The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques
The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Abstract
Acoustic microscopy (30-60 microm resolution) and nanoindentation (1-5 microm resolution) are techniques that can be used to evaluate the elastic properties of human bone at a microstructural level. The goals of the current study were (1) to measure and compare the Young's moduli of trabecular and cortical bone tissues from a common human donor, and (2) to compare the Young's moduli of bone tissue measured using acoustic microscopy to those measured using nanoindentation. The Young's modulus of cortical bone in the longitudinal direction was about 40% greater than (p<0.01) the Young's modulus in the transverse direction. The Young's modulus of trabecular bone tissue was slightly higher than the transverse Young's modulus of cortical bone, but substantially lower than the longitudinal Young's modulus of cortical bone. These findings were consistent for both measurement methods and suggest that elasticity of trabecular tissue is within the range of that of cortical bone tissue. The calculation of Young's modulus using nanoindentation assumes that the material is elastically isotropic. The current results, i.e., the average anisotropy ratio (E(L)/E(T)) for cortical bone determined by nanoindentation was similar to that determined by the acoustic microscope, suggest that this assumption does not limit nanoindentation as a technique for measurement of Young's modulus in anisotropic bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [138]
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Self-citationA method for interpreting the data from depth-sensing indentation instruments
Doerner, M. F., & Nix, W. D. (1986) · Journal of Materials Research · doi:10.1557/jmr.1986.0601 · Cited by 2,863
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Self-citationMeasurement of Thin Film Mechanical Properties Using Nanoindentation
Pharr, G. M., & Oliver, W. C. (1992) · MRS Bulletin · doi:10.1557/s0883769400041634 · Cited by 1,012
Self-citationElastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Self-citationA continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citationComposition of trabecular and cortical bone
Gong, J. K., Arnold, J. S., & Cohn, S. H. (1964) · The Anatomical Record · doi:10.1002/ar.1091490303 · Cited by 308
Research works printed but not linked: 2
- Ko, C.C., Douglas, W.H., Cheng, Y.S., 1995. Intrinsic mechanical competence of cortical and trabecular bone measured by nanoindentation and microindentation probes. 1995 ASME Bioengineering Conference, ASME BED-Vol. 29, pp. 415–416.
- Runkle, 1975, The micro-mechanics of cancellous bone, Bulletin of the Hospital for Joint Diseases, 36, 2
Cited by
Items 401–500 of 651
Stress development at human femur by muscle forces
Kenedi, P. P., & Riagusoff, I. I. T. (2014) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-014-0164-9 · Cited by 5
The Effect of Age on Material Properties
Allen, M. R., Burr, D. B., & Turner, C. H. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-374602-3.00018-3 · Cited by 5
Self-citationIngle, D. N., & Porter, M. E. (2020) · Journal of Experimental Biology · doi:10.1242/jeb.213009 · Cited by 5
Influence de l’hétérogénéité des propriétés mécaniques sur la résistance de l’os trabéculaire humain
Dépalle, B. (2011) · theses.fr (ABES) · doi:10.70675/bf4d472cz0dd4z4d20za7f2zd8806f663dd6 · Cited by 5
Microscopic Approach for Testing Mechanical Properties of Hard Tissues
Marrese, M., Guarino, V., & Ambrosio, L. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.02260-8 · Cited by 5
Gefen, A., & Neulander, R. (2007) · Journal of Applied Biomechanics · doi:10.1123/jab.23.3.230 · Cited by 5
Tensile Response Characterization and Constitutive Modeling of LPBF Ti6Al4V Thin Struts
