Introducing dielectrophoresis as a new force field for field-flow fractionation
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We present the principle of cell characterization and separation by dielectrophoretic field-flow fractionation and show preliminary experimental results. The operational device takes the form of a thin chamber in which the bottom wall supports an array of microelectrodes. By applying appropriate AC voltage signals to these electrodes, dielectrophoretic forces are generated to levitate cells suspended in the chamber and to affect their equilibrium heights. A laminar flow profile is established in the chamber so that fluid flows faster with increasing distance from the chamber walls. A cell carried in the flow stream will attain an equilibrium height, and a corresponding velocity, based on the balance of dielectrophoretic, gravitational, and hydrodynamic lift forces it experiences. We describe a theoretical model for this system and show that the cell velocity is a function of the mean fluid velocity, the voltage and frequency of the signals applied to the electrodes, and, most significantly, the cell dielectric properties. The validity of the model is demonstrated with human leukemia (HL-60) cells subjected to a parallel electrode array, and application of the device to separating HL-60 cells from peripheral blood mononuclear cells is shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Self-citationSeparation of Blood Leucocytes, Granulocytes and Lymphocytes
Bøyum, A. (1974) · Tissue Antigens · doi:10.1111/j.1399-0039.1974.tb00252.x · Cited by 663
Linear and nonlinear electrode polarization and biological materials
Schwan, H. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368531 · Cited by 233
Wang, X.-B., Huang, Y., Gascoyne, P. R. C., Becker, F. F., Hölzel, R., & Pethig, R. (1994) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(94)90170-8 · Cited by 193
Self-citationDielectrophoretic manipulation of cells with spiral electrodes
Wang, X. B., Huang, Y., Wang, X., Becker, F. F., & Gascoyne, P. R. C. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78834-9 · Cited by 134
Self-citationDifferentiation of viable and non-viable bacterial biofilms using electrorotation
Zhou, X., Markx, G. H., Pethig, R., & Eastwood, I. M. (1995) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(95)00072-j · Cited by 68
Field-flow fractionation of macromolecules
Giddings, J. C. (1989) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)83561-5 · Cited by 32
THE USE OF MONOCLONAL ANTIBODIES IN ALLOGENEIC BONE MARROW TRANSPLANTATION
Fischer, A. (1993) · British Journal of Haematology · doi:10.1111/j.1365-2141.1993.tb04686.x · Cited by 12
Cited by
Review Article—Dielectrophoresis: Status of the theory, technology, and applications
Pethig, R. (2010) · Biomicrofluidics · doi:10.1063/1.3456626 · Cited by 1,270
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Self-citationGupta, V., Jafferji, I., Garza, M., Melnikova, V. O., Hasegawa, D. K., Pethig, R., & Davis, D. W. (2012) · Biomicrofluidics · doi:10.1063/1.4731647 · Cited by 383
On-chip micromanipulation and assembly of colloidal particles by electric fields
Velev, O. D., & Bhatt, K. H. (2006) · Soft Matter · doi:10.1039/b605052b · Cited by 361
A Microfabrication-Based Dynamic Array Cytometer
Voldman, J., Gray, M. L., Toner, M., & Schmidt, M. A. (2002) · Analytical Chemistry · doi:10.1021/ac0256235 · Cited by 328
Dielectrophoresis-Based Sample Handling in General-Purpose Programmable Diagnostic Instruments
Gascoyne, P. R. C., & Vykoukal, J. V. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820535 · Cited by 321
Self-citationYang, J., Huang, Y., Wang, X.-B., Becker, F. F., & Gascoyne, P. R. C. (1999) · Analytical Chemistry · doi:10.1021/ac981250p · Cited by 310
Self-citationMicrofluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Microsample preparation by dielectrophoresis: isolation of malaria
Gascoyne, P., Mahidol, C., Ruchirawat, M., Satayavivad, J., Watcharasit, P., & Becker, F. F. (2002) · Lab on a Chip · doi:10.1039/b110990c · Cited by 278
Self-citationIsolation of Circulating Tumor Cells by Dielectrophoresis
Gascoyne, P., & Shim, S. (2014) · Cancers · doi:10.3390/cancers6010545 · Cited by 275
Self-citationPark, S., Zhang, Y., Wang, T.-H., & Yang, S. (2011) · Lab on a Chip · doi:10.1039/c1lc20307j · Cited by 241
Polla, D. L., Erdman, A. G., Robbins, W. P., Markus, D. T., Diaz-Diaz, J., Rizq, R., Nam, Y., Brickner, H. T., Wang, A., & Krulevitch, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.551 · Cited by 220
Antibody-independent isolation of circulating tumor cells by continuous-flow dielectrophoresis
Shim, S., Stemke-Hale, K., Tsimberidou, A. M., Noshari, J., Anderson, T. E., & Gascoyne, P. R. C. (2013) · Biomicrofluidics · doi:10.1063/1.4774304 · Cited by 215
Self-citationRare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
“demonstrated separation of cultured human leukemia cells from diluted blood after characterizing the cells by DEP levitation experiments (Huang et al., 1997), separation of cultured human breast cancer cells from whole blood based on measured differences in cell size and membrane capacitance (Yang et al.”
MethodGreen, N. G., Ramos, A., & Morgan, H. (2002) · Journal of Electrostatics · doi:10.1016/s0304-3886(02)00069-4 · Cited by 181
Separation of Polystyrene Microbeads Using Dielectrophoretic/Gravitational Field-Flow-Fractionation
Wang, X.-B., Vykoukal, J., Becker, F. F., & Gascoyne, P. R. C. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77975-5 · Cited by 175
Self-citationIsolation of circulating tumour cells by physical means in a microfluidic device: a review
Patil, P., Madhuprasad, M., Kumeria, T., Losic, D., & Kurkuri, M. (2015) · RSC Advances · doi:10.1039/c5ra16489c · Cited by 47
Metadata
- Authors
- Huang, Y., Wang, X. B., Becker, F. F., & Gascoyne, P. R.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1997-08
- Volume
- 73
- Issue
- 2
- Pages
- 1118-1129
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2002338347
- Cited by
- 302
- References
- 9
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.