STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“and all parameters used for the proposition and cross-validation of the model confirmed their validity for the studied population (15, 37–39, 57)”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [39]
In the citing paper
“Each volume measurement was performed twice to determine reproducibility by the method of Bland and Altman (1986).”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as Bland and Altman (1986)
In the citing paper
“After a fairly extensive search of physics textbooks and the scientific literature over a number of years, no direct references to the technique have been discovered 1 .”
From Archimedes revisited: a faster, better, cheaper method of accurately measuring the volume of small objects (2005) · cites this paper as [1]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
In the citing paper
“However, paired t test and Bland-Altman plot are methods for analyzing agreement, and Pearson correlation coefficient is only a measure of correlation, and hence, they are nonideal measures of reliability.”
From A guideline of selecting and reporting intraclass correlation coefficients for reliability research (2016) · cites this paper as [6]
2 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Self-citationStatistical Methods in Medical Research
(1972) · Postgraduate Medical Journal · doi:10.1136/pgmj.48.555.67-a · Cited by 526
RELATION BETWEEN INITIAL BLOOD PRESSURE AND ITS FALL WITH TREATMENT
Gill, J. S., Beevers, D. G., Zezulka, A. V., & Davies, P. (1985) · The Lancet · doi:10.1016/s0140-6736(85)91219-x · Cited by 156
The Nellcor N‐101 pulse oximeter: A clinical evaluation in anaesthesia and intensive care
TYTLER, J. A., & SEELEY, H. F. (1986) · Anaesthesia · doi:10.1111/j.1365-2044.1986.tb12793.x · Cited by 32
Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter.
Oldham, H. G., Bevan, M. M., & McDermott, M. (1979) · Thorax · doi:10.1136/thx.34.6.807 · Cited by 28
Estimation of gestational age at birth. Comparison of two methods.
Serfontein, G. L., & Jaroszewicz, A. M. (1978) · Archives of Disease in Childhood · doi:10.1136/adc.53.6.509 · Cited by 23
D'Arbela, P. G., Silayan, Z. M., & Bland, M. (1986) · Heart · doi:10.1136/hrt.56.5.445 · Cited by 4
Cited by
Items 4,201–4,300 of 47,868
Strandberg, S., Wretling, M.-L., Wredmark, T., & Shalabi, A. (2010) · BMC Medical Imaging · doi:10.1186/1471-2342-10-18 · Cited by 102
Cyclotorsion: A possible cause of residual astigmatism in refractive surgery
Tjon-Fo-Sang, M. J. H., de Faber, J. T., Kingma-Wilschut, C., & Beekhuis, H. W. (2002) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(01)01279-2 · Cited by 100
Kontiola, A., & Puska, P. M. (2003) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-003-0671-3 · Cited by 100
Liu, L., Wang, P. P., Roebothan, B., Ryan, A., Tucker, C. S., Colbourne, J., Baker, N., Cotterchio, M., Yi, Y., & Sun, G. (2013) · Nutrition Journal · doi:10.1186/1475-2891-12-49 · Cited by 99
Russell, I. F. (2004) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2003.12.007 · Cited by 101
de Groot, S., Balvers, I. J. M., Kouwenhoven, S. M., & Janssen, T. W. J. (2012) · Journal of Sports Sciences · doi:10.1080/02640414.2012.675082 · Cited by 111
Gentilcore, D., Hausken, T., Horowitz, M., & Jones, K. L. (2006) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2006.00830.x · Cited by 101
Angelini, E. D., Homma, S., Pearson, G. D. N., Holmes, J. W., & Laine, A. F. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.03.016 · Cited by 100
Klinke, V., Muzzarelli, S., Lauriers, N., Locca, D., Vincenti, G. M., Monney, P. A., Lu, C., Nothnagel, D., Pilz, G., Lombardi, M., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-55 · Cited by 100
Reinhard, M., ller, T. M., Guschlbauer, B., Timmer, J., & Hetzel, A. (2002) · Physiological Measurement · doi:10.1088/0967-3334/24/1/303 · Cited by 100
Left-ventricle myocardium segmentation using a coupled level-set with a priori knowledge
Lynch, M., Ghita, O., & Whelan, P. F. (2006) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2006.03.009 · Cited by 100
McKeown, H. F., Robinson, D. L., Elcock, C., al-Sharood, M., & Brook, A. H. (2002) · European Journal of Orthodontics · doi:10.1093/ejo/24.2.131 · Cited by 120
Hashemi, H., & Mehravaran, S. (2007) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2007.05.040 · Cited by 100
