Microtissue Elasticity: Measurements by Atomic Force Microscopy and Its Influence on Cell Differentiation
The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915 · cited 5×
“Mesenchymal stem cells (MSCs) diVerentiate to each of these three cell lineages—nascent neurons, myocytes, and osteoblasts—when cultured in identical media on substrates with tissue-mimetic stiVness (Engler et al., 2006).”
BackgroundInfluentialSelf-citationUeber die Berührung fester elastischer Körper.
Hertz, H. (1882) · crll · doi:10.1515/crll.1882.92.156 · Cited by 4,789 · cited 1×
“…the sample thickness, h, can also be determined, but for thick samples (relative to the probe tip), use is generally made of classic expressions such as that of Hertz appropriate to a spherical tip (Hertz, 1882) or that of Sneddon for a conical tip (Sneddon, 1965) that approximates a pyramidal tip.”
MethodSneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346 · cited 2×
“…the sample thickness, h, can also be determined, but for thick samples (relative to the probe tip), use is generally made of classic expressions such as that of Hertz appropriate to a spherical tip (Hertz, 1882) or that of Sneddon for a conical tip (Sneddon, 1965) that approximates a pyramidal tip.”
MethodTensional homeostasis and the malignant phenotype
Paszek, M. J., Zahir, N., Johnson, K. R., Lakins, J. N., Rozenberg, G. I., Gefen, A., Reinhart-King, C. A., Margulies, S. S., Dembo, M., Boettiger, D., et al. (2005) · Cancer Cell · doi:10.1016/j.ccr.2005.08.010 · Cited by 3,941 · cited 6×
“In addition, breast epithelium tumorigenesis appears more pronounced on stiV substrates that mimic fibrotic tumors (Paszek et al., 2005), and the fibroblast to myofibroblast transition is promoted on gels that mimic fibrotic wound stiVness (GoYn et al.”
BackgroundInfluentialCell Movement Is Guided by the Rigidity of the Substrate
Lo, C.-M., Wang, H.-B., Dembo, M., & Wang, Y.-L. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76279-5 · Cited by 3,289 · cited 6×
“For a physiological comparison, maximum traction strains generated by 3T3 fibroblasts appear to be less than about 15–25% regardless of substrate modulus (Lo et al., 2000; Saez et al., 2005), which agrees well with the small strain assumptions made in AFM.”
BackgroundResultInfluentialCell locomotion and focal adhesions are regulated by substrate flexibility
Pelham, R. J., & Wang, Y.-L. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.25.13661 · Cited by 3,027
Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion
Yeung, T., Georges, P. C., Flanagan, L. A., Marg, B., Ortiz, M., Funaki, M., Zahir, N., Ming, W., Weaver, V., & Janmey, P. A. (2005) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.20041 · Cited by 2,325 · cited 3×
“…in vitro findings that even small microenvironmental variations—as small as 20–25% change in matrix stiVness—can have profound eVects on the diVerentiation processes cited above as well as other cell functions (Lo et al., 2000; Pelham and Wang, 1997; Peyton and Putnam, 2005; Yeung et al., 2005).”
BackgroundMyotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743 · cited 12×
“SMCs appear highly sensitive to the elasticity of their microenvironment, showing more stress fibers and focal adhesions on increasingly stiV matrices (Engler et al., 2004a) as do most other cell types in vitro.”
BackgroundMethodInfluentialSelf-citationNonlinear elasticity in biological gels
Storm, C., Pastore, J. J., MacKintosh, F. C., Lubensky, T. C., & Janmey, P. A. (2005) · Nature · doi:10.1038/nature03521 · Cited by 1,703 · cited 2×
“, 2002), although stiVening (increased E) at higher strains is the norm (Fung, 1994; Storm et al., 2005).”
Background
Cited by
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727
“Discher and coworkers demonstrated that the differentiation of human mesenchymal stem cells (hMSCs) is dependent on the mechanical stiffness of the 2D culture platform ( Engler et al., 2007, 2006 ).”
