Abstract
We investigated the potential of the Utah Intracortical Electrode Array (UIEA) to provide signals for a brain-computer interface (BCI). The UIEA records from small populations of neurons which have an average signal-to-noise ratio (SNR) of 6:1. We provide specific examples that show the activities of these populations of neurons contain sufficient information to perform control tasks. Results from a simple stimulus detection task using these signals as inputs confirm that the number of neurons present in a recording is significant in determining task performance. Increasing the number of units in a recording decreases the sensitivity of the response to the stimulus; decreasing the number of units in the recording, however, increases the variability of the response to the stimulus. We conclude that recordings from small populations of neurons, not single units, provide a reliable source of sufficiently stimulus selective signals which should be suitable for a BCI. In addition, the potential for simultaneous and proportional control of a large number of external devices may be realized through the ability of an array of microelectrodes such as the UIEA to record both spatial and temporal patterns of neuronal activation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [306]
Citations
Cites
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
The two-dimensional spatial structure of simple receptive fields in cat striate cortex
Jones, J. P., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1187 · Cited by 668
Size, laminar and columnar distribution of efferent cells in the sensory‐motor cortex of monkeys
Jones, E. G., & Wise, S. P. (1977) · Journal of Comparative Neurology · doi:10.1002/cne.901750403 · Cited by 508
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The Motor Cortex and the Coding of Force
Georgopoulos, A. P., Ashe, J., Smyrnis, N., & Taira, M. (1992) · Science · doi:10.1126/science.256.5064.1692 · Cited by 460
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. D. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 370
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Self-citationA glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationSpatial organization of precentral cortex in awake primates. II. Motor outputs.
Kwan, H. C., MacKay, W. A., Murphy, J. T., & Wong, Y. C. (1978) · Journal of Neurophysiology · doi:10.1152/jn.1978.41.5.1120 · Cited by 348
Organization of corticospinal neurons in the monkey
Murray, E. A., & Coulter, J. D. (1981) · Journal of Comparative Neurology · doi:10.1002/cne.901950212 · Cited by 344
Schwartz, A. B., & Moran, D. W. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.82.5.2705 · Cited by 328
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationThe density of synapses and neurones in the motor and visual areas of the cerebral cortex.
Cragg, B. G. (1967) · PubMed Central · Cited by 281
The two-dimensional spectral structure of simple receptive fields in cat striate cortex
Jones, J. P., Stepnoski, A., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1212 · Cited by 262
The variability of discharge of simple cells in the cat striate cortex
Dean, A. F. (1981) · Experimental Brain Research · doi:10.1007/bf00238837 · Cited by 231
Recent developments in the study of the columnar arrangement of neurons within the motor cortex
Asanuma, H. (1975) · Physiological Reviews · doi:10.1152/physrev.1975.55.2.143 · Cited by 206
Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissue
Schmidt, S., Horch, K., & Normann, R. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820271106 · Cited by 183
Self-citationHistopathological evaluation of materials implanted in the cerebral cortex
Stensaas, S. S., & Stensaas, L. J. (1978) · Acta Neuropathologica · doi:10.1007/bf00689766 · Cited by 176
Motor cortical activity during drawing movements: population representation during sinusoid tracing
Schwartz, A. B. (1993) · Journal of Neurophysiology · doi:10.1152/jn.1993.70.1.28 · Cited by 144
Computer separation of multi-unit neuroelectric data: a review
Schmidt, E. M. (1984) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(84)90009-8 · Cited by 135
WINFIELD, D. A., GATTER, K. C., & POWELL, T. P. S. (1980) · Brain · doi:10.1093/brain/103.2.245 · Cited by 134
Schmidt, E. M. (1980) · Annals of Biomedical Engineering · doi:10.1007/bf02363437 · Cited by 126
Population encoding of spatial frequency, orientation, and color in macaque V1
Victor, J. D., Purpura, K., Katz, E., & Mao, B. (1994) · Journal of Neurophysiology · doi:10.1152/jn.1994.72.5.2151 · Cited by 115
Optimal detection, classification, and superposition resolution in neural waveform recordings
Bankman, I. N., Johnson, K. O., & Schneider, W. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238472 · Cited by 108
Simultaneous individual recordings from many cerebral neurons: Techniques and results
Krüger, J. (1983) · Reviews of physiology, biochemistry and pharmacology · doi:10.1007/bfb0033868 · Cited by 100
Optimizing recording capabilities of the Utah Intracortical Electrode Array
Nordhausen, C. T., Rousche, P. J., & Normann, R. A. (1994) · Brain Research · doi:10.1016/0006-8993(94)91213-0 · Cited by 100
Self-citationRelating motor cortex spike trains to measures of motor performance
Humphrey, D. R. (1972) · Brain Research · doi:10.1016/0006-8993(72)90099-6 · Cited by 84
Beaulieu, C., & Colonnier, M. (1989) · Journal of Comparative Neurology · doi:10.1002/cne.902790206 · Cited by 69
Pfurtscheller, G., Flotzinger, D., Mohl, W., & Peltoranta, M. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90112-u · Cited by 68
EXTRACELLULAR POTENTIAL FIELDS OF SINGLE SPINAL MOTONEURONS
Nelson, P. G., & Frank, K. (1964) · Journal of Neurophysiology · doi:10.1152/jn.1964.27.5.913 · Cited by 66
Dr, H., Corrie, W. S., & Rietz, R. R. (1978) · PubMed · Cited by 26
Velocity sensitivity mechanisms in cat visual cortex
Duysens, J., Orban, G. A., & Verbeke, O. B. (1982) · Experimental Brain Research · doi:10.1007/bf00235789 · Cited by 14
Visual receptive fields of local intracortical potentials
Lohmann, H., Eckhorn, R., & Reitboeck, H. J. (1988) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(88)90117-3 · Cited by 8
Research works printed but not linked: 2
- Heetderks, 1995, Command-control signals from the neural activity of motor cortical cells: joy-stick control, Vol. 15, 664
- Humphrey, 1995, Intracortical recording of brain activity for control of limb prostheses, Vol. 15, 650
Cited by
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“With regard to the application of intracortical neuron recording in BCI systems, microelectrode arrays such as the Utah Intracortical Electrode Array (UIEA) have been reported as a suitable means of providing simultaneous and proportional control of a large number of external devices [72].”
BackgroundMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Metadata
- Authors
- Maynard, E. M., Nordhausen, C. T., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard A.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1997-03
- Volume
- 102
- Issue
- 3
- Pages
- 228-239
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2020769260
- Semantic Scholar
- 8c017a2d9f35afc32fabba0f5b65a52191c82682
- Cited by
- 640
- References
- 37
- Citations by year
- 2026: 20 · 2025: 48 · 2024: 34 · 2023: 39 · 2022: 35 · 2021: 34 · 2020: 26 · 2019: 27 · 2018: 31 · 2017: 41 · 2016: 29 · 2015: 22 · 2014: 26 · 2013: 18 · 2012: 22
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Electroencephalography and Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- brain-computer interface, intracortical microelectrode arrays, signal-to-noise ratio, stimulus detection, neural decoding
- MeSH terms
- Action Potentials, Animals, Brain, Cats, Computers, Microelectrodes, Neurons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.