The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques
The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Abstract
Acoustic microscopy (30-60 microm resolution) and nanoindentation (1-5 microm resolution) are techniques that can be used to evaluate the elastic properties of human bone at a microstructural level. The goals of the current study were (1) to measure and compare the Young's moduli of trabecular and cortical bone tissues from a common human donor, and (2) to compare the Young's moduli of bone tissue measured using acoustic microscopy to those measured using nanoindentation. The Young's modulus of cortical bone in the longitudinal direction was about 40% greater than (p<0.01) the Young's modulus in the transverse direction. The Young's modulus of trabecular bone tissue was slightly higher than the transverse Young's modulus of cortical bone, but substantially lower than the longitudinal Young's modulus of cortical bone. These findings were consistent for both measurement methods and suggest that elasticity of trabecular tissue is within the range of that of cortical bone tissue. The calculation of Young's modulus using nanoindentation assumes that the material is elastically isotropic. The current results, i.e., the average anisotropy ratio (E(L)/E(T)) for cortical bone determined by nanoindentation was similar to that determined by the acoustic microscope, suggest that this assumption does not limit nanoindentation as a technique for measurement of Young's modulus in anisotropic bone.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [138]
Citations
Cites
Oliver, W. C., & Pharr, G. M. (1992) · Journal of Materials Research · doi:10.1557/jmr.1992.1564 · Cited by 26,961
Self-citationA method for interpreting the data from depth-sensing indentation instruments
Doerner, M. F., & Nix, W. D. (1986) · Journal of Materials Research · doi:10.1557/jmr.1986.0601 · Cited by 2,863
Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
Rho, J. Y., Ashman, R. B., & Turner, C. H. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90042-d · Cited by 1,283
Self-citationMeasurement of Thin Film Mechanical Properties Using Nanoindentation
Pharr, G. M., & Oliver, W. C. (1992) · MRS Bulletin · doi:10.1557/s0883769400041634 · Cited by 1,012
Self-citationElastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Self-citationA continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citationComposition of trabecular and cortical bone
Gong, J. K., Arnold, J. S., & Cohn, S. H. (1964) · The Anatomical Record · doi:10.1002/ar.1091490303 · Cited by 308
Research works printed but not linked: 2
- Ko, C.C., Douglas, W.H., Cheng, Y.S., 1995. Intrinsic mechanical competence of cortical and trabecular bone measured by nanoindentation and microindentation probes. 1995 ASME Bioengineering Conference, ASME BED-Vol. 29, pp. 415–416.
- Runkle, 1975, The micro-mechanics of cancellous bone, Bulletin of the Hospital for Joint Diseases, 36, 2
Cited by
Items 101–200 of 651
Novitskaya, E. E., Chen, P., Hamed, E., Jun, L., Lubarda, V. A., Jasiuk, I., & McKittrick, J. M. (2011) · Theoretical and Applied Mechanics · doi:10.2298/tam1103209n · Cited by 93
Simulation of ultrasonic pulse propagation, distortion, and attenuation in the human chest wall
Mast, T. D., Hinkelman, L. M., Metlay, L. A., Orr, M. J., & Waag, R. C. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.428209 · Cited by 93
Contribution of inter-site variations in architecture to trabecular bone apparent yield strains
Morgan, E. F., Bayraktar, H. H., Yeh, O. C., Majumdar, S., Burghardt, A. J., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.037 · Cited by 92
Velioglu, Z. B., Pulat, D., Demirbakan, B., Özcan, B., Bayrak, E., & Erişken, C. (2018) · Connective Tissue Research · doi:10.1080/03008207.2018.1499732 · Cited by 90
3D scanning SAXS: A novel method for the assessment of bone ultrastructure orientation
Georgiadis, M., Guizar‐Sicairos, M., Zwahlen, A., Trüssel, A. J., Bunk, O., Müller, R., & Schneider, P. (2014) · Bone · doi:10.1016/j.bone.2014.10.002 · Cited by 90
Elastic Anisotropy of Human Cortical Bone Secondary Osteons Measured by Nanoindentation
Franzoso, G., & Zysset, P. K. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3005162 · Cited by 89
Marcián, P., Borák, L., Valášek, J., Kaiser, J., Florián, Z., & Wolff, J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.10.019 · Cited by 88
Cell-Wall Mechanical Properties of Bamboo Investigated by In-Situ Imaging Nanoindentation
Yu, Y., Fei, B., Zhang, B., & Yu, X. (2007) · Wood and Fiber Science · Cited by 86