BackgroundEngler, A. J., Carag-Krieger, C., Johnson, C. P., Raab, M., Tang, H.-Y., Speicher, D. W., Sanger, J. W., Sanger, J. M., & Discher, D. E. (2008) · Journal of Cell Science · doi:10.1242/jcs.029678 · Cited by 865
Self-citationAtomic force microscopy-based mechanobiology
Krieg, M., Fläschner, G., Alsteens, D., Gaub, B. M., Roos, W. H., Wuite, G. J. L., Gaub, H. E., Gerber, C., Dufrêne, Y. F., & Müller, D. J. (2018) · Nature Reviews Physics · doi:10.1038/s42254-018-0001-7 · Cited by 799
The extracellular matrix and transforming growth factor-β1: Tale of a strained relationship
Hinz, B. (2015) · Matrix Biology · doi:10.1016/j.matbio.2015.05.006 · Cited by 608
Li, Y., Xiao, Y., & Liu, C. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00654 · Cited by 598
Age-Related Intimal Stiffening Enhances Endothelial Permeability and Leukocyte Transmigration
Huynh, J., Nishimura, N., Rana, K., Peloquin, J. M., Califano, J. P., Montague, C. R., King, M. R., Schaffer, C. B., & Reinhart-King, C. A. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002761 · Cited by 402
Wang, Y., Gunasekara, D. B., Reed, M. I., DiSalvo, M., Bultman, S. J., Sims, C. E., Magness, S. T., & Allbritton, N. L. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.005 · Cited by 373
Optimal matrix rigidity for stress-fibre polarization in stem cells
Zemel, A., Rehfeldt, F., Brown, A. E. X., Discher, D. E., & Safran, S. A. (2010) · Nature Physics · doi:10.1038/nphys1613 · Cited by 363
Self-citationLatest Advances in Cryogel Technology for Biomedical Applications
Memic, A., Colombani, T., Eggermont, L. J., Rezaeeyazdi, M., Steingold, J., Rogers, Z. J., Navare, K. J., Mohammed, H. S., & Bencherif, S. A. (2019) · Advanced Therapeutics · doi:10.1002/adtp.201800114 · Cited by 310
Skeletal muscle tissue engineering: methods to form skeletal myotubes and their applications
Ostrovidov, S., Hosseini, V., Ahadian, S., Fujie, T., Parthiban, S. P., Ramalingam, M., Bae, H., Kaji, H., & Khademhosseini, A. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2013.0534 · Cited by 302
“This optimal modulus value closely matched the elasticity of C2C12 myotubes, which is 12–15 kPa, 257 and the native skeletal muscle tissue stiffness value, which is 12 – 4 kPa, 258 as measured by atomic force microscopy on extensor digitorum longus muscles harvested from C57 mice.”
The Nano-Scale Mechanical Properties of the Extracellular Matrix Regulate Dermal Fibroblast Function
Achterberg, V. F., Buscemi, L., Diekmann, H., Smith-Clerc, J., Schwengler, H., Meister, J.-J., Wenck, H., Gallinat, S., & Hinz, B. (2014) · Journal of Investigative Dermatology · doi:10.1038/jid.2014.90 · Cited by 290
In situ force mapping of mammary gland transformation
Lopez, J. I., Kang, I., You, W.-K., McDonald, D. M., & Weaver, V. M. (2011) · Integrative Biology · doi:10.1039/c1ib00043h · Cited by 284
Interpenetrating fibrin–alginate matrices for in vitro ovarian follicle development
Shikanov, A., Xu, M., Woodruff, T. K., & Shea, L. D. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.06.054 · Cited by 259
Rheological Properties of Cross‐Linked Hyaluronan–Gelatin Hydrogels for Tissue Engineering
Vanderhooft, J. L., Alcoutlabi, M., Magda, J. J., & Prestwich, G. D. (2009) · Macromolecular Bioscience · doi:10.1002/mabi.200800141 · Cited by 238
Life in 3D is never flat: 3D models to optimise drug delivery
Fitzgerald, K. A., Malhotra, M., Curtin, C. M., O' Brien, F. J., & O' Driscoll, C. M. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.07.020 · Cited by 228
Kennedy, K. M., Bhaw-Luximon, A., & Jhurry, D. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.12.034 · Cited by 214
Lipski, A. M., Pino, C. J., Haselton, F. R., Chen, I.-W., & Shastri, V. P. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.002 · Cited by 187
“These observations of this study taken in sum are consistent with some recent observations wherein mechanical stimulation and strain, and surface bearing disordered nanoscale topography have been shown to favor differentiated phenotypes in stem and mesenchymal cells [38–41].”
