Biomechanics of Fracture Risk Prediction of the Hip and Spine by Quantitative Computed Tomography
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
In this review, we have made use of some simple engineering concepts to summarize current efforts relating QCT measures to bone density and strength. From a variety of in vitro experiments on cadaveric vertebrae and femora, it is evident that both apparent and ash densities are strong linear functions of QCT measures, with coefficients of determination ranging from 0.49 to 0.90 and relative errors from 44.9% to 7.1%. QCT data also can be used (with somewhat less confidence) to determine the compressive modulus (R2s from 0.36 to 0.68, relative errors from 45.0% to 35.5%) and compressive strength (R2s from 0.58 to 0.70, relative errors from 56.5% to 39.9%) of trabecular bone from the proximal femur and vertebral body. In cortical bone, material properties are only correlated weakly with QCT measures. Experiments designed to relate QCT data to failure loads for the proximal femur and vertebral body have been remarkably successful. Coefficients of determination have ranged from 0.32 to 0.93, with relative errors from 31.1% to 13.9%. However, when the in vitro failure loads determined in these experiments are compared against available estimates of in vivo loads on the spine and hip, it is apparent, at least in the elderly, that in vivo loads are relatively close to those that cause fracture in vitro. To assess the possibility of developing QCT-based clinical predictors of fracture risk for individual patients, we have introduced the concept factor of risk often used in engineering design to account for uncertainties in estimates of service loads and component strength. The factor of risk for a particular loading condition is defined as the ratio of expected service loads to the known failure loads. To extend this concept to densitometric fracture risk prediction in vivo, it is important to recognize that densitometric data must not only be used to predict the ultimate load carrying capacity of the region of interest, but that this ultimate load must then be compared to the forces expected in vivo under comparable loading conditions. One difficulty with this approach is that little is known about the in vivo forces that are associated with atraumatic age-related fractures of the hip and vertebrae and even less about the forces applied to the hip and spine during traumatic events such as falls. However, from available estimates of in vivo loads during bending and lifting, it is apparent that in the elderly, factors of risk for the spine can easily approach 1.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Self-citationRiggs, B. L., & Melton, L. J. (1986) · New England Journal of Medicine · doi:10.1056/nejm198606263142605 · Cited by 1,915
Age and bone mass as predictors of fracture in a prospective study.
Hui, S. L., Slemenda, C. W., & Johnston, C. C. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113523 · Cited by 1,166
Reliability in engineering design
Kapur, K. C., & Lamberson, L. R. (1977) · Cited by 1,132
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
EPIDEMIOLOGY OF VERTEBRAL FRACTURES IN WOMEN
MELTON, L. J., KAN, S. H., FRYE, M. A., WAHNER, H. W., O'FALLON, W. M., & RIGGS, B. L. (1989) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a115204 · Cited by 924
Changes in Bone Mineral Density of the Proximal Femur and Spine with Aging
Riggs, B. L., Wahner, H. W., Seeman, E., Offord, K. P., Dunn, W. L., Mazess, R. B., Johnson, K. A., & Melton, L. J. (1982) · Journal of Clinical Investigation · doi:10.1172/jci110667 · Cited by 816
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Self-citationThe mechanical properties of trabecular bone: Dependence on anatomic location and function
Goldstein, S. A. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90023-6 · Cited by 687
Cited by
Cooper, C., Atkinson, E. J., MichaelO'Fallon, W., & Dr. Melton, J. L. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070214 · Cited by 1,528
Bauer, D. C. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440270067006 · Cited by 800
The Prevention and Treatment of Osteoporosis
Wood, A. J. J., Riggs, B. L., & Melton, L. J. (1992) · New England Journal of Medicine · doi:10.1056/nejm199208273270908 · Cited by 754
Simple measurement of femoral geometry predicts hip fracture: The study of osteoporotic fractures
Faulkner, K. G., Cummings, S. R., Black, D., Palermo, L., Glüer, C.-C., & Genant, H. K. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650081008 · Cited by 706
Bone Microdamage and Skeletal Fragility in Osteoporotic and Stress Fractures
Burr, D. B., Forwood, M. R., Fyhrie, D. P., Martin, R. B., Schaffler, M. B., & Turner, C. H. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.1.6 · Cited by 686
Perspectives: How many women have osteoporosis now?
