Strength–duration relationship for intra- versus extracellular stimulation with microelectrodes
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Chronaxie, a historically introduced excitability time parameter for electrical stimulation, has been assumed to be closely related to the time constant of the cell membrane. Therefore, it is perplexing that significantly larger chronaxies have been found for intracellular than for extracellular stimulation. Using compartmental model analysis, this controversy is explained on the basis that extracellular stimulation also generates hyperpolarized regions of the cell membrane hindering a steady excitation as seen in the intracellular case. The largest inside/outside chronaxie ratio for microelectrode stimulation is found in close vicinity of the cell. In the case of monophasic cathodic stimulation, the length of the primarily excited zone which is situated between the hyperpolarized regions increases with electrode-cell distance. For distant electrodes this results in an excitation process comparable to the temporal behavior of intracellular stimulation. Chronaxie also varies along the neural axis, being small for electrode positions at the nodes of Ranvier and axon initial segment and larger at the soma and dendrites. As spike initiation site can change for short and long pulses, in some cases strength-duration curves have a bimodal shape, and thus, they deviate from a classical monotonic curve as described by the formulas of Lapicque or Weiss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pyramidal neurons: dendritic structure and synaptic integration
Spruston, N. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2286 · Cited by 1,688
Action potential initiation and backpropagation in neurons of the mammalian CNS
Stuart, G., Spruston, N., Sakmann, B., & Häusser, M. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(96)10075-8 · Cited by 768
Distinct contributions of Nav1.6 and Nav1.2 in action potential initiation and backpropagation
Hu, W., Tian, C., Li, T., Yang, M., Hou, H., & Shu, Y. (2009) · Nature Neuroscience · doi:10.1038/nn.2359 · Cited by 706
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681
Self-citationAxons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Rattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
Self-citationJensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · cited 2×
“In accordance with retinal ganglion cell experiments (Jensen et al., 2005), for pulse durations 2 ms, it was found that a 500 lm diameter electrode placed above the soma caused excitation with significantly lower thresholds compared to a position above the axon.”
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107 · cited 1×
“1 2007; Sekirnjak et al., 2008; Horsager et al., 2009; Pezaris and Reid, 2009; Tehovnik et al., 2009) while avoiding side effects like co-stimulation of bypassing axons arising from distant locations (Greenberg et al., 1999; Rattay and Resatz, 2004).”
Development of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r01 · Cited by 105 · cited 1×
“…should stimulate elements that elicit visual sensations corresponding to the place in the array (Brindley, 1955; Zrenner, 2002; Dowling, 2005; Fernández et al., 2005; Fried et al., 2006; Cohen, 68 69 70 0306-4522/12 $ - see front matter 2012 Published by Elsevier Ltd on behalf of…”
Efficiency Analysis of Waveform Shape for Electrical Excitation of Nerve Fibers
Wongsarnpigoon, A., Woock, J. P., & Grill, W. M. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047610 · Cited by 104 · cited 2×
“…and Shepherd, 2002; Keren et al., 2009), branching (Manita and Ross, 2009), curvature of axons (Rattay et al., 2000; Iles, 2005), pulse shape (Wongsarnpigoon et al., 2010), electrode configurations (Smith and Finley, 1997), the inhomogeneity and anisotropy in the tissue (Roth, 1995), pulse…”
Cited by
Computational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
“As with the choice of electrical stimuli (see section 3.1), modeling of electrical responses can benefit from biophysical insights, such as the different electrical properties of the axon and soma (Rattay 1986, 1989, Rattay et al 2012).”
BackgroundInfluentialEnergy-optimal electrical-stimulation pulses shaped by the least-action principle
Krouchev, N. I., Danner, S. M., Vinet, A., Rattay, F., & Sawan, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090480 · Cited by 29
Self-citationFine, I., & Boynton, G. M. (2024) · Scientific Reports · doi:10.1038/s41598-024-65337-1 · Cited by 19
Metadata
- Authors
- Rattay, F., Paredes, L. P., & Leao, R. N.
- Venue
- Neuroscience
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 214
- Pages
- 1-13
- ISSN
- 0306-4522 (ISSN-L)
- OpenAlex
- W2054122243
- Cited by
- 81
- References
- 13
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Strength–duration relationship for intra- versus extracellular stimulation with microelectrodes. https://app.cochat.ai/papers/10.1016/j.neuroscience.2012.04.004
- The paper
- Rattay, F., Paredes, L. P., & Leao, R. N. (2012). Strength–duration relationship for intra- versus extracellular stimulation with microelectrodes. Neuroscience. https://doi.org/10.1016/j.neuroscience.2012.04.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.