A study of dipole localization accuracy for MEG and EEG using a human skull phantom
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Golub, G. (2012) · doi:10.56021/9781421407944 · Cited by 34,505
Rapid Automated Algorithm for Aligning and Reslicing PET Images
Woods, R. P., Cherry, S. R., & Mazziotta, J. C. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00024 · Cited by 1,912
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Multiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationRealistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 1×
“Instabilities due to the large conductivity differences between brain and skull were minimized using the isolated skull approach of (Hämäläinen and Sarvas 1989).”
MethodRecursive MUSIC: A framework for EEG and MEG source localization
Mosher, J. C., & Leahy, R. M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.725331 · Cited by 362
Self-citationMEG versus EEG localization test using implanted sources in the human brain
Cohen, D., Cuffin, B. N., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J., Kennedy, J. G., & Schomer, D. L. (1990) · Annals of Neurology · doi:10.1002/ana.410280613 · Cited by 294
Error bounds for EEG and MEG dipole source localization
Mosher, J. C., Spencer, M. E., Leahy, R. M., & Lewis, P. S. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90043-u · Cited by 233
Self-citationStudies in the Robustness of Multidimensional Scaling: Procrustes Statistics
Sibson, R. (1978) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1978.tb01669.x · Cited by 195
Zhang, Z. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/3/001 · Cited by 192
Cited by
Brainstorm: A User-Friendly Application for MEG/EEG Analysis
Tadel, F., Baillet, S., Mosher, J. C., Pantazis, D., & Leahy, R. M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/879716 · Cited by 3,677
Self-citationBaillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationMagnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
A sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG
Huang, M. X., Mosher, J. C., & Leahy, R. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/2/010 · Cited by 612
Self-citationReview on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
Nunez, P. L., Wingeier, B. M., & Silberstein, R. B. (2001) · Human Brain Mapping · doi:10.1002/hbm.1030 · Cited by 510
A Quantitative Assessment of the Sensitivity of Whole-Head MEG to Activity in the Adult Human Cortex
Hillebrand, A., & Barnes, G. R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1102 · Cited by 428
A common formalism for the Integral formulations of the forward EEG problem
Kybic, J., Clerc, M., Abboud, T., Faugeras, O., Keriven, R., & Papadopoulo, T. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.837363 · Cited by 422
MEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Oostenveld, R., & Oostendorp, T. F. (2002) · Human Brain Mapping · doi:10.1002/hbm.10061 · Cited by 368
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349
Lithari, C., Frantzidis, C. A., Papadelis, C., Vivas, A. B., Klados, M. A., Kourtidou-Papadeli, C., Pappas, C., Ioannides, A. A., & Bamidis, P. D. (2010) · Brain Topography · doi:10.1007/s10548-009-0130-5 · Cited by 311
Mapping human brain function with MEG and EEG: methods and validation
Darvas, F., Pantazis, D., Kucukaltun-Yildirim, E., & Leahy, R. M. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.014 · Cited by 310
Self-citationNunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Goldenholz, D. M., Ahlfors, S. P., Hämäläinen, M. S., Sharon, D., Ishitobi, M., Vaina, L. M., & Stufflebeam, S. M. (2009) · Human Brain Mapping · doi:10.1002/hbm.20571 · Cited by 266
The neurophysiological bases of EEG and EEG measurement: A review for the rest of us
Jackson, A. F., & Bolger, D. J. (2014) · Psychophysiology · doi:10.1111/psyp.12283 · Cited by 264
Dien, J., Spencer, K. M., & Donchin, E. (2003) · Cognitive Brain Research · doi:10.1016/s0926-6410(03)00188-5 · Cited by 262
Huang, Y., Parra, L. C., & Haufe, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.12.019 · Cited by 259
Dynamic causal modelling of evoked responses in EEG/MEG with lead field parameterization
Kiebel, S. J., David, O., & Friston, K. J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.055 · Cited by 233
“However, note that dipole models for MEG are seen, with respect to localization error, as an adequate alternative to realistic boundary element methods (Darvas et al., 2004; Leahy et al., 1998).”
