Key clinical benefits of neuroimaging at 7 T
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The growing interest in ultra-high field MRI, with more than 35.000 MR examinations already performed at 7T, is related to improved clinical results with regard to morphological as well as functional and metabolic capabilities. Since the signal-to-noise ratio increases with the field strength of the MR scanner, the most evident application at 7T is to gain higher spatial resolution in the brain compared to 3T. Of specific clinical interest for neuro applications is the cerebral cortex at 7T, for the detection of changes in cortical structure, like the visualization of cortical microinfarcts and cortical plaques in Multiple Sclerosis. In imaging of the hippocampus, even subfields of the internal hippocampal anatomy and pathology may be visualized with excellent spatial resolution. Using Susceptibility Weighted Imaging, the plaque-vessel relationship and iron accumulations in Multiple Sclerosis can be visualized, which may provide a prognostic factor of disease. Vascular imaging is a highly promising field for 7T which is dealt with in a separate dedicated article in this special issue. The static and dynamic blood oxygenation level-dependent contrast also increases with the field strength, which significantly improves the accuracy of pre-surgical evaluation of vital brain areas before tumor removal. Improvement in acquisition and hardware technology have also resulted in an increasing number of MR spectroscopic imaging studies in patients at 7T. More recent parallel imaging and short-TR acquisition approaches have overcome the limitations of scan time and spatial resolution, thereby allowing imaging matrix sizes of up to 128×128. The benefits of these acquisition approaches for investigation of brain tumors and Multiple Sclerosis have been shown recently. Together, these possibilities demonstrate the feasibility and advantages of conducting routine diagnostic imaging and clinical research at 7T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285 · cited 2×
“The TR can be likewise reduced using simultaneous multi-slice acquisition (Setsompop et al., 2012) which allows a reduction in TR by the multiband factor, increasing the SNR per unit time with only a modest g-factor penalty (Barth et al.”
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Triantafyllou, C., Hoge, R. D., Krueger, G., Wiggins, C. J., Potthast, A., Wiggins, G. C., & Wald, L. L. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.01.007 · Cited by 648
Iron and neurodegeneration in the multiple sclerosis brain
Hametner, S., Wimmer, I., Haider, L., Pfeifenbring, S., Brück, W., & Lassmann, H. (2013) · Annals of Neurology · doi:10.1002/ana.23974 · Cited by 519 · cited 1×
“This is in accord with Hametner et al. (2013), who reported that iron was apparently released from dying oligodendrocytes in active MS lesions, leading to an extracellular accumulation of iron and an uptake into macrophages and microglia.”
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Cerebral microinfarcts: the invisible lesions
Smith, E. E., Schneider, J. A., Wardlaw, J. M., & Greenberg, S. M. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70307-6 · Cited by 456 · cited 2×
“Cerebrovascular disease Cortical microinfarcts (CMIs) are small infarcts (between 50 μm and a few mm) that usually remain undetected with conventional MRI fieldstrengths or at autopsy (Smith et al., 2012; van Veluw et al., 2013).”
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394 · cited 5×
“MR spectroscopy While MR spectroscopy (MRS) of animals, such as rats, at 7 T can be dated back to the 1990 s, the feasibility of in vivo MRS in the human brain at 7 T was first shown in 2001 (Tkáč et al., 2001).”
InfluentialTracking iron in multiple sclerosis: a combined imaging and histopathological study at 7 Tesla
Bagnato, F., Hametner, S., Yao, B., van Gelderen, P., Merkle, H., Cantor, F. K., Lassmann, H., & Duyn, J. H. (2011) · Brain · doi:10.1093/brain/awr278 · Cited by 351
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338 · cited 1×
“The implementation of automatic reconstruction on the scanner console could increase the applicability of SWI, or other methods using phase information, such as Quantitative Susceptibility Mapping (Deistung et al., 2016; Shmueli et al., 2009), in a clinical setting.”
Persistent 7-tesla phase rim predicts poor outcome in new multiple sclerosis patient lesions
Absinta, M., Sati, P., Schindler, M., Leibovitch, E. C., Ohayon, J., Wu, T., Meani, A., Filippi, M., Jacobson, S., Cortese, I. C. M., et al. (2016) · Journal of Clinical Investigation · doi:10.1172/jci86198 · Cited by 327 · cited 7×
“Absinta et al. described the higher background T2 relaxation times of the cortex relative to white matter (WM), that are highest in the subpial cortical layers, as a reason for low cortical lesion contrast (Absinta et al., 2016a).”
InfluentialDisease-specific molecular events in cortical multiple sclerosis lesions
Fischer, M. T., Wimmer, I., Höftberger, R., Gerlach, S., Haider, L., Zrzavy, T., Hametner, S., Mahad, D., Binder, C. J., Krumbholz, M., et al. (2013) · Brain · doi:10.1093/brain/awt110 · Cited by 311 · cited 2×
“subpial demyelination is a specific characteristic of MS; it is found seldom in other inflammatory and neurodegenerative CNS conditions (Fischer et al., 2013).”
