On the assessment and control optimisation of demand response programs in residential buildings
Open accessThe DOI matches its Crossref record; 151 of the 151 references it cites were found in a registry or an index.
Abstract
The ability to control and optimise energy consumption at end-user level is of increasing interest as a means to achieve a balance between supply and demand, particularly when large penetration of distributed renewable energy sources is being considered. Demand Response programs consist of a series of externally-driven control strategies aimed at adapting consumer end-use load to specific grid requirements. In a demand response scenario, a network of connected systems can be exploited to activate balancing strategies, to provide demand flexibility during periods of high stress for the grid. However, the widespread deployment of demand response programs in the building sector still faces significant challenges. Smart technology deployment, the lack of common standardised assessment procedures and metrics, the absence of established regulatory frameworks are among the main obstacles limiting the development of portfolios of competitive flexibility assets. The residential sector is even more affected by these challenges due to a marginal economic case, the issue of long term harmonisation of hardware and software infrastructure and the influence of the end-user behaviour and preferences on energy consumption. The present paper provides a review on the current developments of the Demand Response programs, with specific reference to the residential building sector. Methodologies and procedures for assessing building energy flexibility and Demand Response programs are described with a special focus on numerical models and available control algorithms. Moreover, markets schemes and social aspects - such as technology acceptance and awareness - and their influence on smart control technologies and algorithms are discussed. Current research gaps and challenges are identified and analysed to provide guidance for future research activities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Mining: Practical Machine Learning Tools and Techniques
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-19715-5 · Cited by 25,437
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“In Ireland and the UK, the domestic sector accounts for more than 26% of the total end-use electricity consumption [6, 7].”
BackgroundEnergyPlus: creating a new-generation building energy simulation program
Crawley, D. B., Lawrie, L. K., Winkelmann, F. C., Buhl, W. F., Huang, Y. J., Pedersen, C. O., Strand, R. K., Liesen, R. J., Fisher, D. E., Witte, M. J., et al. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00114-6 · Cited by 2,822
A review on the prediction of building energy consumption
Zhao, H.-X., & Magoulès, F. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.02.049 · Cited by 1,937 · cited 3×
“The white-box methodology requires a detailed modelling of the system physics equations and, unlike other approaches, can reach higher levels of accuracy when modelling energy consumption [70, 71].”
BackgroundMethodA summary of demand response in electricity markets
Albadi, M. H., & El-Saadany, E. F. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2008.04.002 · Cited by 1,884 · cited 5×
“On the other hand, the PBP scheme is based on electricity tari↵s following the real time price cost [33].”
BackgroundMethodInfluentialA review of data-driven building energy consumption prediction studies
Amasyali, K., & El-Gohary, N. M. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.095 · Cited by 1,874 · cited 1×
“P re p ri nt ranges, represent the main limitations of this approach [103].”
BackgroundOptimal Residential Load Control With Price Prediction in Real-Time Electricity Pricing Environments
Mohsenian-Rad, A.-H., & Leon-Garcia, A. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2055903 · Cited by 1,838
Review of energy system flexibility measures to enable high levels of variable renewable electricity
Lund, P. D., Lindgren, J., Mikkola, J., & Salpakari, J. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.057 · Cited by 1,700 · cited 1×
“A broad range of possible measures to a↵ect energy consumption patterns and magnitude aiming at reducing (energy e ciency measures, peak shaving, demand limiting), increasing (load growth, valley filling) or rescheduling energy demands (load shifting) at the building level can be adopted at building level [16].”
BackgroundDemand side management in smart grid using heuristic optimization
Logenthiran, T., Srinivasan, D., & Shun, T. Z. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2195686 · Cited by 1,229
The Emperor's New Mind: Concerning Computers, Minds, and the Laws of Physics
Penrose, R., & Landauer, R. (1990) · Physics Today · doi:10.1063/1.2810599 · Cited by 1,110
A review of methods to match building energy simulation models to measured data
Coakley, D., Raftery, P., & Keane, M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.007 · Cited by 889 · cited 1×
“Other influencing factors for a calibration methodology selection are: data availability and resolution, the complexity of the building systems (such as the type of heating system), the thermal envelope performance and the occupancy patterns [89].”
BackgroundAbrahamse, W., Steg, L., Vlek, C., & Rothengatter, T. (2007) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2007.08.002 · Cited by 880
Gross, G., & Galiana, F. D. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13927 · Cited by 878 · cited 1×
“The former is important for planning both transmission and distribution networks, whereas the latter is crucial for online scheduling and demand side management [184, 185].”
BackgroundState of the art in building modelling and energy performances prediction: A review
Foucquier, A., Robert, S., Suard, F., Stéphan, L., & Jay, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.004 · Cited by 832 · cited 2×
“Despite the use of SVM is relatively new, they have been e↵ectively employed to predict building heating or cooling load [117], especially with non linear problems and with limited data available.”