A comparative study of orthotropic and isotropic bone adaptation in the femur
Geraldes, D. M., & Phillips, A. (2014) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2633 · Cited by 85
Jang, I. G., & Kim, I. Y. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.012 · Cited by 84
Vilayphiou, N., Boutroy, S., Sornay‐Rendu, E., van Rietbergen, B., & Chapurlat, R. D. (2015) · Bone · doi:10.1016/j.bone.2015.10.012 · Cited by 84
Measurement of the microstructural fracture toughness of cortical bone using indentation fracture
Mullins, L. P., Bruzzi, M., & McHugh, P. E. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.04.020 · Cited by 82
Cong, A. X., den Buijs, J. O., & Dragomir‐Daescu, D. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.09.018 · Cited by 82
Nikolaus, A., Currey, J. D., Lindtner, T., Fleck, C., & Zaslansky, P. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.11.020 · Cited by 82
Özkan, N., Xin, H., & Chen, X. D. (2002) · Journal of Food Science · doi:10.1111/j.1365-2621.2002.tb08728.x · Cited by 82
Apparent Young's modulus of human radius using inverse finite-element method
Bosisio, M. R., Talmant, M., Skalli, W., Laugier, P., & Mitton, D. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.09.018 · Cited by 81
The Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2008) · Elsevier eBooks · doi:10.1016/b978-012370544-0.50003-3 · Cited by 81
Mathieu, V., Fukui, K., Matsukawa, M., Kawabe, M., Vayron, R., Soffer, E., Anagnostou, F., & Haïat, G. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4003131 · Cited by 81
Bone Intrinsic Material Properties in Three Inbred Mouse Strains
Akhter, M. P., Fan, Z., & Rho, J. Y. (2004) · Calcified Tissue International · doi:10.1007/s00223-004-0241-7 · Cited by 81
Self-citationHellmich, C., & Ulm, F. (2005) · Transport in Porous Media · doi:10.1007/s11242-004-6298-y · Cited by 80
Zanetti, E. M., Pascoletti, G., Calì, M., Bignardi, C., & Franceschini, G. (2018) · Biosensors · doi:10.3390/bios8030068 · Cited by 79
Bone Remodeling as a Hybrid Cellular Automaton Optimization Process
Tovar, A. (2004) · Figshare · doi:10.7274/dv13zs28316 · Cited by 77
Jiang, J., & Papoutsakis, E. T. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200169 · Cited by 76
Dubey, D. K., & Tomar, V. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.02.035 · Cited by 76
Guo, X.-D. E., & Goldstein, S. A. (2000) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100180224 · Cited by 75
New insights into nickel-free superelastic titanium alloys for biomedical applications
Ramezannejad, A., Xu, W., Xiao, W. L., Fox, K. E., Liang, D., & Qian, M. (2019) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2019.100783 · Cited by 74
Elasticity of alveolar bone near dental implant–bone interfaces after one month's healing
Chang, M. C., Ko, C., Liu, C., DOUGLAS, W. H. J., DeLong, R., Seong, W., Hodges, J. S., & An, K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00113-1 · Cited by 74
Experimental Techniques for Bone Mechanics
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263-12 · Cited by 72
Cook, D. D., Julias, M., & Nauman, E. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.01.040 · Cited by 72
Mitsuishi, M., Cao, J., Bártolo, P., Friedrich, D., Shih, A. J., Rajurkar, K. P., Sugita, N., & Harada, K. (2013) · CIRP Annals · doi:10.1016/j.cirp.2013.05.001 · Cited by 71
Understanding the structure–property relationship in cortical bone to design a biomimetic composite
Libonati, F., & Vergani, L. M. (2015) · Composite Structures · doi:10.1016/j.compstruct.2015.12.003 · Cited by 71
Luczynski, K. W., Steiger-Thirsfeld, A., Bernardi, J., Eberhardsteiner, J., & Hellmich, C. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2015.03.001 · Cited by 70
Effects of total lignans from Eucommia ulmoides barks prevent bone loss in vivo and in vitro
Zhang, R., Pan, Y., Hu, S., Kong, X., Wang, J., & Mei, Q. (2014) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2014.04.031 · Cited by 70
Effect of angiotensin II type 1 receptor blocker on osteoporotic rat femurs
Dönmez, B. Ö., Özdemir, S., Sarıkanat, M., Yaraş, N., Koç, P., Demır, N., Karayalçın, B., & Oğuz, N. (2012) · Pharmacological Reports · doi:10.1016/s1734-1140(12)70882-4 · Cited by 69
Deriving tissue density and elastic modulus from microCT bone scans
Wagner, D. W., Lindsey, D. P., & Beaupré, G. S. (2011) · Bone · doi:10.1016/j.bone.2011.07.021 · Cited by 69
Calibration of a constitutive model for the post-yield behaviour of cortical bone
Mullins, L. P., Bruzzi, M., & McHugh, P. E. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.11.003 · Cited by 68
