Single Cell Mechanotransduction and Its Modulation Analyzed by Atomic Force Microscope Indentation
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
The skeleton adapts to its mechanical usage, although at the cellular level, the distribution and magnitude of strains generated and their detection are ill-understood. The magnitude and nature of the strains to which cells respond were investigated using an atomic force microscope (AFM) as a microindentor. A confocal microscope linked to the setup enabled analysis of cellular responses. Two different cell response pathways were identified: one, consequent upon contact, depended on activation of stretch-activated ion channels; the second, following stress relaxation, required an intact microtubular cytoskeleton. The cellular responses could be modulated by selectively disrupting cytoskeletal components thought to be involved in the transduction of mechanical stimuli. The F-actin cytoskeleton was not required for responses to mechanical strain, whereas the microtubular and vimentin networks were. Treatments that reduced membrane tension, or its transmission, selectively reduced contact reactions. Immunostaining of the cell cytoskeleton was used to interpret the results of the cytoskeletal disruption studies. We provide an estimate of the cellular strain magnitude needed to elicit intracellular calcium responses and propose a model that links single cell responses to whole bone adaptation. This technique may help to understand adaptation to mechanical usage in other organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium's Role in Mechanotransduction during Muscle Development
Benavides Damm, T., & Egli, M. (2014) · Cellular Physiology and Biochemistry · doi:10.1159/000356667 · Cited by 14,502
Down-Regulation of Na+/K+ATPase Activity by Human Parvovirus B19 Capsid Protein VP1
Almilaji, A., Szteyn, K., Fein, E., Pakladok, T., Munoz, C., Elvira, B., Towhid, S. T., Alesutan, I., Shumilina, E., Bock, C.-T., et al. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350083 · Cited by 8,675
The versatility and universality of calcium signalling
Berridge, M. J., Lipp, P., & Bootman, M. D. (2000) · Nature Reviews Molecular Cell Biology · doi:10.1038/35036035 · Cited by 5,701 · cited 3×
“Ca 2ϩ can then activate either calcium-sensitive PLCs or IP 3 receptor channels leading to the release of calcium from intracellular calcium stores.”
BackgroundCalibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Calcium oscillations increase the efficiency and specificity of gene expression
Dolmetsch, R. E., Xu, K., & Lewis, R. S. (1998) · Nature · doi:10.1038/31960 · Cited by 1,893
Maniotis, A. J., Chen, C. S., & Ingber, D. E. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.3.849 · Cited by 1,601
Regulation of bone formation by applied dynamic loads.
Rubin, C. T., & Lanyon, L. E. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00012 · Cited by 1,558
Cellular tensegrity: defining new rules of biological design that govern the cytoskeleton
Ingber, D. E. (1993) · Journal of Cell Science · doi:10.1242/jcs.104.3.613 · Cited by 1,155
Rotsch, C., & Radmacher, M. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76614-8 · Cited by 971
Cell-permeant caged InsP3 ester shows that Ca2+ spike frequency can optimize gene expression
Li, W.-H., Llopis, J., Whitney, M., Zlokarnik, G., & Tsien, R. Y. (1998) · Nature · doi:10.1038/31965 · Cited by 844
Cited by
Nanomechanical analysis of cells from cancer patients
Cross, S. E., Jin, Y.-S., Rao, J., & Gimzewski, J. K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.388 · Cited by 1,908
Materials as stem cell regulators
Murphy, W. L., McDevitt, T. C., & Engler, A. J. (2014) · Nature Materials · doi:10.1038/nmat3937 · Cited by 947
Mechanics, malignancy, and metastasis: The force journey of a tumor cell
Kumar, S., & Weaver, V. M. (2009) · Cancer and Metastasis Reviews · doi:10.1007/s10555-008-9173-4 · Cited by 928
Non-equilibration of hydrostatic pressure in blebbing cells
Charras, G. T., Yarrow, J. C., Horton, M. A., Mahadevan, L., & Mitchison, T. J. (2005) · Nature · doi:10.1038/nature03550 · Cited by 654
Self-citationReassembly of contractile actin cortex in cell blebs
Charras, G. T., Hu, C.-K., Coughlin, M., & Mitchison, T. J. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200602085 · Cited by 619
Self-citationJeyaraj, M., Gurunathan, S., Qasim, M., Kang, M.-H., & Kim, J.-H. (2019) · Nanomaterials · doi:10.3390/nano9121719 · Cited by 481
MECHANOTRANSDUCTION INVOLVING MULTIMODULAR PROTEINS: Converting Force into Biochemical Signals
Vogel, V. (2006) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.35.040405.102013 · Cited by 446
Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D. (2005) · Physical Review E · doi:10.1103/physreve.72.021914 · Cited by 421
Investigating cell mechanics with atomic force microscopy
Haase, K., & Pelling, A. E. (2015) · Journal of The Royal Society Interface · doi:10.1098/rsif.2014.0970 · Cited by 396
Local Nanomechanical Motion of the Cell Wall of Saccharomyces cerevisiae
Pelling, A. E., Sehati, S., Gralla, E. B., Valentine, J. S., & Gimzewski, J. K. (2004) · Science · doi:10.1126/science.1097640 · Cited by 386
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Darling, E. M., Topel, M., Zauscher, S., Vail, T. P., & Guilak, F. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.019 · Cited by 349
Nanoscale Operation of a Living Cell Using an Atomic Force Microscope with a Nanoneedle
Obataya, I., Nakamura, C., Han, Nakamura, N., & Miyake, J. (2005) · Nano Letters · doi:10.1021/nl0485399 · Cited by 336
Nanotechnology for Cell–Substrate Interactions
Sniadecki, N. J., Desai, R. A., Ruiz, S. A., & Chen, C. S. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9006-3 · Cited by 321
Investigating filopodia sensing using arrays of defined nano-pits down to 35 nm diameter in size
Dalby, M. J., Gadegaard, N., Riehle, M. O., Wilkinson, C. D. W., & Curtis, A. S. G. (2004) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2004.03.001 · Cited by 279
Cell fate regulation by coupling mechanical cycles to biochemical signaling pathways
Vogel, V., & Sheetz, M. P. (2009) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2009.01.002 · Cited by 261
Rapid fibroblast adhesion to 27 nm high polymer demixed nano-topography
Dalby, M. J., Giannaras, D., Riehle, M. O., Gadegaard, N., Affrossman, S., & Curtis, A. S. G. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00475-7 · Cited by 236
“Vimentin intermediate filaments are cited as being important in mechanotransductive events to the cell nucleus [16].”