Hosseini, E., Robmann, S., Lüthi, T., Affolter, C., & Mazza, E. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202201135 · Cited by 5
A finite element modelling strategy for suture anchor devices
Hughes, C. C. W. (2014) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 5
Evaluation of the Surface Referencing Technique in Depth‐Sensing Indentation of Soft Materials
Tang, B. H., & Ngan, A. H. W. (2004) · Soft Materials · doi:10.1081/smts-200065881 · Cited by 5
Stochastically generated finite element beam model for dental research
Lakatos, É. I., & Bojtár, I. (2009) · Periodica Polytechnica Civil Engineering · doi:10.3311/pp.ci.2009-1.01 · Cited by 5
Fojt, J., Joska, L., & Hnilica, F. (2013) · Kovove Materialy-Metallic Materials · doi:10.4149/km_2012_5_335 · Cited by 5
Microscale’s relationship between Young’s modulus and tissue density. Prediction of displacements
Cyganik, Ł., Binkowski, M., Kokot, G., Cyganik, P., Rusin, T., Bolechała, F., Nowak, R., Wróbel, Z., & John, A. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1404993 · Cited by 5
Nanoindentation and Indentation Size Effects: Continuum Model and Atomistic Simulation
Yu, C., Lin, K., & Chen, C. (2019) · Springer eBooks · doi:10.1007/978-981-10-6884-3_26 · Cited by 5
Hellmich, C., & Kober, C. (2006) · PAMM · doi:10.1002/pamm.200610019 · Cited by 5
Follet, H., & Rumelhart, C. (2002) · HAL · Cited by 5
Synthesis and characterization of calcium phosphate cement based macroporous scaffolds
Şahin, E. (2012) · IYTE GCRIS Database (Izmir Institute of Technology) · Cited by 5
Ultrasonic Characterization of Hard Tissues
Raum, K. (2003) · CRC Press eBooks · doi:10.1201/9780203501962.ch13 · Cited by 5
Jiang, X., Yao, Y., Tang, W., Han, D., Zhang, L., Zhao, K., Wang, S., & Meng, Y. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01254 · Cited by 4
Matsuki, H., SHIBANO, J.-I., KOBAYASHI, M., Nakatsuchi, Y., Moriizumi, T., & Kato, H. (2015) · Journal of Medical Ultrasonics · doi:10.1007/s10396-014-0608-y · Cited by 4
MICROSTRUCTURAL STRESSES AND STRAINS ASSOCIATED WITH TRABECULAR BONE MICRODAMAGE
Nagaraja, S. (2006) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 4
Adams, G. J. (2017) · CERES (Cranfield University) · Cited by 4
Quaytman, J., David, N. L., Venugopal, S., Amorim, T., Beatrice, B., Toledo, F. G. S., Miller, R. G., Steinhauser, M. L., & Fazeli, P. K. (2024) · Contemporary Clinical Trials · doi:10.1016/j.cct.2024.107698 · Cited by 4
On-site SEM and nanomechanical properties of human OI bone
Gu, C., Katti, D. R., & Katti, K. S. (2016) · Bioinspired Biomimetic and Nanobiomaterials · doi:10.1680/jbibn.15.00008 · Cited by 4
Jaramillo-Isaza, S. (2014) · theses.fr (ABES) · doi:10.70675/1e99ae4bz4f82z443fza039z00b525230143 · Cited by 4
Mechanical Degradation Model of Porous Fe Scaffold: Simulation Approach
Prakoso, A. T., Ichsan, A. R., Syahrom, A., Saad, A. P. M., Wahab, A. H. A., Sulong, M. A., Ghazali, F. A. M., & Basri, H. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1500/1/012023 · Cited by 4
Orthotropic modelling of the skeletal system
Geraldes, D. M. (2012) · Spiral (Imperial College London) · doi:10.25560/13813 · Cited by 4
Non-invasive Bone Quality Assessment Using Quantitative Ultrasound Imaging and Acoustic Parameters
Qin, Y., Lin, W., Xia, Y., Mittra, E., Rubin, C., & Müller, R. (2007) · Springer eBooks · doi:10.1007/978-3-540-45456-4_7 · Cited by 4
Etienne, C. (2023) · theses.fr (ABES) · doi:10.70675/d81ce738z7ca8z4051z9b41zbf5ccade2086 · Cited by 4
Current Mechanical Test Methodologies
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2_3 · Cited by 4
Micro-computed tomography studies of biomaterials and bone
Jones, A. C. (2008) · ANU Open Research (Australian National University) · doi:10.25911/5d78dcf139dfd · Cited by 4