Direct comparison of nanoindentation and macroscopic measurements of bone viscoelasticity
Shepherd, T. N., Zhang, J., Ovaert, T. C., Roeder, R. K., & Niebur, G. L. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.07.004 · Cited by 68
Pakuła, M., Padilla, F. R., Laugier, P., & Kaczmarek, M. (2008) · The Journal of the Acoustical Society of America · doi:10.1121/1.2839016 · Cited by 67
Raum, K., Reißhauer, J., & Brandt, J. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30156 · Cited by 67
Brennan, O., Kennedy, O. D., Lee, T. C., Rackard, S. M., & O’Brien, F. J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.11.032 · Cited by 66
Mittra, E., Akella, S., & Qin, Y. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30742 · Cited by 65
Geraldes, D. M., Modenese, L., & Phillips, A. (2015) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-015-0740-7 · Cited by 65
Lakshmanan, S., Bodi, A., & Raum, K. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.426 · Cited by 65
Takada, H., Abe, S., Tamatsu, Y., Mitarashi, S., Saka, H., & Ide, Y. (2006) · Dental Traumatology · doi:10.1111/j.1600-9657.2006.00368.x · Cited by 65
Silva, M. J., Brodt, M. D., & Hucker, W. J. (2005) · The Anatomical Record Part A Discoveries in Molecular Cellular and Evolutionary Biology · doi:10.1002/ar.a.20171 · Cited by 63
ZHU, T. Y., Griffith, J. F., Qin, L., Hung, V. W.-Y., Fong, T.-N., Au, S.-K., Li, M., Lam, Y. Y. O., Wong, C. K., Kwok, A. W. L., et al. (2014) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.2221 · Cited by 63
Microtensile properties and failure mechanisms of cortical bone at the lamellar level
Casari, D., Michler, J., Zysset, P. K., & Schwiedrzik, J. J. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.04.030 · Cited by 63
Rémond, A., Naïli, S., & Lemaire, T. (2007) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-007-0111-0 · Cited by 63
Nanoscale geomechanical properties of Western Australian coal
Yu, H., Zhang, Y., Lebedev, M., Han, T., Verrall, M., Wang, Z., Al‐Khdheeawi, E. A., Al-Yaseri, A. Z., & Iglauer, S. (2017) · Journal of Petroleum Science and Engineering · doi:10.1016/j.petrol.2017.11.001 · Cited by 63
Scanning Acoustic Microscopy Study of Human Cortical and Trabecular Bone
Bumrerraj, S., & Katz, J. L. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1424908 · Cited by 60
ZHU, T. Y., Griffith, J. F., Qin, L., HUNG, V. W., Fong, T.-N., Au, S.-K., Tang, X., Kwok, A. W. L., Leung, P., Li, E. K., et al. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1793 · Cited by 60
Biomechanical evaluation of regenerating long bone by nanoindentation
Ishimoto, T., Nakano, T., Yamamoto, M., & Tabata, Y. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4266-y · Cited by 60
Compositional and mechanical properties of growing cortical bone tissue: a study of the human fibula
Lefèvre, E., Farlay, D., Bala, Y., Subtil, F., Wolfram, U., Rizzo, S., Baron, C., Zysset, P. K., Pithioux, M., & Follet, H. (2019) · Scientific Reports · doi:10.1038/s41598-019-54016-1 · Cited by 59
Computational investigations of mechanical failures of internal plate fixation
Chen, G., Schmutz, B., Wullschleger, M., Pearcy, M. J., & Schuetz, M. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim670 · Cited by 59
Nanoindentation of the insertional zones of human meniscal attachments into underlying bone
Hauch, K., Oyen, M. L., Odegard, G. M., & Donahue, T. L. H. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.10.005 · Cited by 58
Microindentation can discriminate between damaged and intact human bone tissue
Dall’Ara, E., Schmidt, R., & Zysset, P. K. (2012) · Bone · doi:10.1016/j.bone.2012.01.002 · Cited by 58
Baron, C., Talmant, M., & Laugier, P. (2007) · The Journal of the Acoustical Society of America · doi:10.1121/1.2759165 · Cited by 58
Mechanical properties of OI type III bone tissue measured by nanoindentation
Fan, Z., Smith, P. A., Eckstein, E. C., & Harris, G. F. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30713 · Cited by 58
Local strain and damage mapping in single trabeculae during three-point bending tests
Jungmann, R., Szabo, M. E., Schitter, G., Yue-Sing Tang, R., Vashishth, D., Hansma, P. K., & Thurner, P. J. (2011) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2010.12.009 · Cited by 57
“…et al., 1989; Ruegsegger et al., 1996) or magnetic resonance imaging (Wehrli et al., 2002), the bone matrix material properties can so far only be determined in vitro from mechanical testing experiments (Choi et al., 1990; Turner et al., 1999; Zysset et al., 1999; Nalla et al., 2003, 2005).”
