The role of elastin in aortic valve mechanics
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
THE REASON FOR THE SHAPE OF THE DISTENSIBILITY CURVES OF ARTERIES
Roach, M. R., & Burton, A. C. (1957) · Canadian Journal of Biochemistry and Physiology · doi:10.1139/o57-080 · Cited by 790
Topographic Anatomy and Histology of the Valves in the Human Heart.
Gross, L., & Kügel, M. (1931) · Europe PMC (PubMed Central) · Cited by 317
The role of elastin in the mechanical properties of skin
Oxlund, H., Manschot, J., & Viidik, A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90172-8 · Cited by 235
Micromechanics of the fibrosa and the ventricularis in aortic valve leaflets
Vesely, I., & Noseworthy, R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90249-z · Cited by 200
Self-citationAortic valve cusp microstructure: The role of elastin
Scott, M., & Veselý, I. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00263-k · Cited by 137
Age-Related Collagen and Elastin Content of Human Heart Valves
Bashey, R. I., Torii, S., & ANGRIST, A. A. (1967) · Journal of Gerontology · doi:10.1093/geronj/22.2.203 · Cited by 115
Veselý, I., & Boughner, D. R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90016-x · Cited by 113
Morphology of porcine aortic valve cusp elastin.
Mj, S., & Veselý, I. (1996) · PubMed · Cited by 68
Veselý, I., & Lozon, A. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90043-e · Cited by 45
Cited by
Effects of extracellular matrix viscoelasticity on cellular behaviour
Chaudhuri, O., Cooper-White, J., Janmey, P. A., Mooney, D. J., & Shenoy, V. B. (2020) · Nature · doi:10.1038/s41586-020-2612-2 · Cited by 2,224
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Tissue heart valves: Current challenges and future research perspectives
Schoen, F. J., & Levy, R. J. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(19991215)47:4<439::aid-jbm1>3.0.co;2-o · Cited by 498
Heart Valve Structure and Function in Development and Disease
Hinton, R. B., & Yutzey, K. E. (2011) · Annual Review of Physiology · doi:10.1146/annurev-physiol-012110-142145 · Cited by 498
Extracellular Matrix Remodeling and Organization in Developing and Diseased Aortic Valves
Hinton, R. B., Lincoln, J., Deutsch, G. H., Osinska, H., Manning, P. B., Benson, D. W., & Yutzey, K. E. (2006) · Circulation Research · doi:10.1161/01.res.0000224114.65109.4e · Cited by 448
Heart valve function: a biomechanical perspective
Sacks, M. S., & Yoganathan, A. P. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2122 · Cited by 387
On the biomechanics of heart valve function
Sacks, M. S., David Merryman, W., & Schmidt, D. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.015 · Cited by 372
Aortic Valve Stenosis: From Basic Mechanisms to Novel Therapeutic Targets
Goody, P. R., Hosen, M. R., Christmann, D., Niepmann, S. T., Zietzer, A., Adam, M., Bönner, F., Zimmer, S., Nickenig, G., & Jansen, F. (2020) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.119.313067 · Cited by 331
Heart Valve Tissue Engineering
Vesely, I. (2005) · Circulation Research · doi:10.1161/01.res.0000185326.04010.9f · Cited by 309
Self-citationElastic fiber production in cardiovascular tissue-equivalents
Long, J. L., & Tranquillo, R. T. (2003) · Matrix Biology · doi:10.1016/s0945-053x(03)00052-0 · Cited by 283
Biomechanical properties of native and tissue engineered heart valve constructs
Hasan, A., Ragaert, K., Swieszkowski, W., Selimović, Š., Paul, A., Camci-Unal, G., Mofrad, M. R. K., & Khademhosseini, A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.023 · Cited by 279
Kluin, J., Talacua, H., Smits, A. I. P. M., Emmert, M. Y., Brugmans, M. C. P., Fioretta, E. S., Dijkman, P. E., Söntjens, S. H. M., Duijvelshoff, R., Dekker, S., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.007 · Cited by 268
GRAUSS, R., HAZEKAMP, M., OPPENHUIZEN, F., VANMUNSTEREN, C., GITTENBERGERDEGROOT, A., & DERUITER, M. (2005) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2004.12.052 · Cited by 259
Heart valve macro- and microstructure
Misfeld, M., & Sievers, H.-H. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2125 · Cited by 254
Lincoln, J., Lange, A. W., & Yutzey, K. E. (2006) · Developmental Biology · doi:10.1016/j.ydbio.2006.03.027 · Cited by 231
Biologically Inspired Scaffolds for Heart Valve Tissue Engineering via Melt Electrowriting
Saidy, N. T., Wolf, F., Bas, O., Keijdener, H., Hutmacher, D. W., Mela, P., & De‐Juan‐Pardo, E. M. (2019) · Small · doi:10.1002/smll.201900873 · Cited by 215
On the Biaxial Mechanical Properties of the Layers of the Aortic Valve Leaflet
Stella, J. A., & Sacks, M. S. (2007) · Journal of Biomechanical Engineering · doi:10.1115/1.2768111 · Cited by 212
Aortic valve disease and treatment: The need for naturally engineered solutions
Butcher, J. T., Mahler, G. J., & Hockaday, L. A. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.008 · Cited by 210
“The thinner ventricularis covers the ventricular surface of the leaflet, and has considerably more elastin than the fibrosa, but both components are organized with somewhat less directionality than in the fibrosa when fully relaxed [6].”
