The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Slice-to-volume medical image registration: A survey
Open accessAbstract
During the last decades, the research community of medical imaging has witnessed continuous advances in image registration methods, which pushed the limits of the state-of-the-art and enabled the development of novel medical procedures. A particular type of image registration problem, known as slice-to-volume registration, played a fundamental role in areas like image guided surgeries and volumetric image reconstruction. However, to date, and despite the extensive literature available on this topic, no survey has been written to discuss this challenging problem. This paper introduces the first comprehensive survey of the literature about slice-to-volume registration, presenting a categorical study of the algorithms according to an ad-hoc taxonomy and analyzing advantages and disadvantages of every category. We draw some general conclusions from this analysis and present our perspectives on the future of the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Histograms of Oriented Gradients for Human Detection
Dalal, N., & Triggs, B. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.177 · Cited by 33,584
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
A Simplex Method for Function Minimization
Nelder, J. A., & Mead, R. (1965) · The Computer Journal · doi:10.1093/comjnl/7.4.308 · Cited by 28,905
Object recognition from local scale-invariant features
Lowe, D. G. (1999) · Proceedings of the Seventh IEEE International Conference on Computer Vision · doi:10.1109/iccv.1999.790410 · Cited by 16,472
Speeded-Up Robust Features (SURF)
Bay, H., Ess, A., Tuytelaars, T., & Van Gool, L. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2007.09.014 · Cited by 13,557 · cited 2×
“Classical examples of such descriptors successfully applied in different computer vision tasks are the Scale-Invariant Feature Transform (SIFT) (Lowe, 1999), the Harris detector (Harris and Stephens, 1988), the Histogram of Oriented Gradients (HOG) (Dalal and Triggs, 2005), Speeded Up Robust Features (SURF) (Bay et al…”
MethodA Combined Corner and Edge Detector
Harris, C., & Stephens, M. (1988) · Procedings of the Alvey Vision Conference 1988 · doi:10.5244/c.2.23 · Cited by 12,901 · cited 2×
“…successfully applied in different computer vision tasks are the Scale-Invariant Feature Transform (SIFT) (Lowe, 1999), the Harris detector (Harris and Stephens, 1988), the Histogram of Oriented Gradients (HOG) (Dalal and Triggs, 2005), Speeded Up Robust Features (SURF) (Bay et al., 2008),…”
MethodFast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
Shape matching and object recognition using shape contexts
Belongie, S., Malik, J., & Puzicha, J. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.993558 · Cited by 6,306
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Flownet: Learning optical flow with convolutional networks
Dosovitskiy, A., Fischer, P., Ilg, E., Hausser, P., Hazirbas, C., Golkov, V., Smagt, P. V. D., Cremers, D., & Brox, T. (2015) · 2015 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2015.316 · Cited by 4,313
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587 · cited 2×
“We propose a taxonomy based on previous surveys on image registration (Markelj et al., 2010; Sotiras et al., 2013) and adapted to the particular slice-to-volume case (see Figure 1).”
BackgroundMethodThe rules of the game called psychological science
Bakker, M., van Dijk, A., & Wicherts, J. M. (2012) · Perspectives on Psychological Science · doi:10.1177/1745691612459060 · Cited by 800
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
A CNN Regression Approach for Real-Time 2D/3D Registration
Miao, S., Wang, Z. J., & Liao, R. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2521800 · Cited by 514
Fast Predictive Image Registration
Yang, X., Kwitt, R., & Niethammer, M. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46976-8_6 · Cited by 127
Predicting Slice-to-Volume Transformation in Presence of Arbitrary Subject Motion
Hou, B., Alansary, A., McDonagh, S., Davidson, A., Rutherford, M., Hajnal, J. V., Rueckert, D., Glocker, B., & Kainz, B. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66185-8_34 · Cited by 68 · cited 1×
“In that sense, the promising results already achieved (Hou et al., 2017) suggest that shifting to a learning-based slice-to-volume registration paradigm may lead to faster and more accurate predictions, opening new doors in the field.”
Background2d/3d Registration of Endoscopic Ultrasound to Ct Volume Data
Hummel, J., Figl, M., Bax, M., Bergmann, H., & Birkfellner, W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/16/006 · Cited by 47
Cited by
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Image Matching from Handcrafted to Deep Features: A Survey
Ma, J., Jiang, X., Fan, A., Jiang, J., & Yan, J. (2021) · International Journal of Computer Vision · doi:10.1007/s11263-020-01359-2 · Cited by 990
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Kerkech, M., Hafiane, A., & Canals, R. (2020) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2020.105446 · Cited by 317
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
Metadata
- Authors
- Ferrante, E., & Paragios, N.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2017-07
- Volume
- 39
- Pages
- 101-123
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2594602134
- Cited by
- 182
- References
- 20
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.