Cyganik, Ł., Binkowski, M., Kokot, G., Rusin, T., Popik, P., Bolechała, F., Nowak, R., Wróbel, Z., & John, A. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.04.011 · Cited by 57
Bone properties by nanoindentation in mild and severe osteogenesis imperfecta
Albert, C., Jameson, J., Toth, J. M., Smith, P. A., & Harris, G. E. (2012) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2012.10.003 · Cited by 57
Marcián, P., Borák, L., Zikmund, T., Horáčková, L., Kaiser, J., Joukal, M., & Wolff, J. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104393 · Cited by 56
Application of Nanoindentation Development of Biomedical to Materials
Haque, F. (2003) · Surface Engineering · doi:10.1179/026708403322499173 · Cited by 56
Fuller, H., Fuller, R., & Pereira, R. M. R. (2014) · Revista Brasileira de Reumatologia · doi:10.1016/j.rbr.2014.07.010 · Cited by 55
Caravaggi, P., Liverani, E., Leardini, A., Fortunato, A., Belvedere, C., Baruffaldi, F., Fini, M., Parrilli, A., Mattioli‐Belmonte, M., Tomesani, L., et al. (2019) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34328 · Cited by 55
Szulc, P., Boutroy, S., & Chapurlat, R. D. (2018) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3451 · Cited by 55
Biodegradable/biocompatible coated metal implants for orthopedic applications
Saleh, M. M., Touny, A. H., Al‐Omair, M. A., & SALEH, M. M. (2016) · Bio-Medical Materials and Engineering · doi:10.3233/bme-161568 · Cited by 55
Fabric dependence of wave propagation in anisotropic porous media
Cowin, S. C., & Cardoso, L. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0217-7 · Cited by 54
Frank, M., Reisinger, A., Andriotis, O. G., Pahr, D. H., & Thurner, P. J. (2024) · JBMR Plus · doi:10.1093/jbmrpl/ziae049 · Cited by 53
Bioinspired Collagen Scaffolds in Cranial Bone Regeneration: From Bedside to Bench
Lee, J. C., & Volpicelli, E. J. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700232 · Cited by 53
Design Optimization of Cementless Femoral Hip Prostheses Using Finite Element Analysis
Kowalczyk, P. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1392311 · Cited by 53
An improved method for the measurement of mechanical properties of bone by nanoindentation
Tang, B. H., Ngan, A. H. W., & Lu, W. W. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3031-8 · Cited by 51
Jørgensen, C., & Kundu, T. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00061-4 · Cited by 51
Structural and mechanical profiles of native collagen fibers in vaginal wall connective tissues
Sridharan, I., Ma, Y., Kim, T., Kobak, W. H., Rotmensch, J., & Wang, R. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.11.005 · Cited by 50
Glycosaminoglycan degradation reduces mineralized tissue–titanium interfacial strength
Nakamura, H. K., Shim, J., Butz, F., Aita, H., Gupta, V., & Ogawa, T. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30624 · Cited by 50
McDonald, K. A., Little, J. P., Pearcy, M. J., & Adam, C. J. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.04.006 · Cited by 49
Highly Flexible Single-Unit Resolution All Printed Neural Interface on a Bioresorbable Backbone
Almasri, R. M., AlChamaa, W., Tehrani‐Bagha, A. R., & Khraiche, M. L. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00895 · Cited by 49
Nanoindentation analysis of the micromechanical anisotropy in mouse cortical bone
Casanova, M., Balmelli, A., Carnelli, D., Courty, D., Schneider, P., & Müller, R. (2017) · Royal Society Open Science · doi:10.1098/rsos.160971 · Cited by 48
Barkaoui, A., Chamekh, A., Merzouki, T., Hambli, R., & Mkaddem, A. (2013) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2604 · Cited by 49
Modeling of bone at a single lamella level
Jasiuk, I., & Ostoja‐Starzewski, M. (2004) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0048-5 · Cited by 48
van Eijden, T. M. G. J., van Ruijven, L. J., & Giesen, E. B. W. (2004) · Calcified Tissue International · doi:10.1007/s00223-004-0295-6 · Cited by 47
Rupin, F., Saïed, A., Dalmas, D., Peyrin, F., Haupert, S., Raum, K., Barthel, É., Boivin, G., & Laugier, P. (2009) · Japanese Journal of Applied Physics · doi:10.1143/jjap.48.07gk01 · Cited by 47
The Materials Science of Bone: Lessons from Nature for Biomimetic Materials Synthesis
