The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Towards a comprehensive framework for movement and distortion correction of diffusion MR images: Within volume movement
Open accessAbstract
Most motion correction methods work by aligning a set of volumes together, or to a volume that represents a reference location. These are based on an implicit assumption that the subject remains motionless during the several seconds it takes to acquire all slices in a volume, and that any movement occurs in the brief moment between acquiring the last slice of one volume and the first slice of the next. This is clearly an approximation that can be more or less good depending on how long it takes to acquire one volume and in how rapidly the subject moves. In this paper we present a method that increases the temporal resolution of the motion correction by modelling movement as a piecewise continous function over time. This intra-volume movement correction is implemented within a previously presented framework that simultaneously estimates distortions, movement and movement-induced signal dropout. We validate the method on highly realistic simulated data containing all of these effects. It is demonstrated that we can estimate the true movement with high accuracy, and that scalar parameters derived from the data, such as fractional anisotropy, are estimated with greater fidelity when data has been corrected for intra-volume movement. Importantly, we also show that the difference in fidelity between data affected by different amounts of movement is much reduced when taking intra-volume movement into account. Additional validation was performed on data from a healthy volunteer scanned when lying still and when performing deliberate movements. We show an increased correspondence between the "still" and the "movement" data when the latter is corrected for intra-volume movement. Finally we demonstrate a big reduction in the telltale signs of intra-volume movement in data acquired on elderly subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630
Self-citationJenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Gaussian Processes for Machine Learning
Rasmussen, C. E., & Williams, C. K. I. (2005) · doi:10.7551/mitpress/3206.001.0001 · Cited by 11,705
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Tract-based spatial statistics: Voxelwise analysis of multi-subject diffusion data
Smith, S. M., Jenkinson, M., Johansen-Berg, H., Rueckert, D., Nichols, T. E., Mackay, C. E., Watkins, K. E., Ciccarelli, O., Cader, M. Z., Matthews, P. M., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.024 · Cited by 6,478
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Methods to detect, characterize, and remove motion artifact in resting state fMRI
Power, J. D., Mitra, A., Laumann, T. O., Snyder, A. Z., Schlaggar, B. L., & Petersen, S. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.08.048 · Cited by 3,748
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Andersson, J. L. R., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.10.019 · Cited by 3,500
Self-citationAndersson, J. L. R., Skare, S., & Ashburner, J. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00336-7 · Cited by 3,469
Self-citationSalimi-Khorshidi, G., Douaud, G., Beckmann, C. F., Glasser, M. F., Griffanti, L., & Smith, S. M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.046 · Cited by 1,770
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586 · cited 2×
“In the Minnesota implementation of the multi-band sequence (Moeller et al., 2010) the slice-ordering di ff ers quite radically depending on if an odd or even number of MB-groups is used (Center for Magnetic Resonance Research, University of Minnesota, 2012).”
MethodOptimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285
Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227
Scattered data interpolation with multilevel B-splines
Lee, S., Wolberg, G., & Shin, S. Y. (1997) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.620490 · Cited by 1,046
Andersson, J. L. R., Graham, M. S., Zsoldos, E., & Sotiropoulos, S. N. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.06.058 · Cited by 763
Self-citationSpurious group differences due to head motion in a diffusion MRI study
Yendiki, A., Koldewyn, K., Kakunoori, S., Kanwisher, N., & Fischl, B. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.027 · Cited by 508
CUDA Application Design and Development
(2011) · doi:10.1016/c2010-0-69090-0 · Cited by 294
Andersson, J. L. R., & Sotiropoulos, S. N. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.067 · Cited by 254
Self-citationJiang, S., Xue, H., Glover, A., Rutherford, M., Rueckert, D., & Hajnal, J. V. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.895456 · Cited by 199