Enlarged Perivascular Spaces and Cerebral Small Vessel Disease
Potter, G. M., Doubal, F. N., Jackson, C. A., Chappell, F. M., Sudlow, C. L., Dennis, M. S., & Wardlaw, J. M. (2015) · International Journal of Stroke · doi:10.1111/ijs.12054 · Cited by 296 · cited 1×
“Potter et al. (2015) suggested that enlarged perivascular spaces are an additional MRI marker for SVD.”
Distinct lesion morphology at 7-T MRI differentiates neuromyelitis optica from multiple sclerosis
Sinnecker, T., Dörr, J., Pfueller, C. F., Harms, L., Ruprecht, K., Jarius, S., Brück, W., Niendorf, T., Wuerfel, J., & Paul, F. (2012) · Neurology · doi:10.1212/wnl.0b013e3182648bc8 · Cited by 214 · cited 1×
“In another study Sinnecker et al. (2012) observed that it was possible to distinguish Neuromyelitis Optica Spectrum Disorders (NMOSDs) from MS at 7 T, where the protocol incorporated T2*-weighted FLASH and FLAIR sequences.”
In Vivo Detection of Cerebral Cortical Microinfarcts with High-Resolution 7T MRI
van Veluw, S. J., Zwanenburg, J. J., Engelen-Lee, J., Spliet, W. G., Hendrikse, J., Luijten, P. R., & Biessels, G. J. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.196 · Cited by 193
Subfields of the hippocampal formation at 7 T MRI: In vivo volumetric assessment
Wisse, L. E. M., Gerritsen, L., Zwanenburg, J. J. M., Kuijf, H. J., Luijten, P. R., Biessels, G. J., & Geerlings, M. I. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.023 · Cited by 183 · cited 4×
“7 and 3 mm, may be obtained in vivo using T2-weighted imaging (Theysohn et al., 2009; Wisse et al., 2012).”
InfluentialA Comparison of 3T and 7T in the Detection of Small Parenchymal Veins Within MS Lesions
Tallantyre, E. C., Morgan, P. S., Dixon, J. E., Al-Radaideh, A., Brookes, M. J., Evangelou, N., & Morris, P. G. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e3181b4c144 · Cited by 164 · cited 2×
“Tallantyre et al. (2009) compared 3 T and 7 T T2* imaging in 358 brain lesions identified on 3 T FLAIR images in seven patients with demyelinating brain disease with a focus on the presence or absence of a central vessel within the lesion.”
In vivo assessment of myelination by phase imaging at high magnetic field
Lodygensky, G. A., Marques, J. P., Maddage, R., Perroud, E., Sizonenko, S. V., Hüppi, P. S., & Gruetter, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.057 · Cited by 91 · cited 1×
“These field gradients are mostly prominent in the proximity of tissues with a high iron content (Haacke et al., 2005), densely distributed myelinated axons (Lodygensky et al., 2012) and veins, where the deoxyhemoglobin level is high (Reichenbach et al., 1997).”
Increased Number of Microinfarcts in Alzheimer Disease at 7-T MR Imaging
van Rooden, S., Goos, J. D. C., van Opstal, A. M., Versluis, M. J., Webb, A. G., Blauw, G. J., van der Flier, W. M., Scheltens, P., Barkhof, F., van Buchem, M. A., et al. (2014) · Radiology · doi:10.1148/radiol.13130743 · Cited by 86
Morphological features of MS lesions on FLAIR* at 7 T and their relation to patient characteristics
Kilsdonk, I. D., Lopez-Soriano, A., Kuijer, J. P. A., de Graaf, W. L., Castelijns, J. A., Polman, C. H., Luijten, P. R., Geurts, J. J. J. G., Barkhof, F., & Wattjes, M. P. (2014) · Journal of Neurology · doi:10.1007/s00415-014-7351-6 · Cited by 55
Seven-Tesla proton magnetic resonance spectroscopic imaging in adult X-linked adrenoleukodystrophy
Ratai, E., Kok, T., Wiggins, C., Wiggins, G., Grant, E., Gagoski, B., O’Neill, G., Adalsteinsson, E., & Eichler, F. (2008) · Archives of Neurology · doi:10.1001/archneur.65.11.1488 · Cited by 37 · cited 3×
“MRSI in adult X-linked adrenoleukodystrophy has shown changes in metabolic ratios, such as lower NAA/Cr between different phenotypes and controls (Ratai et al., 2008).”
Cited by
Detcheverry, F., Senthil, S., Narayanan, S., & Badhwar, A. (2023) · NeuroImage: Clinical · doi:10.1016/j.nicl.2023.103503 · Cited by 64
Metadata
- Authors
- Trattnig, S., Springer, E., Bogner, W., Hangel, G., Strasser, B., Dymerska, B., Cardoso, P. L., & Robinson, S. D.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2018-03
- Volume
- 168
- Pages
- 477-489
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2554267839
- Cited by
- 187
- References
- 20
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.