BackgroundMethodA review of data-driven approaches for prediction and classification of building energy consumption
Wei, Y., Zhang, X., Shi, Y., Xia, L., Pan, S., Wu, J., Han, M., & Zhao, X. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.108 · Cited by 803 · cited 1×
“Over the last few years, data-driven models gained a lot of attention since they allow good predicting performances, without the necessity to performing detailed analyses on the specific building physical characteristics [102].”
BackgroundOptimal Scheduling of Vehicle-to-Grid Energy and Ancillary Services
Sortomme, E., & El-Sharkawi, M. A. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2164099 · Cited by 707
Identifying suitable models for the heat dynamics of buildings
Bacher, P., & Madsen, H. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.02.005 · Cited by 700 · cited 2×
“Similarly, Bacher and Madsen [99] proposed a bottom-up procedure in which the simplest feasible model is iteratively improved to select more complex ones.”
BackgroundA review on modeling and simulation of building energy systems
Harish, V. S. K. V., & Kumar, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.040 · Cited by 691
2012 American Control Conference (ACC)
(2012) · doi:10.1109/acc19473.2012 · Cited by 669
An overview of Demand Response: Key-elements and international experience
Paterakis, N. G., Erdinç, O., & Catalão, J. P. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.167 · Cited by 640 · cited 3×
“The peak reductions achieved by a smart management at the demand side can reduce the need for infrastructure upgrade, decreasing the overall investment and operating costs and consequently increasing the overall market e ciency [24, 25].”
BackgroundBenefits and challenges of electrical demand response: a critical review
O׳Connell, N., Pinson, P., Madsen, H., & O׳Malley, M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.098 · Cited by 636 · cited 2×
“The restrictive nature of the electricity market, which typically requires stringent performance standards and substantial notice to plan DR actions (typically, many hours in advance), prevents demand from participating e↵ectively in the power market by limiting the flexibility potentially exploitable [11]).”
BackgroundRandom Forest based hourly building energy prediction
Wang, Z., Wang, Y., Zeng, R., Srinivasan, R. S., & Ahrentzen, S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.04.008 · Cited by 635 · cited 1×
“[127] reached average RMSE values below 2%.”
Regression analysis for prediction of residential energy consumption
Fumo, N., & Rafe Biswas, M. A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.03.035 · Cited by 630 · cited 1×
“P re p ri nt This means that SVR predictions can show the best results only at large scale [188].”
BackgroundReview of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629 · cited 2×
“Typically, building models must go under validation and calibration processes which require metered data not always available [30].”
BackgroundDeep learning for estimating building energy consumption
Mocanu, E., Nguyen, P. H., Gibescu, M., & Kling, W. L. (2016) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2016.02.005 · Cited by 622 · cited 1×
“Advanced features such as adaptive learning rate, rate annealing, momentum training, dropout, L1 or L2 regularization, checkpointing, and grid search can enable high predictive accuracy [123].”
BackgroundIEA EBC Annex 67 Energy Flexible Buildings
Jensen, S. Ø., Marszal-Pomianowska, A., Lollini, R., Pasut, W., Knotzer, A., Engelmann, P., Stafford, A., & Reynders, G. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.044 · Cited by 490
Applying support vector machine to predict hourly cooling load in the building
Li, Q., Meng, Q., Cai, J., Yoshino, H., & Mochida, A. (2009) · Applied Energy · doi:10.1016/j.apenergy.2008.11.035 · Cited by 485 · cited 1×
“[118] developed a SVM model using the dry-bulb temperature and the solar radiation as predictor variables, which achieved a mean relative error of 1% in predicting the building cooling load.”
MethodDomestic demand-side management (DSM): Role of heat pumps and thermal energy storage (TES) systems
Arteconi, A., Hewitt, N., & Polonara, F. (2012) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2012.09.023 · Cited by 459 · cited 2×
“Secondly, the time-varying prices provided by utility companies or the electricity market do not necessary match the customer consumption patterns, thereby a form of storage is likely to be required [39].”
BackgroundEnergy flexibility of residential buildings using short term heat storage in the thermal mass
Le Dréau, J., & Heiselberg, P. (2016) · Energy · doi:10.1016/j.energy.2016.05.076 · Cited by 451
Assessment of the theoretical demand response potential in Europe
Gils, H. C. (2014) · Energy · doi:10.1016/j.energy.2014.02.019 · Cited by 442 · cited 1×
“DR has been defined as ”changes in electricity use by demand-side resources from their normal consumption patterns in response to changes in the price of electricity or to incentive payments designed to induce lower electricity use at times of high wholesale market prices or when system reliability is jeopardised” [15…”
BackgroundThe emperor's new mind concerning computers, minds, and the laws of physics
(1990) · Choice Reviews Online · doi:10.5860/choice.27-4496 · Cited by 440
Electricity load forecasting by an improved forecast engine for building level consumers
Liu, Y., Wei, W., & Ghadimi, N. (2017) · Energy · doi:10.1016/j.energy.2017.07.150 · Cited by 410 · cited 1×
“Generally, there are two main types of forecasting: long-term (1-10 years ahead) and short-term (hours-weeks ahead) [182, 183].”
