DR-BUDDI (Diffeomorphic Registration for Blip-Up blip-Down Diffusion Imaging) method for correcting echo planar imaging distortions
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
We propose an echo planar imaging (EPI) distortion correction method (DR-BUDDI), specialized for diffusion MRI, which uses data acquired twice with reversed phase encoding directions, often referred to as blip-up blip-down acquisitions. DR-BUDDI can incorporate information from an undistorted structural MRI and also use diffusion-weighted images (DWI) to guide the registration, improving the quality of the registration in the presence of large deformations and in white matter regions. DR-BUDDI does not require the transformations for correcting blip-up and blip-down images to be the exact inverse of each other. Imposing the theoretical “blip-up blip-down distortion symmetry” may not be appropriate in the presence of common clinical scanning artifacts such as motion, ghosting, Gibbs ringing, vibrations, and low signal-to-noise. The performance of DR-BUDDI is evaluated with several data sets and compared to other existing blip-up blip-down correction approaches. The proposed method is robust and generally outperforms existing approaches. The inclusion of the DWIs in the correction process proves to be very important to obtain a reliable correction of distortions in the brain stem. Methods that do not use DWIs may produce a visually appealing correction of the non-diffusion weighted b = 0 s/mm2 images, but the directionally encoded color maps computed from the tensor reveal an abnormal anatomy of the white matter pathways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 2×
“This methodology, which was later released as part of the FSL package (Smith et al., 2004) under the name TOPUP, operates on 3D space instead of the initial method's 1D and can redistribute the signal with a least-squares based method once the B 0 map is estimated.”
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669 · cited 7×
“The reader is referred to (Avants et al., 2008) for further de tails.”
InfluentialA reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796 · cited 2×
“Avants et al. (2008) proposed a non-linear, symmetric, time-varying velocity field based registration algorithm, namely SyN, which quickly became very popular in the image registration community thanks to the ANTS package (Avants et al., 2011).”
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650 · cited 8×
“Therefore, if scan time is an issue for DTI acquisitions, then it might be more advantageous to reduce the number of diffusion-weighted directions and acquire blip-up and down data.”
InfluentialAndersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469 · cited 4×
“The proposed EPI distortion correction method was compared with two other blip-up blip-down methods: TOPUP from the FSL package (Andersson et al., 2003) and EPIC (Holland et al., 2010).”
InfluentialDiffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-citationTuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Correction for geometric distortion in echo planar images from B 0 field variations
Jezzard, P., & Balaban, R. S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340111 · Cited by 1,421 · cited 3×
“Jezzard and Balaban (1995) proposed to map the static magnetic field (or B 0 ) and use this information to perform the EPI correction.”
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403 · cited 2×
“If the synthetic option is preferred, the b=0 s/mm(2) image is estimated from tensor fitting and N DWIs are synthesized based on a gradient scheme originating from the electro-static repulsion method (Jones et al., 1999).”
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142 · cited 1×
“It achieves this by first parameterizing the registration space with time [as initially proposed by Christensen et al. (1996)], with the fixed image representing the image at time point t = 0 and the moving image, the image at time t = 1.”
Advances in diffusion MRI acquisition and processing in the Human Connectome Project
Sotiropoulos, S. N., Jbabdi, S., Xu, J., Andersson, J. L., Moeller, S., Auerbach, E. J., Glasser, M. F., Hernandez, M., Sapiro, G., Jenkinson, M., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.057 · Cited by 891 · cited 2×
“TOPUP has since become a popular blip-up blip-down correction methodology and has been the tool of choice for the Connectome project (Sotiropoulos et al., 2013).”
Pajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Self-citationVector-valued image regularization with PDEs: a common framework for different applications
Tschumperle, D., & Deriche, R. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.87 · Cited by 671 · cited 3×
“: ð28Þ Anisotropic deformation regularization In this section, we will first recap the PDE regularization method for vector images proposed by Tschumperlé & Deriche (2005) and then describe how we use it in our framework.”
InfluentialPajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640 · cited 1×
“Visual inspection was also performed on the DEC maps (Pajevic & Pierpaoli, 1999).”
Self-citationComprehensive approach for correction of motion and distortion in diffusion‐weighted MRI
Rohde, G. K., Barnett, A. S., Basser, P. J., Marenco, S., & Pierpaoli, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10677 · Cited by 533 · cited 3×
“After this step, all DWI volumes in both data sets are aligned to their corresponding b = 0 s/mm 2 images and the B-matrices for all volumes are properly reoriented (Rohde et al., 2004).”
Self-citationCharacterization of anisotropy in high angular resolution diffusion‐weighted MRI
Frank, L. R. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10156 · Cited by 510 · cited 2×
“, 1996) and high angular resolution diffusion imaging (HARDi) (Wedeen et al., 2000; Tuch, 2002, 2004; Tuch et al., 1999; Frank, 2002; Jansons and Alexander, 2003) have been extensively used to investigate the architecture of the human brain.”
Holland, D., Kuperman, J. M., & Dale, A. M. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.044 · Cited by 471 · cited 15×
“Even though the results were acceptable for the RL data when the EPIC method was used, the algorithm failed to correct the distortions for the AP data due to the large motion between the blip-up and down acquisitions.”
InfluentialDeformable registration of diffusion tensor MR images with explicit orientation optimization
ZHANG, H., YUSHKEVICH, P., ALEXANDER, D., & GEE, J. (2006) · Medical Image Analysis · doi:10.1016/j.media.2006.06.004 · Cited by 457 · cited 3×
“For a population analysis of SD maps, all diffusion tensors from both APcorr and RLcorr images for all subjects were first registered nonlinearly using DTITK (Zhang et al., 2006) to obtain the transformations that would morph each tensor to the average morphology of the population, and the resulting RLcorr deformation…”
A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
Chang, H., & Fitzpatrick, J. M. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.158935 · Cited by 425 · cited 1×
“…to the signal pile-up problem involves the acquisition of the same image twice with reversed phase-encoding gradients, as initially proposed by Chang and Fitzpatrick (1992) for images suffering from field inhomogeneities due to imperfections in the magnet system or magnetization of the object…”
Deformable Registration of Diffusion Tensor MR Images with Explicit Orientation Optimization
Zhang, H., Yushkevich, P. A., & Gee, J. C. (2005) · Lecture Notes in Computer Science · doi:10.1007/11566465_22 · Cited by 389
Persistent angular structure: new insights from diffusion magnetic resonance imaging data
Jansons, K. M., & Alexander, D. C. (2003) · Inverse Problems · doi:10.1088/0266-5611/19/5/303 · Cited by 304
Correction of off resonance‐related distortion in echo‐planar imaging using EPI‐based field maps
Reber, P. J., Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390223 · Cited by 223 · cited 2×
“Numerous other methods based on B 0 mapping have been proposed (Reber et al., 1998; Lee et al., 2004; Pintjens et al., 2008; Techavipoo et al., 2009).”
Irfanoglu, M. O., Walker, L., Sarlls, J., Marenco, S., & Pierpaoli, C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.054 · Cited by 215 · cited 5×
“j o u r n a l h o m e p a g e : w w w . e l s e v i e r . c o m / l o c a t e / y n i m g et al., 2008; Irfanoglu et al., 2012), they are inadequate in the presence of extreme signal pile-up.”
