STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 3,901–4,000 of 47,868
Quantification of the corticospinal silent period evoked via transcranial magnetic stimulation
Damron, L. A., Dearth, D. J., Hoffman, R. L., & Clark, B. C. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.001 · Cited by 123
Lazzer, S., Boirie, Y., Meyer, M., & Vermorel, M. (2003) · British Journal of Nutrition · doi:10.1079/bjn2003983 · Cited by 107
Schmitz-Valckenberg, S., Fleckenstein, M., Göbel, A. P., Hohman, T. C., & Holz, F. G. (2010) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-5619 · Cited by 112
van Tubergen, A. M., Debats, I. B. J. G., Ryser, L., Londoño, J. D., Burgos‐Vargas, R., Cardiel, M. H., Landewé, R., Stucki, G., & van der Heijde, D. M. F. M. (2002) · Arthritis Care & Research · doi:10.1002/art.10397 · Cited by 120
Multiple method comparison: Statistical model using percentage similarity
Scott, L. E., Galpin, J. S., & Glencross, D. K. (2003) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.10016 · Cited by 106
Lobchuk, M., & Degner, L. F. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.01.153 · Cited by 106
Field evaluation of energy expenditure in women using Tritrac accelerometers
CAMPBELL, K. L., CROCKER, P. R. E., & MCKENZIE, D. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00020 · Cited by 107
Kileff, J., & Ashburn, A. (2005) · Clinical Rehabilitation · doi:10.1191/0269215505cr839oa · Cited by 133
Changes in Effective Regurgitant Orifice Throughout Systole in Patients With Mitral Valve Prolapse
Enriquez-Sarano, M. L., Sinak, L. J., Tajik, A. J., Bailey, K. R., & Seward, J. B. (1995) · Circulation · doi:10.1161/01.cir.92.10.2951 · Cited by 106
Noninvasive Monitoring of Carbon Dioxide During Respiratory Failure in Toddlers and Infants
Tobias, J. D., & Meyer, D. J. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199707000-00010 · Cited by 106
Ferriman Gallwey Self-Scoring I: Performance Assessment in Women with Polycystic Ovary Syndrome
Wild, R. A., Vesely, S., Beebe, L., Whitsett, T., & Owen, W. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-2243 · Cited by 106
Respiratory rate: measurement of variability over time and accuracy at different counting periods.
SIMOES, E. A. F., Roark, R. M., Berman, S., Esler, L. L., & Murphy, J. (1991) · Archives of Disease in Childhood · doi:10.1136/adc.66.10.1199 · Cited by 121
Agarwal, R., Bills, J. E., & Light, R. P. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.160747 · Cited by 106
Ruiz, J. R., Ramírez-Lechuga, J., Ortega, F. B., Castro‐Piñero, J., Benítez, J. M., Araúzo-Azofra, A., Sánchez‐Muñoz, C., Sjöstróm, M., Castillo, M. J., Gutiérrez, Á., et al. (2008) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2008.06.004 · Cited by 138
Uhlig, T., Haavardsholm, E. A., & Kvien, T. K. (2005) · Rheumatology · doi:10.1093/rheumatology/kei181 · Cited by 108
Validation of a new standardized method to measure proximal aneurysm neck angulation
van Keulen, J. W., Moll, F. L., Tolenaar, J. L., Verhagen, H. J. M., & van Herwaarden, J. A. (2010) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2009.10.114 · Cited by 106
ASVCP quality assurance guidelines: control of general analytical factors in veterinary laboratories
Flatland, B., Freeman, K. P., Friedrichs, K. R., Vap, L. M., Getzy, K. M., Evans, E. W., & Harr, K. E. (2010) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2010.00251.x · Cited by 106
Temporelli, P. L., Scapellato, F., Eleuteri, E., Imparato, A., & Giannuzzi, P. (2010) · Circulation Heart Failure · doi:10.1161/circheartfailure.108.809590 · Cited by 107
Haverkamp, D., Sierevelt, I. N., Breugem, S. J. M., Lohuis, K., Blankevoort, L., & van Dijk, C. N. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506288854 · Cited by 120
Gemming, L., Rush, E., Maddison, R., Doherty, A., Gant, N., Utter, J., & Ni Mhurchu, C. (2015) · British Journal of Nutrition · doi:10.1017/s0007114514003602 · Cited by 107
The interexaminer reproducibility of physical examination of the cervical spine
Pool, J. J. M., Hoving, J. L., de Vet, H. C. W., van Mameren, H., & Bouter, L. M. (2004) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2003.12.002 · Cited by 106
Thomas, B. J., Ward, L. C., & Cornish, B. (1998) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(97)00052-3 · Cited by 119
Magera, M. J., Helgeson, J. K., Matern, D., & Rinaldo, P. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.11.1804 · Cited by 106
Mudge, S., Stott, N. S., & Walt, S. E. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.07.039 · Cited by 105
Reliability of ratings of perceived exertion during progressive treadmill exercise.