BackgroundCharacterizing the energy flexibility of buildings and districts
Junker, R. G., Azar, A. G., Lopes, R. A., Lindberg, K. B., Reynders, G., Relan, R., & Madsen, H. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.05.037 · Cited by 370 · cited 1×
“) acting as additional boundary conditions [55].”
Li, Q., Meng, Q., Cai, J., Yoshino, H., & Mochida, A. (2008) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.08.033 · Cited by 359
Cătălina, T., Virgone, J., & Blanco, É. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2008.04.001 · Cited by 358 · cited 1×
“[115] developed and validate a multiple regression model for residential buildings in warm climates.”
BackgroundCombined Operations of Renewable Energy Systems and Responsive Demand in a Smart Grid
Cecati, C., Citro, C., & Siano, P. (2011) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2011.2161624 · Cited by 354 · cited 2×
“It can be noted that only few of the paper assessed assessed [138, 149, 169, 170] use a mix of techniques, such as mixed linear integer, continuous integer and quadratic programming, with the aim of reducing power flow overloads caused by variable renewable energy generation or load variations.”
BackgroundDynamic Demand Response Controller Based on Real-Time Retail Price for Residential Buildings
Yoon, J. H., Baldick, R., & Novoselac, A. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2264970 · Cited by 348 · cited 3×
“The remaining two works [156, 171] utilised a model of a single residential building to assess the benefits of the double objective function algorithm.”
BackgroundMethodResidential Demand Response of Thermostatically Controlled Loads Using Batch Reinforcement Learning
Ruelens, F., Claessens, B. J., Vandael, S., De Schutter, B., Babuska, R., & Belmans, R. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517211 · Cited by 333
An Inverse Gray-Box Model for Transient Building Load Prediction
Braun, J. E., & Chaturvedi, N. (2002) · HVAC&R Research · doi:10.1080/10789669.2002.10391290 · Cited by 328 · cited 1×
“Grey-box modelling is a hybrid approach, where physics and data driven components coexist [104].”
Background2006 IEEE Power Engineering Society General Meeting
(2006) · IEEE Power and Energy Magazine · doi:10.1109/mpae.2006.1632461 · Cited by 316
Multiple regression model for fast prediction of the heating energy demand
Cătălina, T., Iordache, V., & Caracaleanu, B. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.11.010 · Cited by 307 · cited 1×
“An update to their work was subsequently published in [116], where the heat consumption was introduced as independent variable.”
BackgroundCommon failures of demand response
Kim, J.-H., & Shcherbakova, A. (2011) · Energy · doi:10.1016/j.energy.2010.12.027 · Cited by 304 · cited 1×
“The importance of developing comprehensive and optimised techno-economic DR programs, but also capable of taking into account social, economic and geographic characteristics was already highlighted in Kim and Shcherbakova [26].”
BackgroundChallenges and barriers to demand response deployment and evaluation
Nolan, S., & O’Malley, M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.04.083 · Cited by 292 · cited 2×
“In addition, DR measures could reduce energy market prices and harmful emissions during peak load periods, since they may be more e cient and cost e↵ective than the generation systems which typically provide these high peak demands [10].”
BackgroundMethodAn integer linear programming based optimization for home demand-side management in smart grid
Zhu, Z., Tang, J., Lambotharan, S., Chin, W. H., & Fan, Z. (2012) · IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT) · doi:10.1109/isgt.2012.6175785 · Cited by 279
Building model calibration using energy and environmental data
Royapoor, M., & Roskilly, T. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.050 · Cited by 277
Is Real-Time Pricing Green? The Environmental Impacts of Electricity Demand Variance
Holland, S. P., & Mansur, E. T. (2008) · Review of Economics and Statistics · doi:10.1162/rest.90.3.550 · Cited by 271
2016 American Control Conference (ACC)
(2016) · doi:10.1109/acc34843.2016 · Cited by 268
Acoustics, Speech and Signal Processing (ICASSP), 2012 IEEE International Conference on
Riedhammer, K., Bocklet, T., Ghoshal, A. K., & Povey, D. (2012) · IEEE International Conference on Acoustics Speech and Signal Processing · Cited by 265
Reddy, T. A. (2006) · ASHRAE winter conference papers · Cited by 253
De Rosa, M., Bianco, V., Scarpa, F., & Tagliafico, L. A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.067 · Cited by 243 · cited 4×
“A 23R7C model to predict the building energy consumption for heating and cooling was developed in [75].”
BackgroundMethodInfluentialSelf-citationReynders, G., Diriken, J., & Saelens, D. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.04.061 · Cited by 241
Ruester, S., Schwenen, S., Batlle, C., & Pérez-Arriaga, I. (2014) · Utilities Policy · doi:10.1016/j.jup.2014.03.007 · Cited by 240 · cited 1×
“, subsidies and aggregation procedure - are limiting the access of end-users (especially in the residential sector) to the energy markets [28].”