Computation of flexural properties of HA/PLLA composite using a cell model approach
Fan, J., Tang, C. Y., & Tsui, C. P. (2006) · Acta Mechanica Solida Sinica · doi:10.1007/s10338-006-0603-y · Cited by 4
STRAIN-STRESS ANALYSIS OF PATHOLOGICAL HIP JOINT AFTER OSTEOTOMY
Návrat, T., Vrbka, M., Florián, Z., & Rozkydal, Z. (2008) · Digitalni Knihovna - Knihovna Akademie věd ČR · Cited by 4
Liu, S., Wang, F., & Liu, R. (2015) · Applied Mathematics and Mechanics · doi:10.1007/s10483-015-1932-7 · Cited by 4
SIMULATION BY FINITE ELEMENTS OF BONE REMODELING AFTER IMPLANTATION OF FEMORAL STEMS
Gracia, L., Ibarz, E., Cegoino, J., Lobo-Escolar, A., Gabarre, S., Puértolas, S., Lpez, E., Mateo, J., & Herrer, A. (2012) · InTech eBooks · doi:10.5772/38546 · Cited by 4
Troedhan, A. C., Kurrek, A., Wainwright, M., & Schlichting, I. (2015) · Open Journal of Stomatology · doi:10.4236/ojst.2015.57022 · Cited by 4
Wykorzystanie fal ultradźwiękowych do oceny zmian struktury kości gąbczastej
Litniewski, J. (2006) · Cited by 4
Comparative sintering of zirconia and hydroxyapatite-zirconia composites
Reidy, C. J. (2010) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/4571 · Cited by 4
Idealization of functionally graded porous tubes for buckling modelling of bone structures
Nokkaew, N., & Eiadtrong, S. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e11580 · Cited by 3
Direct ink writing of bone-specific implantable scaffolds and devices
Dutta, S. D., & Lim, K. (2026) · Progress in Materials Science · doi:10.1016/j.pmatsci.2026.101796 · Cited by 3
Indentation experiments and simulation of ovine bone using a viscoelastic-plastic damage model
Zhao, Y., Wu, Z., Turner, S., MacLeay, J. M., Niebur, G. L., & Ovaert, T. C. (2011) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2011.357 · Cited by 3
Bettamer, A., & Hambli, R. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.04017-0 · Cited by 3
Preclinical biomechanics of a new intramedullary nail for femoral diaphyseal fractures
Ivanov, D. V., Barabash, A., & Barabash, Y. (2015) · Russian Open Medical Journal · doi:10.15275/rusomj.2015.0205 · Cited by 3
Caractérisation multi-échelle du tissu osseux : Application à l'ostéogénèse imparfaite
Echard, A. (2017) · theses.fr (ABES) · doi:10.70675/55a44400z9ff4z465dzb707z3b751f371d81 · Cited by 3
Hengsberger, S. (2002) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-2538 · Cited by 3
The impact and deformation of press-fit metal acetabular components
Hothi, H. S. (2012) · Cited by 3
Rossi, M. C., Escuder, Á. V., Panadero, R. A., Pólo, M. G., Peñalver, P., & Borrás, V. A. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1005426 · Cited by 3
Vandenbulcke, F. (2015) · theses.fr (ABES) · doi:10.70675/9ae64b86z0059z428eza257z7ab6f1018c8f · Cited by 3
Deering, J., Presas, A., Yu, B., Valentín, D., Heiß, C., Bosbach, W. A., & Grandfield, K. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112070 · Cited by 3
Ünal, M. (2017) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 3
Echevarria, E. A. B. (2013) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.58.2013.tde-10092013-094737 · Cited by 3
Lau, M.-L., Lau, K.-T., Ku, H. S., Bahattacharyya, D., & Yao, Y.-D. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.31014 · Cited by 3
Acoustic Microscopy for Biomedical Applications
Bereiter‐Hahn, J. (2012) · Wiley eBooks · doi:10.1002/9781118271933.ch12 · Cited by 3
Reberte, S. B., Zúñiga-Aguilar, E., Manrique, S. I. R., & Perez, C. A. (2025) · eXPRESS Polymer Letters · doi:10.3144/expresspolymlett.2025.23 · Cited by 3
Rousseau, N., Chabrand, P. R., Destainville, A., Richart, O., & Milan, J. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1950144 · Cited by 3
Injection Device for Percutaneous Osteoplasty
Garnon, J., Meylheuc, L., Harrer, L., Koch, G., Gangi, A., & Bayle, B. (2020) · Mechanisms and machine science · doi:10.1007/978-3-030-58104-6_10 · Cited by 3