Krijt, J., Vacková, M., & Kožich, V. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.10.1821 · Cited by 100
Salvetat, M. L., Zeppieri, M., Tosoni, C., Felletti, M., Grasso, L., & Brusini, P. (2014) · Journal of Glaucoma · doi:10.1097/ijg.0000000000000133 · Cited by 100
Delesalle, C. J. G., Dewulf, J., Lefebvre, R. A., Schuurkes, J. A. J., Proot, J., Lefère, L., & Deprez, P. R. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb02963.x · Cited by 100
Variability of the Blood/Breath Alcohol Ratio in Drinking Drivers
Jones, A. W., & Andersson, L. (1996) · Journal of Forensic Sciences · doi:10.1520/jfs14025j · Cited by 100
Accuracy of a Tablet Audiometer for Measuring Behavioral Hearing Thresholds in a Clinical Population
Thompson, G. P., Sladen, D. P., Hughes-Borst, B., & Still, O. L. (2015) · Otolaryngology · doi:10.1177/0194599815593737 · Cited by 100
Collee, G., Lomax, D., Ferguson, C., & Hanson, G. C. (1993) · Intensive Care Medicine · doi:10.1007/bf01711092 · Cited by 100
Validity of Ultrasound Estimation of Fetal Weight
CHIEN, P. F. W., OWEN, P., & KHAN, K. S. (2000) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(00)00828-0 · Cited by 100
A method to score radiographic change in psoriatic arthritis
Wassenberg, S., Fischer-Kahle, V., Herborn, G., & Rau, R. (2001) · Zeitschrift für Rheumatologie · doi:10.1007/s003930170064 · Cited by 100
Bridge, P. D., Ranganathan, S., & McKenzie, S. A. (1999) · European Respiratory Journal · doi:10.1034/j.1399-3003.1999.13d16.x · Cited by 100
Cephalic stimulation of gastrointestinal secretory and motor responses in humans
Katschinski, M., Dahmen, G., Reinshagen, M., Beglinger, C., Koop, H., Nustede, R., & Adler, G. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)90825-j · Cited by 100
C-Reactive Protein and Carotid Intimal Medial Thickness in a Community Population
Sitzer, M., Markus, H. S., Mendall, M. A., Liehr, R., Knorr, U., & Steinmetz, H. (2002) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1177/174182670200900205 · Cited by 100
Reducing random measurement error in assessing postural load on the back in epidemiologic surveys
Alex Burdorf, A. (1995) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.3 · Cited by 100
Rogers, J. E., Laurberg, S., Misiewicz, J. J., Henry, M. M., & Swash, M. (1989) · British journal of surgery · doi:10.1002/bjs.1800760628 · Cited by 100
Formoterol Compared with Beclomethasone and Placebo on Allergen-induced Asthmatic Responses
Wong, B., Dolovich, J., Ramsdale, E. H., O’Byrne, P. M., Gontovnick, L., Denburg, J. A., & Hargreave, F. E. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.5_pt_1.1156 · Cited by 100
Savastano, S., Belfiore, A., Di Somma, C., Mauriello, C., Rossi, A., Pizza, G., De Rosa, A., Prestieri, G., Angrisani, L., & Colao, A. (2010) · Obesity Surgery · doi:10.1007/s11695-009-0006-5 · Cited by 100
The influence of inspiratory and expiratory muscle training upon rowing performance
Griffiths, L. A., & McConnell, A. K. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0367-6 · Cited by 99
Okuda, K., Nakajima, K., Hosoya, T., Ishikawa, T., Konishi, T., Matsubara, K., Matsuo, S., & Kinuya, S. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9313-4 · Cited by 99
Saitoh, T., Shiota, M., Izumo, M., Gurudevan, S. V., Tolstrup, K., Siegel, R. J., & Shiota, T. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.01.391 · Cited by 99
McAdams‐DeMarco, M., Maynard, J. W., Baer, A. N., Köttgen, A., Clipp, S. L., Coresh, J., & Gelber, A. C. (2010) · The Journal of Rheumatology · doi:10.3899/jrheum.100418 · Cited by 99
Hornett, E. A., & Wheat, C. W. (2012) · BMC Genomics · doi:10.1186/1471-2164-13-361 · Cited by 118
Lima, V. D., Harrigan, R., & Montaner, J. S. G. (2009) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e31819e721b · Cited by 99
Reverter, E., Blasi, A., Abraldeṣ, J. G., Martínez‐Palli, G., Seijó, S., Turón, F., Berzigotti, A., Balust, J., Bosch, J., & García‐Pagán, J. C. (2013) · Liver International · doi:10.1111/liv.12229 · Cited by 99
Matsuoka, N., Kohriyama, T., Ochi, K., Nishitani, M., Sueda, Y., Mimori, Y., Nakamura, S., & Matsumoto, M. (2004) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2003.11.011 · Cited by 99
What is the Best Method for Assessing Lower Limb Force-Velocity Relationship?