BackgroundA day-ahead electricity pricing model based on smart metering and demand-side management
Doostizadeh, M., & Ghasemi, H. (2012) · Energy · doi:10.1016/j.energy.2012.08.029 · Cited by 238
Optimal Power Management of Residential Customers in the Smart Grid
Guo, Y., Pan, M., & Fang, Y. (2012) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2012.25 · Cited by 236
Singaravel, S., Suykens, J., & Geyer, P. (2018) · Advanced Engineering Informatics · doi:10.1016/j.aei.2018.06.004 · Cited by 235 · cited 1×
“DLNN is based on a multi-layer feed-forward ANN trained with stochastic gradient descent using back-propagation [122].”
MethodMethodologies and Advancements in the Calibration of Building Energy Models
Fabrizio, E., & Monetti, V. (2015) · Energies · doi:10.3390/en8042548 · Cited by 233 · cited 1×
“Example of these models can be found in [76] and [77].”
BackgroundSocial implications of residential demand response in cool temperate climates
Darby, S. J., & McKenna, E. (2012) · Energy Policy · doi:10.1016/j.enpol.2012.07.026 · Cited by 233 · cited 4×
“Conventional generation units may not have su cient ramping capabilities to counter these rapid fluctuations McKenna and Keane [1], which might a↵ect grid reliability and wholesale electricity prices [2].”
BackgroundInfluentialOptimized Day-Ahead Pricing for Smart Grids with Device-Specific Scheduling Flexibility
Joe‐Wong, C., Sen, S., Ha, S., & Chiang, M. (2012) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2012.120706 · Cited by 221
Demand response algorithms for smart-grid ready residential buildings using machine learning models
Pallonetto, F., De Rosa, M., Milano, F., & Finn, D. P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.020 · Cited by 213 · cited 2×
“This algorithm category have been extensively used over the last years to predict energy profiles [125] or internal temperature [13].”
BackgroundMethodSelf-citationReynders, G., Diriken, J., & Saelens, D. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.025 · Cited by 210 · cited 2×
“Generally, a grey-box model keeps the physical-based structure to model the system dynamic while statistical and/or optimisation techniques are used to estimate the unknown parameters basing on the experimental dataset [105].”
MethodAdvances in building simulation and computational techniques: A review between 1987 and 2014
Wang, H., & Zhai, Z. J. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.06.080 · Cited by 207 · cited 1×
“The main di culty in implementing these models lies in the need of large dataset of historical data and in the complexity associated with the tuning procedure [69, 85].”
BackgroundA novel ensemble learning approach to support building energy use prediction
Wang, Z., Wang, Y., & Srinivasan, R. S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.085 · Cited by 205 · cited 1×
“Ensemble machine learning methods use multiple learning algorithms to obtain better predictive performance than could be obtained from any of the constituent learning algorithms [124].”
MethodBartusch, C., Wallin, F., Odlare, M., Vassileva, I., & Wester, L. (2011) · Energy Policy · doi:10.1016/j.enpol.2011.06.013 · Cited by 201
Harb, H., Boyanov, N., Hernandez, L., Streblow, R., & Müller, D. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.02.021 · Cited by 198 · cited 2×
“[110] presented a methodology to forecast the thermal response of occupied buildings by calibrating the parameters of four RC models with di↵erent levels of complexity (i.”
MethodQuantification of flexibility in buildings by cost curves – Methodology and application
De Coninck, R., & Helsen, L. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.10.114 · Cited by 198
Reddy, T. A., Maor, I., & Panjapornpon, C. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390952 · Cited by 195
Shen, B., Ghatikar, G., Lei, Z., Li, J., Wikler, G., & Martin, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.12.069 · Cited by 194
Demand-response in building heating systems: A Model Predictive Control approach
Bianchini, G., Casini, M., Vicino, A., & Zarrilli, D. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.01.088 · Cited by 188 · cited 2×
“In the majority of the cases selected the algorithm was embedded in a residential EMS, while only a few cases were concerned with commercial buildings [161].”
BackgroundMethodAnalysis of Residential Demand Response and double-auction markets
Fuller, J. C., Schneider, K. P., & Chassin, D. (2011) · 2011 IEEE Power and Energy Society General Meeting · doi:10.1109/pes.2011.6039827 · Cited by 185
Demand response management by means of heat pumps controlled via real time pricing
Schibuola, L., Scarpa, M., & Tambani, C. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.047 · Cited by 178
Gudi, N., Wang, L., & Devabhaktuni, V. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.05.023 · Cited by 176
Alimohammadisagvand, B., Jokisalo, J., Kilpeläinen, S., Ali, M., & Sirén, K. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.04.013 · Cited by 173 · cited 1×
“The predictive models used for the forecast were linear models [165], auto-regressive statistical models [160, 161], reduced order model [160] or grey-box model [146].”
MethodMicrogrid control methods toward achieving sustainable energy management
Roslan, M. F., Hannan, M. A., Ker, P. J., & Uddin, M. N. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.02.070 · Cited by 173 · cited 1×
“Homeostatic control can be used to balance microgrids equipped with renewable energy systems, such as small wind turbines and photovoltaics [174], and several homeostatic controls were designed both for energy and exergy management of microgrids [176].”