Synnott, S. (2018) · Scholarship@Western (Western University) · Cited by 3
Boundary Integral Equation Method in Elasticity with Microstructure
Shmoylova, E. (2006) · UWSpace (University of Waterloo) · Cited by 3
Fang, Z., Ranslow, A. N., Tomas-Medina, P. D., Gunnarsson, A., Weerasooriya, T., Satapathy, S., Thompson, K. A., & Kraft, R. H. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4039895 · Cited by 2
Choi, A. H. (2023) · Tissue repair and reconstruction · doi:10.1007/978-981-99-1425-8_5 · Cited by 2
Effect of Window Geometry on Strength of Shaft Part of Femur Bone
Hedayati, R., & Zare, S. M. F. A. (2015) · Periodica Polytechnica Mechanical Engineering · doi:10.3311/ppme.7861 · Cited by 2
Rennick, J. A. (2012) · Digital Repository Service (Northeastern University) · doi:10.17760/d20002649 · Cited by 2
Ding, H. D., Zhu, Z.-A., Dai, K., Ye, M., & Wang, C. (2008) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-008-0623-5 · Cited by 2
Gujar, R. A., Warhatkar, H. N., & Kale, A. (2023) · Journal of The Institution of Engineers (India) Series C · doi:10.1007/s40032-023-00944-x · Cited by 2
Rodríguez-Quesada, L., Ramírez‐Sánchez, K., Formosa‐Dague, C., Dague, É., Sáenz‐Arce, G., García‐González, C. A., Vásquez-Sancho, F., Avendaño, E., & Starbird-Perez, R. (2024) · ACS Omega · doi:10.1021/acsomega.4c04391 · Cited by 2
Wang, X., Nyman, J. S., Dong, X., Leng, H., & Reyes, M. (2010) · Synthesis lectures on tissue engineering · doi:10.1007/978-3-031-02579-2_4 · Cited by 2
Modelo constitutivo para tejido óseo humano : propiedades mecánicas del hueso cortical de costilla
Velázquez-Ameijide, J. (2015) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-98911 · Cited by 2
Cole, J. H., & van der Meulen, M. C. H. (2020) · Contemporary Endocrinology · doi:10.1007/978-3-319-69287-6_10 · Cited by 2
Osteoclast Biology and Mechanosensing
Pawlak, G., Vives, V., Blangy, A., Planus, E., & Albigès‐Rizo, C. (2010) · Springer eBooks · doi:10.1007/978-4-431-89757-6_14 · Cited by 2
Mechanical Properties of Bone Due to SOST Expression: A 3-Point Bending Assessment of Murine Femurs
Peterson, K. J. (2012) · DigitalCommons - CalPoly (California State Polytechnic University) · doi:10.15368/theses.2012.49 · Cited by 2
Karunaratne, A. (2016) · Springer eBooks · doi:10.1007/978-3-319-21867-0_5 · Cited by 2
Interaction implant – os élastique micropolaire : une investigation numérique
Pierson, G. (2019) · theses.fr (ABES) · doi:10.70675/e7c2e762zef27z4b43z9d37z50a272080c82 · Cited by 2
Wen, J. H., Taylor‐Weiner, H., Fuhrmann, A., & Engler, A. J. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch18 · Cited by 2
Mouss, M. E., Merzouki, T., Rekik, A., & Hambli, R. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105130 · Cited by 2
Zhang, J., & Ovaert, T. C. (2007) · ASME Summer Bioengineering Conference (SBC) · doi:10.1115/sbc2007-176801 · Cited by 2
Bala, Y. (2011) · theses.fr (ABES) · doi:10.70675/9675ed59zf96cz4bfbz8f62za95a95f50fff · Cited by 2
Prot, M. (2015) · theses.fr (ABES) · doi:10.70675/a1084892z1c70z4233zb77cz230185a16af9 · Cited by 2
Cai, X. (2018) · theses.fr (ABES) · doi:10.70675/04153575zbf51z4b21z9116zba8559aefee1 · Cited by 2
Design and Optimization of a Patient-Specific Additively Manufactured Subperiosteal Ceramic Implant
Aigner, D. (2022) · reposiTUm (TU Wien) · doi:10.34726/hss.2022.103261 · Cited by 2
Inorganic bionanocomposites for bone tissue engineering
Mankotia, P., Sharma, K., Sharma, V., Sehgal, R., & Kumar, V. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-85784-0.00013-3 · Cited by 2
MECHANICAL PROPERTIES OF BONE DUE TO SOST EXPRESSION: NANOINDENTATION ASSESSMENT OF MURINE FEMURS
Rafie, A. (2013) · DigitalCommons - CalPoly (California State Polytechnic University) · doi:10.15368/theses.2013.205 · Cited by 2