Dr. Melton, J. L. (1995) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650100202 · Cited by 595
Type of Fall and Risk of Hip and Wrist Fractures: The Study of Osteoporotic Fractures
Nevitt, M. C., Cummings, S. R., & Study of Osteoporotic Fractures Research Group (1993) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1993.tb07307.x · Cited by 561
Glüer, C.-C., & FOR THE INTERNATIONAL QUANTITATIVE ULTRASOUND CONSENSUS GROUP (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.8.1280 · Cited by 501
Lau, E. M. C. (2005) · Current Topics in Osteoporosis · doi:10.1142/9789812701220_0001 · Cited by 499
Hip fractures: A worldwide problem today and tomorrow
Melton, L. J. (1993) · Bone · doi:10.1016/8756-3282(93)90341-7 · Cited by 481
Boutroy, S., Van Rietbergen, B., Sornay-Rendu, E., Munoz, F., Bouxsein, M. L., & Delmas, P. D. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.071108 · Cited by 470
Effects of Bone Cement Volume and Distribution on Vertebral Stiffness After Vertebroplasty
Liebschner, M. A. K., Rosenberg, W. S., & Keaveny, T. M. (2001) · Spine · doi:10.1097/00007632-200107150-00009 · Cited by 470
Three quantitative ultrasound parameters reflect bone structure
Gluer, C. C., Wu, C. Y., Jergas, M., Goldstein, S. A., & Genant, H. K. (1994) · Calcified Tissue International · doi:10.1007/bf00310168 · Cited by 424
Cooper, C., & Melton, L. J. (1992) · Trends in Endocrinology & Metabolism · doi:10.1016/1043-2760(92)90032-v · Cited by 405
TYPE OF FALL AND RISK OF HIP AND WRIST FRACTURES: THE STUDY OF OSTEOPOROTIC FRACTURES
Nevitt, M. C., & Cummings, S. R. (1994) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1994.tb06576.x · Cited by 403
Macdonald, H. M., Nishiyama, K. K., Kang, J., Hanley, D. A., & Boyd, S. K. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.171 · Cited by 375
Majumdar, S., Kothari, M., Augat, P., Newitt, D. C., Link, T. M., Lin, J. C., Lang, T., Lu, Y., & Genant, H. K. (1998) · Bone · doi:10.1016/s8756-3282(98)00030-1 · Cited by 331
Cumming, R. G., Nevitt, M. C., & Cummings, S. R. (1997) · Epidemiologic Reviews · doi:10.1093/oxfordjournals.epirev.a017956 · Cited by 290
Broadband ultrasound attenuation signals depend on trabecular orientation: An in vitro study
Glüer, C. C., Wu, C. Y., & Genant, H. K. (1993) · Osteoporosis International · doi:10.1007/bf01623674 · Cited by 272
Taaffe, D. R. (1994) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.79.5.1361 · Cited by 270
Finite Element Analysis of the Proximal Femur and Hip Fracture Risk in Older Men
Orwoll, E. S., Marshall, L. M., Nielson, C. M., Cummings, S. R., Lapidus, J., Cauley, J. A., Ensrud, K., Lane, N., Hoffmann, P. R., Kopperdahl, D. L., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081201 · Cited by 265
Ferretti, J. L., Capozza, R. F., & Zanchetta, J. R. (1996) · Bone · doi:10.1016/8756-3282(95)00438-6 · Cited by 264
Epidemiology of hip fractures: Implications of the exponential increase with age
Melton, L. J. (1996) · Bone · doi:10.1016/8756-3282(95)00492-0 · Cited by 261
Reduction in proximal femoral strength due to long-duration spaceflight
Keyak, J. H., Koyama, A. K., LeBlanc, A., Lu, Y., & Lang, T. F. (2009) · Bone · doi:10.1016/j.bone.2008.11.014 · Cited by 236
Dimensions and estimated mechanical characteristics of the humerus after long-term tennis loading
Haapasalo, H., Sievanen, H., Kannus, P., Heinonen, A., Oja, P., & Vuori, I. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110619 · Cited by 224
Bouxsein, M. L., Szulc, P., Munoz, F., Thrall, E., Sornay-Rendu, E., & Delmas, P. D. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070309 · Cited by 217
“We computed the factor-of-risk for hip fracture ( ) as the ratio of the applied force to estimated femoral strength in a sideways fall.((21)) The factor of risk was calculated using both the peak force ( peak) and the attenuated force ( atten) estimates.”