BackgroundBuilding Information Modelling for analysis of energy efficient industrial buildings – A case study
Gourlis, G., & Kovacic, I. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.02.009 · Cited by 172
The 26th Chinese Control and Decision Conference (2014 CCDC)
(2014) · doi:10.1109/ccdc33019.2014 · Cited by 169
Simulation-assisted control in building energy management systems
Clarke, J. A., Cockroft, J., Conner, S., Hand, J. W., Kelly, N., Moore, R., O’Brien, T., & Strachan, P. A. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00068-3 · Cited by 164
Berthou, T., Stabat, P., Salvazet, R., & Marchio, D. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.01.038 · Cited by 164
Saffari, M., de Gracia, A., Fernández, C., Belusko, M., Boer, D., & Cabeza, L. F. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.11.063 · Cited by 162
Robust ensemble learning framework for day-ahead forecasting of household based energy consumption
Alobaidi, M. H., Chebana, F., & Meguid, M. A. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.054 · Cited by 160 · cited 1×
“This algorithm category have been extensively used over the last years to predict energy profiles [125] or internal temperature [13].”
MethodSmall-Scale Building Load Forecast based on Hybrid Forecast Engine
Mohammadi, M., Talebpour, F., Safaee, E., Ghadimi, N., & Abedinia, O. (2018) · Neural Processing Letters · doi:10.1007/s11063-017-9723-2 · Cited by 159 · cited 1×
“The former is important for planning both transmission and distribution networks, whereas the latter is crucial for online scheduling and demand side management [184, 185].”
BackgroundWillingness to participate in direct load control: The role of consumer distrust
Stenner, K., Frederiks, E. R., Hobman, E. V., & Cook, S. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.10.099 · Cited by 159
Modelling the heat consumption in district heating systems using a grey-box approach
Nielsen, H. A., & Madsen, H. (2005) · Energy and Buildings · doi:10.1016/j.enbuild.2005.05.002 · Cited by 159 · cited 2×
“Similarly, Bacher and Madsen [99] proposed a bottom-up procedure in which the simplest feasible model is iteratively improved to select more complex ones.”
MethodResidential Load Modeling of Price-Based Demand Response for Network Impact Studies
McKenna, K., & Keane, A. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2437451 · Cited by 156
Residential Demand Response for Renewable Energy Resources in Smart Grid Systems
Park, L., Jang, Y., Cho, S., & Kim, J. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2704282 · Cited by 146 · cited 2×
“Proposals for new buildings, equipped with connected sensors and smart controllers responsive to smart grid signals [4] have been put forward to achieve flexibility at the end-user side.”
BackgroundZhang, L., Good, N., & Mancarella, P. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.10.058 · Cited by 146 · cited 1×
“[58] proposed a comprehensive set of metrics to quantify building-to-grid DR flexibility from di↵erent stakeholders perspectives (e.”
BackgroundAn Online Learning Algorithm for Demand Response in Smart Grid
Bahrami, S., Wong, V. W. S., & Huang, J. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2667599 · Cited by 144
Humeau, S., Wijaya, T. K., Vasirani, M., & Aberer, K. (2013) · Sustainable Internet and ICT for Sustainability (SustainIT) · doi:10.1109/sustainit.2013.6685208 · Cited by 143 · cited 2×
“[181] explained the relationship between the e↵ectiveness of EMS in leading to cost savings and the accuracy of the load forecast.”
BackgroundMethodOgunjuyigbe, A. S. O., Ayodele, T. R., & Akinola, O. A. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.11.071 · Cited by 143 · cited 1×
“[50] developed an interesting DSM technique capable of controlling the load demand maximising the user satisfaction at the minimum cost.”
2017 Chinese Automation Congress (CAC)
(2017) · doi:10.1109/cac42904.2017 · Cited by 142
Renewable Energy Integration: Challenges and Solutions
Hossain, M. J., & Mahmud, A. (2014) · Green energy and technology · doi:10.1007/978-981-4585-27-9 · Cited by 140
Masy, G., Georges, E., Verhelst, C., Lemort, V., & André, P. (2015) · Science and Technology for the Built Environment · doi:10.1080/23744731.2015.1035590 · Cited by 132
Reduced-order residential home modeling for model predictive control
Cole, W., Powell, K. M., Hale, E. T., & Edgar, T. F. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.01.033 · Cited by 127 · cited 1×
“The predictive models used for the forecast were linear models [165], auto-regressive statistical models [160, 161], reduced order model [160] or grey-box model [146].”
MethodAssessing Beliefs about Lighting Effects on Health, Performance, Mood, and Social Behavior
Veitch, J. A., & Gifford, R. (1996) · Environment and Behavior · doi:10.1177/0013916596284002 · Cited by 125
Knudsen, M. D., & Petersen, S. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.04.053 · Cited by 124 · cited 1×
“A relevant work in the field was Knudsen and Petersen [164] where the authors used an MPC with a double objective function (emissions and electricity price).”