InfluentialSelf-citationMorgan, P. S., Bowtell, R. W., McIntyre, D. J. O., & Worthington, B. S. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20032 · Cited by 188 · cited 1×
“In their work adapting this method to EPI, Bowtell et al. (1994) and Morgan et al. (2004) proposed using the " cumulative line-integral " method, which states that the cumulative signal along a phase-encoding line between corresponding points in the up and down images should be equal and that these…”
Mapping fiber orientation spectra in cerebral white matter with Fourier-transform diffusion MRI
Wedeen, V. J., Reese, T. G., Tuch, D. S., Weigel, M., Dou, J., Weisskoff, R. M., & Chessler, D. (2000) · Cited by 188
Unwarping of unidirectionally distorted EPI images
Kybic, J., Thevenaz, P., Nirkko, A., & Unser, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836368 · Cited by 187 · cited 2×
“Correction methods that do not require B0 field maps but other data types, such as dedicated T1 or T2 weighted structural targets, have also been proposed (Kybic et al., 2000; Wu et al., 2008; Tao et al., 2009; Irfanoglu et al., 2011).”
Persistent Angular Structure: New Insights from Diffusion MRI Data. Dummy Version
Jansons, K. M., & Alexander, D. C. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-45087-0_56 · Cited by 168 · cited 2×
“, 1996) and high angular resolution diffusion imaging (HARDi) (Wedeen et al., 2000; Tuch, 2002, 2004; Tuch et al., 1999; Frank, 2002; Jansons and Alexander, 2003) have been extensively used to investigate the architecture of the human brain.”
Distortion correction for diffusion‐weighted MRI tractography and fMRI in the temporal lobes
Embleton, K. V., Haroon, H. A., Morris, D. M., Ralph, M. A. L., & Parker, G. J. M. (2010) · Human Brain Mapping · doi:10.1002/hbm.20959 · Cited by 167 · cited 1×
“Other groups have reported improvements with similar blip-up blip-down strategies for fMRI and DTI data (Voss et al., 2005a, 2005b; Embleton et al., 2010).”
Single-shot diffusion imaging at 2.0 tesla
Turner, R., & Le Bihan, D. (1990) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(90)90023-3 · Cited by 158 · cited 1×
“Diffusionweighted images (DWIs) required for these MRI techniques are generally acquired with echo planar imaging (EPI) (Turner and Le Bihan, 1990).”
Diffusion MRI of complex tissue structure
Tuch, D. S. (2002) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 158
High Angular Resolution Diffusion Imaging of the Human Brain
Tuch, D. S. (1999) · Cited by 156
Bodammer, N., Kaufmann, J., Kanowski, M., & Tempelmann, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10690 · Cited by 149 · cited 2×
“Blip-up blip-down protocols have also been used for purposes other than EPI distortion correction, such as eddy current correction for DWIs (Bodammer et al., 2004), vibration artifact correction (Mohammadi et al., 2012), correction of distortions due to metallic objects (Skare and Andersson, 2005)…”
Comparison of EPI Distortion Correction Methods in Diffusion Tensor MRI Using a Novel Framework
Wu, M., Chang, L., Walker, L., Lemaître, H., Barnett, A. S., Marenco, S., & Pierpaoli, C. M. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85990-1_39 · Cited by 138 · cited 5×
“We tested quantitatively the performance of the various methods using the approach proposed by Wu et al. (2008).”
InfluentialSelf-citationDiffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images
Ruthotto, L., Kugel, H., Olesch, J., Fischer, B., Modersitzki, J., Burger, M., & Wolters, C. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/18/5715 · Cited by 125 · cited 2×
“, 2010), and spe cial deformation field regularizers to better physically model the dis placement field have been employed (Ruthotto et al., 2012).”
Vector-valued image regularization with PDE's: a common framework for different applications
Tschumperlé, D., & Rachid Deriche, B. (2003) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr.2003.1211415 · Cited by 100
Tao, R., Fletcher, P. T., Gerber, S., & Whitaker, R. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02498-6_55 · Cited by 67 · cited 4×
“Metric 4 (ξ4) The typical approach to include signal compression and expansion information in a registration framework is tomodulate the transformed images' signals with the Jacobian determinants of corresponding deformation fields (Tao et al., 2009; Holland et al., 2010).”