Giroux, C., Rabita, G., Chollet, D., & Guilhem, G. (2014) · International Journal of Sports Medicine · doi:10.1055/s-0034-1385886 · Cited by 99
Reduced Patellar Tendon Elasticity with Aging: In Vivo Assessment by Shear Wave Elastography
Hsiao, M., Chen, Y.-C., Lin, C.-Y., Chen, W., & Wang, T. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.07.008 · Cited by 100
Segmentation of the Left Ventricle From Cardiac MR Images Using a Subject-Specific Dynamical Model
Zhu, Y. H., Papademetris, X., Sinusas, A. J., & Duncan, J. S. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2031063 · Cited by 106
Accuracy, calibration and clinical performance of the new EuroSCORE II risk stratification system
Dedda, U. D., Pelissero, G., Agnelli, B., Vincentiis, C. D., Castelvecchio, S., & Ranucci, M. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs196 · Cited by 113
Hoogeboom, T. J., de Bie, R. A., den Broeder, A. A., & van den Ende, C. H. (2012) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-13-117 · Cited by 120
Gaber, R. M., Shaheen, E., Falter, B., Araya, S. C., Politis, C., Swennen, G. R. J., & Jacobs, R. (2017) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2017.05.025 · Cited by 108
Sanders, M., Servaas, S., & Slagt, C. (2020) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00330-y · Cited by 96
Negishi, T., Abe, S., Matsui, T., Liu, H., Kurosawa, M., Kirimoto, T., & Sun, G. (2020) · Sensors · doi:10.3390/s20082171 · Cited by 114
Impact of COVID-19 Lockdown on Physical Activity in a Sample of Greek Adults
Bourdas, D. I., & Zacharakis, E. (2020) · Sports · doi:10.3390/sports8100139 · Cited by 117
MarkVCID cerebral small vessel consortium: I. Enrollment, clinical, fluid protocols
Wilcock, D. M., Jicha, G. A., Blacker, D., Albert, M., D’Orazio, L. M., Elahi, F. M., Fornage, M., Hinman, J. D., Knoefel, J. E., Kramer, J. H., et al. (2021) · Alzheimer s & Dementia · doi:10.1002/alz.12215 · Cited by 103
Toward a national eDNA strategy for the United States
Kelly, R. P., Lodge, D. M., Lee, K. N., Theroux, S. M., Sepulveda, A. J., Scholin, C. A., Craine, J. M., Allan, E. A., Nichols, K. M., Parsons, K. M., et al. (2023) · Environmental DNA · doi:10.1002/edn3.432 · Cited by 116
McLean, A. S., Needham, A., Stewart, D., & Parkin, R. (1997) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9702500307 · Cited by 99
Coss‐Bu, J. A., Jefferson, L., Walding, D., David, Y., Smith, E., & Klish, W. J. (1998) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/67.1.74 · Cited by 112
Anatomical Gender Differences in Cervical Vertebrae of Size-Matched Volunteers
Stemper, B. D., Yoganandan, N., Pintar, F. A., Maiman, D. J., Meyer, M. A., DeRosia, J., Shender, B. S., & Paskoff, G. R. (2008) · Spine · doi:10.1097/brs.0b013e318160462a · Cited by 99
Schlosser, T. W., Mohrs, O. K., Magedanz, A., Voigtländer, T., Schmermund, A., & Barkhausen, J. (2007) · Acta Radiologica · doi:10.1080/02841850601067611 · Cited by 99
Obstructive Apnea Hypopnea Index Estimation by Analysis of Nocturnal Snoring Signals in Adults
Ben-Israel, N. I., Tarasiuk, A., & Zigel, Y. (2012) · SLEEP · doi:10.5665/sleep.2092 · Cited by 112
The Letter Contrast Sensitivity Test: Clinical Evaluation of a New Design
Haymes, S. A., Roberts, K. F., Cruess, A. F., Nicolela, M. T., LeBlanc, R. P., Ramsey, M. S., Chauhan, B. C., & Artes, P. H. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1419 · Cited by 119