MethodDemand response in the UK's domestic sector
Hamidi, V., Li, F., & Robinson, F. V. P. (2009) · Electric Power Systems Research · doi:10.1016/j.epsr.2009.07.013 · Cited by 122 · cited 2×
“At generation level, DR programs can be a more e cient and cost-e↵ective way to manage peak load periods, limiting the use of expensive peak generators [14, 20].”
BackgroundA grey-box model of next-day building thermal load prediction for energy-efficient control
Zhou, Q., Wang, S., Xu, X., & Xiao, F. (2008) · International Journal of Energy Research · doi:10.1002/er.1458 · Cited by 118
Economic model predictive control for building energy systems
Ma, J., Qin, S. J., Li, B., & Salsbury, T. (2011) · ISGT 2011 · doi:10.1109/isgt.2011.5759140 · Cited by 116
D’Ettorre, F., Conti, P., Schito, E., & Testi, D. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.11.063 · Cited by 116 · cited 1×
“[42] investigated the use of predictive control algorithms for a residential heat pump system which led to a reduction up to 12% of the heating energy cost.”
BackgroundSelf-citationCommunications (ICC), 2012 IEEE International Conference on
Krikidis, I., Charalambous, T., & Thompson, J. T. (2012) · Cited by 114
High resolution modelling of multi-energy domestic demand profiles
Good, N., Zhang, L., Navarro-Espinosa, A., & Mancarella, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.10.028 · Cited by 110
2009 IEEE International Conference on Electro/Information Technology
(2009) · doi:10.1109/eit15078.2009 · Cited by 109
Klaassen, E. A. M., Köbus, C., Frunt, J., & Slootweg, J. G. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.09.051 · Cited by 105
A Literature Review of Methodologies Used to Assess the Energy Flexibility of Buildings
Lopes, R. A., Chambel, A., Neves, J., Aelenei, D., & Martins, J. F. (2016) · Energy Procedia · doi:10.1016/j.egypro.2016.06.274 · Cited by 94
D’Ettorre, F., Роса, М. Д., Conti, P., Testi, D., & Finn, D. (2019) · Sustainable Cities and Society · doi:10.1016/j.scs.2019.101689 · Cited by 93
Self-citationAn optimal scheduling problem in distribution networks considering V2G
Soares, J., Sousa, T. M., Morais, H. G. V., Vale, Z., & Faria, P. (2011) · IEEE Symposium on Computational Intelligence Applications in Smart Grid (CIASG) · doi:10.1109/ciasg.2011.5953342 · Cited by 93
THE ROLE OF DEMAND RESPONSE IN ELECTRIC POWER MARKET DESIGN
Braithwait, S. D., Eakin, K., & Christensen, L. R. (2002) · Cited by 92
Control Strategies for Building Energy Systems to Unlock Demand Side Flexibility – A Review
Clauß, J., Finck, C., Vogler-Finck, P. J. C., & Beagon, P. (2017) · Building Simulation Conference proceedings · doi:10.26868/25222708.2017.462 · Cited by 91
Eco-Feedback on the Go: Motivating Energy Awareness
Spagnolli, A., Corradi, N., Gamberini, L., Hoggan, E., Jacucci, G., Katzeff, C., Broms, L., & Jonsson, L. (2011) · Computer · doi:10.1109/mc.2011.125 · Cited by 89
Jiang, B., & Fei, Y. (2011) · Energy Procedia · doi:10.1016/j.egypro.2011.10.012 · Cited by 87 · cited 1×
“Conventional generation units may not have su cient ramping capabilities to counter these rapid fluctuations McKenna and Keane [1], which might a↵ect grid reliability and wholesale electricity prices [2].”
BackgroundStochastic Model Predictive Control for Demand Response in a Home Energy Management System
Garifi, K., Baker, K., Touri, B., & Christensen, D. (2018) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2018.8586485 · Cited by 85
Insights on Smart Home Concept and Occupants’ Interaction with Building Controls
Fabi, V., Spigliantini, G., & Corgnati, S. P. (2017) · Energy Procedia · doi:10.1016/j.egypro.2017.03.238 · Cited by 83 · cited 2×
“Other social aspects - such as awareness, acceptance and perceived involvement by the end-user - are paramount to achieve high participation rates [31], which is in turn crucial for making of DR programs a successful business case [32].”
BackgroundHedegaard, R. E., Pedersen, T. H., & Petersen, S. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.05.059 · Cited by 81 · cited 1×
“The predictive models used for the forecast were linear models [165], auto-regressive statistical models [160, 161], reduced order model [160] or grey-box model [146].”
MethodAn algorithm for optimal management of aggregated HVAC power demand using smart thermostats
Adhikari, R., Pipattanasomporn, M., & Rahman, S. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.085 · Cited by 76
Current software barriers to advanced model-based control design for energy-efficient buildings
Atam, E. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.015 · Cited by 76
Urban energy simulation: Simplification and reduction of building envelope models
Kim, E.-J., Plessis, G., Hubert, J.-L., & Roux, J.-J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.066 · Cited by 74 · cited 1×
“these characteristics make these models suitable for building aggregation applications [94] - e.”