Oyen, M. L. (2008) · MRS Bulletin · doi:10.1557/mrs2008.14 · Cited by 47
Hargrave-Thomas, E., van Sloun, F., Dickinson, M., Broom, N. D., & Thambyah, A. (2015) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2015.05.012 · Cited by 47
Albert, C., Jameson, J., Smith, P. A., & Harris, G. E. (2014) · Bone · doi:10.1016/j.bone.2014.05.022 · Cited by 46
de Ruiter, L., Janssen, D. W., Briscoe, A., & Verdonschot, N. J. J. (2017) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-017-0078-4 · Cited by 46
Litniewski, J. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.06.009 · Cited by 45
Micromechanical modelling of cortical bone
Mullins, L. P., McGarry, P., Bruzzi, M., & McHugh, P. E. (2007) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840601110802 · Cited by 45
Asgari, M., Abi‐Rafeh, J., Hendy, G. N., & Pasini, D. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.01.024 · Cited by 44
The Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-375098-3.50004-4 · Cited by 44
Finite element analysis of bone loss around failing implants
Wolff, J., Narra, N., Antalainen, A.-K., Valášek, J., Kaiser, J., Sándor, G. K. B., & Marcián, P. (2014) · Materials & Design (1980-2015) · doi:10.1016/j.matdes.2014.04.080 · Cited by 44
Variations of microstructure, mineral density and tissue elasticity in B6/C3H mice
Raum, K., Hofmann, T., Leguerney, I., Saïed, A., Peyrin, F., Vico, L., & Laugier, P. (2007) · Bone · doi:10.1016/j.bone.2007.08.042 · Cited by 44
Nano-mechanics of bone and bioactive bone cement interfaces in a load-bearing model
Ni, G., Choy, Y. S., Lu, W. W., Ngan, A., Chiu, P., Li, Z., Tang, B. H., & Luk, K. D. K. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.044 · Cited by 43
Beaupied, H., Dupuis, A., Arlettaz, A., Brunet-Imbault, B., Bonnet, N., Jaffré, C., Benhamou, C.-L., & Courteix, D. (2006) · Bio-Medical Materials and Engineering · doi:10.1177/09592989200601600401021 · Cited by 43
Cattaneo, P. M., Kofod, T., Dalstra, M., & Melsen, B. (2005) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840500237953 · Cited by 43
de Ruiter, L., Janssen, D. W., Briscoe, A., & Verdonschot, N. J. J. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917738805 · Cited by 43
Sun, L., Fan, Y., Li, D., Zhao, F., Xie, T., Yang, X. Y., & Gu, Z.-T. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.04.042 · Cited by 43
McNamara, L. M. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00068-4 · Cited by 42
Role of structural anisotropy of biological tissues in poroelastic wave propagation
Cardoso, L., & Cowin, S. C. (2011) · Mechanics of Materials · doi:10.1016/j.mechmat.2011.08.007 · Cited by 42
Torres-Sánchez, C., McLaughlin, J., & Fotticchia, A. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.10.026 · Cited by 42
Metadata
- Authors
- Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M.
- Affiliations
- Indiana University School of Medicine (US)
- University of Memphis (US)
- Indiana University (US)
- Rice University (US)
- Corresponding author
- Turner, Charles H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-04
- Volume
- 32
- Issue
- 4
- Pages
- 437-441
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2045985308
- Cited by
- 547
- References
- 27
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 14 · 2023: 8 · 2022: 11 · 2021: 18 · 2020: 21 · 2019: 19 · 2018: 20 · 2017: 15 · 2016: 17 · 2015: 29 · 2014: 36 · 2013: 21 · 2012: 34
- FWCI
- 11.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Energy
- Lockheed Martin
- Oak Ridge Associated Universities
- National Institutes of Health (5r01de011291-02)
- U.S. Public Health Service
- National Institute of Dental and Craniofacial Research (DE11291)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Mechanics of Materials › Metal and Thin Film Mechanics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Keywords
- trabecular bone, cortical bone, Young's modulus, elastic properties, acoustic microscopy, nanoindentation, anisotropy, anisotropy ratio, bone microarchitecture
- MeSH terms
- Aged, Algorithms, Elasticity, Femur, Hardness, Humans, Male, Microscopy, Stress, Mechanical, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.