The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfaces
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
We investigated the potential of the Utah Intracortical Electrode Array (UIEA) to provide signals for a brain-computer interface (BCI). The UIEA records from small populations of neurons which have an average signal-to-noise ratio (SNR) of 6:1. We provide specific examples that show the activities of these populations of neurons contain sufficient information to perform control tasks. Results from a simple stimulus detection task using these signals as inputs confirm that the number of neurons present in a recording is significant in determining task performance. Increasing the number of units in a recording decreases the sensitivity of the response to the stimulus; decreasing the number of units in the recording, however, increases the variability of the response to the stimulus. We conclude that recordings from small populations of neurons, not single units, provide a reliable source of sufficiently stimulus selective signals which should be suitable for a BCI. In addition, the potential for simultaneous and proportional control of a large number of external devices may be realized through the ability of an array of microelectrodes such as the UIEA to record both spatial and temporal patterns of neuronal activation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional commercial implantable neural interfaces (e.g., Utah electrodes[306] and Michigan electrodes[307]) typically contain noble metals[308] (high conductivity and chemical stability), and silicon-based materials[309] (ideally suited to existing microfabrication techniques) as electrodes.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [306]
Citations
Cites
Receptive fields, binocular interaction and functional architecture in the cat’s visual cortex
Hubel, D. H., & Wiesel, T. N. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006837 · Cited by 13,680
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
The two-dimensional spatial structure of simple receptive fields in cat striate cortex
Jones, J. P., & Palmer, L. A. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.58.6.1187 · Cited by 668
Size, laminar and columnar distribution of efferent cells in the sensory‐motor cortex of monkeys
Jones, E. G., & Wise, S. P. (1977) · Journal of Comparative Neurology · doi:10.1002/cne.901750403 · Cited by 508
Electrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The Motor Cortex and the Coding of Force
Georgopoulos, A. P., Ashe, J., Smyrnis, N., & Taira, M. (1992) · Science · doi:10.1126/science.256.5064.1692 · Cited by 460
Multichannel EEG-based brain-computer communication
Wolpaw, J. R., & McFarland, D. J. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90135-x · Cited by 449
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. D. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 370
Research works printed but not linked: 2
- Heetderks, 1995, Command-control signals from the neural activity of motor cortical cells: joy-stick control, Vol. 15, 664
- Humphrey, 1995, Intracortical recording of brain activity for control of limb prostheses, Vol. 15, 650
Cited by
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
“With regard to the application of intracortical neuron recording in BCI systems, microelectrode arrays such as the Utah Intracortical Electrode Array (UIEA) have been reported as a suitable means of providing simultaneous and proportional control of a large number of external devices [72].”
BackgroundMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
An Integrated Brain-Machine Interface Platform With Thousands of Channels
Musk, E., & Neuralink (2019) · Journal of Medical Internet Research · doi:10.2196/16194 · Cited by 1,206
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings.
Steinmetz, N. A., Aydin, C., Lebedeva, A., Okun, M., Pachitariu, M., Bauza, M., Beau, M., Bhagat, J., Böhm, C., Broux, M., et al. (2021) · Science · doi:10.1126/science.abf4588 · Cited by 1,173
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Connecting cortex to machines: recent advances in brain interfaces
Donoghue, J. P. (2002) · Nature Neuroscience · doi:10.1038/nn947 · Cited by 721
“More advanced multiple electrode array systems are also being developed using advanced manufacturing and design method”
MethodWireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
“Their implant, named the Utah probe, was a 10 10 array of silicon-etched rigid needles (111, 537, 593).”
BackgroundChronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Self-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Cortical travelling waves: mechanisms and computational principles
Muller, L., Chavane, F., Reynolds, J., & Sejnowski, T. J. (2018) · Nature Reviews Neuroscience · doi:10.1038/nrn.2018.20 · Cited by 604
“These techniques record from single regions in the cortex with high temporal and spatial resolution 36,37 .”