Quantifying Positional Plagiocephaly: Reliability and Validity of Anthropometric Measurements
Mortenson, P., & Steinbok, P. (2006) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200605000-00005 · Cited by 110
Glomerular filtration rate measurement by “single-shot” injection of inulin
Florijn, K. W., Barendregt, J. N. M., Lentjes, E. G. W. M., van Dam, W., Prodjosudjadi, W., van Saase, J. L. C. M., van Es, L. A., & Chang, P. C. (1994) · Kidney International · doi:10.1038/ki.1994.267 · Cited by 99
Parissi, M., Karanis, G., Randjelovic, S., Germundsson, J., Poletti, E., Ruggeri, A., Utheim, T. P., & Lagali, N. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-12999 · Cited by 108
Examination of the Metamax I and II oxygen analysers during exercise studies in the laboratory
Medbø, J. I., Mamen, A., Welde, B., von Heimburg, E. D., & Stokke, R. (2002) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655102764654321 · Cited by 113
Goldoni, M., Catalani, S., Palma, G. D., Manini, P., Acampa, O., Corradi, M., Bergonzi, R., Apostoli, P., & Mutti, A. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.7108 · Cited by 99
Development and Reproducibility of the Bone Loading History Questionnaire
DOLAN, S. H., WILLIAMS, D. P., AINSWORTH, B. E., & SHAW, J. M. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000222841.96885.a8 · Cited by 101
Can the Internet be used as a medium to evaluate knee angle?
Russell, T. G., Jull, G. A., & Wootton, R. (2003) · Manual Therapy · doi:10.1016/s1356-689x(03)00016-x · Cited by 104
Beerbaum, P., Körperich, H., Gieseke, J., Barth, P., Peuster, M., & Meyer, H. (2003) · Circulation · doi:10.1161/01.cir.0000087603.97036.c2 · Cited by 99
Kelly, A., McAlpine, R., & Kyle, E. (2001) · Respiratory Medicine · doi:10.1053/rmed.2001.1046 · Cited by 111
Monitoring of a civil structure’s state based on noncontact measurements
Kohut, P., Holak, K., Uhl, T., Ortyl, Ł., Owerko, T., Kuraś, P., & Kocierz, R. (2013) · Structural Health Monitoring · doi:10.1177/1475921713487397 · Cited by 106
Accuracy of point‐of‐care‐testing (POCT) for determining hemoglobin concentrations
Gehring, H., Hornberger, C., Dibbelt, L., Roth‐Isigkeit, A., Gerlach, K., Schumacher, J., & Schmucker, P. (2002) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2002.460809.x · Cited by 98
Sukantarat, K. T., Williamson, R. C. N., & Brett, S. J. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2006.04948.x · Cited by 99
Minimum Detectable Change in Gait Velocity during Acute Rehabilitation following Hip Fracture
Hollman, J. H., Beckman, B. A., Brandt, R. A., Merriwether, E. N., Williams, R. T., & Nordrum, J. T. (2008) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200831020-00003 · Cited by 99
Santos, C., Bernardes, J., Ayres‐de‐Campos, D., Costa, A., & Amorim‐Costa, C. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.11.010 · Cited by 99
Cayne, N. S., Veith, F. J., Lipsitz, E. C., Ohki, T., Mehta, M., Gargiulo, N., Suggs, W. D., Rozenblit, A. M., Ricci, Z. J., & Timaran, C. H. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2003.11.042 · Cited by 99
Dehghani, C., Pritchard, N., Edwards, K. P., Russell, A. W., Malik, R. A., & Efron, N. (2014) · Cornea · doi:10.1097/ico.0000000000000152 · Cited by 100
Kuti, J. L., Nightingale, C. H., & Nicolau, D. P. (2004) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.48.7.2464-2470.2004 · Cited by 100
