The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Metallic zinc exhibits optimal biocompatibility for bioabsorbable endovascular stents
Open accessAbstract
Although corrosion resistant bare metal stents are considered generally effective, their permanent presence in a diseased artery is an increasingly recognized limitation due to the potential for long-term complications. We previously reported that metallic zinc exhibited an ideal biocorrosion rate within murine aortas, thus raising the possibility of zinc as a candidate base material for endovascular stenting applications. This study was undertaken to further assess the arterial biocompatibility of metallic zinc. Metallic zinc wires were punctured and advanced into the rat abdominal aorta lumen for up to 6.5 months. This study demonstrated that metallic zinc did not provoke responses that often contribute to restenosis. Low cell densities and neointimal tissue thickness, along with tissue regeneration within the corroding implant, point to optimal biocompatibility of corroding zinc. Furthermore, the lack of progression in neointimal tissue thickness over 6.5 months or the presence of smooth muscle cells near the zinc implant suggest that the products of zinc corrosion may suppress the activities of inflammatory and smooth muscle cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
In vitro and in vivo corrosion measurements of magnesium alloys
Witte, F., Fischer, J., Nellesen, J., Crostack, H.-A., Kaese, V., Pisch, A., Beckmann, F., & Windhagen, H. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.037 · Cited by 1,386
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
Self-citationBiocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B., Rohde, R., Kaese, V, Niemeyer, M., Hartung, W., & Haverich, A. (2003) · Heart · doi:10.1136/heart.89.6.651 · Cited by 806
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Serruys, P. W., Chevalier, B., Dudek, D., Cequier, A., Carrié, D., Iniguez, A., Dominici, M., van der Schaaf, R. J., Haude, M., Wasungu, L., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61455-0 · Cited by 564
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Haude, M., Erbel, R., Erne, P., Verheye, S., Degen, H., Böse, D., Vermeersch, P., Wijnbergen, I., Weissman, N., Prati, F., et al. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61765-6 · Cited by 423
Pathological Analysis of Local Delivery of Paclitaxel Via a Polymer-Coated Stent
Farb, A., Heller, P. F., Shroff, S., Cheng, L., Kolodgie, F. D., Carter, A. J., Scott, D. S., Froehlich, J., & Virmani, R. (2001) · Circulation · doi:10.1161/hc3001.092037 · Cited by 423
Zinc and Regulation of Inflammatory Cytokines: Implications for Cardiometabolic Disease
Foster, M., & Samman, S. (2012) · Nutrients · doi:10.3390/nu4070676 · Cited by 284
CARTER, A. (2004) · Cardiovascular Research · doi:10.1016/j.cardiores.2004.04.029 · Cited by 281
A simplified in vivo approach for evaluating the bioabsorbable behavior of candidate stent materials
Pierson, D., Edick, J., Tauscher, A., Pokorney, E., Bowen, P., Gelbaugh, J., Stinson, J., Getty, H., Lee, C. H., Drelich, J., et al. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31922 · Cited by 195
Self-citationGrube, E., Sonoda, S., Ikeno, F., Honda, Y., Kar, S., Chan, C., Gerckens, U., Lansky, A. J., & Fitzgerald, P. J. (2004) · Circulation · doi:10.1161/01.cir.0000128850.84227.fd · Cited by 191
Bioresorbable Scaffold Technologies
Onuma, Y., Ormiston, J. A., & Serruys, P. W. J. C. (2011) · Circulation Journal · doi:10.1253/circj.cj-10-1135 · Cited by 135
Magnesium in the murine artery: Probing the products of corrosion
Bowen, P. K., Drelich, J. W., & Goldman, J. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.11.021 · Cited by 108
Self-citationZinc restriction during different periods of life: Influence in renal and cardiovascular diseases
Tomat, A. L., Costa, M. A., & Arranz, C. T. (2010) · Nutrition · doi:10.1016/j.nut.2010.09.010 · Cited by 105
Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent
Alexy, R., & Levi, D. S. (2013) · BioMed Research International · doi:10.1155/2013/137985 · Cited by 99
Zartner, P. A., Buettner, M. J., Singer, H., & Sigler, M. (2007) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20828 · Cited by 95
Rates ofin vivo(arterial) andin vitrobiocorrosion for pure magnesium
Bowen, P. K., Drelich, A. J., Drelich, J. W., & Goldman, J. (2014) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35179 · Cited by 88
Self-citationBiodegradable stents: the golden future of angioplasty?
Mario, C. D., & Caiazzo, G. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61636-6 · Cited by 33
Zinc reduces intimal hyperplasia in the rat carotid injury model
Berger, M. (2004) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2004.03.022 · Cited by 27
Cited by
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Self-citationAntibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Biodegradable Metals for Cardiovascular Stents: from Clinical Concerns to Recent Zn‐Alloys
Bowen, P. K., Shearier, E. R., Zhao, S., Guillory, R. J., Zhao, F., Goldman, J., & Drelich, J. W. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201501019 · Cited by 544
Self-citationFundamental Theory of Biodegradable Metals—Definition, Criteria, and Design
Liu, Y., Zheng, Y., Chen, X., Yang, J., Pan, H., Chen, D., Wang, L., Zhang, J., Zhu, D., Wu, S., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805402 · Cited by 519
Metadata
- Authors
- Bowen, P. K., Guillory, R. J., Shearier, E. R., Seitz, J.-M., Drelich, J., Bocks, M., Zhao, F., & Goldman, J.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 56
- Pages
- 467-472
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W932876511
- Cited by
- 261
- References
- 22
- FWCI
- 18.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.