Motion detection and correction in functional MR imaging
Jiang, A., Kennedy, D. N., Baker, J. R., Weisskoff, R. M., Tootell, R. B. H., Woods, R. P., Benson, R. R., Kwong, K. K., Brady, T. J., Rosen, B. R., et al. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030306 · Cited by 195
Krogsrud, S. K., Fjell, A. M., Tamnes, C. K., Grydeland, H., Mork, L., Due-Tønnessen, P., Bjørnerud, A., Sampaio-Baptista, C., Andersson, J., Johansen-Berg, H., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.09.017 · Cited by 190
Self-citationIntersection Based Motion Correction of Multislice MRI for 3-D in Utero Fetal Brain Image Formation
Kim, K., Habas, P. A., Rousseau, F., Glenn, O. A., Barkovich, A. J., & Studholme, C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2030679 · Cited by 170
Motion correction in fMRI via registration of individual slices into an anatomical volume
Kim, B., Boes, J. L., Bland, P. H., Chenevert, T. L., & Meyer, C. R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16>3.0.co;2-d · Cited by 139
Graham, M. S., Drobnjak, I., & Zhang, H. G. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.006 · Cited by 127
Self-citationBeall, E. B., & Lowe, M. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.038 · Cited by 108
Jiang, S., Xue, H., Counsell, S. J., Anjari, M., Allsop, J. M., Rutherford, M., Rueckert, D., & Hajnal, J. V. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22032 · Cited by 98
Drobnjak, I., Gavaghan, D. J., SÜLI, E. E., Pitt‐Francis, J., & Jenkinson, M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20939 · Cited by 98
Self-citationStudy protocol: the Whitehall II imaging sub-study
Filippini, N., Zsoldos, E., Haapakoski, R., Sexton, C. E., Mahmood, A., Allan, C. L., Topiwala, A., Valkanova, V., Brunner, E. J., Shipley, M. J., et al. (2014) · BMC Psychiatry · doi:10.1186/1471-244x-14-159 · Cited by 90
Self-citationHansen, M. F., Seshamani, S., Kroenke, C. D., Cheng, X. E., Chapman, T., Wilm, J., Rousseau, F., & Studholme, C. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2284014 · Cited by 88
Reconstruction of scattered data in fetal diffusion MRI
Oubel, E., Koob, M., Studholme, C., Dietemann, J., & Rousseau, F. (2011) · Medical Image Analysis · doi:10.1016/j.media.2011.04.004 · Cited by 60
Partial k‐space reconstruction in single‐shot diffusion‐weighted echo‐planar imaging
Storey, P., Frigo, F. J., Hinks, R. S., Mock, B. J., Collick, B., Baker, N., Marmurek, J., & Graham, S. J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21132 · Cited by 48
Simulating the effects of time-varying magnetic fields with a realistic simulated scanner
Drobnjak, I., Pell, G. S., & Jenkinson, M. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.03.029 · Cited by 32
Self-citationYeo, D. T. B., Fessler, J. A., & Kim, B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.11.001 · Cited by 22
Bannister, P. R., Brady, J. M., & Jenkinson, M. (2006) · Image and Vision Computing · doi:10.1016/j.imavis.2005.10.002 · Cited by 19
Cited by
MRtrix3: A fast, flexible and open software framework for medical image processing and visualisation
Tournier, J.-D., Smith, R., Raffelt, D., Tabbara, R., Dhollander, T., Pietsch, M., Christiaens, D., Jeurissen, B., Yeh, C.-H., & Connelly, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116137 · Cited by 2,974
Harms, M. P., Somerville, L. H., Ances, B. M., Andersson, J., Barch, D. M., Bastiani, M., Bookheimer, S. Y., Brown, T. B., Buckner, R. L., Burgess, G. C., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.060 · Cited by 584
Self-citationThe impact of T1 versus EPI spatial normalization templates for fMRI data analyses
Calhoun, V. D., Wager, T. D., Krishnan, A., Rosch, K. S., Seymour, K. E., Nebel, M. B., Mostofsky, S. H., Nyalakanai, P., & Kiehl, K. (2017) · Human Brain Mapping · doi:10.1002/hbm.23737 · Cited by 320
Bastiani, M., Cottaar, M., Fitzgibbon, S. P., Suri, S., Alfaro-Almagro, F., Sotiropoulos, S. N., Jbabdi, S., & Andersson, J. L. R. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.073 · Cited by 310
Self-citationThe Human Connectome Project: A retrospective
Elam, J. S., Glasser, M. F., Harms, M. P., Sotiropoulos, S. N., Andersson, J. L. R., Burgess, G. C., Curtiss, S. W., Oostenveld, R., Larson-Prior, L. J., Schoffelen, J.-M., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118543 · Cited by 307
Self-citation
Metadata
- Authors
- Andersson, J. L. R., Graham, M. S., Drobnjak, I., Zhang, H., Filippini, N., & Bastiani, M.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 152
- Pages
- 450-466
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2594272198
- Cited by
- 377
- References
- 37
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.