Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Hierarchical elastomer tuned self-powered pressure sensor for wearable multifunctional cardiovascular electronics

Chen, Shuwen, Wu, Nan, Lin, Shizhe, Duan, Jiangjiang, Xu, Zisheng, Pan, Yuan, Zhang, Hongbo, Xu, Zheheng, Huang, Liang, Hu, Bin, Zhou, Jun·2020·Nano Energy

Abstract

Abstract Wearable pressure sensors, as essential components of flexible wearable electronics, may play important roles in early diagnosis and mortality prevention for cardiovascular healthcare. However, traditional self-powered pressure sensors can hardly obtain both high sensitivity and wide pressure range, which makes perceiving both cardiac and vascular signals in a wearable self-powered way challenging as these physiological signals not only have imperceptible changes but also span a broad pressure range. Here, we develop a flexible hierarchical elastomer tuned self-powered pressure sensor, which achieves both high-sensitivity and wide pressure range, showing a high sensitivity of 7.989 V kPa−1 and wide pressure range of 0.1–60 kPa simultaneously. Fast response (40 ms) and high signal noise ratio (38 db) with good stability are also achieved. We demonstrate that the self-powered pressure sensor can not only sensitively monitor pulse, artery and heart condition but also monitor the wide range blood pressure, which satisfies the diverse needs of wearable cardiovascular healthcare. As most of the pressure related to human interface is less than 50 kPa, we envision the sensor holds great potential in wearable electronics, mobile healthcare and human-machine interaction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2020.104460

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 196

Metadata

Authors
Chen, S., Wu, N., Lin, S., Duan, J., Xu, Z., Pan, Y., Zhang, H., Xu, Z., Huang, L., Hu, B., & Zhou, J.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2020-04
Volume
70
Pages
104460
ISSN
2211-2855 (ISSN-L)
OpenAlex
W3000642422
Cited by
196
References
7
FWCI
8.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hierarchical elastomer tuned self-powered pressure sensor for wearable multifunctional cardiovascular electronics. https://app.cochat.ai/papers/10.1016/j.nanoen.2020.104460
The paper
Chen, S., Wu, N., Lin, S., Duan, J., Xu, Z., Pan, Y., Zhang, H., Xu, Z., Huang, L., Hu, B., & Zhou, J. (2020). Hierarchical elastomer tuned self-powered pressure sensor for wearable multifunctional cardiovascular electronics. Nano Energy. https://doi.org/10.1016/j.nanoen.2020.104460

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.