BackgroundMethodCooper, C. (1999) · Osteoporosis International · doi:10.1007/pl00004156 · Cited by 216
Pinilla, T. P., Boardman, K. C., Bouxsein, M. L., Myers, E. R., & Hayes, W. C. (1996) · Calcified Tissue International · doi:10.1007/bf02508641 · Cited by 208
Self-citationQuantitative MRI for the assessment of bone structure and function
Wehrli, F. W., Song, H. K., Saha, P. K., & Wright, A. C. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1066 · Cited by 207
“exponent of approximately 2 (7)] and, further, that the intrinsic material strength remains invariant (i.”
BackgroundScreening and early diagnosis of osteoporosis through X-ray and ultrasound based techniques
Pisani, P. (2013) · World Journal of Radiology · doi:10.4329/wjr.v5.i11.398 · Cited by 193
Non-skeletal determinants of fractures: the potential importance of the mechanics of falls
Cummings, S. R., Nevitt, M. C., & the Study of Osteoporotic Fractures Research Group (1994) · Osteoporosis International · doi:10.1007/bf01623439 · Cited by 190
Finite element analysis for prediction of bone strength
Zysset, P. K., Dall'Ara, E., Varga, P., & Pahr, D. H. (2013) · BoneKEy Reports · doi:10.1038/bonekey.2013.120 · Cited by 188
Self-citationEbbesen, E. N., Thomsen, J. S., Beck-Nielsen, H., Nepper-Rasmussen, H. J., & Mosekilde, L. (1999) · Bone · doi:10.1016/s8756-3282(99)00216-1 · Cited by 187
Bone mass, bone strength, muscle–bone interactions, osteopenias and osteoporoses
Ferretti, J. (2003) · Mechanisms of Ageing and Development · doi:10.1016/s0047-6374(02)00194-x · Cited by 180
Link, T. M., Majumdar, S., Lin, J. C., Newitt, D., Augat, P., Ouyang, X., Mathur, A., & Genant, H. K. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.1.122 · Cited by 179
The Biomechanical Basis of Vertebral Body Fragility in Men and Women
Duan, Y., Seeman, E., & Turner, C. H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.12.2276 · Cited by 163
“Based on engineering principles and the concept of a “factor of risk” developed by several investigators, ((12,13))we applied a fracture risk index (FRI) or quantitative measure of bone fragility applicable to both genders using structural determinants of bone strength.”
BackgroundGlüer, C. C., Vahlensieck, M., Faulkner, K. G., Engelke, K., Black, D., & Genant, H. K. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650070910 · Cited by 162
Smoking, smoking cessation, and risk of hip fracture in women
Cornuz, J., Feskanich, D., Willett, W. C., & Colditz, G. A. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00022-4 · Cited by 161
Nishiyama, K. K., Macdonald, H. M., Moore, S. A., Fung, T., Boyd, S. K., & McKay, H. A. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.552 · Cited by 122
Compressive creep behavior of bovine trabecular bone
Bowman, S. M., Keaveny, T. M., Gibson, L. J., Hayes, W. C., & McMahon, T. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90006-x · Cited by 88
Self-citationLv, Q.-B., Fu, X., Jin, H.-M., Xu, H.-C., Huang, Z.-Y., Xu, H.-Z., Chi, Y.-L., & Wu, A.-M. (2015) · Scientific Reports · doi:10.1038/srep16030 · Cited by 38
Metadata
- Authors
- Hayes, W. C., Piazza, S. J., & Zysset, P. K.
- Venue
- Radiologic Clinics of North America
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 29
- Issue
- 1
- Pages
- 1-18
- ISSN
- 0033-8389 (ISSN-L)
- OpenAlex
- W1207479394
- Cited by
- 259
- References
- 58
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.