Lamb, K. L., Eston, R. G., & Corns, D. (1999) · British Journal of Sports Medicine · doi:10.1136/bjsm.33.5.336 · Cited by 105
Harris lines revisited: Prevalence, comorbidities, and possible etiologies
Papageorgopoulou, C., Suter, S. K., Rühli, F. J., & Siegmund, F. (2011) · American Journal of Human Biology · doi:10.1002/ajhb.21155 · Cited by 120
Burrows, T. L., Truby, H., Morgan, P. J., Callister, R., Davies, P. S. W., & Collins, C. E. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.11.006 · Cited by 122
Simic, D. V., Mimić-Oka, J., Pljesa-Ercegovac, M. S., Savic-Radojevic, A. R., Opačić, M., Matic, M. G., Ivanović, B., & Simic, T. P. (2005) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001945 · Cited by 115
Sudha, V., Radhika, G., Sathya, R. M., Ganesan, A., & Mohan, >. (2006) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637480600969220 · Cited by 106
Haggerty, C. M., Restrepo, M., Tang, E., de Zélicourt, D., Sundareswaran, K. S., Mirabella, L., Bethel, J., Whitehead, K. K., Fogel, M. A., & Yoganathan, A. P. (2014) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2013.11.060 · Cited by 108
Wearable Sensing of In-Ear Pressure for Heart Rate Monitoring with a Piezoelectric Sensor
Park, J.-H., Jang, D.-G., Park, J., & Youm, S.-K. (2015) · Sensors · doi:10.3390/s150923402 · Cited by 106
Heart rate variability stabilization in athletes: towards more convenient data acquisition
Flatt, A. A., & Esco, M. R. (2016) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12233 · Cited by 102
Parker, R. A., Weir, C. J., Rubio, N., Rabinovich, R., Pinnock, H., Hanley, J., McCloughan, L. B., Drost, E., Mantoani, L. C., MacNee, W., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0168321 · Cited by 112
Wu, C., Tsai, H., Su, M.-Y. M., Wu, Y.-F., Hwang, J., Lin, J.-L., Lin, L., & Chen, J. (2017) · Journal of clinical lipidology · doi:10.1016/j.jacl.2017.08.018 · Cited by 111
de Koning, A., de Bruin, F., van den Berg, R., Ramiro, S., Baraliakos, X., Braun, J., van Gaalen, F. A., Reijnierse, M., & van der Heijde, D. M. F. M. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2017-211989 · Cited by 105
Liang, Z., & Martell, M. A. C. (2018) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-018-0013-1 · Cited by 121
The Consortium of Metabolomics Studies (COMETS): Metabolomics in 47 Prospective Cohort Studies
Yu, B., Zanetti, K. A., Temprosa, M. G., Albanes, D., Appel, N., Barrios-Barrera, C., Ben‐Shlomo, Y., Boerwinkle, E., Casas, J. P., Clish, C. B., et al. (2019) · American Journal of Epidemiology · doi:10.1093/aje/kwz028 · Cited by 112
Reliability and validity of the Chronojump open-source jump mat system
Pueo, B., Penichet-Tomás, A., & Jiménez-Olmedo, J. M. (2020) · Biology of Sport · doi:10.5114/biolsport.2020.95636 · Cited by 119
How unmeasured muscle mass affects estimated GFR and diagnostic inaccuracy
Nankivell, B. J., Nankivell, L. F. J., Elder, G. J., & Gruenewald, S. M. (2020) · EClinicalMedicine · doi:10.1016/j.eclinm.2020.100662 · Cited by 124
Nair, D., Tan, S.-Y., Gan, H. ‐., Lim, S.-F., Tan, J., Zhu, M., Gao, H., Chua, N.-H., Peh, W. L., & Mak, K.-H. (2007) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002306 · Cited by 112
Klasson-Heggebø, L., Andersen, L. B., Wennlöf, A. H., Sardinha, L. B., Harro, M., Froberg, K., & Anderssen, S. A. (2005) · British Journal of Sports Medicine · doi:10.1136/bjsm.2004.016113 · Cited by 105
Accuracy of the New ICare Rebound Tonometer vs. Other Portable Tonometers in Healthy Eyes
García‐Resúa, C., González‐Méijome, J. M., Gilino, J., & Yebra‐Pimentel, E. (2006) · Optometry and Vision Science · doi:10.1097/01.opx.0000200673.96758.7b · Cited by 105
Wood, L., Ducroq, D. H., Fraser, H. L., Gillingwater, S., Evans, C., Pickett, A. J., Rees, D. W., John, R., & Turkes, A. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2007.007119 · Cited by 105
Validation of the Australian/English version of the Diabetes Management Self‐Efficacy Scale
McDowell, J., Courtney, M., Edwards, H., & Shortridge‐Baggett, L. (2005) · International Journal of Nursing Practice · doi:10.1111/j.1440-172x.2005.00518.x · Cited by 105