BackgroundAlibabaei, N., Fung, A. S., & Raahemifar, K. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.05.084 · Cited by 72
Building demand response and control methods for smart grids: A review
Shan, K., Wang, S., Yan, C., & Xiao, F. (2016) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1192878 · Cited by 70
Demand response models with correlated price data: A robust optimization approach
Ferreira, R. S., Barroso, L. A., & de Carvalho, M. M. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.01.016 · Cited by 70
Application of dynamic programming to study load shifting in buildings
Favre, B., & Peuportier, B. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.07.018 · Cited by 67
Роса, М. Д., Carragher, M., & Finn, D. (2018) · Thermal Science and Engineering Progress · doi:10.1016/j.tsep.2018.10.002 · Cited by 66 · cited 7×
“Implementing DR programs in buildings requires the deployment of smart optimisation controllers, which can lead to a more rational use of energy in the building stock, while enabling the exploitation of the user flexibility from a grid perspective to improve the reliability and the e ciency of the power system as a wh…”
BackgroundInfluentialSelf-citationBueno, B., Wienold, J., Katsifaraki, A., & Kuhn, T. E. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.038 · Cited by 66
Model predictive control of thermal storage for demand response
Kircher, K. J., & Zhang, K. M. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7170857 · Cited by 65
Structure-preserving model reduction of nonlinear building thermal models
Deng, K., Goyal, S., Barooah, P., & Mehta, P. G. (2014) · Automatica · doi:10.1016/j.automatica.2014.02.009 · Cited by 60 · cited 1×
“Despite the undoubted economic convenience of avoiding human interaction with the algorithm, the automated procedure may lead to a loss of model structure and, in turn, to a reduction of prediction accuracy, as demonstrated in [112].”
MethodPotential for Domestic Dynamic Demand-Side Management in the UK
Infield, D. G., Short, J. A., Horne, C., & Freris, L. L. (2007) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2007.385696 · Cited by 59
Coordinated home energy management for real-time power balancing
Chang, T., Alizadeh, M., & Scaglione, A. (2012) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2012.6345639 · Cited by 58
Ma, P., Wang, L., & Guo, N. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.02.017 · Cited by 56 · cited 2×
“Homeostatic control has been applied to building energy management systems by introducing the concept of architectural homeostatic buildings (AHBs), defined by as optimallydesigned ”buildings with the architectural elements of high performance envelope and su cient thermal mass” [178], to increase the capability of th…”
BackgroundMethodResidential demand response with interruptible tasks: Duality and algorithms
Gatsis, N., & Giannakis, G. B. (2011) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2011.6161103 · Cited by 54
Aghamohamadi, M., Hajiabadi, M. E., & Samadi, M. (2018) · Energy · doi:10.1016/j.energy.2018.05.034 · Cited by 52 · cited 4×
“This could produce an overall reduction of the carbon footprint of the power grid and lead to a reduction of electricity price [21, 22].”
BackgroundMethodInfluentialA cheat-proof game theoretic demand response scheme for smart grids
Chen, Y., Lin, W., Han, F., Yang, Y., Safar, Z., & Liu, K. J. R. (2012) · International Conference on Communications · doi:10.1109/icc.2012.6364397 · Cited by 48
A novel cost-optimizing demand response control for a heat pump heated residential building
Arabzadeh, V., Vand, B., Jokisalo, J., & Sirén, K. (2017) · Building Simulation · doi:10.1007/s12273-017-0425-5 · Cited by 46
Yanine, F. F., Caballero, F. I., Sauma, E. E., & Córdova, F. M. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.078 · Cited by 46
DEHEMS: creating a digital environment for large-scale energy management at homes
Liu, Q., Cooper, G. S., Linge, N., Takruri, H., & Sowden, R. (2013) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2013.6490242 · Cited by 42 · cited 1×
“[48] developed a domestic energy management software, called DEHEMS, to give direct feedback on energy consumption to persuade users for a behavioural change to achieve energy saving goals.”
MethodCetin, K. S., & O’Neill, Z. D. (2017) · Current Sustainable/Renewable Energy Reports · doi:10.1007/s40518-017-0063-7 · Cited by 37
Ensemble Calibration of lumped parameter retrofit building models using Particle Swarm Optimization
Andrade-Cabrera, C., Burke, D., Turner, W. J. N., & Finn, D. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.035 · Cited by 37 · cited 2×
“The semi-physical interpretation of lumped parameter (RC) approach can be exploited to calibrate a cluster of retrofitted building models simultaneously [76].”
BackgroundSelf-citationHome energy management system for the residential load control based on the price prediction
Ren, D., Li, H., & Ji, Y. (2011) · IEEE Online Conference on Green Communications (OnlineGreenComm) · doi:10.1109/greencom.2011.6082525 · Cited by 37 · cited 1×
“The greedy algorithm developed by [173] provides a useful software infrastructure.”