Pakuła, M., Kaczmarek, M., & Padilla, F. R. (2010) · Springer eBooks · doi:10.1007/978-94-007-0017-8_5 · Cited by 2
Overlooked role of bone quality in cranial adaptations to altered loading patterns
Ravosa, M. J., & Franks, E. M. (2025) · The Anatomical Record · doi:10.1002/ar.70022 · Cited by 2
Gudde, A. N. (2018) · Research Repository (Delft University of Technology) · Cited by 2
Multiscale modeling of elastic moduli and strength of bone
Hamed, E. (2012) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · Cited by 2
Elastic Properties and Measurement Techniques of Hard Tissues
(2001) · Elsevier eBooks · doi:10.1016/b978-012445760-7/50059-9 · Cited by 2
Biodegradable thermoplastic elastomers: tuning viscoelastic properties and shape memory
Ferrero, S. P. (2016) · Communities in ADDI (Universidad del Pais Vasco) · Cited by 2
Microscopic Multi-Directional Mechanical Properties of Human Femoral Cancellous Bone Tissue
Park, Y. H., Cha, H. S., & Hong, J. H. (2007) · Key engineering materials · doi:10.4028/www.scientific.net/kem.342-343.13 · Cited by 2
Katz, J. L. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.ch18 · Cited by 2
Modelling cancellous bone screw performance using finite element models
Piper, A. T. (2016) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 2
Rapoff, A. J. (2006) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-006-9838-x · Cited by 2
Nanoscale Mechanical Properties — Measuring Techniques and Applications
Kulik, A., Kis, A., Gremaud, G., Hengsberger, S., Zysset, P. K., & Forró, L. (2006) · Springer eBooks · doi:10.1007/3-540-28248-3_11 · Cited by 2
Evaluation of Mechanical Properties of Regenerated Bone by Nanoindentation Technique
Ishimoto, T., & Nakano, T. (2010) · Materials science forum · doi:10.4028/www.scientific.net/msf.654-656.2220 · Cited by 2
Mechanical analysis of bone and its internal fixation
Gao, X. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1952/4/042055 · Cited by 2
Rohrbach, D. J. (2013) · edoc Publication server (Humboldt University of Berlin) · doi:10.18452/16813 · Cited by 2
Janc, K., Tarasiuk, J., Lipiński, P., Bonnet, A.-S., & Wroński, S. (2020) · doi:10.24423/aom.3469 · Cited by 2
García, E. G. (2013) · mediaTUM (Technical University of Munich) · Cited by 2
Composition and mechanical properties of osteoarthritic subchondral trabecular tibial bone
Gleeson, J. P. (2007) · Arrow@dit (Dublin Institute of Technology) · Cited by 1
Metadata
- Authors
- Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M.
- Affiliations
- Indiana University School of Medicine (US)
- University of Memphis (US)
- Indiana University (US)
- Rice University (US)
- Corresponding author
- Turner, Charles H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 32
- Issue
- 4
- Pages
- 437-441
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2045985308
- Cited by
- 547
- References
- 27
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 14 · 2023: 8 · 2022: 11 · 2021: 18 · 2020: 21 · 2019: 19 · 2018: 20 · 2017: 15 · 2016: 17 · 2015: 29 · 2014: 36 · 2013: 21 · 2012: 34
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Energy
- Lockheed Martin
- Oak Ridge Associated Universities
- National Institutes of Health (5r01de011291-02)
- U.S. Public Health Service
- National Institute of Dental and Craniofacial Research (DE11291)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Mechanics of Materials › Metal and Thin Film Mechanics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Keywords
- trabecular bone, cortical bone, Young's modulus, elastic properties, acoustic microscopy, nanoindentation, anisotropy, anisotropy ratio, bone microarchitecture
- MeSH terms
- Aged, Algorithms, Elasticity, Femur, Hardness, Humans, Male, Microscopy, Stress, Mechanical, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.