The Oswestry Disability Index (Version 2.1a): Validation of a Dutch Language Version
van Hooff, M. L., Spruit, M., Fairbank, J. C. T., van Limbeek, J., & Jacobs, W. C. H. (2014) · Spine · doi:10.1097/brs.0000000000000683 · Cited by 121
Validity and reliability of the Children’s Visual Function Questionnaire (CVFQ)
Birch, E. E., Cheng, C. S., & Felius, J. (2007) · Journal of American Association for Pediatric Ophthalmology and Strabismus · doi:10.1016/j.jaapos.2007.02.011 · Cited by 121
Levenhagen, D. K., Borel, M. J., Welch, D. C., Piasecki, J. H., Piasecki, D. P., Chen, K. Y., & Flakoll, P. J. (1999) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607199023005293 · Cited by 107
Ayazi, S., Lipham, J. C., Portale, G., Peyré, C. G., Streets, C. G., Leers, J. M., DeMeester, S. R., Banki, F., Chan, L. S., Hagen, J. A., et al. (2008) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2008.08.020 · Cited by 105
Rapid Cortisol Assay during Adrenal Vein Sampling in Patients with Primary Aldosteronism
Mengozzi, G., Rossato, D., Bertello, C., Garrone, C., Milan, A., Pagni, R., Veglio, F., & Mulatero, P. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.092080 · Cited by 107
The Dependency of LogMAR Visual Acuity Measurements on Chart Design and Scoring Rule
Hazel, C. A., & Elliott, D. B. (2002) · Optometry and Vision Science · doi:10.1097/00006324-200212000-00011 · Cited by 105
Muscle fibre type, efficiency, and mechanical optima affect freely chosen pedal rate during cycling
Hansen, E. A., Andersen, J. L., Nielsen, J. S., & Sjøgaard, G. (2002) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2002.01032.x · Cited by 103
Insufficiency in a New Temporal-Artery Thermometer for Adult and Pediatric Patients
Suleman, M.-I., Doufas, A. G., Akça, O., Ducharme, M., & Sessler, D. I. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200207000-00012 · Cited by 107
Fouré, A., Nordez, A., McNair, P. J., & Cornu, C. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1667-4 · Cited by 129
de Winter, A. F., Heemskerk, M., Terwee, C. B., Jans, M. P., Devillé, W. L. J. M., van Schaardenburg, D., Scholten, R. J. P. M., & Bouter, L. M. (2004) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-5-18 · Cited by 105
Amigoni, M., Meris, A., Thune, J. J., Gopal, D. M., Skali, H., Bourgoun, M., Warnica, J. W., Barvik, S., Arnold, J. M. O., Velazquez, E. J., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl464 · Cited by 106
Development and evaluation of social cognitive measures related to adolescent dietary behaviors
Dewar, D. L., Lubans, D. R., Plotnikoff, R. C., & Morgan, P. J. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-36 · Cited by 105
Holle, V. V., Bourdeaudhuij, I. D., Deforche, B. I., Cauwenberg, J. V., & Dyck, D. V. (2015) · BMC Public Health · doi:10.1186/s12889-015-1785-3 · Cited by 126
Pavey, T., Gomersall, S. R., Clark, B., & Brown, W. J. (2015) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2015.04.007 · Cited by 131
Romeo, E., Lops, D., Margutti, E., Ghisolfi, M., Chiapasco, M., & Vogel, G. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.120905.x · Cited by 105
Malaria Mapping Using Transmission Models: Application to Survey Data from Mali
Gemperli, A., Vounatsou, P., Sogoba, N., & Smith, T. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj026 · Cited by 105
Clinical and immunologic aspects of cancer-associated retinopathy
Ohguro, H., Yokoi, Y., Ohguro, I., Mamiya, K., Ishikawa, F., Yamazaki, H., Metoki, T., Takano, Y., Ito, T., & Nakazawa, M. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.01.010 · Cited by 105
RELIABILITY OF ISOKINETIC ANKLE DORSIFLEXOR STRENGTH MEASUREMENTS IN HEALTHY YOUNG MEN AND WOMEN
Holmbäck, A. M. (1999) · Scandinavian Journal of Rehabilitation Medicine · doi:10.1080/003655099444407 · Cited by 106
Altiok, E., Hamada, S., Brehmer, K., Kuhr, K., Reith, S., Becker, M., Schröder, J. W., Almalla, M., Lehmacher, W., Marx, N., et al. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.112.974691 · Cited by 105
Inter- and intrasubject variability of solid and liquid gastric emptying parameters