Evaluation of “point of care” devices in the measurement of low blood glucose in neonatal practice
Ho, H. T., Yeung, W. K. Y., & Young, B. W. Y. (2004) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2003.033548 · Cited by 99
Sanusi, A. A., Arogundade, F. A., Famurewa, O. C., Akintomide, A. O., Soyinka, F. O., Ojo, O., & Akinsola, A. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp055 · Cited by 101
Medhus, A. W., Lofthus, C. M., Bredesen, J., & Husebye, E. (2001) · Neurogastroenterology & Motility · doi:10.1046/j.1365-2982.2001.00249.x · Cited by 96
Myocardial Strain Analysis in Acute Coronary Occlusion
Lyseggen, E., Skulstad, H., Helle-Valle, T. M., Vartdal, T., Urheim, S., Rabben, S. I., Opdahl, A., Ihlen, H., & Smiseth, O. A. (2005) · Circulation · doi:10.1161/circulationaha.105.533372 · Cited by 99
Respiratory function in healthy young children using forced oscillations
Hall, G. L., Sly, P. D., Fukushima, T., Kusel, M. M. H., Franklin, P., Horak, F., Patterson, H., Gangell, C. L., & Stick, S. M. (2007) · Thorax · doi:10.1136/thx.2006.067835 · Cited by 100
Miyanishi, K., Noguchi, Y., Yamamoto, T., Irisa, T., Suenaga, E., Jingushi, S., Sugioka, Y., & Iwamoto, Y. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b4.0820512 · Cited by 99
Buck, F. M., Guggenberger, R., Koch, P. P., & Pfirrmann, C. W. A. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.8295 · Cited by 107
Carty, E., Brabander, M. D., Feakins, R. M., & Rampton, D. S. (2000) · Gut · doi:10.1136/gut.46.4.487 · Cited by 99
Transcutaneous Bilirubin Measurements and Serum Total Bilirubin Levels in Indigenous African Infants
Slusher, T. M., Angyo, I. A., Bode-Thomas, F., Akor, F., Pam, S. D., Adetunji, A. A., McLaren, D. W., Wong, R. J., Vreman, H. J., & Stevenson, D. K. (2004) · PEDIATRICS · doi:10.1542/peds.113.6.1636 · Cited by 99
A simple diagnostic test using GH-releasing peptide-2 in adult GH deficiency
Chihara, K., Shimatsu, A., Hizuka, N., Tanaka, T., Seino, Y., Katofor, Y., & _, _. (2007) · European Journal of Endocrinology · doi:10.1530/eje-07-0066 · Cited by 98
Browning, L. M., Mugridge, O., Chatfield, M. D., Dixon, A. K., Aitken, S. W., Joubert, I., Prentice, A. M., & Jebb, S. A. (2010) · Obesity · doi:10.1038/oby.2010.71 · Cited by 103
Nielsen, J., Schrøder, H. D., Rix, C. G., & Ørtenblad, N. (2009) · The Journal of Physiology · doi:10.1113/jphysiol.2009.174862 · Cited by 101
Holland‐Letz, T., Endres, H. G., Biedermann, S., Mahn, M., Kunert, J., Groh, S., Pittrow, D., von Bilderling, P., Sternitzky, R., & Diehm, C. (2007) · Vascular Medicine · doi:10.1177/1358863x07077281 · Cited by 110
Willis, T. A., Hollingsworth, K. G., Coombs, A., Sveen, M., Andersen, S., Stojkovic, T., Eagle, M., Mayhew, A. G., de Sousa, P. L., Dewar, L., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0090377 · Cited by 99
Lower limb skeletal muscle mass: development of dual-energy X-ray absorptiometry prediction model
Shih, R., Wang, Z., Heo, M., Wang, W., & Heymsfield, S. B. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1380 · Cited by 101
Brown, N. J., Salome, C. M., Berend, N., Thorpe, C. W., & King, G. G. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200609-1317oc · Cited by 105
Actigraphy Scoring Reliability in the Study of Osteoporotic Fractures
Blackwell, T., Ancoli-Israel, S., Gehrman, P. R., Schneider, J. L., Pedula, K. L., & Stone, K. L. (2005) · Sleep · doi:10.1093/sleep/28.12.1599 · Cited by 99
