Cited by 46Medical Image Segmentation TechniquesArtificial Intelligence in Healthcare and EducationUltrasound in Clinical Applications

3-D Ultrasound Segmentation of the Placenta Using the Random Walker Algorithm: Reliability and Agreement

Stevenson, Gordon N., Collins, Sally L., Ding, Jane, Impey, Lawrence, Noble, J. Alison·2015·Ultrasound in Medicine & Biology

Abstract

Volumetric segmentation of the placenta using 3-D ultrasound is currently performed clinically to investigate correlation between organ volume and fetal outcome or pathology. Previously, interpolative or semi-automatic contour-based methodologies were used to provide volumetric results. We describe the validation of an original random walker (RW)-based algorithm against manual segmentation and an existing semi-automated method, virtual organ computer-aided analysis (VOCAL), using initialization time, inter- and intra-observer variability of volumetric measurements and quantification accuracy (with respect to manual segmentation) as metrics of success. Both semi-automatic methods require initialization. Therefore, the first experiment compared initialization times. Initialization was timed by one observer using 20 subjects. This revealed significant differences (p < 0.001) in time taken to initialize the VOCAL method compared with the RW method. In the second experiment, 10 subjects were used to analyze intra-/inter-observer variability between two observers. Bland-Altman plots were used to analyze variability combined with intra- and inter-observer variability measured by intra-class correlation coefficients, which were reported for all three methods. Intra-class correlation coefficient values for intra-observer variability were higher for the RW method than for VOCAL, and both were similar to manual segmentation. Inter-observer variability was 0.94 (0.88, 0.97), 0.91 (0.81, 0.95) and 0.80 (0.61, 0.90) for manual, RW and VOCAL, respectively. Finally, a third observer with no prior ultrasound experience was introduced and volumetric differences from manual segmentation were reported. Dice similarity coefficients for observers 1, 2 and 3 were respectively 0.84 ± 0.12, 0.94 ± 0.08 and 0.84 ± 0.11, and the mean was 0.87 ± 0.13. The RW algorithm was found to provide results concordant with those for manual segmentation and to outperform VOCAL in aspects of observer reliability. The training of an additional untrained observer was investigated, and results revealed that with the appropriate initialization protocol, results for observers with varying levels of experience were concordant. We found that with appropriate training, the RW method can be used for fast, repeatable 3-D measurement of placental volume.

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2015.07.021

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Stevenson, G. N., Collins, S. L., Ding, J., Impey, L., & Noble, J. A.
Affiliations
  • Rosie Hospital (GB)
  • John Radcliffe Hospital (GB)
  • University of Oxford (GB)
Corresponding author
Stevenson, Gordon N.
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2015-12
Volume
41
Issue
12
Pages
3182-3193
ISSN
0301-5629 (ISSN-L)
OpenAlex
W1205104456
Cited by
46
References
32
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 7 · 2019: 6 · 2018: 9 · 2017: 5 · 2016: 3
FWCI
4.92
Type
journal article
Language
en
Open access
closed
Locations
  • Ultrasound in Medicine & Biology (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute for Health and Care Research
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
Keywords
placenta segmentation, 3D ultrasound, random walker algorithm, VOCAL, observer variability, interobserver agreement, start-up time, semi-automatic segmentation, observer training
MeSH terms
Algorithms, Female, Humans, Organ Size, Placenta, Pregnancy, Ultrasonography, Reproducibility of Results, Observer Variation, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review