BackgroundBalguid, A., Rubbens, M. P., Mol, A., Bank, R. A., Bogers, A. J. J. C., van Kats, J. P., de Mol, B. A. J. M., Baaijens, F. P. T., & Bouten, C. V. C. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0279 · Cited by 197
“19,20 Because of species differences, extrapolation of such results to human valves is problematic.”
Toughening Hydrogels with Fibrillar Connected Double Networks
Fang, Y., Liang, C., Liljeström, V., Lv, Z., Ikkala, O., & Zhang, H. (2024) · Advanced Materials · doi:10.1002/adma.202402282 · Cited by 181
Elastic materials for tissue engineering applications: Natural, synthetic, and hybrid polymers
Coenen, A. M. J., Bernaerts, K. V., Harings, J. A. W., Jockenhoevel, S., & Ghazanfari, S. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.027 · Cited by 180
“Consequently, the fracture tension of the elastin fibers in the circumferential and radial directions, respectively, was 0.35 and 0.14 Nm (cid:1) 1 for the fibrosa and 2.94 and 2.81 Nm -1 for the ventricu-laris [56].”
BackgroundInfluentialThe mechanical behavior of skin: Structures and models for the finite element analysis
Benítez, J. M., & Montáns, F. J. (2017) · Computers & Structures · doi:10.1016/j.compstruc.2017.05.003 · Cited by 162
Co-ordinating Notch, BMP, and TGF-β signaling during heart valve development
Garside, V. C., Chang, A. C., Karsan, A., & Hoodless, P. A. (2013) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-012-1197-9 · Cited by 160
Elastin-like protein matrix reinforced with collagen microfibers for soft tissue repair
Caves, J. M., Cui, W., Wen, J., Kumar, V. A., Haller, C. A., & Chaikof, E. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.009 · Cited by 97
“In many instances, including blood vessels [3], heart valve leaflets [4], and dermis [5], the arrangement and structure of elastin and collagen jointly determine biomechanical properties.”
Wong, M. L., Wong, J. L., Athanasiou, K. A., & Griffiths, L. G. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.12.034 · Cited by 65
“In aortic valve leaflets, elastin fibers maintain leaflet structure–function properties by facilitating changes in collagen fiber configuration throughout the cardiac cycle [34].”
BackgroundAntigen removal for the production of biomechanically functional, xenogeneic tissue grafts
Cissell, D. D., Hu, J. C., Griffiths, L. G., & Athanasiou, K. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.10.041 · Cited by 52
“In heart valves, elastin contributes tensile stiffness at low strains (Vesely, 1998).”
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Future prospects in the tissue engineering of heart valves: a focus on the role of stem cells
Albert, B. J., & Butcher, J. T. (2023) · Expert Opinion on Biological Therapy · doi:10.1080/14712598.2023.2214313 · Cited by 8
Metadata
- Authors
- Vesely, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1997-05
- Volume
- 31
- Issue
- 2
- Pages
- 115-123
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2108819369
- Cited by
- 265
- References
- 11
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.