Huang, M.-X., Theilmann, R. J., Robb, A., Angeles, A., Nichols, S., Drake, A., D'Andrea, J., Levy, M., Holland, M., Song, T., et al. (2009) · Journal of Neurotrauma · doi:10.1089/neu.2008.0672 · Cited by 225
“MEG is a non-invasive functional imaging technique that directly measures the magnetic signal due to neuronal activation with high temporal resolution ( 1 ms) and spatial localization accuracy (2–3mm) (Leahy et al., 1998).”
Self-citationGoncalves, S. I., de Munck, J. C., Verbunt, J. P. A., Bijma, F., Heethaar, R. M., & Lopes da Silva, F. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812164 · Cited by 219
MEG/EEG Group Analysis With Brainstorm
Tadel, F., Bock, E., Niso, G., Mosher, J. C., Cousineau, M., Pantazis, D., Leahy, R. M., & Baillet, S. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00076 · Cited by 218
“…Boundary Element Models (BEMs) based on individual tessellations of segmented head compartments 24 and fast, analytical approximations of the head geometry with multiple nested spheres, where these spheres can also be locally fitted separately to each sensor (Leahy et al., 1998; Huang et al., 1999).”
BackgroundSelf-citationDatta, A., Bikson, M., & Fregni, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.04.252 · Cited by 211
“Because of the critical dependence on material properties (tissue electrical conductivity) and brain skin/brain anatomy, reduced phantoms are of limited use in predicting cortical current flow (Rush and Driscoll, 1968; Leahy et al., 1998).”
BackgroundBarkley, G. L., & Baumgartner, C. (2003) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200305000-00002 · Cited by 202
“Phantom studies reported localization accuracies of 7 to 8 mm for the EEG and of 2 to 4 mm for the MEG (Gharib et al., 1995; Leahy et al., 1998; Yamamoto et al., 1988).”
BackgroundMethodMicrotesla MRI of the human brain combined with MEG
Zotev, V. S., Matlashov, A. N., Volegov, P. L., Savukov, I. M., Espy, M. A., Mosher, J. C., Gomez, J. J., & Kraus, R. H. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.06.007 · Cited by 175
“Typical MEG/MRI co-registration errors of the order of 510 mm [13] exceed average MEG source localization errors [14] and make MEG less efficient as a clinical evaluation tool.”
MethodSelf-citationCanonical Source Reconstruction for MEG
Mattout, J., Henson, R. N., & Friston, K. J. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/67613 · Cited by 159
“In other words, each source, comprising the mesh, has a predetermined and unique anatomical attribution within standard stereotactic space.”
BackgroundThe Human Neural Alpha Response to Speech is a Proxy of Attentional Control
Wöstmann, M., Lim, S.-J., & Obleser, J. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx074 · Cited by 141
An alternative subspace approach to EEG dipole source localization
Xu, X.-L., Xu, B., & He, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/2/010 · Cited by 73
Paired MEG data set source localization using recursively applied and projected (RAP) MUSIC
Ermer, J. J., Mosher, J. C., Huang, M., & Leahy, R. M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867959 · Cited by 64
Self-citationDien, J., Brian, E. S., Molfese, D. L., & Gold, B. T. (2013) · Cortex · doi:10.1016/j.cortex.2013.03.008 · Cited by 59
Bögels, S., Casillas, M., & Levinson, S. C. (2018) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2017.12.028 · Cited by 55
“The reason for this is unclear but we must keep in mind that localization of EEG data can be difficult (see, e.g., Leahy et al., 1998), especially if a standard head model is used, as in the present study.”
Method(2015) · Europe PMC (PubMed Central) · Cited by 51
Investigating the Effects of Chiropractic Spinal Manipulation on EEG in Stroke Patients
Navid, M. S., Niazi, I. K., Lelic, D., Nedergaard, R. B., Holt, K., Amjad, I., Drewes, A. M., & Haavik, H. (2020) · Brain Sciences · doi:10.3390/brainsci10050253 · Cited by 18
Metadata
- Authors
- Leahy, R. M., Mosher, J. C., Spencer, M. E., Huang, M. X., & Lewine, J. D.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1998-04
- Volume
- 107
- Issue
- 2
- Pages
- 159-173
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2092260964
- Cited by
- 383
- References
- 17
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.