Lartigue, S., Bizais, Y., Varannes, S. B. D., Murat, A., Pouliquen, B., & Galmiche, J. P. (1994) · Digestive Diseases and Sciences · doi:10.1007/bf02090069 · Cited by 105
Fatkin, D., Christe, M. E., Aristizabal, O., McConnell, B. K., Srinivasan, S., Schoen, F. J., Seidman, C. E., Turnbull, D. H., & Seidman, J. G. (1999) · Journal of Clinical Investigation · doi:10.1172/jci4631 · Cited by 107
Gilja, O. H., Smievoll, A. I., Thune, N., Matre, K., Hausken, T., Ødegaard, S., & Berstad, A. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00082-4 · Cited by 105
Ronchi, M. C., Piragino, C., Rosi, E., Amendola, M., Duranti, R., & Scano, G. (1996) · Thorax · doi:10.1136/thx.51.10.1000 · Cited by 105
Abrahamsen, B., Hansen, T., Høgsberg, I. M., Fb, P., & Beck‐Nielsen, H. (1996) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/63.1.80 · Cited by 124
Caso, P., Galderisi, M., Cicala, S., Cioppa, C., D’Andrea, A., Lagioia, G., Liccardo, B., Martiniello, A. R., & Mininni, N. (2001) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2001.115033 · Cited by 114
Factors influencing Doppler indexes of left ventricular filling in healthy persons
Voutilainen, S., Kupari, M. M., Hippeläinen, M., Karppinen, K. J., Ventiä, M., & Heikkilä, J. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90360-w · Cited by 105
Volume measurement of multiple sclerosis lesions with magnetic resonance images
Wicks, D., Tofts, P. S., Miller, D. H., du Boulay, G. H., Feinstein, A., Sacares, R. P., Harvey, I., Brenner, R., & McDonald, W. I. (1992) · Neuroradiology · doi:10.1007/bf00598953 · Cited by 105
Naik, M. M., Diamond, G. A., Pai, T., Soffer, A., & Siegel, R. J. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00506-l · Cited by 105
Body cell mass: model development and validation at the cellular level of body composition
Wang, Z., St-Onge, M.-P., Lecumberri, B., Pi-Sunyer, F. X., Heshka, S., Wang, J., Kotler, D. P., Gallagher, D., Wielopolski, L., Pierson, R. N., et al. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00227.2003 · Cited by 105
Oberoi, S., & Knueppel, S. (2012) · Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology · doi:10.1016/j.tripleo.2011.03.035 · Cited by 104
On the reliability of coverage-based fuzzer benchmarking
Böhme, M., Szekeres, L., & Metzman, J. (2022) · Proceedings of the 44th International Conference on Software Engineering · doi:10.1145/3510003.3510230 · Cited by 104
Sanduleanu, S., Driessen, A. L. C., Gómez-García, E. B., Hameeteman, W. M., de Bruïne, A. P., & Masclee, A. (2009) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2009.08.006 · Cited by 113
The Association Between symptoms of Discomfort and signs in Dry Eye
Johnson, M. E. (2009) · The Ocular Surface · doi:10.1016/s1542-0124(12)70187-8 · Cited by 122
Langton, D., Sprowson, A. P., Mahadeva, D., Bhatnagar, S., Holland, J. P., & Nargol, A. V. F. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2009.08.020 · Cited by 104
Impact of time since last caloric intake on blood glucose levels
Moebus, S., Göres, L., Lösch, C., & Jöckel, K.-H. (2011) · European Journal of Epidemiology · doi:10.1007/s10654-011-9608-z · Cited by 103
The Effect of Cycloplegia on the Lenstar and the IOLMaster Biometry
Huang, J., McAlinden, C., Su, B., Pesudovs, K., Feng, Y., Hua, Y., Yang, F., Pan, C., Zhou, H., & Wang, Q. (2012) · Optometry and Vision Science · doi:10.1097/opx.0b013e3182772f4f · Cited by 104
Jardine, J., Glinianaia, S. V., McConachie, H., Embleton, N. D., & Rankin, J. M. (2014) · PEDIATRICS · doi:10.1542/peds.2014-0352 · Cited by 120
Juul, T., Langberg, H., Enoch, F., & Søgaard, K. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-339 · Cited by 109
Veerapathran, A., Joshi, R. P., Goswami, K., Dogra, S., Moodie, E. E. M., Reddy, M. V. R., Kalantri, S., Schwartzman, K., Behr, M. A., Menzies, D., et al. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001850 · Cited by 104
Fosfomycin Susceptibility in Carbapenem-Resistant Enterobacteriaceae from Germany
Kaase, M., Szabados, F., Anders, A., & Gatermann, S. G. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.03484-13 · Cited by 109
Bioharness(™) multivariable monitoring device: part. I: validity.