Quantitative Evaluation of Mechanosensing of Cells on Dynamically Tunable Hydrogels
Yoshikawa, H. Y., Rossetti, F. F., Kaufmann, S., Kaindl, T., Madsen, J., Engel, U., Lewis, A. L., Armes, S. P., & Tanaka, M. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1060615 · Cited by 181
Understanding the extracellular forces that determine cell fate and maintenance
Kumar, A., Placone, J. K., & Engler, A. J. (2017) · Development · doi:10.1242/dev.158469 · Cited by 175
“Thus, our emphasis on these well-defined protocols is consistent with both a drive towards standardization of stem cell protocols and to a demand for more refined biomechanical tools (Dahl et al., 2005; Engler et al., 2007; Yim and Sheetz, 2012; Zhang et al., 2017), global force sensors (Zhou et al.”
BackgroundSelf-citationFini, M. E., Schwartz, S. G., Gao, X., Jeong, S., Patel, N., Itakura, T., Price, M. O., Price, F. W., Varma, R., & Stamer, W. D. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.09.003 · Cited by 163
“measures the indentation of the surface of tissue sections or whole mounts by a cantilever (Engler et al., 2007).”
α-Catenin cytomechanics – role in cadherin-dependent adhesion and mechanotransduction
Barry, A. K., Tabdili, H., Muhamed, I., Wu, J., Shashikanth, N., Gomez, G. A., Yap, A. S., Gottardi, C. J., de Rooij, J., Wang, N., et al. (2014) · Journal of Cell Science · doi:10.1242/jcs.139014 · Cited by 119
“The 1-kPa stiffness is comparable to lung tissue, and the 34-kPa stiffness is similar to bone (Engler et al., 2007).”
BackgroundBratskaya, S., Privar, Y., Nesterov, D., Modin, E., Kodess, M., Slobodyuk, A., Marinin, D., & Pestov, A. (2019) · Biomacromolecules · doi:10.1021/acs.biomac.8b01817 · Cited by 89
Cell differentiation through tissue elasticity-coupled, myosin-driven remodeling
Zajac, A. L., & Discher, D. E. (2008) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2008.09.006 · Cited by 88
“Many ubiquitous cytoskeletal proteins including myosin’s rod domain [37], filamin [38], spectrin [39], and ankyrin [40] have been studied by AFM as purified single molecules and found to undergo forced unfolding; likewise, many adhesion proteins including VCAM [41] and integrins [42] unfold or dissociate from their li…”
InfluentialSelf-citationVelez, D. O., Ranamukhaarachchi, S. K., Kumar, A., Modi, R. N., Lim, E. W., Engler, A. J., Metallo, C. M., & Fraley, S. I. (2019) · Integrative Biology · doi:10.1093/intbio/zyz019 · Cited by 45
Self-citation
Metadata
- Authors
- Engler, A. J., Rehfeldt, F., Sen, S., & Discher, D. E.
- Venue
- Methods in Cell Biology
- Publisher
- Elsevier
- Published
- 2007
- Volume
- 83
- Pages
- 521-545
- ISSN
- 0091-679X (ISSN-L)
- OpenAlex
- W2165489024
- Cited by
- 182
- References
- 57
- FWCI
- 16.42
- Type
- book chapter
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.