all values of acceleration and jerk were higher for the fall simulations, compared to real-world falls in experiment 2. The present findings demonstrate differences between real-world falls and fall simulations. If fall simulations are used, their limitations should be noted and the protocol should be adapted to better match real-world falls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wearable system for pre-impact fall detection
Nyan, M. N., Tay, F. E. H., & Murugasu, E. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.08.009 · Cited by 241
Portable preimpact fall detector with inertial sensors
Wu, G., & Xue, S. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.916282 · Cited by 227
A pilot study of long-term monitoring of human movements in the home using accelerometry
Mathie, M. J., Coster, A. C. F., Lovell, N. H., Celler, B. G., Lord, S. R., & Tiedemann, A. (2004) · Journal of Telemedicine and Telecare · doi:10.1258/135763304323070788 · Cited by 153
Cited by
Sensitivity and False Alarm Rate of a Fall Sensor in Long-Term Fall Detection in the Elderly
Kangas, M., Korpelainen, R., Vikman, I., Nyberg, L., & Jämsä, T. (2015) · Gerontology · doi:10.1159/000362720 · Cited by 18,909
Robinovitch, S. N., Feldman, F., Yang, Y., Schonnop, R., Leung, P. M., Sarraf, T., Sims-Gould, J., & Loughin, M. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61263-x · Cited by 942
Challenges, issues and trends in fall detection systems
Igual, R., Medrano, C., & Plaza, I. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-66 · Cited by 654
UniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
Micucci, D., Mobilio, M., & Napoletano, P. (2017) · doi:10.20944/preprints201706.0033.v2 · Cited by 596
SisFall: A Fall and Movement Dataset
Sucerquia, A., López, J., & Vargas-Bonilla, J. (2017) · Sensors · doi:10.3390/s17010198 · Cited by 530
“As previously stated by [28], the dynamics of simulated (mimicked) and real-world falls can be different.”
BackgroundUniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
Micucci, D., Mobilio, M., & Napoletano, P. (2017) · Applied Sciences · doi:10.3390/app7101101 · Cited by 596
Evaluation of Accelerometer-Based Fall Detection Algorithms on Real-World Falls
Bagalà, F., Becker, C., Cappello, A., Chiari, L., Aminian, K., Hausdorff, J. M., Zijlstra, W., & Klenk, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037062 · Cited by 464
Self-citationUP-Fall Detection Dataset: A Multimodal Approach
Martínez-Villaseñor, L., Ponce, H., Brieva, J., Moya-Albor, E., Núñez-Martínez, J., & Peñafort-Asturiano, C. (2019) · Sensors · doi:10.3390/s19091988 · Cited by 403
Detecting Falls with Wearable Sensors Using Machine Learning Techniques
Özdemir, A., & Barshan, B. (2014) · Sensors · doi:10.3390/s140610691 · Cited by 375
Quantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374
“The first experience with falls detection during everyday life is becoming available, for example by use of a single sensor with accelerometers worn at the lower back.(64) Moreover, it is possible to determine a fall by extracting data from the triaxial accelerometer of smart-phones, which is”
MethodSelf-citationSensors-Based Wearable Systems for Monitoring of Human Movement and Falls
Shany, T., Redmond, S. J., Narayanan, M. R., & Lovell, N. H. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2146246 · Cited by 285
HMM-Based Human Fall Detection and Prediction Method Using Tri-Axial Accelerometer
Tong, L., Song, Q., Ge, Y., & Liu, M. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2245231 · Cited by 238
Automatic Fall Monitoring: A Review
Pannurat, N., Thiemjarus, S., & Nantajeewarawat, E. (2014) · Sensors · doi:10.3390/s140712900 · Cited by 237
“The analysis of fall signals acquired from elderly subjects can be found in [69,92].”
BackgroundInfluentialFall Detection Devices and Their Use With Older Adults: A Systematic Review
Chaudhuri, S., Thompson, H., & Demiris, G. (2014) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3182abe779 · Cited by 215
Review of fall detection techniques: A data availability perspective
Khan, S. S., & Hoey, J. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.10.014 · Cited by 210
“However, we will briefly discuss methods based on fixed threshold(s) and the ones that use sequential classification methods for fall detection.”
MethodUMAFall: A Multisensor Dataset for the Research on Automatic Fall Detection
Casilari, E., Santoyo-Ramón, J. A., & Cano-García, J. M. (2017) · Procedia Computer Science · doi:10.1016/j.procs.2017.06.110 · Cited by 188
Detecting Falls as Novelties in Acceleration Patterns Acquired with Smartphones
Medrano, C., Igual, R., Plaza, I., & Castro, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094811 · Cited by 176
“It is still an open question if these records can be representative of older people’s real falls since their movements are expected to be different from those of young or mature people [26,27].”
BackgroundMethodFall detection with body-worn sensors: A systematic review
for the FARSEEING Consortium and the FARSEEING Meta Database Consensus Group, Schwickert, L., Becker, C., Lindemann, U., Maréchal, C., Bourke, A., Chiari, L., Helbostad, J. L., Zijlstra, W., Aminian, K., et al. (2013) · Zeitschrift für Gerontologie und Geriatrie · doi:10.1007/s00391-013-0559-8 · Cited by 148
Self-citationKangas, M., Vikman, I., Nyberg, L., Korpelainen, R., Lindblom, J., & Jämsä, T. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.016 · Cited by 126
UniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
Micucci, D., Mobilio, M., & Napoletano, P. (2017) · doi:10.20944/preprints201706.0033.v1 · Cited by 596
“Finally, studies on this topic confirm the falls we selected are common in real-life [43, 44, 45, 24].”
BackgroundMeng, L., Zhang, A., Chen, C., Wang, X., Jiang, X., Tao, L., Fan, J., Wu, X., Dai, C., Zhang, Y., et al. (2021) · Sensors · doi:10.3390/s21030799 · Cited by 45
“Two complementary features (maximum jerk and mean jerk) [34,35] were extracted for accelerometers.”
MethodShishov, N., Elabd, K., Komisar, V., Chong, H., & Robinovitch, S. N. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258923 · Cited by 42
“Studies have also examined the accuracy of wearable sensor systems and video-based approaches for detecting falls in the lab environment [21,33,34].”
Background
Metadata
- Authors
- Klenk, J., Becker, C., Lieken, F., Nicolai, S., Maetzler, W., Alt, W., Zijlstra, W., Hausdorff, J. M., van Lummel, R. C., Chiari, L., & Lindemann, U.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2010-11-30
- Volume
- 33
- Issue
- 3
- Pages
- 368-373
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2169558892
- Cited by
- 155
- References
- 3
- FWCI
- 20.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.