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
Denby, B., Schultz, T., Honda, K., Hueber, T., Gilbert, J. M., & Brumberg, J. S. (2010) · Speech Communication · doi:10.1016/j.specom.2009.08.002 · Cited by 487
“Two electrode designs in particular have been implanted in human subjects for the purpose of brain computer interfacing: the Utah microelectrode array (Maynard et al., 1997; Hochberg et al., 2006), and the Neurotrophic Electrode (Kennedy, 1989; Bartels et al., 2008).”
MethodBayesian Population Decoding of Motor Cortical Activity Using a Kalman Filter
Wu, W., Gao, Y., Bienenstock, E., Donoghue, J. P., & Black, M. J. (2006) · Neural Computation · doi:10.1162/089976606774841585 · Cited by 456
“Details of the array and recording protocols are described elsewhere (Maynard, Nordhausen, & Normann, 1997; Maynard et al., 1999).”
MethodRetinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
“Penetrating electrodes within the cortical tissue have the potential to record single neuron activity in addition to multi-unit activity recorded by epidural electrodes.(90,137) Other invasive methods for recording visually evoked potentials or EERs were tested.”
BackgroundMethodSuner, S., Fellows, M. R., Vargas-Irwin, C., Nakata, G. K., & Donoghue, J. P. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.857687 · Cited by 415
“The details of the design and fabrication of the microelectrodes have been described in detail elsewhere by Normann and colleagues [4], [6].”
BackgroundMethodComplex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Real-time EEG analysis with subject-specific spatial patterns for a brain-computer interface (BCI)
Guger, C., Ramoser, H., & Pfurtscheller, G. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.895947 · Cited by 383
Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M. A., Hanson, T. L., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Microelectrodes, Microelectronics, and Implantable Neural Microsystems
Wise, K. D., Sodagar, A. M., Yao, Y., Gulari, M. N., Perlin, G. E., & Najafi, K. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922564 · Cited by 335
“The two-dimensional silicon depth arrays developed at the University of Utah [ 38 ], [39] are based on glass reflow, sawing, and etching.”
MethodChallenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 333
“Utah array [23] Passive Si IrOx 23–106 (diam.”
BackgroundRobust, automatic spike sorting using mixtures of multivariate t-distributions
Shoham, S., Fellows, M. R., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00120-1 · Cited by 326
Self-citationToward a comparison of microelectrodes for acute and chronic recordings
Ward, M. P., Rajdev, P., Ellison, C., & Irazoqui, P. P. (2009) · Brain Research · doi:10.1016/j.brainres.2009.05.052 · Cited by 296
“Keywords: Microelectrode Signal-to-noise ratio Disease Prosthesis Inflammation Epilepsy”
BackgroundInfluentialLarge-scale neural recordings with single neuron resolution using Neuropixels probes in human cortex
Paulk, A. C., Kfir, Y., Khanna, A. R., Mustroph, M. L., Trautmann, E. M., Soper, D. J., Stavisky, S. D., Welkenhuysen, M., Dutta, B., Shenoy, K. V., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-021-00997-0 · Cited by 283
Neuronal Interactions Improve Cortical Population Coding of Movement Direction
Maynard, E. M., Hatsopoulos, N. G., Ojakangas, C. L., Acuna, B. D., Sanes, J. N., Normann, R. A., & Donoghue, J. P. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-18-08083.1999 · Cited by 281
“Array electrodes often recorded action potentials originating from more than one neuron (Nordhausen et al., 1996; Maynard et al., 1997 ) and ranged from multiple nonclassifiable units to well isolated potentials.”
BackgroundSelf-citationBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
“, 1970), silicon etched arrays (Jones et al., 1992; Maynard et al., 1997; Rousche and Normann, 1998) and neurotrophic microwires (Kennedy, 1989; Kennedy et al.”