Zwart, T. C., Gokoel, S. R. M., van der Boog, P. J. M., de Fijter, J. W., Kweekel, D. M., Swen, J. J., Guchelaar, H., & Moes, D. J. A. R. (2018) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.13755 · Cited by 99
Pulmonary and systemic effects of inhaled endotoxin in control and heaves horses
Pirie, R. S., Dixon, P. M., Collie, D., & McGorum, B. C. (2001) · Equine Veterinary Journal · doi:10.2746/042516401776249732 · Cited by 99
Garway‐Heath, D. F., Poinoosawmy, D., Wollstein, G., Viswanathan, A. C., Kamal, D., Fontana, L., & Hitchings, R. A. (1999) · British Journal of Ophthalmology · doi:10.1136/bjo.83.6.664 · Cited by 99
Application of the Vestibular Disorders Activities of Daily Living Scale
Cohen, H. S., Kimball, K. T., & Adams, A. S. (2000) · The Laryngoscope · doi:10.1097/00005537-200007000-00026 · Cited by 107
Work of Breathing After Extubation
Ishaaya, A. M., Nathan, S. D., & Belman, M. J. (1995) · CHEST Journal · doi:10.1378/chest.107.1.204 · Cited by 105
Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT
Kriekinge, S. D. V., Berman, D. S., & Germano, G. (1999) · Journal of Nuclear Cardiology · doi:10.1016/s1071-3581(99)90022-3 · Cited by 99
Franco, E., Saunders, C. P., ROBERTS, G. J., & Suwanprasit, A. (1996) · PubMed · Cited by 99
Hinnen, J.-W., Koning, O. H. J., van Bockel, H. J., & Hamming, J. F. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.04.069 · Cited by 99
Sweetnam, P. M., Bolton, C. H., Yarnell, J. W., Bainton, D., Baker, I. A., Elwood, P. C., & Miller, N. E. (1994) · Circulation · doi:10.1161/01.cir.90.2.769 · Cited by 98
The desaturation response time of finger pulse oximeters during mild hypothermia*
MacLeod, D. B., Cortinez, L. I., Keifer, J. C., Cameron, D., Wright, D. R., White, W. D., Moretti, E. W., Radulescu, L. R., & Somma, J. (2005) · Anaesthesia · doi:10.1111/j.1365-2044.2004.04033.x · Cited by 98
GARABELLI, P., STAVRAKIS, S., ALBERT, M., KOOMSON, E., PARWANI, P., CHOHAN, J., SMITH, L., ALBERT, D., XIE, R., XIE, Q., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12976 · Cited by 98
Use of the Broselow Tape May Result in the Underresuscitation of Children
Nieman, C. T., Manacci, C. F., Super, D. M., Mancuso, C., & Fallon, W. F. (2006) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2006.tb00270.x · Cited by 98
Reliability and agreement studies: a guide for clinical investigators
Hernáez, R. (2015) · Gut · doi:10.1136/gutjnl-2014-308619 · Cited by 116
Metadata
- Authors
- Martin Bland, J., & Altman, D.
- Venue
- The Lancet
- Publisher
- Elsevier BV
- Published
- 1986-02
- Volume
- 327
- Issue
- 8476
- Pages
- 307-310
- ISSN
- 0099-5355 (ISSN-L)
- 0140-6736
- OpenAlex
- W2015795623
- Cited by
- 47,965
- References
- 7
- Citations by year
- 2026: 1541 · 2025: 1310 · 2024: 1377 · 2023: 1382 · 2022: 1513 · 2021: 1827 · 2020: 1878 · 2019: 1797 · 2018: 1725 · 2017: 1906 · 2016: 1876 · 2015: 1983 · 2014: 2081 · 2013: 2031 · 2012: 2082
- FWCI
- 149.89
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The Lancet (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Keywords
- agreement between measurement methods, method comparison, correlation coefficient limitations, repeatability, clinical measurement
- MeSH terms
- Diagnosis, Humans, Peak Expiratory Flow Rate, Statistics as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.