MethodAn Iterative Methodology for Model Complexity Reduction in Residential Building Simulation
Роса, М. Д., Brennenstuhl, M., Andrade-Cabrera, C., Eicker, U., & Finn, D. (2019) · Energies · doi:10.3390/en12122448 · Cited by 36 · cited 1×
“, Tr) with the variation in parameters ( p), which can be inferred from the semi-physical modelling [113].”
BackgroundSelf-citationSimApi, a smartgrid co-simulation software platform for benchmarking building control algorithms
Pallonetto, F., Mangina, E., Milano, F., & Finn, D. (2019) · SoftwareX · doi:10.1016/j.softx.2019.03.003 · Cited by 34
Self-citationOptimal Power Allocation Under Communication Network Externalities
Kallitsis, M., Michailidis, G. C., & Devetsikiotis, M. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2169995 · Cited by 33 · cited 2×
“[149] is focused on a distributed algorithm that reduces the messaging bandwidth to allocate power in proportion to high uncertainty loads or generation such as renewable, Cecati et al.”
BackgroundBianco, V., Роса, М. Д., Scarpa, F., & Tagliafico, L. A. (2014) · International Journal of Ambient Energy · doi:10.1080/01430750.2014.907207 · Cited by 33
Deconinck, A.-H., & Roels, S. (2017) · Journal of Building Physics · doi:10.1177/1744259116688384 · Cited by 29 · cited 1×
“Even if these unknown parameters may be linked with the physical properties of the building, the use of stochastic models and optimisation algorithms, to achieve good prediction accuracy, could make this link challenging to be formulated [106].”
BackgroundDemand side management in refrigeration applications
Arteconi, A., & Polonara, F. (2017) · International Journal of Heat and Technology · doi:10.18280/ijht.35sp0108 · Cited by 26 · cited 1×
“Over the coming decades, it is expected that a higher penetration of electric heating coupled with Thermal Energy Storage (TES) will occur in the domestic sector [38, 39].”
BackgroundMaximizing the Value of Responsive Load
Cutter, E., Woo, C. K., Kahrl, F., & Taylor, A. (2012) · The Electricity Journal · doi:10.1016/j.tej.2012.08.004 · Cited by 25 · cited 1×
“• Markets and regulatory frameworks: the lack of appropriate market mechanisms for DR programs is one of the greatest barriers for their development [27].”
BackgroundYanine, F. F., & Córdova, F. M. (2013) · International Renewable and Sustainable Energy Conference (IRSEC) · doi:10.1109/irsec.2013.6529647 · Cited by 21 · cited 2×
“Homeostatic control can be used to balance microgrids equipped with renewable energy systems, such as small wind turbines and photovoltaics [174], and several homeostatic controls were designed both for energy and exergy management of microgrids [176].”
BackgroundModel predictive control of building energy systems with balanced model reduction
Ma, Qin, Q., & Salsbury (2012) · Advances in Computing and Communications · Cited by 19
A model-assisted adaptive controller fine-tuning methodology for efficient energy use in buildings
Giannakis, G. B., Kontes, G. D., Kosmatopoulos, E. B., & Rovas, D. (2011) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med.2011.5983175 · Cited by 10
Case Study–Renewable Integration
Rothleder, M., & Loutan, C. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809592-8.00006-8 · Cited by 6
Building energy and control system modeling and simulation using Modelica
He, D., Xiong, Q., Shi, W., et al. (2014) · doi:10.1109/ccdc.2014.6852648 · Cited by 4 · cited 1×
“The separation between the control elements and the equation systems allows for the possibility to restart the integrator, as in the case of model predictive controllers, or to connect the system to other developing environments such as MATLAB \Simulink for control design [83].”
Minimization of electricity demand and cost for multi-zone buildings: Part I—Modeling and validation
Ogunsola, O. T., Song, L., & Tang, C. Y. (2017) · Science and Technology for the Built Environment · doi:10.1080/23744731.2017.1327276 · Cited by 3
Developing a Multiple-Objective Demand Response Algorithm for the Residential Context
Behrens, D., Schoormann, T., & Knackstedt, R. (2018) · Lecture notes in business information processing · doi:10.1007/978-3-319-93931-5_19 · Cited by 1
Cited by
Ahmad, T., Madonski, R., Zhang, D., Huang, C., & Mujeeb, A. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112128 · Cited by 711
Data-driven predictive control for unlocking building energy flexibility: A review
Kathirgamanathan, A., De Rosa, M., Mangina, E., & Finn, D. P. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110120 · Cited by 321
Self-citationExploiting demand-side flexibility: State-of-the-art, open issues and social perspective
D’Ettorre, F., Banaei, M., Ebrahimy, R., Pourmousavi, S. A., Blomgren, E. M. V., Kowalski, J., Bohdanowicz, Z., Łopaciuk-Gonczaryk, B., Biele, C., & Madsen, H. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112605 · Cited by 160
“7 ards and quantification procedure is still a matter of concern [111].”
BackgroundSelf-citation
Metadata
- Authors
- Pallonetto, F., De Rosa, M., D’Ettorre, F., & Finn, D. P.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 127
- Pages
- 109861
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W3016954320
- Cited by
- 169
- References
- 151
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.