BackgroundInfluentialThe stimulus-evoked population response in visual cortex of awake monkey is a propagating wave
Muller, L., Reynaud, A., Chavane, F., & Destexhe, A. (2014) · Nature Communications · doi:10.1038/ncomms4675 · Cited by 259
Accurate Estimation of Neural Population Dynamics without Spike Sorting
Trautmann, E. M., Stavisky, S. D., Lahiri, S., Ames, K. C., Kaufman, M. T., O’Shea, D. J., Vyas, S., Sun, X., Ryu, S. I., Ganguli, S., et al. (2019) · Neuron · doi:10.1016/j.neuron.2019.05.003 · Cited by 255
A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array
Manickam, A., Chevalier, A. A., McDermott, M. W., Ellington, A. D., & Hassibi, A. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081669 · Cited by 271
Encapsulation of an Integrated Neural Interface Device With Parylene C
Hsu, J.-M., Rieth, L., Normann, R. A., Tathireddy, P., & Solzbacher, F. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2002155 · Cited by 241
“THE UTAH Electrode Array (UEA) was developed to record or elicit neural action potentials for the application of restoring neural functions disrupted by disorders or injuries and to conduct basic neuroscience research [1]–[3].”
MethodSelf-citationSingle-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234
“All electrodes of these arrays were 1 mm in length and the procedure for implanting the Utah array has been described elsewhere (Maynard et al. 1997, 1999; Rousche and Normann 1992).”
MethodA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Self-citationShain, W., Spataro, L., Dilgen, J., Haverstick, K., Retterer, S., Isaacson, M., Saltzman, M., & Turner, J. N. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814800 · Cited by 227
Enhancement of Left-Right Sensorimotor EEG Differences During Feedback-Regulated Motor Imagery
Neuper, C., Schlögl, A., & Pfurtscheller, G. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199907000-00010 · Cited by 225
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
“H IGH-DENSITY arrays of silicon-based microelectrodes [1], [2] for recording single-unit neural activity in the central nervous system are widely viewed as a promising path to revolutionary progress in understanding neural functions and to”
BackgroundSpataro, L., Dilgen, J., Retterer, S., Spence, A. J., Isaacson, M., Turner, J. N., & Shain, W. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2004.08.037 · Cited by 215
Flexible Neural Electrode Array Based-on Porous Graphene for Cortical Microstimulation and Sensing
Lu, Y., Lyu, H., Richardson, A. G., Lucas, T. H., & Kuzum, D. (2016) · Scientific Reports · doi:10.1038/srep33526 · Cited by 213
Brain-computer interface technologies: from signal to action
Ortiz-Rosario, A., & Adeli, H. (2013) · Reviews in the Neurosciences · doi:10.1515/revneuro-2013-0032 · Cited by 213
“, 2012), whereas MUA and SU record the action potentials of single neurons (Maynard et al., 1997; Carmena et al., 2003; Collinger et al., 2013).”
BackgroundModeling and Decoding Motor Cortical Activity Using a Switching Kalman Filter
Wu, W., Black, M. J., Mumford, D., Gao, Y., Bienenstock, E., & Donoghue, J. P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826666 · Cited by 213
“I. INTRODUCTION RECENT results have demonstrated the feasibility of con-tinuous neural control of devices such as computer cursors using implanted electrodes [13], [28], [29], [33].”
BackgroundPatil, P. G., Carmena, J. M., Nicolelis, M. A. L., & Turner, D. A. (2004) · Neurosurgery · doi:10.1227/01.neu.0000126872.23715.e5 · Cited by 208
“These designs include silicon-based chip electrodes (20), the neurotrophic electrode (14, 15), and either fixed grid arrays of microwires (23) or loose microwires inserted as a bundle (10, 16).”
BackgroundBiosignal-Based Spoken Communication: A Survey
Schultz, T., Wand, M., Hueber, T., Krusienski, D. J., Herff, C., & Brumberg, J. S. (2017) · IEEE/ACM Transactions on Audio, Speech, and Language Processing · doi:10.1109/taslp.2017.2752365 · Cited by 201
“croelectrodes and microarrays, such as the Utah array [52], provide unparalleled spatial and temporal resolution down to single neuron action potentials.”
BackgroundSilicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194
Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS
Thelin, J., Jörntell, H., Psouni, E., Garwicz, M., Schouenborg, J., Danielsen, N., & Linsmeier, C. E. (2011) · PLoS ONE · doi:10.1371/journal.pone.0016267 · Cited by 191
“Utah electrodes are silicon needles arranged in a two-dimensional format, typically 10610, where the tip of each needle is the electrode site [13,31,32,33,34].”
BackgroundSpike Sorting: The First Step in Decoding the Brain: The first step in decoding the brain
Gibson, S., Judy, J. W., & Markovic, D. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2011.941880 · Cited by 189
Vallabhaneni, A., Wang, T., & He, B. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_3 · Cited by 218
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
“Previous acute recording experiments revealed that seemingly normal neural activity could be recorded minutes after implantation for up to 10 h [19], [ 13 ], suggesting that the vascular supply to the implanted area is not comprised.”
BackgroundSelf-citationNeurotechnologies for Human Cognitive Augmentation: Current State of the Art and Future Prospects
Cinel, C., Valeriani, D., & Poli, R. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00013 · Cited by 178
“Other invasive recording technologies include arrays of needle-shapedmicroelectrodes in the brain (Maynard et al., 1997; Oka et al., 1999).”
BackgroundOn the Variability of Manual Spike Sorting
Wood, F., Black, M. J., Vargas-Irwin, C., Fellows, M., & Donoghue, J. P. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826677 · Cited by 177
“In particular, chronically implanted micro-electrode arrays (such as the Utah intracortical array [18] used in the recordings for the experiment) effectively prohibit both individual electrode placement and simultaneous intra-cellular recording.”
MethodLong-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
“Proposed in the late 1990s, UEA was defined by a hundred needles of silicon, micromachined from bulk silicon [125, 147, 160].”
BackgroundPathobiology of Human Cerebrovascular Malformations: Basic Mechanisms and Clinical Relevance
Gault, J., Sarin, H., Awadallah, N. A., Shenkar, R., & Awad, I. A. (2004) · Neurosurgery · doi:10.1227/01.neu.0000440729.59133.c9 · Cited by 170
Control of a brain–computer interface without spike sorting
Fraser, G. W., Chase, S. M., Whitford, A., & Schwartz, A. B. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/055004 · Cited by 168
Corrosion of tungsten microelectrodes used in neural recording applications
Patrick, E., Orazem, M. E., Sanchez, J. C., & Nishida, T. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.03.012 · Cited by 167
“The electrochemical behavior of tungsten microelectrodes are compared to the behavior of platinum microelectrodes, which are also widely used for neural recording applications and considered inert for such applications (de Haro et al., 2002; Kipke, 2003; Maynard et al., 1997).”
Flexible Electrodes for In Vivo and In Vitro Electrophysiological Signal Recording
Zhu, M., Wang, H., Li, S., Liang, X., Zhang, M., Dai, X., & Zhang, Y. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100646 · Cited by 171
Comparison of brain–computer interface decoding algorithms in open-loop and closed-loop control
Koyama, S., Chase, S. M., Whitford, A. S., Velliste, M., Schwartz, A. B., & Kass, R. E. (2010) · Journal of Computational Neuroscience · doi:10.1007/s10827-009-0196-9 · Cited by 163
“A 96 channel electrode array was implanted in the motor cortex of a monkey to record neural activity (Blackrock Microsystems, Salt Lake City, UT; Maynard and Normann 1997).”
Grahn, P. J., Mallory, G. W., Khurram, O. U., Berry, B. M., Hachmann, J. T., Bieber, A. J., Bennet, K. E., Min, H.-K., Chang, S.-Y., Lee, K. H., et al. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00169 · Cited by 157
“Furthermore, recording can only occur from the tips of the electrodes, limiting recording selectivity (Maynard et al., 1997).”
BackgroundMiranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2044573 · Cited by 161
Mollazadeh, M., Murari, K., Cauwenberghs, G., & Thakor, N. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2005297 · Cited by 160
Rapid calibration of an intracortical brain–computer interface for people with tetraplegia
Brandman, D. M., Hosman, T., Saab, J., Burkhart, M. C., Shanahan, B. E., Ciancibello, J. G., Sarma, A. A., Milstein, D. J., Vargas-Irwin, C. E., Franco, B., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9ee7 · Cited by 153
Neural Decoding of Cursor Motion Using a Kalman Filter
Wu, W. L., Black, M. J., Gao, Y., Bienenstock, E., Serruya, M. D., Shaikhouni, A., & Donoghue, J. P. (2003) · Cited by 156
Imaging fast electrical activity in the brain with electrical impedance tomography
Aristovich, K. Y., Packham, B., Koo, H., dos Santos, G. S., McEvoy, A., & Holder, D. S. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.071 · Cited by 165
“Contents lists available at ScienceDirect NeuroImage j ourna l homepage: www.e lsev ie r .com/ locate /yn img Imaging fast electrical activity in the brain with electrical impedance tomography Kirill Y. Aristovich a,1, Brett C. Packham a,1, Hwan Koo a, Gustavo Sato dos Santos a, Andy McEvoy b, David S. Holder a a Depa…”
BackgroundMethodInfluentialHow many neurons can we see with current spike sorting algorithms?
Pedreira, C., Martinez, J., Ison, M. J., & Quiroga, R. Q. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.07.010 · Cited by 162
Kapoor, V., Dwarakanath, A., Safavi, S., Werner, J., Besserve, M., Panagiotaropoulos, T. I., & Logothetis, N. K. (2022) · Nature Communications · doi:10.1038/s41467-022-28897-2 · Cited by 111
Recording from the same neurons chronically in motor cortex
Fraser, G. W., & Schwartz, A. B. (2012) · Journal of Neurophysiology · doi:10.1152/jn.01012.2010 · Cited by 147
“Two male rhesus macaques were implanted with 96-channel microelectrode arrays (Blackrock Microsystems; Maynard et al. 1997).”
MethodSilent Speech Interfaces for Speech Restoration: A Review
González, J. A., Gomez-Alanis, A., Martín-Doñas, J. M., Pérez-Córdoba, J. L., & Gomez, A. M. (2020) · IEEE Access · doi:10.1109/access.2020.3026579 · Cited by 188
A Low-Power 32-Channel Digitally Programmable Neural Recording Integrated Circuit
Wattanapanitch, W., & Sarpeshkar, R. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2163404 · Cited by 146
“With the aid of high-density microelectrode arrays, neural activities from a large population of neurons can be observed simultaneously with a spatial resolution down to that of a single cell [1], [2].”
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
Piret, G., Hébert, C., Mazellier, J.-P., Rousseau, L., Scorsone, E., Cottance, M., Lissorgues, G., Heuschkel, M. O., Picaud, S., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.021 · Cited by 135
Hébert, C., Masvidal‐Codina, E., Suarez‐Perez, A., Calia, A. B., Piret, G., Garcia‐Cortadella, R., Illa, X., del Corro, E., de la Cruz, J. M., Viana, D., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703976 · Cited by 150
HermesB: A Continuous Neural Recording System for Freely Behaving Primates
Santhanam, G., Linderman, M. D., Gilja, V., Afshar, A., Ryu, S. I., Meng, T. H., & Shenoy, K. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895753 · Cited by 136
A floating metal microelectrode array for chronic implantation
Musallam, S., Bak, M. J., Troyk, P. R., & Andersen, R. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.09.005 · Cited by 149
Large-scale high-density brain-wide neural recording in nonhuman primates
Trautmann, E. M., Hesse, J. K., Stine, G. M., Xia, R., Zhu, S., O’Shea, D. J., Karsh, B., Colonell, J. I., Lanfranchi, F. F., Vyas, S., et al. (2025) · Nature Neuroscience · doi:10.1038/s41593-025-01976-5 · Cited by 150
“…populations of superficial neurons in gyral motor cortex (PMd and rostral M1) using Utah arrays 31 and, alternatively, recording fewer neurons in sulcal M1 using single-wire electrodes or passive arrays of 16–32 contacts (for example, Plexon S-probes or Microprobes Floating Microwire Arrays 17 ).”
Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Tchoe, Y., Bourhis, A. M., Cleary, D. R., Stedelin, B., Lee, J., Tonsfeldt, K. J., Brown, E. C., Siler, D. A., Paulk, A. C., Yang, J. C., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj1441 · Cited by 135
Otto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 131
“developed devices that are capable of recording from dozens of neurons for time periods of weeks to months [1]–[5].”
BackgroundCurrent trends in hardware and software for brain–computer interfaces (BCIs)
Brunner, P., Bianchi, L., Guger, C., Cincotti, F., & Schalk, G. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025001 · Cited by 127
Brain Machine Interfaces for Vision Restoration: The Current State of Cortical Visual Prosthetics
Niketeghad, S., & Pouratian, N. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0660-1 · Cited by 136
Emerging SiC Applications beyond Power Electronic Devices
Via, F. L., Alquier, D., Giannazzo, F., Kimoto, T., Neudeck, P. G., Ou, H., Roncaglia, A., Saddow, S. E., & Tudisco, S. S. (2023) · Micromachines · doi:10.3390/mi14061200 · Cited by 138
High-density single-unit human cortical recordings using the Neuropixels probe
Chung, J. E., Sellers, K. K., Leonard, M. K., Gwilliams, L., Xu, D., Dougherty, M. E., Kharazia, V., Metzger, S. L., Welkenhuysen, M., Dutta, B., et al. (2022) · Neuron · doi:10.1016/j.neuron.2022.05.007 · Cited by 126
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Soft electrodes combining hydrogel and liquid metal
Shay, T., Velev, O. D., & Dickey, M. D. (2018) · Soft Matter · doi:10.1039/c8sm00337h · Cited by 128
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Multielectrode approaches (12, 13) provided early examples of real-time prediction of an animal’s wrist position from the decoded motor cortex output (14, 15) and enabled animals to perform simple tasks via an external device (16).”
Recent advances in bioelectronics chemistry
Fang, Y., Meng, L., Promiński, A., Schaumann, E. N., Seebald, M., & Tian, B. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00333f · Cited by 123
Sensor Modalities for Brain-Computer Interface Technology: A Comprehensive Literature Review
Martini, M. L., Oermann, E. K., Opie, N. L., Panov, F. E., Oxley, T. J., & Yaeger, K. (2019) · Neurosurgery · doi:10.1093/neuros/nyz286 · Cited by 133
A comprehensive assessment of Brain Computer Interfaces: Recent trends and challenges
Yadav, D., Yadav, S., & Veer, K. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108918 · Cited by 133
Sensors for brain-computer interfaces
Hochberg, L. R., & Donoghue, J. P. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705745 · Cited by 115
“Based upon work conducted in the Donoghue laboratory [46], [55], and following eight years of device development and testing in monkeys, a 4 mm × 4 mm sensory (array) of 100 silicon microelectrodes ([35], Cyberkinetics, Inc.”
BackgroundMethodRobustness of neuroprosthetic decoding algorithms
Serruya, M. D., Fellows, M. R., Paninski, L., Donoghue, J. P., & Hatsopoulos, N. G. (2003) · Biological Cybernetics · doi:10.1007/s00422-002-0374-6 · Cited by 125
“Although long-term recording of multiple neurons presents formidable technical challenges, there have been a number of significant recent successes in advancing this technology, making possible its adoption for use in neural prosthetics ( Maynard et al. 1997, 2000; Williams et al. 1999).”