BackgroundAtomic force microscopy of biological samples
Allison, D. P., Mortensen, N. P., Sullivan, C. J., & Doktycz, M. J. (2010) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.104 · Cited by 234
Review on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
“They have also been used to investigate the mechanotransductive response of cells to applied forces [145] [146] or ECM stiffness [131] [147] [148].”
MethodA Three-Dimensional Viscoelastic Model for Cell Deformation with Experimental Verification
Karcher, H., Lammerding, J., Huang, H., Lee, R. T., Kamm, R. D., & Kaazempur-Mofrad, M. R. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74753-5 · Cited by 207
“The high tensile strains in the membrane, as demonstrated by our simulations, can be correlated to previous experimental observations ( Charras and Horton, 2002b ).”
ResultTopographically induced direct cell mechanotransduction
Dalby, M. J. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.04.005 · Cited by 200
“Thus, it is seen that microtubules and intermediate filaments are considered to play the main roles in direct mechanotransduction from the plasma membrane to the nucleus, efficiently sending tensile signals to the nucleus [10,26–30,35,36].”
BackgroundMcgarry, J. G., Klein-Nulend, J., Mullender, M. G., & Prendergast, P. J. (2005) · The FASEB Journal · doi:10.1096/fj.04-2210fje · Cited by 197
“However, an improved approach to modeling the cytoskeleton would incorporate a means of transmitting deformation from the membrane to the nucleus, as suggested by Charras and Horton ( 56 ).”
MethodMagnetic nanoparticle–mediated massively parallel mechanical modulation of single-cell behavior
Tseng, P., Judy, J. W., & Di Carlo, D. (2012) · Nature Methods · doi:10.1038/nmeth.2210 · Cited by 195
“A number of stretch-activated calcium channel blockers 5 , including EGTA quenching of calcium, did not produce a noticeable effect on filopodia (data not shown).”
Finite Element Method (FEM), Mechanobiology and Biomimetic Scaffolds in Bone Tissue Engineering
Boccaccio, A., Ballini, A., Pappalettere, C., Tullo, D., Cantore, S., & Desiate, A. (2011) · International Journal of Biological Sciences · doi:10.7150/ijbs.7.112 · Cited by 178
Mechanosensing through focal adhesion‐anchored intermediate filaments
Gregor, M., Osmanagic‐Myers, S., Burgstaller, G., Wolfram, M., Fischer, I., Walko, G., Resch, G. P., Jörgl, A., Herrmann, H., & Wiche, G. (2014) · The FASEB Journal · doi:10.1096/fj.13-231829 · Cited by 170
Osteoblast Elastic Modulus Measured by Atomic Force Microscopy Is Substrate Dependent
Takai, E., Costa, K. D., Shaheen, A., Hung, C. T., & Guo, X. E. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-3555-3 · Cited by 168
A three-dimensional finite element model of an adherent eukaryotic cell
Centre for Bioengineering, D. O. M. E., McGarry, J., & Prendergast, P. (2004) · European Cells and Materials · doi:10.22203/ecm.v007a03 · Cited by 167
“For example, pulling magnetically on microbeads adherent to cell receptors with a force of 4.4 pN does not alter calcium response (Wu et al., 1999), whereas higher forces of 10 nN applied by atomic force microscopy indentations can modulate intracellular calcium response (Charras and Horton, 2002).”
BackgroundInfluentialInnovative Tools for Mechanobiology: Unraveling Outside-In and Inside-Out Mechanotransduction
Mohammed, D., Versaevel, M., Bruyère, C., Alaimo, L., Luciano, M., Vercruysse, E., Procès, A., & Gabriele, S. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00162 · Cited by 162
“The use of cantilevers with a spherical tip protects the cells against damage during force application and enables to use the AFM as a local indenter (Charras and Horton, 2002).”
MethodHansen, J. C., Yul Lim, J., Xu, L.-C., Siedlecki, C. A., Mauger, D. T., & Donahue, H. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.03.018 · Cited by 80
Metadata
- Authors
- Charras, G. T., & Horton, M. A.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2002-06
- Volume
- 82
- Issue
- 6
- Pages
- 2970-2981
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2110717087
- Cited by
- 281
- References
- 50
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.