Johnstone, J., Ford, P. A., Hughes, G., Watson, T., & Garrett, A. T. (2012) · Europe PMC (PubMed Central) · Cited by 157
de Morton, N. A., Berlowitz, D. J., & Keating, J. L. (2008) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-6-44 · Cited by 121
Validity of Two Self-Report Measures of Sitting Time
Clemes, S. A., David, B. M., Zhao, Y., Han, X., & Brown, W. (2012) · Journal of Physical Activity and Health · doi:10.1123/jpah.9.4.533 · Cited by 103
Sujirakul, T., Lin, M. K., Duong, J., Wei, Y., López‐Pintado, S., & Tsang, S. H. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.06.032 · Cited by 113
Annular Geometry in Patients With Chronic Ischemic Mitral Regurgitation
Kaji, S., Nasu, M., Yamamuro, A., Tanabe, K., Nagai, K., Tani, T., Tamita, K., Shiratori, K., Kinoshita, M., Senda, M., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.525246 · Cited by 104
Tsikas, D., Rothmann, S., Schneider, J. Y., Suchy, M.-T., Trettin, A., Modun, D., Stuke, N., Maassen, N., & Frölich, J. C. (2015) · Journal of Chromatography B · doi:10.1016/j.jchromb.2015.10.009 · Cited by 104
Smith-Ryan, A. E., Mock, M. G., Ryan, E. D., Gerstner, G. R., Trexler, E. T., & Hirsch, K. R. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.05.006 · Cited by 105
The accuracy of breast volume measurement methods: A systematic review
Choppin, S. B., Wheat, J. S., Gee, M., & Goyal, A. (2016) · The Breast · doi:10.1016/j.breast.2016.05.010 · Cited by 112
Passos, M. H. P., Silva, H. A., Pitangui, A. C. R., Oliveira, V. M. A., Lima, A. S., & Araújo, R. C. (2017) · Jornal de Pediatria · doi:10.1016/j.jped.2016.06.006 · Cited by 101
Hyodo, T., Yada, N., Hori, M., Maenishi, O., Lamb, P., Sasaki, K., Onoda, M., Kudo, M., Mochizuki, T., & Murakami, T. (2017) · Radiology · doi:10.1148/radiol.2017160130 · Cited by 103
Psychometric properties of the Zephyr bioharness device: a systematic review
Nazari, G., Bobos, P., MacDermid, J. C., Sinden, K. E., Richardson, J., & Tang, A. (2018) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-018-0094-4 · Cited by 101
Rodríguez‐Mañero, M., Valderrábano, M., Baluja, A., Kreidieh, O., Martínez‐Sande, J. L., García‐Seara, J., Saenen, J. B., Iglesias-Álvarez, D., Bories, W., Villamayor-Blanco, L. M., et al. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.08.015 · Cited by 116
The nottingham system: Objective assessment of facial nerve function in the clinic
Murty, G. E., Diver, J. P., Kelly, P. J., O’Donoghue, G. M., & Bradley, P. J. (1994) · Otolaryngology · doi:10.1177/019459989411000203 · Cited by 104
Simplifying the Welfare Quality® assessment protocol for broiler chicken welfare
de Jong, I. C., Hindle, V. A., Butterworth, A., Engel, B., Ferrari, P., Gunnink, H., Moya, T. P., Tuyttens, F., & van Reenen, C. G. (2015) · animal · doi:10.1017/s1751731115001706 · Cited by 104
Value of transvaginal ultrasound in assessing severity of pelvic endometriosis
Holland, T. K., Yazbek, J., Cutner, A., Saridogan, E., Hoo, W. L., & Jurkovic, D. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7689 · Cited by 104
Performance and Repeatability of the NEI-VFQ-25 in Patients With Dry Eye
Nichols, K. K., Mitchell, G. L., & Zadnik, K. (2002) · Cornea · doi:10.1097/00003226-200208000-00009 · Cited by 114
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.