InfluentialGallichan, D., Andersson, J., Jenkinson, M., Robson, M. D., & Miller, K. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22318 · Cited by 61 · cited 1×
“There have also been significant developments on the acquisition front (Bhushan et al., 2013; Gallichan et al., 2010; Chang et al., 2013).”
Skare, S. T., & Andersson, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20528 · Cited by 47 · cited 1×
“…been used for purposes other than EPI distortion correction, such as eddy current correction for DWIs (Bodammer et al., 2004), vibration artifact correction (Mohammadi et al., 2012), correction of distortions due to metallic objects (Skare and Andersson, 2005) and N/2 ghosting (Xiang and Ye, 2007).”
Correction of vibration artifacts in DTI using phase‐encoding reversal (COVIPER)
Mohammadi, S., Nagy, Z., Hutton, C., Josephs, O., & Weiskopf, N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23308 · Cited by 43 · cited 2×
“, 2004), vibration artifact correction (Mohammadi et al., 2012), correction of distortions due to metallic objects (Skare and Andersson, 2005) and N/2 ghosting (Xiang and Ye, 2007).”
Bhushan, C., Joshi, A. A., Leahy, R. M., & Haldar, J. P. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25026 · Cited by 31
Toward a practical protocol for human optic nerve DTI with EPI geometric distortion correction
Techavipoo, U., Okai, A. F., Lackey, J., Shi, J., Dresner, M. A., Leist, T. P., & Lai, S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21836 · Cited by 29 · cited 2×
“Numerous other methods based on B 0 mapping have been proposed (Reber et al., 1998; Lee et al., 2004; Pintjens et al., 2008; Techavipoo et al., 2009).”
Irfanoglu, M. O., Walker, L., Sammet, S., Pierpaoli, C. M., & Machiraju, R. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-23629-7_22 · Cited by 24 · cited 2×
“Correction methods that do not require B0 field maps but other data types, such as dedicated T1 or T2 weighted structural targets, have also been proposed (Kybic et al., 2000; Wu et al., 2008; Tao et al., 2009; Irfanoglu et al., 2011).”
Self-citationChang, H., Chuang, T., Lin, Y., Wang, F., Huang, T., & Chung, H. (2013) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2223-4292.2013.03.05 · Cited by 12 · cited 1×
“There have also been significant developments on the acquisition front (Bhushan et al., 2013; Gallichan et al., 2010; Chang et al., 2013).”
Cited by
Building connectomes using diffusion MRI: why, how and but
Sotiropoulos, S. N., & Zalesky, A. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3752 · Cited by 290
Essayed, W. I., Zhang, F., Unadkat, P., Cosgrove, G. R., Golby, A. J., & O'Donnell, L. J. (2017) · NeuroImage: Clinical · doi:10.1016/j.nicl.2017.06.011 · Cited by 245
Latremoliere, A., Cheng, L., DeLisle, M., Wu, C., Chew, S., Hutchinson, E. B., Sheridan, A., Alexandre, C., Latremoliere, F., Sheu, S.-H., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.07.029 · Cited by 183
Self-citationA collaborative resource platform for non-human primate neuroimaging
Messinger, A., Sirmpilatze, N., Heuer, K., Loh, K. K., Mars, R. B., Sein, J., Xu, T., Glen, D., Jung, B., Seidlitz, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117519 · Cited by 52
Thomas, C., Avram, A., Pierpaoli, C., & Baker, C. (2015) · Cortex · doi:10.1016/j.cortex.2015.01.023 · Cited by 44
“Although in the present study we reduced the impact of EPI distortions by using b-spline registration, more accurate corrections can be implemented by using recent advancements such as blip-upeblip-down correction for EPI distortions (Irfanoglu et al., 2014).”
Self-citation
Metadata
- Authors
- Irfanoglu, M. O., Modi, P., Nayak, A., Hutchinson, E. B., Sarlls, J., & Pierpaoli, C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 106
- Pages
- 284-299
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2058734447
- Cited by
- 175
- References
- 43
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.