BackgroundMethodThin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118
Spatial Filtering for EEG-Based Regression Problems in Brain–Computer Interface (BCI)
Wu, D., King, J.-T., Chuang, C.-H., Lin, C.-T., & Jung, T.-P. (2018) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2017.2688423 · Cited by 116
Perelman, Y., & Ginosar, R. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883732 · Cited by 116
“VAILABILITY of multisite neuronal electrodes, such as the Michigan probe [1] or the Utah array [ 2 ], has enabled the development of highly integrated multichannel recording devices with large channel counts.”
Xiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116
Brumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
“Currently, the only microelectrodes for use in human studies are the Utah, or NeuroPort array (Jones et al., 1992; Maynard et al., 1997; Hochberg et al., 2006; Donoghue et al., 2007) and Neurotrophic Electrode (Kennedy, 1989; Kennedy et al., 1992a; Kennedy and Bakay, 1998).”
The Potential for a Speech Brain–Computer Interface Using Chronic Electrocorticography
Rabbani, Q., Milsap, G., & Crone, N. E. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00692-2 · Cited by 120
Cho, M., Han, J.-K., Suh, J., Kim, J. J., Ryu, J. R., Min, I. S., Sang, M., Lim, S., Kim, T. S., Kim, K., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-45803-0 · Cited by 114
Advances in Soft Bioelectronics for Brain Research and Clinical Neuroengineering
Sunwoo, S., Han, S. I., Joo, H., Cha, G. D., Kim, D., Choi, S. H., Hyeon, T., & Kim, D. (2020) · Matter · doi:10.1016/j.matt.2020.10.020 · Cited by 114
Propagating waves in thalamus, cortex and the thalamocortical system: Experiments and models
Muller, L., & Destexhe, A. (2012) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2012.06.005 · Cited by 112
“The possibility of coherent propagating activity was first raised by VSD, MEA, and intracellular studies in vitro.”
InfluentialCMU Array: A 3D nanoprinted, fully customizable high-density microelectrode array platform
Saleh, M. S., Ritchie, S. M., Nicholas, M. A., Gordon, H. L., Hu, C., Jahan, S., Yuan, B., Bezbaruah, R., Reddy, J. W., Ahmed, Z., et al. (2022) · Science Advances · doi:10.1126/sciadv.abj4853 · Cited by 112
A micromachined silicon depth probe for multichannel neural recording
Yoon, T. H., Hwang, E. J., Shin, D. Y., Park, S. I., Oh, S. J., Jung, S. C., Shin, H. C., & Kim, S. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.855936 · Cited by 110
Parallel, minimally-invasive implantation of ultra-flexible neural electrode arrays
Zhao, Z., Li, X., He, F., Wei, X., Lin, S. Q., & Xie, C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab05b6 · Cited by 110
“The smallest inter-shank spacing we demonstrated using the microtrenches guided microwire arrays was 150 μm, which is comparable to the closest spaced silicon neural probes [38, 40] and Utah arrays [38].”
Method
Metadata
- Authors
- Maynard, E. M., Nordhausen, C. T., & Normann, R. A.
- Affiliations
- University of Utah (US)
- Corresponding author
- Normann, Richard A.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1997-03
- Volume
- 102
- Issue
- 3
- Pages
- 228-239
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2020769260
- Semantic Scholar
- 8c017a2d9f35afc32fabba0f5b65a52191c82682
- Cited by
- 640
- References
- 37
- Citations by year
- 2026: 20 · 2025: 48 · 2024: 34 · 2023: 39 · 2022: 35 · 2021: 34 · 2020: 26 · 2019: 27 · 2018: 31 · 2017: 41 · 2016: 29 · 2015: 22 · 2014: 26 · 2013: 18 · 2012: 22
- FWCI
- 3.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Electroencephalography and Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Keywords
- brain-computer interface, intracortical microelectrode arrays, signal-to-noise ratio, stimulus detection, neural decoding
- MeSH terms
- Action Potentials, Animals, Brain, Cats, Computers, Microelectrodes, Neurons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.